ML20237B094

From kanterella
Jump to navigation Jump to search
Forwards Peaking Factor Limit Rept for Mcguire Unit 1 Cycle 5:RAOC & Base Load Operation. Set of Data Covering Three Specific Burnup Steps Provided
ML20237B094
Person / Time
Site: McGuire 
Issue date: 12/11/1987
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20237B097 List:
References
NUDOCS 8712160023
Download: ML20237B094 (2)


Text

.

DUKE POWER Gonnwy P.O. Box 3318D CHARLOTTE. N.C. 28242 HAL11.TUGKER TE LE PHONE vaca rummunrwr (704)073-4531 NUCLEAN Peopts0 TION December 11, 1987 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555

Subject:

McGuire Nuclear Station, Unit 1 Docket No. 50-369 McGuire 1/ Cycle 5 Reload-Peaking Factor Limit Report

]

I Gentlemen:

The McGuire Unit 1 end of cycle 4 refueling outage has been completed with cycle 5 startup (initial criticality) achieved on November 12, 1987.

This reload was accomplished under the provisions to 10CFR 50.59.

l l

Pursuant to Technical Specification 6.9.1.9, attached is the Peaking Factor Limit J

Report for McGuire Unit 1/ Cycle 5.

This report provides the W(Z) functions that 1

o be used for RAOC and base load operation during Cycle 5, and the value for J

are APL For both RAOC and base load operation, a set of data covering three l

specific burnup steps is provided which permits the determination of W(Z) at any cycle burnup through the use of three point interpolation.

The information for base load operation has been obtained using a +5 percent AFD about a measured target in the power interval between 80% and 100% of rated thermal power.

Fig-ures 1-3 are the W(Z) functions appropriate for RAOC operation and Figures 4-6 are the W(Z) functions appropriate for base load operation.

The appropriate W(Z) function is used to confirm that the heat flux hot channel factor, Fq(z), will be limited to the values specified in the Technical Specifications.

Very truly yours, Hal B. Tucker PBN/66/j gc Attachment 8712160023 871211

/

PDR ADOCK 05000369 y

P PDR

1 L______________.._______

Document Control Desk December 11, 1987 Page 2 xc:

Dr. J. Nelson Grace, Regional Administrator U.S. Nuclear Regulatory Commission - Region II 101 Marietta Street, NW - Suite 2900 Atlanta, GA 30323 Mr. Darl Hood, Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. W.T. Orders NRC Resident Inspector McGuire Nuclear Station J

l l

__- ____ _ -