ML20237H802

From kanterella
Jump to navigation Jump to search
Corrected Monthly Operating Repts for Apr 1987
ML20237H802
Person / Time
Site: Prairie Island  
Issue date: 04/30/1987
From: Dugstad D
NORTHERN STATES POWER CO.
To:
Shared Package
ML20237H610 List:
References
NUDOCS 8708170363
Download: ML20237H802 (2)


Text

{{#Wiki_filter:- OF G A LING _ Dele _BEEORI DOCKET NO. 50-282 UNIT PRAIRIE ISLAND N0.1 DATE MAY 5, 1987 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-ii2i DEEBeIING_SIeIUS

1. UNIT NAME:

EBeISIE_ISLeUD_NO _1 C T4 P6 (MWT)- 50~ l (CM.[.g' /. jg l ~ l 4. NAMEPLATE RATING (GROSS MWE). 593

5. DESIGN ELECTRICAL RATING (NET MWE) 530 l

l

6. MAXIMUM DEPENDABLE CAPACITY-(GROSS MWE) 534 l

l 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE). 503 1____________________1 8. IF CHANGES OCCUR IN CAPAiL1Y R A TINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT GIVE REASON: UQUE_______________________________

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)

_UQUE______________

10. REASONS FOR RESTRICTIONS, IF ANY:__NONE_______________________________

IBIS _dQUIH XB:IO:DeIE CUbuLeIIVE j ii. HOURS IN REPORTING PER10D 719 2879 117215 j l 12. NUMBER OF HOURS REACTOR WAS CRITICAL 166.2 2040.4 97296.0 ' 13. REACTOR RESERVE SHUTDOWN HnURS 0.0 0.0 5571.i ' 14. HOURS GENERATOR ON-LINE 165.2 2033.3 95907.0 '15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 i6. GROSS THERMAL ENERGY G W RA1ED (MWH) i86785 3081418 150688386

17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 54800 1032030 49294020
18. NET ELECTRICAL ENERGY G: c.'L.R A 1 ED (MWH) 48548 9739 59Al 46221E44 Mb
19. UNIT SERVICE FACTOR 23.0 70.6 81.8
20. UNIT AVAILABILITY FACTOR 23.0 70.6 81.8 l 21. UNIT CAPACITY FACTOR (USING MDC NET) 13.4 67.2 78.4
22. UNIT CAPACITY FACTOR (USt% m R NET) 12.7 63.8 74.4
23. UNIT FORCED OUTAGE RATE 0.0 12.6 7.2
24. FORCED OUTAGE HOURS 0.0 291.9 7404.2
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH)

_______________NZe_____________________________________________________

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:__deX_252_1282____________

8708170363 870811 PDR ADOCK 05000282 R PDR

QEEB6IIUG_ Dele _SEEQEI DOCKET NO. $$-206_ UNIT PRAIRIE ISLAND UQ 2 DATE MAY 5, 1987 COMPLETED BY DALE DUGSTAD TELEPHONE 612-3PS-ii21 GEEE6IING_SIeIUS

i. UNIT NAME.-

EBeIBIE_IILeUD_NO _2 l C S T M PU ibET57 50~ l( ec 4 [ind / T l 4. NAMEPLATE RATING (510SS MWE). 593 l I

5. DESIGN ELECTRICAL RATING (NET MUE) 530 1

I

6. MAXIMUM DEPENDABLE CAPACETY (GROSS MWE): 531 I

i 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE) 500 1____________________1 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT GIVE REASON:__UQUE______________________________

9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):__UQUE______________
10. REASONS FOR RESTRICTIONS, IF ANY:__UQUE_______________________________

IBII_dQUIB YB:IC:DeIE CUdULeIIVE ii. HOURS IN REPORTING PERCOD 719 2879 108333

12. NUMBER OF HOURS REACTOR WAS CRITICAL 719.0 2879.0 94354.4

,13. REACTOR RESERVE SHUTDOWN HGURS 0.0 0.0 1516.1

14. HOURS GENERATOR ON-LINE 719.0 J79.0 93313.8
15. UNIT RESERVE SHUTDOWN HOURS

'O.0 0.0 0.0

16. GROSS THERMAL ENERGY GENERATED (MWH) i177216 4473074*

-1466T3252 N

17. GROSS ELECTRICAL ENERGY t.dNERATED (MWH) 385400 1573110 47390190
18. NET ELECTRICAL ENERGY GENERATED (MWH) 362883 1494497 379 44843e4+ 9S3
19. UNIT SERVICE FACTOR 100.0 100.0 86.1 i20. UNIT AVAILABILITY FACTOR 100.0 100.0 86.1
21. UNIT CAPACITY FACTOR (ll.'; r NG MDC NET )

100.9 103.8 82.8

22. UNIT CAPACITY FACTOP ( W F N' UER NET) 95.2 97.9 78.1 i

l23. UNIT FORCED OUTAGE RATE 0.0 0.0 3.4 l 24. FORCED OUTAGE HOURS 0.0 0.0 3253.1 l 25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH) ________________________________U_L_b__________________________-_---__-

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATEl_____U_2_e_______________

4 &DDS O lY

===:=}}