- _ _ - _ _ _ _ _
August 17, 1987 d
Docket No. 50-482 Mr. Bart D. Withers President and Chief Executive Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, Kansas 66839
Dear Mr. Withers:
SUBJECT:
USE OF REGULATORY GUIDE 1.147 (TAC 65604)
The NRC staff has completed its review of your request, dated June 2,1987, for authorization to use the code cases ' listed in Regulatory Guide 1.147 at Wolf Creek Generating Station.
Regulatory Guide 1.147, " Inservice Inspection Code Case Acceptability ASME Section IX Division 1,"
lists the ASME Code Cases that are acceptable to the staff for implementation in the Inservice Inspection Programs of light-water cooled nuclear power plants.
The actual ASME Code Case that is implemented should be specifically identified in the program.
The staff reviews the In_arvice Inspection Program and determines compliance to Section XI ASME Boilte and Pressure Vessel Code and applicable addenda as required by 10 CFR 50.55<'g).
The stai
- is currently concluding their review of the Inservice Inspection i
Program t ir the first ten year interval for the Wolf Creek Generating Station.
We note tLit tN request was not made to implement the ASME Code Cases listed in Regulatt.y Guide 1.147.
A revision of the Inservice Inspection Program is necessary in the event that one or more of the approved ASME Code Case is implemented in your program.
Sincerely l3!
Paul W. O'Connor, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects cc:
See next page LTR NAME: LETTER TO BART WITHERS DISTRIBUTION
- Docket. File NRC PDR Local PDR PD4 Reading F. Schroeder P. Noonan P. O'Connor OGC-Bethesda J. A. Calvo E. Jordan J. Partlow ACRS (10)
PD4 Plant File PD-9 fu PD-4 [ k PD-4 /) M -
PNoo a P0'Connor JCalvo 08/l1/87 08/17/87 08/r7/87 8708250137 870817 PDR ADOCK 05000482 P
l Mr. Bart D. Withers Wolf Creek Generating Station Wolf Creek Nuclear Operating Corporation Unit No. 1 cc:
Jay Silberg, Esq.
Mr. Gerald Allen Shaw, Pittman, Potts & Trowbridge Public Health Physicist 1800 M Street, NW Bureau of Air Quality & Radiation Washington, D.C.
20036 Control Division of Environment Chris R. Rogers, P.E.
Kansas Department of Health Manager, Electric Department and Environment Public Service Commission Forbes Field Building 321 P. O. Box 360 Topeka, Kansas 66620 Jefferson City, Missouri 65102 Mr. Gary Boyer, Plant Manager Regional Administrator, Region III Wolf Creek Nuclear Operating Corp.
U.S. Nuclear Regulatory Commission P. O. Box 411 l
799 Roosevelt Road Burlington, Kansas 66839 I
Glen Ellyn, Illinois 60137 Regional Administrator, Region IV Senior Resident Inspector / Wolf Creek U.S. Nuclear Regulatory Commission c/o V. S. Nuclear Regulatory Commission Office of Executive Director P. O. Box 311 for Operations Burlington, Kansas 66839 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 l
Mr. Robert Elliot, Chief Engineer Utilities Division Mr. Otto Maynard, Manager Licensing Kansas Corporation Commission Wolf Creek Nuclear Operating Corp.
4th Floor - State Office Building P. O. Box 411 Topeka, Kansas 66612-1571 Burlington, Kansas 66839 Resident Inspector / Wolf Creek NPS c/o U.S. Nuclear Regulatory Commission P. O. Box 311 Burlington, Kansas 66839 l
l l
l l
l 1