Informs That NRC Staff Has Review Listed Submittals by Licensee Re GL 97-05, SG Tube Insp Techniques
ML20155G942
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 11/04/1998
From: Jacob Zimmerman
NRC (Affiliation Not Assigned)
To: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
References
GL-97-05, GL-97-5, TAC-MA0464, TAC-MA0465, TAC-MA464, TAC-MA465, NUDOCS 9811090262
Download: ML20155G942 (3)


Text

_

Mr. D. N. Moray Vice Pr:sident - Fcriey Proj:ct Southem Nuclear Operr. ting l

Company, Inc.

f Post Office Box 1295 Birmingham, Alabama 35201-1295 l

SUBJECT:

REVIEW OF REPONSE TO GENERIC LETTER 97-05 FOR JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. MA0464 AND MA0465) l

Dear Mr. Morey:

The U.S. Nuclear Regulatory Commission (NRC) staff has reviewtd the submittals by Southern Nuclear Operating Company, Inc. (SNC) dated March 6 and October 12,1998, regarding Generic Lotter (GL) 97-05," Steam Generator Tube Inspection Techniques." The focus of GL 97-05 was to verify that licensee steam generator tube inspection practices were consistent with existing regulator / requirements and plant licensing basis. SNC's responses to the GL included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at the Joseph M. Farley Nuclear Plant (FNP),

Units 1 and 2. The NRC staff's review of the responses did not identify any concerns with the steam generator tube inspection techniques employed at FNP that would indicate that SNC is not in compliance with the current licensing basis for this facility.

3

\\

Sincerely, SIGNED BY:

0 ORIGINAL Jacob 1. Zimmerman, Project Manager Project Directorate Il-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket Nos. 50-348 and 50-364 bb NI cc: See next page Distribution:

Docket File PUBLIC ADromerick OGC PD 11-2 Rdg.

LPlisco, Rll EMurphy ACRS JZwolinski PSkinner, Rll PRush l

To receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" o Copy with attachment / enclosure "N" = No copy OFFICE PM:@l-2 l

LA:PDi(2n D:PA@ l l

l NAME J74rify6rman:cn LBerry \\g HBerR0w I

DATE

// / fl98

\\\\ / V/98 '

il /1 /98

/ /98

/ /98 DOCUMENT NAME: G:\\FARLEY\\MA0464.LET OFFICIAL RECORD COPY 9811090262 981104 PDR ADOCK 05000348 G

PDR

E UNITED STATES

[

g NUCLEAR REGULATORY COMMISSION 5

j WASHINGTON, D. C. 20555 k.,.... #'

November 4, 1998 Mr. D. N. Morey Vice President - Farley Project Southem Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201-1295

SUBJECT:

REVIEW OF REPONSE TO GENERIC LETTER 97-05 FOR JOSEPH M. FARLEY NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. MA0464 AND MA0465)

Dear Mr. Morey:

The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the submittals by j

Southem Nuclear Operating Company, Inc. (SNC) dated March 6 and October 12,1998, regarding Generic Letter (GL) 97-05, " Steam Generator Tube Inspection Techniques." The focus of GL 97-05 was to verify that licensee steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing basis. SNC's responses to the GL included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at the Joseph M. Farley Nuclear Plant (FNP),

Units 1 and 2. The NRC staff's review of the responses did not identify any concems with the 4

steam generator tube inspection techniques employed at FNP that would indicate that SNC is not in compliance with the current licensing basis for this facility.

Sincerely, l ^

acob 1. Zimmerman, Project Manager Project Directorate 11-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket Nos. 50-346 ard 50-364 1

cc: See next page

Joseph M. Farley Nuclear Plant cc:

Mr. L. M. Stinson Rebecca V. Badham General Manager-SAER Supervisor Southem Nuclear Operating Company Southem Nuclear Operating Company Post Office Box 470 P. O. Box 470 Ashford, Alabama 36312 Ashford, Alabama 36312 Mr. Mark Ajiuni, Licensing Manager Southem Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201-1295 Mr. M. Stanford Blanton Balch and Bingham Law Firm Post Office Box 306 1710 Sixth Avenue Noith Birmingham, Alabama 35201 Mr. J. D. Woodard Executive Vice President Southern Nuclear Operating Company Post Office Box 1295 Birmingham, Alabama 35201 State Health Officer Alabama Department of Public Health 434 Monroe Street Montgomery, Alabama 36130-1701 Chairman Houston County Commission Post Office Box 6406 Dothan, Alabama 36302 Regional Administrator, Region ll U.S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth Street, S.W., Suite 23T85 Atlanta, Georgia 30303 Resident inspector U.S. Nuclear Regulatory Commission -

7388 N. State Highway 95 Columbia, Alabama 36319 I

l