ML20236Y242

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to 8031-P-504, Preservice Insp Program, Per SER Confirmatory Item 12C.Preservice Exam Requirements of Section XI of ASME Boiler & Pressure Vessel Code & plant- Specific Requests for Relief Identified
ML20236Y242
Person / Time
Site: Limerick 
Issue date: 09/10/1987
From: Kowalski S
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Butler W
Office of Nuclear Reactor Regulation
Shared Package
ML20236Y243 List:
References
NUDOCS 8712110194
Download: ML20236Y242 (1)


Text

?aF @, t/c s

/

.. /

PHILADELPHIA A ELECTRIC COM PANY 2301 M ARKET STREET P.O. BOX 8699 PHILADELPHIA A. PA.19101 SEP 10198/

S. J. MOW A LSKI

  • /lc E-P R E SI D E NT smeinssesme Ano massanca Mr. Walter R. Butler Director Docket No.: 50-353 BWR Project Directorate No. 4 Division of BWR Licensing U.S. Nuclear Regulatory Conmission Washington, DC 20555

Subject:

Limerick Generating Station, Unit 2 i

l j

Preservice inspaction Program

Attachment:

Docunent No. 8031-F 504 Limerick Generating Station, Unit 2 Preservice Inspection Program, Rev. 1 Flies:

GOVT 1-1 (NRC)

GEN 5-1 (P-504)

Dear Mr. Butler:

We are pleased to provide the attached Preservice Inspection Program in accordance with SER Confirmatory item #12C.

The attachment identifies the preservice examination requirements j

of Section XI of the ASME Boller and Pressure Vessel Code along with additional examination requirements derived from applicable USNRC guidance doct.ments. Pursuant to SER CI #12C, the attachment includes l

plant unique requests for relief from impractical preservice examination requirements. Additional requests for relief may result from the ongoing review of the preservice examination data. These additional requests will be addressed as a revision to the attachment to be submitted at the canpletion of the preservice inspection.

Shoulo additional information be required, please do not hesitate to contact us.

Sincerely ['

8712110194 070910 PDR ADOCK 05000353 O

PDR DLS/pdO8198705

/(0 h/

\\

Attachment t

Copy to:

W. T. Russell,. Regional Administrator USNRC Region I R. A. Granm, Limerick Generating Station, Unit 2 USNRC Resident inspector

Specification 8031-P-504 LIMERICK GENERATING STATION l

UNIT 2 PRESERVICE INSPECTION PROGRAM PREPARED FOR PIIILADELPHI A ELECTRIC COMPANY BY BECHTEL WESTERN POWER CORPORATION SAN FRANCISCO, CALIFORNIA Incorporated additional PF.fo ccrmts, g

Wh NS-61 issued for PECo suhnittal to ?T Jflif/7 Issued for NRC submittal

% g j

DATE DESCRIPTION QE BY CHKD P.E.

g 8712110215 870910 PDR ADOCK 05000353 G

PDR Sheet i

_ _..... _...