_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ ____ _ _-__-_ ____ ______ _ _ - _ _

August 20, 1998 Mr. D. N. Morsy Vice Prasident - Farl&y Proj ct Southern Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201-1295

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING GENERIC LETTER 97-05, " STEAM GENERATOR TUBE INSPECTION TECHNIQUES" RESPONSE -

JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. MA0464 AND MA0465)

Dear Mr. Morey:

By letter dated March 6,1998, you submitted the Joseph M. Farley Nuclear Plant, Units 1 and 2, Generic Letter 97-05,90-day response. The staff has reviewed your submittal and determined that additional information is required. The enclosure identifies the requested additional information (RAl) needed.

The enclosed RAI has been discussed with Ed Carmack of your staff. A target date for your response has been agreed upon to be October 23,1998. Should a situation occur that prevents you from meeting the target date, please contact me at (301) 415-2426.

Sincerely, ORIGINAL SIGNED BY:

Jacob 1. Zimmerman, Project Manager Project Directorate 11-2 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation Docket Nos. 50-348 and 50-364

Enclosure:

As stated cc w/ encl: See next page Distribution:

Docket File PRush PUBLIC EMurphy PDil-2 RF ADromerick p

JZwolinski ACRS 1

HBerkow OGC

{

LPI co RI I

PSkinner, Rll DOCUMENT NAME: G:\\FARLEY\\MA0464.R Al To receive copy of document, indicate in box: "C = Copy w/o enci "E" = Copy w/enci "N" = No copy OFFICE PM:PDlJf2f, lE PM.PDil-2 ] ] N LA:PDiffli tj NAME JZIMp6E@lAN:en LBERRY \\/ \\\\

HBERKO#

{

(DATE Bifp/08 8/00/98 "'

8/Je /98

)

OFFICIAL RECORD COPY 9808250129 990820 PDR ADOCK 05000348 G

PDR L_-__-___________

l s& C'!v w

4 UNITED STATES f

j NUCLEAR REGULATORY COMMISSION s

WASHINGTON, D.C. 2006HOM

%, * *-***p' August 20, 1998 Mr. D. N. Morey Vice President - Farley Project Seuthern Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201-1295 l

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING GENERIC LETTER 97-05, " STEAM GENERATOR TUBE INSPECTION TECHNIQUES"- JOSEPH M.

FARLEY NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. MA0464 AND MA0465)

Dear Mr. Morey:

By letter dated March 6,1998, you submitted the Joseph M. Farley Nuclear Plant, Units 1 and 2, Generic Letter 97-05,90-day response. The staff has reviewed your submittal and determined that additional information is required. The enclosure identifies the requested additional information (RAl) needed.

The enclosed RAI has been discussed with Ed Carmack of your staff. A target date for your response has been agreed upon to be October 23,1998. Should a situation occur that prevents you from meeting the target date, please contact me at (301) 415-2426.

l Sincerely, l

Jacob 1. Zi merman, Project Manager Project Directorate ll-2 Division of Reactor Projects - 1/il Office of Nuclear Reactor Regulation i

Docket Nos. 50-348 and 50-364

Enclosure:

As stated cc w/ encl: See next page l

Joseph M. Farley Nuclear Plant cc:

Mr. L. M. Stinson Rebecca V. Badham General Manager -

SAER Supervisor Southern Nuclear Operating Company Southern Nuclear Operating Company Post Office Box 470 P. O. Box 470 Ashford, Alabama 36312 Ashford, Alabama 36312 Mr. Mark Ajiuni, Licensing Manager Southern Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201-1295 Mr. M. Stanford Blanton Balch and Bingham Law Firm Post Office Box 306 1710 Sixth Avenue North Birmingham, Alabama 35201 Mr. J. D. Woodard Executive Vice President Southern Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201 State Health Officer Alabama Department of Public Health 434 Monroe Street Montgomery, Alabama 36130-1701 Chairman Houston County Commission Post Office Box 6406 Dothan, Alabama 36302

)

l Regional Administrator, Region ll j

U.S. Nuclear Regulatory Commission i

Atlanta Federal Center I

61 Forsyth Street, S.W., Suite 23T85 Atlanta, Georgia 30303 Resident inspector U.S. Nuclear Regulatory Commission 7388 N. State Highway 95 Columbia, Alabama 36319 l

i

Raouest for Additional Information i

Generic Letter 97-05 Resoonse

(

l Southern Nuclear Ooeratina Comoanv. Inc.

1 Joseoh M. Farlev Nuclear Plant. Units 1 and 2 l

Docket Nos. 50-348 and 50-3S4 During the review of Southern Nuclear Operating Company, Inc.'s (SNC's) response to Generic Letter (GL) 97-05, " Steam Generator Tube inspection Techniques," the staff noted one area that required additional clarification in order k assess the adequacy of inspection techniques employed at the Joseph M. Farley Nuclear Plant, Units 1 and 2 (Farley). In this regard, please provide the following information to the NRC.

The NRC staff noted a potential inconsistency with the stated practice employed at Farley for dispositioning manufacturing burnish mark (MBM) indications during steam generator tube inspections. Specifically, it was stated that a rotating coil examination is used to distinguish between MBMs and other modes of tube damage. Discuss the qualification that enables the differentiation between MBMs and other volumetric forms of tube degradation (e.g.,

intergranular attack), or provide evidence from pulled tubes or industry experience that supports your practice of characterizing MBMs through eddy current insnection techniques. In the response to GL 97-05, SNC indicated that prior inspection data is reviewed to disposition potential MBM indications. State in your response whether it is the practice at Farley to review preservice or the most recent inspection data to determine if indications were evident in the past.

Enclosure I

_ _ ____ _-__________ -