Certificate of Compliance 6142,Rev 3,for Model Bettis Disposal Waste Package.Approval Record Encl
ML20237D990
Person / Time
Site: 07106142
Issue date: 12/22/1987
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20237D983 List:
References
NUDOCS 8712280076
Download: ML20237D990 (3)


Text

-

ragrurammmrarmursmmrammmrmmssrsumsmammsmastamramrm2Waramtzmswars NAC FORM 61s U.S. NUCLEAR REGULATORY COMMISSION

=

CERTIFICATE OF COMPLIANCE i

l io CrR n FOR RADIOACTIVE MATERIALS PACKAGES l Ta CERTIFICATE NUMBER b REVISION NUMBER

c. PACKAGE IDEN TIFICATION NUMBER d PAGE NUMBER
e. TOT AL fouMBER PAGES 6142 3

USA /6142/B(

)F 1

2

2. PREAMBLE
a. This certshcate is issued to certef y that the packagmg and contents desenbed in llem 5 below, rneets the applicable safoty standards set f orth in Title 10. Code of Federal Regulabons, Part 7t," Packaging and Transportation of Radioactive Malerial."
h. This certificate does not reheve the Consignor from Compliance with any requirement of the regulations of the U S. Department of Transportation or other apphCable regulatory agencies, including the government of any country through or 6nto which the package will be transported.

P

  • '"isEEES' S '*/fff,U '"' "^*'* ' ^ *^" #**"*'* "'OtE A 0 DE APT CATION 8

"^

^

J.

o I C N

EFO a

h U.S. Department of Energy Safety Analysis Report for Bettis Disposable h

Division of Naval Reactors Waste shipping container dated September 30s 1969.l Washington, DC 20585 y

'c. OOCx'ET NUweER i '

71-6142 5

4 CONDITIONS L

This cotihcate is conditional upon fulfilkng the requirements of 10 CF R Part 71, as app 4 cable, and the conditions specihed below.

..i..

E p

(a) Packaging y

b (1) Model No.: Bettis Disposable Waste (2) Description I

The packaging cons'ist's/of aidispbsableLconcrete vault enclosed in a y

E reusable steel overpack. yThe-concrete vault is a poured concrete i

block measurin'g 51"Lsiuare by 49" high. 1The inner cavity is centered b

1 in the vault _and may be one,ofs twoisizes:

15" square by 16" deep or h

structuralconcreteonthe~bo[smallercavitiissurroundedby18"of 27"'s'quare by 28" deep.

The ttom and sides.and by 15" on the top; the larger cavity islsurrou'nded
byil2"jonlthe bottom and: sides and by 9" p

cn thettop. TheJoverpack i's a"weldment of 2-1/2" by'5" rectangular n

steel tubes to 1/2" steel' plate and is sized and constructed to snugly enclose the concrete vault. ; The < lid is similarly constructed and is secured to the overpack by a. bolted and gasketed closure. The overall dimensions of,the package are 64" by 64".

The gross weight is approxi-y mately 16,000 pounds.

p (3)

Drawings kj g

The packaging is constructed in accordance with Westinghouse Electric E

Corporation Drawing Nos. 945F976, Rev. 4; 930C940, Rev. 4 and 976C870s f

Rev. 3.

y ni bi I,

c&2280076871222ADock 07206142 I

l PDR Y

P I

I l

r:, n n:

CONDmoNS (continued)

C N

l Page 2. Certificate No. 6142 - Revision Noc Docket No. 71-6142 l

1 1

I (b) Contents i

i (1) Type and form of material l

1 Byproduct and special nuclear material in the form of radioactive i

waste which has been packaged-in smaller cans or pails or as.unpackaged i solid waste sealed in poured concrete.

1 1

(2) Maximum quantity of material per package l

N 110 equivalent grams of U-235, where the number of equivalent grams of y

U-235 is determined;by th'eiequation:

1.0 x gram U-235 + 1.4 x grams p

U-233 + 1.6 x grams

FissileClass()(,>-

4 4' h W

s3 III E

(c)

+

Maximumnuisberofpackagespershipment

  • g";;.g' j

2 g

.-j i

u.

6.

Expiration date: December 31, 1992.

,pp i

p47.h f,k O

1, REFERENCE-

.c 7 -

-(

)

y

-. 3 % (.

.. l.:m.f.,, 3A w.y i

s Safety Analysis jReport for Bettis, Disposable'.Wa'steishipping container, WAPD-0(A0)-5029 i Jn r.qy dated September 30,196961 N ;% 4 % i j g / p+f i

> y.

6.i ?

U V..

?

i

, y9 1,iQ$IFOR[THEU.SDNdCLEARREGULATORYCOMMISSION l

AgW u-

~ - O..

,e g-f (

's i

D, 'm c g

g j

!)f l

,es Charles E. MacDonald.. Chief

  • /

Transportation Branch

.Divisioniof Safeguards and g

Transportation, NMSS-o Date: DEC 2 21987 1

i W

I,

- ~ ~

. _........ aa,,

nw.............,,,,,,,,,,},i

)

/

UNITED STATES NUCLEAR REGULATORY COMMISSION n

h WASHINGTON, D. C. 20555 k

j/

g Transportation Branch Approval Record Model No. Bettis Disposal Waste Package Docket No. 71-6142 Revision No. 3 By application dated November 10,1987(G#87-3254), Division of Naval Reactors, ll.S. Department of Energy, requested renewal of Certificate of Compliance No. 6142. No changes have been authorized to the package design since approval of the latest application dated September 30, 1969.

The certificate of compliance has been renewed for a five year tenn which expires December 31, 1992.

Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS Date:

DEC 2 21997

_ _. _ _ _ _ _ _ - _ _ _ _. _ _ _ _ _ _ _. _ _ _ _ _ _