Forwards Application for Amend to License NPF-3,removing Safety Features Actuation Sys Response Times & Containment Isolation Time Requirements from Valves on Secondary Side of Steam Generators.Fee Paid
ML20237F804
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/07/1987
From: Shelton D
TOLEDO EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20237F807 List:
References
TAC-65685, NUDOCS 8708130165
Download: ML20237F804 (1)


Text

_. .

i . .

i l

! Docket No. 50-346 TOLEDO 'i License No. NPF-3 EDISON <

DONALD C, SHELTON Serial No. 1400 Vos Premdurt--Nuder l '

[419] P49 2399 August 7, 1987 i i

i United States Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555

Subject:

License Amendnent Application to Revise Technical Specification Sections 3/4.3.2 and 3/4.6.3 (TAC No. 65685) -

1 Gentlemen-  !

)

Enclosed we are transmitting an application for an amendment to Facility Operating License No. NPF-3 for the Davis-Besse Nuclear Power Station.

Unit No. 1.

I The enclosed application requests that the Davis-Besse Nuclear Power Station, Unit No. 1 Operating License. Appendix A Technical Specifica- l tions, be revised to reflect the changes attached. The proposed changes affect Technical Specification Sections 3/4.3.2, Safety System Instrumen-tation and 3/4.6.3, Contain'nent Isolation Valves. Specifically, the changes involve removing all Safety Features Actuation System (SFAS) response times cnd containment isolation time requirements, in the Tech-nical Specifications, from the valves on the secondary side of the steam generators. These valves aho receive redundant Steam and Feedwater Rupture Control System closure signals. By deleting the SFAS signal, unnecessary levels of redundancy will be eliminated and plant reliability will be improved by reducing the effect of an inadvertent SFAS actution.

Toledo Edison requests that this amendment be issued by October 30, 1987 and effective 30 days thereafter.

Enclosed is a check for $150 as required by 10CFR170.12(c) for a license amendment application.

Very tru yours,

/

CAB plf L J q 8708130165 870807 PDR ADOCK 05000346 k d9 $1 $

Enclosures P pga cc: DB-1 NRC Resident Inspectcr l A. B. Davis, Regional Administrator (2 copies)

A. W. DeAgazio, NRC/NRR Davis-Besse Project Manager State of Ohio THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDO OHIO 436b2

-