ML20237E827

From kanterella
Jump to navigation Jump to search
Summary of 980805-06 Meeting W/Babcock & Wilcox Owners Group Re TR BAW-2241, Fluence & Uncertainty Methodologies. List of Meeting Attendees Encl
ML20237E827
Person / Time
Issue date: 08/25/1998
From: Birmingham J
NRC (Affiliation Not Assigned)
To: Essig T
NRC (Affiliation Not Assigned)
References
PROJECT-693 NUDOCS 9809010206
Download: ML20237E827 (5)


Text

__

t

~

'cs:g 5L -.

UNITED STATES g'.

}

' NUCLEAR REGULATORY COMMISSION

! WASHINGTON, D.C. 20006-0001

-Q August 25, 1998-MEMORANDUM TO: Thomas H. Essig, Acting Chief Generic issues and Environmental Projects Branch -

l.

Division of Reactor Program Management Office of Nuclear Reactor Regulation l'

FROM:

Joseph L. Birmingham, Project Manager Generic issues and Environmental M

Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation

SUBJECT:

~

SUMMARY

OF AUGUST 5-6,1998, MEETING WITH THE BABCOCK &.

WILCOX OWNERS GROUP TO DISCUSS BAW-2241, " FLUENCE &

l UNCERTAINTY METHODOLOGIES" On August 5-6,1998, representatives of the Babcock and Wilcox Owners Group (B&WOG) met with members of the U.S. Nuclear Regulatory Commission (NRC) to present information on topical BAW-2241, " Fluence & Uncertainty Methodologies." The meeting was in response to a l

Request for Additional Information (RAl) sent by the NRC on April 8,1998.

The B&WOG reviewed their responses to an RAI previo'usly sent in January 1998 and also j '

explained their determination that a meeting was appropriate for this RAl. The staff agreed that the meeting was appropriate but asked the Owners Group to follow up with written responses for L

the RAl. The Owners Group then reviewed with the staff the approach used in BAW-2241 to determine vessel fluence. The approach used by the Owners Group determines vessel fluence L

analytically rather than estimating the fluence from sample examinations and extrapolating the results. The Owners Group then discussed each of the questions from the April RAI, including how the analytical results would be used, how the effect of increased plutonium in high burnup

/

- fuels is included in the source calculations, the effect of the core shroud former plates, the g

b relative importance of uncertainties in specific equations, and whether the methodology is to be applied to cores with partial length fuel assemblies. The B&WOG also discussed the buildup of fission produsts and their effect on dosimetry and on calculations.

k7)3

- At the conclusion of the meeting, B&WOG agreed to provide summary responses to the

. questions,in the RAI as discussed during the meeting. A list of those attending the meeting is attached.

Project No. 693,

g

.' Attachment L ds stated, cc w/att:~ See next page -

5

~

9809010206 980825' PDR TOPRP EMVBW fff ff}

C PDR 9

g m Ny

B&W Owners Group cc:

Mr. Robert Clark, Chairman B&WOG Materials Committee

Entergy Operations Inc.

. P.O. Box 1439 1448 S.R. 333 '

Russellville, AK 72801-0967-Mr. J. J. Kelly, Manager B&W Owners Group Services Framatome Technologies, Inc.

P.O. Box 10935 Lynchburg, VA 24506-0935 L.

l l

I l

l

)

l l

r 3

f.'

LL___

Attendees for B&WOG Meeting with NRC August 5-6,1998 NAME ORGANIZATION Robert Clark B&W Owners Group William Gray Framatome Technologies, Inc. (Framatome)

J. R. (Tuck) Worsham Framatome Eric Giavedoni Framatome S. Quinton King Framatome John Carew Brookhaven National Lab Ralph Caruso NRC\\NRR\\SRXB Lambros Lois NRC\\NRR\\SRXB Joseph Birmingham NRC\\NRR\\PGEB Attachment

1 As N ( /97/

Distnbutiorr Mtg. w/B&WOG Dated M

HARD COPY j..

  • Central File PUBLIC PGEB r/f

'~

OGC l

ACRS JBirmingham i

EMAIL SCollins FMiraglia BSheron GHolahan l

l LLois l.

RCaruso.

-TCollins

' JF;]e DMatthews TEssig FAkstulewicz '

l!,

i i

-l I

i ASgust 25i 1998 i

i MEMORANDUM TO: Thomts H. Essig, Acting Chirf G:neric issues end Environm:ntd Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation l

FROM:

Joseph L. Birmingham, Project Manager Original Signed By]

l Generic issues and Environmental Projects Branch l

Division of Reactor Program Management Office of Nuclear Reactor Regulation.

SUBJECT:

SUMMARY

OF AUGUST 5-6,1998, MEETING WITH THE BABCOCK &

WILCOX OWNERS GROUP TO DISCUSS BAW-2241, " FLUENCE &

UNCERTAINTY METHODOLOGIES"

. On August 5-6,1998, representatives of the Babcock and Wilcox Owners Group (B&WOG) met with members of the U.S. Nuclear Regulatory Commission (NRC) to present information on topical BAW-j 2241, " Fluence & Uncertainty Methodologies." The meeting was in response to a Request for

{

L Additional Information (RAI) sent by the NRC on ' April 8,1998.

l

\\

The B&WOG reviewed their responses to an RAI previously sent in January 1998 and also explained their determination that a meeting was appropriate for this RAl.= The staff agreed that the l

_ meeting was appropriate but asked the Owners Group to follow up with written responses for the l-

_ RAl The Owners Group then reviewed with the staff the approach used in BAW-2241 to determine L

vessel fluence. The approach used by the Owners Group determines vessel fluence analytically -

l rather than estimating the fluence from sample examinations and extrapolating the results. The l

Owners Group then discussed each of the questions from the April RAI, including how the analytical l

results would be used, how the effect of increased plutonium in high burnup fuels is included in the source calculations, the effect of the core shroud former plates, the relative importance of i

uncertainties in specific equations, and whether the methodology is to be applied to cores with l

partiallength fuel assemblies. The B&WOG also discussed the buildup of fission products and their ~

effect on dosimetry and on calculations.

l At the conclusion of the meeting, B&WOG agreed to provide summary responses to the questions in the RAI as discussed during the meeting. A list of those attending the meeting is attached.

Project No. 693 l

Attachment:

As stated DISTRIBUTION: See next page cc w/att: See next page Document Name: g:\\jlb\\08 56mtg j

OFFICE PGEB Aqi SC:P[Eh NAME.

JBirmingham:sw FheSicz DATE 8/1V98 8[,(I98 OFFICIAL OFFICE COPY o------___

1