ML20236V663
| ML20236V663 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 08/31/1987 |
| From: | PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC |
| To: | |
| Shared Package | |
| ML20236V505 | List: |
| References | |
| NUDOCS 8712040455 | |
| Download: ML20236V663 (135) | |
Text
{{#Wiki_filter:_ _______ __________ _ _ _ __ _ _ _ _ LIMERICK GENERATING STATION UNIT ONE AND COMMON PLANT
SUMMARY
OF ASME SECTION XI REPAIRS AND REPLACEMENTS COMPLSTED FROM SEPTEMBER 28, 1984 TO AUGUST 31, 1987 REPORT NO. 1 c: h G
i Limerick Generating Station Unit One and Common Plant Summary of ASME Section XI Repairs and Replacements Completed From September 28, 1984 To August 31, 1987 1
l Summary of ASME Section XI Repairs and Replacements During the period from September 28, 1984 to August 31, 1987, ASME Section XI Repairs and Replacements were performed at Limerick Generating Station, Unit One and Common Plant. These repairs and replacements were completed in accordance with the requirements of ASME Section XI 1980 Edition with Addenda through Winter 1981. In accordance with ASME Code Case N-308 these repairs and replacements were documented on ASME Form NIS-2. This report documents the ASME Section XI repairs and replacements completed during the aforementioned period and is organized as follows: : ASME Section XI Repairs and Replacements, Description of Work Performed. Attachment.2: Completed NIS-2 Forms It should be noted that the dates listed on the NIS-2 Forms are not necessarily the dates on which the actual repairs or replacements were performed, but indicate completion of all activities which support the repairs or replacements. Detailed work packages which support these repairs and replacements have been sent to Nuclear Records Management and will be retained for the life of the plant. l l I
i ATTACHMENT 1 ASME Section XI Repairs and Replacements Description of Work Performed 1 __.m____._m__.___m_..______ .m-.u._ _-_m_~
Page 1 of 3 Summary of ASME Section XI Repairs and Replacements Date of NIS-2 System No. Description of Work Performed 12/20/84 M-01 Repair weld EBB-106-2-1, FW50R1 for min. wall thickness violation. 02/07/86 M-ll Installed restriction flow orifices FO-ll-109A, B, C, D. 07/23/86 M-ll Replaced nuts on anchor bolts for HBC-292-H902, H903. 08/20/87 M-ll Replaced orifice FO-ll-007A per Mod. 5136. 09/15/87 M-ll Replaced supply piping to A loop chiller 0AKll2 per Mod. 5135. 09/16/87 M-11 Added isolation valve 11-1087 to separate ESW loops per Mod. 5132. 09/23/87 M-ll Replaced supply and return lines to A&C Core Spray pump compartment unit coolers per Mod. 5134. 09/23/87 M-ll Replaced RCIC pump compartment unit cooler isolation valves 11-1019, and 11-1021 per Mod. 5328. 11/15/85 M-20 Modified diesel generator exhaust silencer drain piping SP-HBC-1AS-575. 09/28/84 M-41 Repaired min. wall thickness violation I on Feedwater System weld DBB-103-1, FW60. 09/28/84 M-41 Repaired min. wall thickness violation on Feedwater System welds DBA-ll2-2, ) FW58 and FW66. ] 03/28/85 M-41 Replaced RPV head stud, nut, and washer in location #74. 02/07/85 M-41 Removed pipe support and welds which were installed on the RPV. i 07/25/86 M-41 Replaced all Main Steam System relief valves. L- ._____.___.__.__.______a
t 1 Page 2 of 3 Summary of ASME Section XI Repairs and Replacements Date of NIS-2 System No. Description of Work Performed 07/25/86 M-41 Replaced Main Steam System relief valve studs and nuts. 08/25/87 M-41 Replaced all Main Steam System relief valves. 09/11/87 M-41 Replaced Main Steam System relief valve studs and nuts. 06/24/86 M-44 Added bypass loop around regenerative heat exchanger per Mod. 964. 10/15/84 M-48 Installed level transmitters LT-
- IN010A, B,
E, F to tank 10T-204. 10/31/85 M-48 Replaced explosive actuator parts of valve XV-48-lF001A. 09/23/87 M-49 Rotated valve HV-49-lF022 180 deg. and reinstalled per Mod. 5040. 04/10/85 M-50 Replaced couplings and valve SP-HBB-150-El-lF028. 08/16/85 M-50 Replaced flow orifices Fo-50-lD006A, and B. 09/28/84 M-51 Repair welded RHR Heat Exchanger 2BE-205 nozzles N1 and N2. 04/17/85 M-51 Repair welded RHR pipe GBB-ll8-4-6. 05/09/85 M-51 Replaced shims on pipe supports HBC-508-H4, H5, and HBC-509-H4, H6. 08/06/86 M-51 Installed flanges on wetwell spray ring headers GBC-112. 08/20/87 M-51 Installed RHR test return line orifices per Mod. 24. 10/15/84 M-52 Repaired min, wall thickness violation on weld GBB-ll2-2, FW61Rl. 10/15/84 M-52 Repaired lack of fusion in weld GBB-112-3, FW55.
f Page 3 of 3 Summary of ASME Section XI Repairs and Replacements Date of NIS-2 System No. Description of Work Performed i 03/24/87 M-53 Replaced carbon steel RHR/ Fuel Pool { Cooling intertie with stainless steel. ~10/21/85 M-55 Replaced HPCI flow orifices FO 1D010A and B. 09/11/87 M-55 Replaced gasket retaining ring on valve HV-55-lF003. 12/31/85 M-56 Replaced HPCI gland seal condenser relief valve PSV-56-lF018. 07/28/87 M-56 Replaced bonnet on valve HV-56-112. 10/09/84 M-57 Welded ring plate to stuffing box on valve 57-1123. ) 10/09/84 M-57 Welded ring plate to stuffing box on valve 57-1124. 10/09/84 M-57 Welded ring plate to stuffing box on valve 57-1125. 10/09/84 M-57 Welded ring plate to stuffing box on valve 57-1126. 07/13/87 M-57 Added redundant isolation valves to the hydrogen recombiner per Mod. 34. 09/30/87 M-103 Replaced miscellaneous snubbers. l l
ATTACHMENT 2 Completed NIS-2 Forms l l
/ l' v' FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company December 20, 1984
- 1. Owner Date nome 2301 Market Street, Philadelphia Pa.19101 Sheet 1
of 1 Address
- 2. Plant Limerick Generating Station unit I Name P.O. Box A.Sanatoga Branch.Pottstown.Pa.
Bechtel Job #8031 19464 Receir Organization P.O. No., Job No., etc. ^ " ' ' "
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol Stamp Not Applicable Name Authorization No. Not Applicable 50 Beale Street. San Francisco. Ca. Expiration Date Not Applicable Address
- 4. Identification of System hin Steam 83A N-241 N-226
- 5. (a) Applicable Construction Code 19 *
- Edition, AddendaJ606. N-316 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 81 N-252 N-308
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME C.)
Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) Piping System Southwest 2875 EBB-106 'Fabr. & (EBB-106-N/A FSK-EBB-106 1973 Repair Yes Weld. Co. 2-1) FWX50R1 l l
- 7. Description of work Repair weld area of pipe that violates minimum wall thickness per l
FSK-EBB-loo-Z Sheet 1 or 1 4 i Nominal Operating Pressure O.p
- 8. Tests Conducted: Hydrostatic Pneumatic N/A Other O Pressure N/A psi Test Temp.
j NOTE: Supplemental sheeta in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa. { tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the ttip of this form. i (12/82) This Form (E00030) may be obtained from the Order D2pt., ASME,345 E. 47th St., New York, N.Y.10017 \\ .e i ~ - _ _ - - _ - - _ _ -
r ~y FORM NIS 2 (Back) Repair was performed and completed ner ASME Section XI renair olan 9 Remarks Applicable Manufacturer's Data Reports to be ettsched ' 8031-FM-47. Rev. 0 & Rev. 1 CERTIFICATE OF COMPLIANCE Repair conforms to the rules of the We certify that the statements made in the report are correct and this ASME Code, Section Xl. Not'Aeolicable Type Code Symbol Stamp Certificate of Au orization No. Nor Ann 14enh1* Expiration Date Noe Annlicable I[ s;gned _ _ /X4 B.C.T. Project Constriction Date M 19 Owner or Owner's Designee, Title g, CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of PannmvlVA"ia and employed byThe Fnttford Steam Boiler 'nsnection 6 of Hartford. Conn. have inspected th NhnNtk dhMAbed I* U* N dU~ U and state that to in this Owner's Report during the period to the best of my knowledge and belief, the Owner has per4ormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection, I Commissions / Inspector's Signature National Board, State, Province, and Endorsements M 19 U Date (13/82) .) _b
E o FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Februarv 7, 1986
- 1. Owner Philadelphia Electric Comoanv oate N eene 2301 Market Street. Philadelphia PA 19464 Sheet 1
of 1 Accross
- 2. P! ant Limerick Generating Station unit I
Name P.O. Box A. Sanatoca' Branch Pottstown Bechtel Job #8031 ^*c' PA 19464 R*a organization P.o. No., Job No., etc. Not Applicable Bechtel Construction, Inc. Type Code Symbol Stamp
- 3. Wdrk Performed by Authorization No.
Not Applicable 50 Beale Street. San Francisco CA Expiration Date Not Aeolicable Ad dress ECer'2encv Service Eater S/U 54A PSID 8031-M-11 4 identification of System N308 cee,'Cm
- 5. (a) Applicable Construction Code 19
- Edition, Addenda, (b) Applicable Edition of section XI Ut'lized for Repairs or Replacements 19 80 - Winter 81
- See Spec. 8031-F360 Rev. 9
- 6. Identification of Components Repaired or Replaced and Rectacement Components ASME Ccde
- Repaired, Stamped National Name of Name of Manufacturer Board O ther Year R eplaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement or No) Restr. Orifice Colonial Replace-FO 109 A - Machine Co. 'Ht# 13541 N/A N/A N/A cent No 'Restr. Orifice' Colonial Replace-lFO-11-1093 Machine Co. Ht# 13541 N/A N/A N/A ment No Restr. Orified Colonial i Replace-FO-11-109C l Machine Co. jHt# 13541 N/A N/A N/A ment No 1 Restr. Orifice Colonial Replace-FO-11-109D Machine Co. He# 13541 N/A N/A N/A ment No i Installed restriction orifices on Emergency Service Water lines.
- 7. Description er work Hydrostatic 0 Pr.eumatic 0 Nominal Operating Pressure @
- 8. Tests Conducted:
Other Pressure 120 psi Test Temp. 95 'F Bench Test: 170 psi 78 F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in x 11 in., (2) informa-tion in items 1 througn 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. ' '(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i _ _ = _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ - _ _ _ ____a
Y e FORM NIS 2 (Back) Replacement was performed and comiered re-AcMr c;e rinn YT g, nem,rks AppHcable Manuf acturer's Data Reports to be attached replacement plan 8031-FM-46 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct one thisreplacement conforms to the rules of the f apeir or replacement ASME Code, Sectic n XI. l Not Apolicable Type Code Symool Stamp Not Applicable Not Applicable Expiration Date Certificate of Authorization No. N '2 & MMA BCI Proiect Date 19 Signed .4 ownet or owner s oesignee, Titi. Construction Mgr. CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, hold;ng a vand commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Pennsylvania ,ne mpioy,eey-_The Hartford Steam Boiler Inspection & og or Province of insoected thkUleMF868 Ncticed Hartford, Conn. hav 'D . and state that to in this Owner's Report during the pericd to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Cooe, Se: tion XI. By signing this certificate nejther t e inspector nor his employer makes any warranty, expressed or implied, concernirg the h examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personalinjury or property damege or a loss of any kind arising from or connected with this inspection. 'd ' C L' Commissions * * 'Y + inscector's Sigr ature National BoarrJ, State, Province, ano Endorsements /Y.c Y 19 *f( Date O2/32) v
- khs NS
. :,I i 86-02 ' egf.e. m ma: .1 - m.:er.:~-_ -_- . - _: m=
- _ r =
.~
- ..;T [ :-:.~f-} -
~ ~ ~ FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1 As Required by the Prr> visions of the ASME Code Section XI oste July 23,1986 Philadelphia Electric Company ,, % n,, l name 2301 Market Street Philadelphia, PA.19101 Sh.et 1 of 1 N Adorose
- 2. Pi n, Limerick Generating Station unit I
ne.e P.O. Box A, Sanatoga Branch, Pottstown, PA Bechtel Job #8031 An em ]g4g4 mena organi:Mion P.O. No., Ja No, Mc.
- 3. Work Performed by Bechtel Construction, Inc.
Type Code Symbol Stamp Nnt Annlicable. Name ~ Nnt Annlicahip Authorization No, 50 Beale Street, San Francisco, CA. Expireuen cete Not Annlicahlp Address
- 4. Identification of System Emergency Service Water, P&ID 8031-M-11. Design Soec-M- 511 t
5 (a) Applicable Construction Code 19
- Edition, Addenda. 1606 Code case (b) Applicable Edition of Section XI utilized for Repairs or Repiscements 19 80. Winter 81
- See Spec. 8031-P-360 Rev. 9
- 6. Identification of Components Repaired or Replaced and Replace;nent Components ASME Co6e National
- Repaired, Stemped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement or No) If Hex Nuts Rehlace-A-325 (2) N/A N/A N/A N/A N/A mont N$ 1 i
- 7. Descriptiori ef Work Replaced one nut on arouted-in-bolts on hancert HRC ?Q7 Hon? A HBC-292-H903 es described on Operations NCR No. '.35-15. ~
- 8. Tests Conducted: Hydrostatic 0 Pa um tic 0 Nominal Operating Pressura Other Pressure N/A psi Test Temp.
N/A 'F q NOTE: Supplemental sheets in form of lists, sketches, or drawings iney be used, provided (1) size is 8% in. x 11 in., (2) Informs. tion in items 1 througn 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 1,1y82), This f,orm (E00030) may be obtained from the O der Dept., ASME,345 E. 47th St., New York, N.Y.10o17 N ~ ~_ F ~.
z .,,.hk . &Yl IRS!fb;Wkt&^ 2;,~- .:=*". $$ff.O!.Qy& m. 1 m.m. l w w..,wm w ~.r.u. u-ww.:. Q%r-e-< ~~.w. yr.py y.r. \\ a .. s..,n c h
- ~.- -
E, y. f
- ~
-? { _ q <; '. . d, j.; "t B L)A. j 'f4; ~, .... ' 'd t:
- Pa ;
w,' ;a. { ...e i FORM NIS 2 (Back) {
- g. Rom.rks _This NIS-2 Data Reoort documents the replacement of (2) nuts as f
Applicable Manufacturers Osta Maporte to De etteched renuired hv Onorati ns Nonennfomance Rennet I(&l5.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this.ren1 a comen t conforms to the rules of the ASME Code, Section XI.
~
Type Code Symbol stamp Not Annlicablo
.NotJqpliCpblp Not Applicable Expiration oste Certificate of A + 1 n
/
S.
. str tion Mgr.
dcv 23 in B6 B.C Pr eC ownsrarown.
Commissions T
inn tor's Signatur National Board. State' Province, and E ncornernents Date M/ [
19 C 1
0 2/82) j l
)
l l
I l
1
e i
' FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
,, % n., Philadelphia Electric Company o,,,
September 23, 1987 Name 9
'2301 Market St.
Philadelphia, PA 19101 Shut 2
of Adoross
- 3. Plant Limerick Cenerating Station Unit One Name P.O. Box A Sanatoga Branch PECo Ao aron espear orpenizetton P.o. No, Job Noy etc.
Pottstown, PA
- 3. Work Performed by Philadelphia Electric Company Type Code Symbol stamp Not Applicable Authorization No, Not Applicable Name 2301 Market St., Philadelphia, PA 19101 Expiretion osto Not Applicable Address 4, identification of System Emergency Service Water - Spec. 8031-M-511, N240, N316 Q. (a) Applicable Construction Code 19
- Edition, Addende, 1606 Code C (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 with addenda through winter 1981 l
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Nationel
- Repelred, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No, No.
Identification Built or Replacement or No) IDCN#001 Babcock & Replace HBC-141-1 Wilcox 400874 N/A PC SXA N/A ment No IDCN#001 Babcock & Replace HBC-141-1 Wilcock 400873 N/A PC 6X N/A ment No IDCN#001 Replace HBC-141-1 Ladish DX6B N/A PC 7X N/A ment No IDCN#001 Babcock & Replace HBC-141-1 Wilcox 400873 N/A PC 8X N/A ment No IDCN#001 Replace HBC-141-1 Tube Turn W8928 N/A PC 9X N/A ment No IDCN#001 Babcock & Replace HBC-141-1 Wilcox 400873 N/A PC 10X N/A ment No IDCN#001 Replace HBC-141-1 Ladish DX6B N/A PC 11X N/A ment No IDCN#001 Babcock & Repalce HBC-141-1 Wilcox 400873 N/A PC 12X N/A ment No av - Replace IDCN#001 Anchor E-A121 1 HBC-141-1 Darling /Valvi N/A 11-1025A 87 ment No IDCN#001 Babcock & Repalce HBC-141-1 Wilcox 400873 N/A PC 14X N/A ment No IDCN#001 Replace HBC-141-1 Tube Turn W8117 N/A PC 15X N/A ment No IDCN#001 Babcock & Replace Wilcox OLCN N/A PC 16X N/A ment No uw_ u 1_1 NC-1 -1 bcoxk& 400873 M/A PC 4XA N/A m
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI September 23, 1987 - 1 owne, Philadelphia Electric Company o,,, Name 2301 Market St., Philadelphia, PA 19101 9 Sheet of Addreas One
- 2. Plant Limerick Generating Station un;,
Name P.O. Box A, Sanatoga Branch PECo j-Pottstown, PA ^"'"'
- reenlistion P.
. No., Job No etc. n Not Applicable-l 3 work Performed by Phieldelphia Eleetric Company Type Code Symbol Stemp Authorization No. Not Applicable N'** 2301 Market St., Philadelphia, PA 19101 Not Applicable Expiration oet. Address
- 4. Identification of System Emergency Service Water - Spec. 8031-M-511 N240, N316 1606
- 5. (al Appilcable Construction Code 19
- Edition, Addenda, Code C.=
' (b) Applicable Edition of Section XI utilized for Repairs or Replacement: 19 80 with' addenda through winter 1981
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built O' Replacement or No) IDCN#001 Quanex Gulf Replace HBC-141-1 staten 279602 N/A PC 17X N/A ment No IDCN#001 Bonney Replace HBc-141-1 Forge CB92 N/A PC 18X N/A ment No Replace HBC -141-H18 PECo ** N/A N/A A-36 N/A ment No Replace HBC-141-H19 PECo ** N/A N/A SA-515 N/A ment No Repalce HBC-141-H2O PECo ** N/A N/A A-36 N/A ment No Replace HBC-141-H21 PECo ** N/A N/A A-36 N/A ment No SP-HBC-141-Replace El-H15 PECo ** N/A N/A A-36 N/A ment No SP-HBC-141-Replace El-H16 PECo ** N/A N/A A-36 N/A ment No IDCN#001 Replace HBC-141-3 Ladish DZ6S N/A PC 18X N/A ment No IDCN#001 Replace HBC-141-3 Ladish DX6B N/A PC 5X N/A ment No IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400873 N/A PC 4X N/A ment No IDCN#001 Replace L* HBC-141-3 Ladish DX6B N/A PC 3X N/A ment No
1 i l ~ FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ~ September 23, 1987
- 1. owne, Philadelphia Electric Company oeie Nome 4
9 2301 Market St., Philadelphia, PA 19101
- snee, Address
- 2. Plant Limerick Ceneratinst Station unit One Name PECo P.O. Box A, Sanatoga Branch
"*** O'eenimlon P.O. No., Job No.. etc. Pottstown, PA Not Applicable
- 3. Work Performed by Philadelphia Electric Company Type code symbol Stamp Not Applicable Authorization No.
2301 Market St.. Philadelphia, PA 19101 Empiration oste Not Applicable Addreas Emergency Service Water - Spec. 8031-M-511. N240, N316
- 4. Identification of System 1606
- s. (a) Applicable construction code 19 Edition.
- Addende, Code ca 80 with addenda through winter 1981 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Senal No.
No. Identification Built o' Replacement or No) e IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400874 N/A PC 2X N/A ment No IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400873 N/A PC 6X N/A ment No I IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400873 N/A PC 6XA N/A ment No l IDCN#001 Replace HBC-141-3 Ladish DX6B N/A PC 7X N/A ment No l IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400873 N/A PC 8X N/A ment No .IDCN#001 Replace HBC-141-3 Ladish DX6B N/A PC 9X N/A ment No i IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400874 N/A PC 10X N/A ment No IDCN#001 Replace HBC-141-3 Ladish DX6B S/A PC 11X N/A ment No 1DCN#001 Babcock & Replace HBC-141-3 Wilcox 400874 N/A PC 12X U/A ment No 1 IDCN#001 Anchor /Darli n Valve Replace f-A121-1-3 N/A 1025C 87 ment Yes HBC-141-3 Valve Co. IDCN#001 Babcock & Replace HBC-141-3 Wilcox 400873 N/A PC 14X N/A ment No IDCN#001 Replace HBC-141-3 Tube Turn W8117 N/A PC 15X N/A ment No I i I i
l u l l, FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1,owne, Philadelphia Electric Company
- oei, September 23, 1987 Name 2301 Market St., Philadelphia, PA 19101 5
9 sn, Adoroes 2 Plant Limerick Generating Station Unit One Name P.O. Box A, Sanatoga Branch PECo ^ " * ' * " "***"0*"*"^0'**""""'"' Pottstown, PA
- 3. Work Performed by Philadelphia Electric Company Type Code Symbol Stamp Not Applicable Authorization No.
Not Applicable Name 2301 Market St., Philadelphia, PA 19101 Expiration Dete Not Applicable Address
- 4. identification ot System __ Emergency Service Water - Spec. 8031-M-511, N240, N316 1606 coo, c,
5, (a) Applicable Construction Code 19 Edition.
- Addenda, (b) Applicable Edition of Section XI UtMized for Repairs or Replacements 19 80 with addenda through winter 1981 6, Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stemped Name of Name of Manufacturer Board Other Year
- Repieced, (Yes Component Manufacturer Serial No.
No, Identification Built or Replacement or No) IDCN#001 Babcock & Replace l HBC-141-3 Wilcox 9tCRC N/A PC 16X N/A ment No j IDCN#001 Quantex/ Gulf Replace l HBC-141-3 States 279602 N/A PC 17X N/A ment No ) Replace 1 HBC-141-H8 PEco ** N/A N/A SA-515 N/A ment No Replace HBC-141-H9 PECo ** N/A N/A A-36 N/A ment No Replace HBC-141-H10 PECo ** N/A N/A A-36 N/A ment No IDCN#001 A-500 Replace SP-HBC-141-E3-H16 PECo N/A N/A A-36 N/A ment No IDCN#001 Replace SP-HBC-141-E3-H17 PECo** N/A N/A A-36 N/A ment No i IDCN#001 Bonney Replace HBC-150-1 Forge W858 N/A PC 1X N/A ment No IDCN#001 Babcock & Replace l l HBC-150-1 Wilcox 400874 N/A PC 2X N/A ment No l IDCN#001 Replace I i HBC-150-1 Ladish l DX6B N/A PC 3X N/A ment No IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 4X N/A ment No IDCN#001 l Replace HBC-150-1 Ladish DX6B l N/A PC SX N/A ment No i l 1 l ____________-___-_____a
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company onte September 23, 1987 1, owne, name 6 9 2301 Market St., Philadelphia, PA 19101
- snes, Address
' Limerick Generating Station
- uni, One I
- 2. Plant Nome PECo P.O. Box A, Sanatoga Branch
*"*""^~"*"#"*"*"*- Pottstown, PA
- 3. Work Performed by Philadelphia Eleetric Company Type Code Symbol stamp Not Applicable Authorization No. Not Applicable Nama 2301 Market St., Philadelphia, PA 19101 Empiretion oete Not Applicable Address Emergency Service Water - Spec. 8031-M-511, N240, N316 O, identification of System 1606 Code Case
- 5. (e) Applicable Construction Code 19
- Edition, Addende.
(b) Applicable Edition of Section XI Utilfred for Repairs or Replacements 19 80 with addenda through winter 1981 ' 6. Identification of Components Repaired or Repieced and Repfscement Components l ASME Code Natione
- Repaired, Stamped Name of Name of Manufacte err Board Other Yeer
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) IDCN#001 Babcock & Replace ( HBC-150-1 Wilcox 400873 N/A PC 5XA N/A ment No )Wilcox Babcock & Replace IDCN#001 400873 N/A PC 6X N/A ment No HBC-150-1 IDCN#001 Replace HBC-150-1 Ladish DX6B N/A PC 7X N/A ment No IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 8X N/A ment No IDCN#001 Replace HBC-150-1 Ladish DX6B N/A PC QX N/A ment No IDCN#001 Babcock 6 Renlace HBC-150-1 Wilcox 400873 N/A PC 10X N/A meht No IDCN#001 Replace HBC-150-1 Ladish DX6B N/A PC 11X N/A ment No IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 12X N/A ment No IDCN#001 Anchor Valve Replace HBC-150-1 Darling 1E-A121-1-9 N/A 11-1027A '87 ment Yes IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 14X N/A ment No IDCN#001 Replace i l HBC-150-1 Tube Turn W8117 N/A PC 15X N/A ment No IDCN#001 Babcock & . Replace HBC-150-1 Wilcox 9LCRE N/A PC 16X N/A ment No I I i l
l 1 l 4 ~ FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company o,,e September 23, 1987 3, gn, Nome 2301 Market St., Philadelphia, PA 1.9101 sheet 7 of 9 Addrome
- 2. Plant Limerick Generating Station unit One Name P.O. Box A. Sanatoga Branch PECo Pottstown, PA
- 3. Work Performed by Philadelphia Electric Company Type Code symbol stamp Not Applicable Authorization No. Not Applicable Name 2301 Market St., Philadelphia, PA 19101 Expiration oste Not Applicable Address
- 4. identification of system Emergency Service Water - Spec. 8031-M-511, N240, N316 1606 Code Case
- 5. (a) Applicable Construction Code 19
- EdWon, Addenda, (D) Applicable Edition of section XI Utilized for Repairs or Replacements 19 80 with addenda through winter 1981
- 6, Identification of Components Repaired or Replaced and Replacement Components ASME Code j National
- Repaired, Stemped Name of Name of Manufacturer Board Other
- Yes, Replaced, (Yes Component Manufacturer Serial No.
No. Identifiestion Built or Replacement or No) IDCN#001 ' Babcock & Replace HBC-150-1 Wil:.ox 400873 N/A PC 17X N/A ment No IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 18X N/A ment No IDCN#001 Replace HBC-150-1 Ladish DX6B N/A PC 19X N/A ment No IDCN#001 Babcock & Replace HBC-150-1 Wilcox 400873 N/A PC 20X N/A ment No IDCN#001 Replace BBC-150-1 Tube Turn W8928 N/A PC 21X N/A ment No Replace HBC-150-H17 PECo ** N/A N/A A-36 N/A ment No Replace HBC-150-H18 PECo ** N/A N/A SA-515 N/A ment No Replace HBC-150-H19 PECo ** N/A N/A A-36 N/A ment No IDCN#001 Replace HBC-150-3 Ladish DZ6S N/A PC IX N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400874 N/A PC 2X N/A ment No IDCN#001 Replace HBC-150-3 Ladish DX6B N/A PC 3X N/A yn IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 3AX N/A ment No I i i I
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company o,,,. Se tember 23, 1987 ,, g n,, N.me 2301 Market St., Philadelphia, PA 19101 Sheet 8 of 9 Addreas
- 2. Plant Limerick Generating Station Unit One I
Name P.0, Box A. Sanatoga Branch PECo Poetstown, PA Ad 8'*"
- ***" 0*nlastion P,0. No., JoD No., etc.
- 3. Work Performed by Philadelphia Electric Company Type Code symbol Stamp Not Applicable Authorization No, Not Applicable Nome 2301 Market St., Philadelphia, PA 19101 E,pir, tion o.te Not Applicable Address 4 identification of system Emergency Service Water - Spec. 8031-M-511. N240. N316
- 5. (a) Applicable Construction Code 19
- Edition, Addenda, 1606 Code Can (0) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 with addenda through winter 1 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Yeer
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification ' Built or Replacement or No) IDCN#001 Replace HBC-150-3 Ladish DX6B N/A PC 4AX N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 4X N/A ment No IDCN#001 Replace HBC-150-3 Ladish DX6B N/A PC 5X N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 5XA N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 6X N/A ment No IDCNF001 Replace HBC-150-3 Ladish DX6B N/A PC 7X N/A ment No IDCN#001 Replace HBC-150-3 Ladish DX6B N/A PC 8X N/A ment No IDCN#001 Babcock Replace HBC-150-3 Wilcox 400873 N/A PC 9X N/A ment No IDCN#001 Replace HBC-150-3 indinh DX6B N/A PC 10X N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 11X N/A ment No IDCN#001 Replace HBC-150-3 Ladish DX6B N/A PC 12X N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 13X N/A ment No I
4 FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 3, %n., Philadelphia Electric Company osie September 23. 1987 Name 2301 Market St., Philadelphia, PA 19101 9 9 3n,,, Address
- 3. Plant Limerick Generating Station Unit One Name P.O. Box A, Sanatoga Branch PECo Addren Repair Organisetton P.O. No., Job No., etc.
p
- 3. Work Performed by Philadelphia Electric Company Type Code symbol Stamp Not Applicable Authorization No.
Not Applicable N'** 2301 Market St., Philadelphia, PA 19101 Empiration Dete Not Applicable Ad dress
- 4. Identification of system Emergency Service Water - Spec. 8031-M-511, N240, N316
- 5. (a) Applicable Construction Code 19
- Edition, Addenda.
1606 Coce Can (b) Applicable Edition of Section XI Utilized for Repeirs or Replacements 19 80 with addenda through winter 1981
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stemped Name of Name of Manufacturer Board Other
- Yea, Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement Sr No) IDCNv001 Anchor-Replace E-Al21-1 ' o N/A ll-1027C 87 ment Yes HBC-150-3 3arling/Valv IDCN#001 Babcock & Replace HBC-150-3 Wilcox 400873 N/A PC 15X N/A ment No IDCN#001 Replace HBC-150-3 Tube Turn W8117 N/A PC 16X N/A ment No IDCN#001 Babcock & Replace HBC-150-3 Wilcox OLCN N/A PC 18X N/A ment No IDCN#001 Replace HBC-150-H9 PECo ** N/A N/A SA-515 N/A ment No IDCN#001 Replace HBC-150-H10 PECo ** N/A N/A A-36 N/A ment No IDCNf/001 - A-500 Replace HBC-150-Hil PECo ** N/A N/A A-36 N/A ment No IDCN#001 A-500 Replace HBC-150-H12 PECo ** N/A N/A A-36 N/A ment No l 1 1 a
geeegsm n wpsezern2TwasArekM M M2??&mKMV
- gy FORM Nis 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Co.
September 23, 1987 ,, g, Nome 2301 Market St., Philadelphia, PA 19101 1 Address Limerick Generating Station' One ,,p,,,, unit P.O. Box A _Sanatoaa Branch. Pottstowi. PA 19464 PECo Ad or mopeir oreenisetion P.o, No., Jet No. etc.
- 3. Work Performed by_ Philadelphia Ele _c1ric Co. __
Type code Symool stamp N/A Authorisetton No. N/A 2301 Market Street. Philadelphia PA 19101 Empiretion 0.ie N/A Avere
- 4. identification of system Eu rgency service W eer Reecification 8031-M-511 N240, N316 1606 6, (el Applicable Construction Code _
19 _ Edition:
- Addende, c.,, e,,,
(b) Applicable Edition of Section XI Utillred for Repeles of Replacements 19 80 with Addenda through Winter 1981
- See Specification 8031-P-360, Rev. 11.
6, Identification of Components Repolted or Repieced and Replacement Components ASME i-Code Nettonal
- Repolted, Stemped Nome of Name of Manufacturer Board Other Year fleptoced, (Yes Component Manufacturer Serial No, No, loontification Built or Replacement or No)
I^CN 001 Against Quanex Golf Ht. No. SP-UBC-140-El States 279602 N/A PC 2X N/A 'Replacetten': No JDCN001nf*bE*140-v1 Henry vogt valve l Machine Co, 2415401 N/A 11-1019 '87 Replacemen: Yes l Op1 Quanex Et. No. E8-140-El cuir staten 770602 N/A PC 4Y N/A' ReDlacemen ; No Pjyn@@l Valve Henry Vogt ! ch-unr-loo-ri en_10215401 N/A 11-1021 '87 Replacemen';Yes w rkho 1 7, Desertation ot wo,n Replaced isolation valves in supply and return lines to RCIC pump compartment unit Cooler.
- 8. Tests Conducted: Hydrostatic. @ Pneumatic C Nomins10peret;eg Pressure O l
Other O Pre'euro 165 psi To,Te mp._ 97 er l NDTE! Supplemental sheets in form of lists, sketches, or drawings rney be used, provloed Ol site is 8% in, a 11 in., (2) Infortne. tum in items 1 throv# 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 0 2/82) This Form (E000301 may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 I
l SE92fFih15ME5NSME br ~ FORM NIS 2 (Back) l
- 9. Remarks _ Replacements were performed in accordance with ASME Section XI j
spoucer,ie uen v.ctueer e oote aeports to os ette$nea MDCP 5328, Revision 0: Specification 8031-G-33, Revision _3. NPV-1 Reports are attached for the following valves PTr1031r and valve 11-1021. 1 11-1019p,y,g j CERTIFICATE OF COMPl. LANCE We certify that the statements made in the report e,e correct and thiereplacerient_ coniorms to tne rules of the reced or footuament A$ME Code,Section XI, Type Coos Symbol Sterno N/A N/A N/A s ep;retion pai, _ Cert)4:e e of Authorize n 'o, 4 Liraerick Section M i Mechanical._Arancb cate d OB_ 19 W s;sne own., or owne,. oo.ienee, vme Head CE RTIFICATE OF INSERVICE INSPECTION 1, the 6ndersioned, holding a valid commission issued by the National Board of Boner and Pressure vessel inspectors and the State or Province ot E00USVIV8 DIS and omployed by.Nart f ord Steam Enfler inntSection of insurance Co. Hartford. Connecticut have inspected The components oescribed in this Owner's Report during the period 6h /87 M 7/N . and state that to __ / / / I to the best of my knowledge and beiief, the Owner has performed eneminetions and taken corrective measures described in this Owner's Report in accordance with the reovirements of the ASME Code, Section XI. Dy signing this certihcote neither the inspector not his employer makes any warranty, expressed or ireplied, concerning the examinations and corrective measures describec m this Owner's Report. Furthermore, neither the inspector ner his employer sheH be lieb:e in any menner for any personal Infu y or property damage or a loss of any kind arising from or connecten with this q r I Jnspection. N > 3-Commissions - NW I M ~e,,onet.oe o. msef,ome. eno. noo,se,ents ,n<j,o,a,eeg // / f in M._. oeie 02/B2) I l l l L________
Peg 2 1 of 2 % 28 FCZM NPV.1 N CERT 1FICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES
- As Required by th] Pr visirns if ths ASME Crds, Secti:n 111, Div.1
- 1. M:nufactured by Henry Vogt Machine Co.. Louisville. KY (Name and Aodress of N Certificate Holder)
~2. Manufactured for Bechtel Cons truction. In c.. P o t t s t own. PA ~ ~ (Neme end Aoore.. of Purenes. = owner:
- 3. Location of installation i 4 -o ri rte ronore.fr3 m e4nn p n r o mn, pa (Neme and Acareisi
- 4. Pump or Valve Cate Valve kninal inlet Size 2"
Outlet Size 2" (inch) Onch) (a) Model Ne,.. (b) N Certificate Holder's (c) Canadian Series No. Serial Registration (d) Drawing (f) Nat'l. (g) Year or Typo No. No. No. (e) Class Bd. No. Built E-48494. R3 1 1987 p) Cate 1-215401 (2) thru (3) 12-215401 g) (See attached (5) sheet) (6) (7) (8) (9) (10) 1 5. tenef seecnpoon of service for wnich ecuepment wee ces gneo)
- 6. Design Conditions psi
'F or Valve Pressure Class 600 0) (Temperature) (Preu vrel 1LLO psi at 100"F. , 7. Cold Working Pressure
- 8. Pressure Retaining Pieces Mark No.
Matenal Spec. No. Manufacturer Remarks (:) Castings ...\\. .2 E. i ) F3 I g (bl Forgings Body h R4678A SA105 Vone H CC
- Bonnet
- p
., g ry ry R4667F SA105 vogt m r pua t ex-l g. p_19311 1 c0015 n ) ror m.nu.Ily.,a,ed v., on,,.
- Supplemental sheets in form of lists, sketches or drawings may be used.provided (1) size is 81/2" x 11*. (2)information in
' item) 1,2 and 5 on this Data Report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at 100 of this form. ___--_____-__--___-w
l l s* ' t, FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Company pote September 28, 1984 Name 2301 Market Street. Philadelphia.Pa.19101 Sheet 1
of 1 Address
- 2. Plant Limerick Generatine Station Unit I
Name P.O. Box A.Sanatona Branch.Pottstown.Pa. Bechtel job #8031 19464 "* O'genisation P.O. No., Joe No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type code Symbol Stamp Not Aeolicable Narne Authorization No. Not Aeolicable 50 Beale Street. San Francisco. Ca. Expiration Date Not Aeolicable Address
- 4. Identification of System Feedunter System 45A N-226 N-252
- 5. (a) Applicable Construction Code 19 *
- Edition, Addenda, N-316.1606 Code Case l
(b) Applicable Edition of Section XI Utilized for Repairs or Replacement 10 RO IJinter 81 N-241 N-308
- See Spec. 8031-P360, Rev, 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year Repla:ed, (Yes Compotient Manufacturer Serial No.
No. Identification Built or Replacement or No) Piping System Guyon Ht.#NN-11 FSK-DBB-103 nRB-103 A11ove (DBB-103-N/A FW60 N/A Repair No 1-7) Sht. 3 of 3 Piping System Ht.#NN-11 FSK-DBB-103 nRR-103 U.S. Steel (DRB-103-N/A FW60 N/A Repair No 1-8) Sht. 3 of 3
- 7. Description of Work Renair veld area of nice that violates minimum wall thickness per FSK-DBB-103-1 Sheet 3 of 3
- 8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O psi Test Temp.
- F Other] Pressure
- Pressure test not required per IWA 4400(b)(3)
NOTE: Supplemental sheets in form of lists, skese,ies, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa. tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this fann. (.. 1 (12/?2) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 j 4
t 3 i FORM NIS-2 (Back) Repair was performed and completed per ASME Section XI repair plan , S Romerks Aopticeble Manufacturer's Data Reports to be attached '8031-FM-27 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thl; Reoair conforms to the rules of the '***i'***'*****"' ASME Code, Section XI. Noe Aeolicable . Type Code Symbol Stamp Certificate of Aut estion No. Not Ann 14enh1e Expiration Date Not Annlicable 7 Signed Construction Date 8 .C.T. Proient 1
- owner or owner's Desiones, Title
/ CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State The Martford Steam Boiler EnsDection & og or Province of E nn" <:Vlvania and employed by have inspected thUMhnNt O Abed hwe #w A e- / /W d /O / II" and state that ~ to in this Owner's Report during the pe od to the best of my knowlooge and belief, the Owner has performed examinations and teken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report, Furthermore, neither the insoector nor his employer shall be liable in any menner for any personal injury or prope'1y damage or a loss of any kind arising frum or connected with this inspection. M S Yd M11 / Commissions ( ~s.,ene.oe,o....to. ,0.,n. ano.no o,s .n,s ,nsopruin.,g I 19 Y6 Dete. (12/82) g .w - _. _ _. -a
9 1 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEIVIENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Comoany Date November 15, 1985 Name 2301 Market St. Philadelphia,PA. 19101 Sheet I
of I Address
- 2. Plant 1.imerick Generating. Station Unit I
Name P.O. Box A.Sanatoca Branch.Pottstown.PA. Rocheol inh RO11 Repelr rganisati n P. . No., Joo No., etc. Accr*" 19464
- 3. Work Performed by Bechtel Construction. Inc.
Typo code SymboiStamp Not Aeolicable N'** Authorization No. Not Aoplicable 50 Beale Street, San Francisco. CA.94105 Expiration oate Not Annlicable Ad cross
- 4. Identifiestion of System Diesel Generators and Auxiliaries
- 5. (a) Applicatie Construction Code 19
- Edition, Addenda N-308.N-240 Code Case (b) Applicable Editica of Section XI Utilized for Repairs or Replacements 19 80 Winter 81 N-316,1606
- See Spec. P360 Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components
}3 ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) Bechtel SP-HBC-1AS-Replace-HBC-352 Construction N/A N/A 575 1985 ment No lBechtel SP-HBC-1BS-Replace-HBC-352 Construction N/A N/A 575 1985 ment No Bechtel SP-HBC-1CS-Replace-HBC-352 Construction N/A N/A 575 1985 ment No Bechtel SP-HBC-IDS-Replace-HBC-352 Construction N/A N/A 575 1985 ment No
- 7. Description of workModify diesel nenerators exhaust silencer drain piping per BMMP-M-2, plan #85-2
- 8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure
- 0ther G Pressure pel Test Temp.
72 'F
- Hydrostatic Head NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. m 11 in., (2) informa-I tion in items 1 througti 6 on this report is included on each sheet, and (3) each sheet is numbered and the numbr,r of sheets is
] recorded et the top of this form. \\ (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 )
e 's FORM NIS 2 (Back)
- 9. Remarks Modify exhaust silencer drain piping per BMMP-M-2 plan #85-2.
This AppHesble Manufacturer's Date Reports to be etteched replacement is ASME Section III Class 3 and ASME Section XI unclassified. CERTIFICATE OF COMPLIANCE W9 certify that the statements made in the report are correct and thiaR e pl n e me" P conforms to the rules of the D * " D' D '6""5 ASME Code, Section Xl. Not Applicable Type Code Symbol Stomp Not Applicable gxpir, tion p.1, Certificate of Authorization No, !!~ Ib M A4DM Date 19 Signeo Owrier or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board Lf Boiler and Pressure Vessel inspector 9 and the State The Hartford Steam Boiler of or Province of Pennsylvania and amployed by Insoection & Insurance Co., Hartford, Conn. ave inspe ed the components described "I J f ' #' U ! ** ~ ' O /N to and state that in this Owner's Report during the period to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repcrt in accordance with the requirements of the ASME Code, Section XI, By signing this certificate neither the Inspector nor his employer makes any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damege or a loss of any kind arising from or connected with this inspection. N WM Commissions / inspector's Signature National Board, State, Province, and Endorsements Date MW"- 19 (12/82) ) W~
f FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by.the Provisions of the ASME Code Section XI
- 1. Owner ph41ncle1nhin F19<evic ('omn nny Date September 28. 1984 Name
?"An 1 Ma rle e t Arrepr.Ph41ndelehin.Pa.19101 Sheet I of 2 Address J
- 2. Plant T 4mor4 cte ronerneine Arnr4nn Unit T
Name' P.O. Box A.Sanatoga Branch.Pottstown.Pa. Bechtel Job #8031 Addrm 19464 Rooalt Orgeruastion P.O. No., JoD No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol Stamp Not Applicable Authorization No. Not Applicable 50 Beale Street. San Francisco. Ca. Expiration oete Not Applicable Address
- 4. Identification of System Feedwater Svstem 45A N-252 N-226 Addenda.N-316.1606 Code case 19
- Edition,
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Winter 81 N-241 N-308
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Reptaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement or Nol Piping System Texas Pipe N302-M8-5 s DEA-112 Bendine Co. (DBA-112-N/A DBA-112 1980 Repair Yes 2-5D) FW58 i I Piping System Texas Pipe N302-M8-4 DEA-112 Bendine Co. (DBA-112-N/A DBA-112 1980 Repair Yes 2-5B) FW58
- 7. Description ot Work Reoair veld area of pipe that violates minimum wall thickness per DBA-ll2-2
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure O Other O Pressure N/A psi Test Temp. N/A
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in. x 11 in (2) Informs. tion in items 1 through 6 on this report is included on each sheet, and (3) sech sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 ] i ~e. es i
a j / \\ l FORM NIS-2 (Back)
- 9. Remarks Ret, air was t)erformed and cornlered ner ARMF Rorrinn YT renn4Y n1nn Aoplicable Manufacturer's Date Reports to be etteched RO91-TM-16 i
l l CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are Correct and this E Pp A 4 Y confgrms to the rules of the P*i'"'D'*****"* ASME Code, Section XI. Not Applicable Type Code Symbol Stamp Not Applicable Expiration Date Not Aeolicable Certificate of Autho 't ion No., I Signed k ,C.I. Proiect Cons truction Date b M 19 owner or owner s Designee Titie g, / CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State The Hartford Steam Boiler Insoection & of or Province of Pennsv1vania and empioved by Martford. Conn. have inspected the [rkpNnks deshrfbed bd'N Y~ O /* _ and state that to in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal irdury or property damage or a loss of any kind arising from or connected with this inspection. N, Commissions W6 4 W (/ Inspect A Signature National Board, State, Province, and Endorsements Date /A3 19 (92/82) ,_/
j I k i 1 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPL CEMENTS As Recuired by the Provisions of the ASME Code Section XI
- 1. Owner Philadelnhin Electrie- ('n mn n ny Date sentember 28. 1984 Name 7101 Mnrieer Revent. Phfindelnhin.Pa.19101 Sheet 7 of 7 Address
- 3. Plant Limerick Generatine '3tation Unit I
Name P.O. Box A.Sanatoga Branch,Pottstown,Pa. Bechtel Job #8031 Ad o'*" 19464 Repelr Creentmlon P.O. No Woo No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Ty'pe Code Symbol Stamp Not Applicable Nerne Authorization No. Not Applicable-50 Beale Street. San Francisco. Ca. Expiration Date Not Applicable Address G. Identification of System Feedta nt e r Svstem 45A N-252 N-226
- 5. (a) Applicable Construction Code 19__*_ Edition.
Addenda.N-316.1606 Code Case (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 1980 Winter 81 N-241 N-308
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components l
l ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) l Piping System Texas Pipe N302-M8-5 DBA-112 Bendine Co. (DBA-112-N/A DBA-112 1980 Repair Yes 2-5E). FW66 Piping System Jones & Ht.#26090 DBA-112 Lauchlin (DBA-112-N/A DBA-112 N/A Repair No 2-11) FW66
- 7. Description of work Renair weld area of oice that violates minimum wall thickness per DBA-112-2
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure C Other Pressure N/A psl Test Temp.
N/A
- p NOTE: Supplemental shewts in form of lists, sketches, or drawings rnay be used, provided (1) size is 8% in. x 11 in., (2) informe.
tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. s (12/82) This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 -o. o
s., / I FORM NIS 2 (Back) i
- 9. Remarks Renai r tenn nerfnmod nna enmnl arna par _ASE.yn, r4 nn yr vonniv n1nn Applicable Manufacturer't Cata Reports to De attached 8031 -ni- %
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Wppn4" conforms to the rules of the '*D**'"*"* ASME Code, Section XI. Type Code Symbol Stamp Mnr Ann 14enh1c Certificate of Auth ation No, Not Aeolicable Expiration Date Not Applicable Signed C.I. Proiect Construction Date M O2 g, f 19 Owner oT Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State I The Hartford Steam Boiler Inspection 6 of or Province of Pennsylvania and employed by Hartford. Conn. how inspected th M E fs b bfibed Y~S~
- 2 /' W
. and state that in this Owner's Report during the period to , to the best of my knowleoge and belief, the Owner has performed examinations and taken corrective measures described in this owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, netther the inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. y' ' Commissions - Ib 847 s in 's Signature National Board, State, Province, and E ndorsernents bA 19 EI Date / (12/82) J _____________________._J
gs.- >.,,. w. t.'.v.dyp&s,c..,,e.,.c,.w.e.m.wm m$5-:$ihb?.: n; +.... e .~. W7q~q...
- m... r.
- .-
..w...-. %,e.>... ..t.: ; w.m.v.m..m a
- 9 n s..
v.. p tc. 4....,
- p..:m. w..e. y eye.. u.
..~ . n. .4.w..... m. i v 1 ar.,a R.x.. y.e.r. . s. y Y.Wy-q.y$5 .m .m-f a. w.. v.~. e.u r s .e e e iW.aW + U L w.WS6l W:... ,..m$ $ptu M.jh&lv.hM 'W W'E-Qk.,.m.;W h-n[h.Y ~le:;5..x? M T.B W*hm. i%&Ar. wm.w m 4::." ~ % - ? % O *.: i .x "h.'. %w ^ 85 n, D;Q. n ws.Mm'. ~ 4:h.v. Wi.h.M;d.MYi.L ;.' di.e.%; ~%c~~&llMWi-M., %:j.;.g@.W.8? ~ i i-:M WAGW V @ y, 's.d -: b
- a. ;.
- T. Q9. q:q ~3 :n: & ^ T & W
- 9.?
.?W 12 W ~~ W ' .,i '. g;... ... 3., .:rg. . 3N. u. $, ;.,,. : ..? rhE .,~,; a.. 7. M.M..,, _..%,.,.,@,., fG.,s.t.,...S.,h.,.@t,,, w.b'.>,.. .a c.Wy;x&v. .,....... a. ., :c. c.- -rr~s. 'e%g. _,.ltk } lFM::, i:.:::. wur.':; 7,E.n.:r.7.f,y =.r. m..,. a n.;JEP.,LACEia..d.?'.. G 'G . ~& &..n. ~r.f .;....Z r.7. t W y @,, 4..:r'. ..,.*r
- e. ~.
.-.m .~,.. e: - ~ . ~ .L ~. ~- .%~. a;q. . y A.: 3em! n. f..hy.rS,.Pr W.:.t_.1 m. ......... s. 2.e.',:tios X. I :..,.. ". e-m 4 ..-1 .~..:."a... 3;,;,3 4.". T manana.....m.ucame s a- ~ _. mma-a c. swan. w Ses ar. a.6s ies.rw-- w.~u m e -N. pf' g4+y,Np$-US;ccwvcq,EleitriC ( wcNy.y,pqyy,g,,i/ ~ enMg r-3;r$gfp...w.p. u...m..c. m,$.... ~ -4G' Qi . --.c ~ Phila^de1 chia : JComcan . M 3/28/85 M A %hs@W2301 Mai !Id 'S t Fe e t MTTIa'i!!'i e h i MPGl'9101 T. Wr's1WW,Mealm.sd j
- h..,rg.Dh$WtM OMik ' Gide EritY5 tYiToY.M6,i.FUnftM YN3. 1.?%M M M W'WA. - ~.7 i
9 m.p&yts#%g~3Ev.ergreen i,&.SanattTa ;Rds.'7iR;0.iBo6A,%Sanato,gaDPA.+w.1 '-9 64 w s @.. k, g w-nyggAfi.JWirk Perferr.ud by "-p.p' '" m0 p-...p-. - m. w, m
- Wy.q,p= ew. 2=Wh. w.?L.u...,..
m .;.. w mm.m <...u p.
- e..
w nt 4-M13. @ p $s %~ v., W.:g=e y::m-- g 9. w - ~* =",.~*, s y2-m --. c. n s a.m= aa e.o no..ma ac.,w.m.,, .r "- X..pr.4 w.,-v.n.,+., u.,:- Reaetor< Pre.. _a s su re - Ve s s el ee"*n sg gwe,o.,;p..~,,,,;v...A.; n -.g t~t: c; 4 g y-m- ,,5; u. n a W :n.*: 4. le u..~ ,_.n b.e.&q&;,T. M. b)entinestich of systemd. 5 9::.!de ' w w m = 2-.v = m ~,. ".,. l 5 Applicsble Constru'etion Code Se C. I I I 1g 68 -**'-" Edition 2 5 ' 6 9 ~~."Ade'ende, code Cases
- 4-U : -
~ (b)
- Applicable Editio'.r.I.of.Sedfo'n XI IMked for R.
N-308 M,.../f 9 o .c. WegiM.W.W:*.M*:"Vpv Pl.e.'. #.F.W_..;.7 " - obi
- 6...
, and Repiecement Component &gp Name of ~*(1 7.f., h ComporienC Y Name of J Mfts. Ser. - INet'I.',) .iCRN 3 -) Other 3 ear Is[ t'A Repairsd,,M .N ACME Code ~ p terl:id P ~- g t SNo,'W,fdst$. U* *' .'; Mfr. Y M No.'W 5 8d. '$ D YRe blFI[c.rkh - L.y.g.w - g#;. Hdtion m,mfa %,c;plac.ed, F 13uilt r~.. Stamped w (Ya or No)L' .e s V y,;j$g:hh..% & ?y.,3 ~t.~: gL. 2:W .w - . ~.- .vve y.8. g d rm t a gNog w.p r-v7-or,. 4.s uEM.k Wed$$Gk
- Reptocement A5' 3 ;..
..1 sT*H WE ,y N_ k.tNM iMR*.f6.:d, ....i. ' C,l.,o,sare15tu'd 3TimkinV 425 M #1NA W GW $$Mb EW Re31FCeinent' T NO WWD. C. p .m._ n l..i. sYr'e~~ sunTimidE4 425 h% fN 7% MM Mi@Ti2 ##@ Reold'Ee' snt' C ';O7NO. M ' M k...$ - E m N 0 % :i M 8..... I Cl os'dsla sh'e'r TimidU O 25 6 TNAT 4W@ MM M': Re'dlaTeMeiit N M t'5DW$le! WMrt P. W.i'WA AN,m MM MMV %M W-5:n.wd.7 .7 ::.- m::2. M F. u. w: e.R..%... w w< w.y Etd' t;:sz M.M. .;Lus7A :c;k o u, m.em. s;. O,,E., ;. ff(yj,y.,. Med6 31.+1AI 4 s .4@W4 HM%k MMG Ye@it- #nW MtRt EiW4 M:W3;!c WWdh.QEdj'[ ! y$G7.S cescrip'tTo'rfcN Erk .me.g.w~'a'ttaChed evaluation recortw:-m.o.pe4W....,m* W:'. ,. m '. .- -- w - >e w. N See e"-
- " p,:p.
l
- f
- a. ?. Tests conduc O{g@/b@%cggg*ted: Q/ Hydrostatic O $ Pneumetic O f Nominal Operating Pressure O 2ff Othe rwt<.-%.a. AM,..-
l pipd,..p. g Rer arks. Stud @. nut. - a nd a s her st Temp md Pressur= " ps!T Te 'FMLdd'%Cifit'.k+*e:Ndd $DEESM.k 47.5 removed 5from' Unit >two RPV and - o jF. g. .x o > M.ce l o c.. mucao.e a t i n n Uanuisciu<erdn.,;a,
- kan
- .. ytta c h,edpl u,,..~..,,...
o w.,. e s a.... A of t nne PV M ea a eva atinn. ra nn rt e r.d e ta il e..,,,," pyy%..';f;!.% -1 x .u-w.. u..u~. % y m c. v. +,.m %,.::w. e,r+ o. ,w., ., w. -y. m. Nf,5:s.} " ::, h... !C Q.Q:... 4;,p...%.T:W.l[N.u%.+. CERTIFICATE OF COMPLIANCE g@G.Q-y 2.Ir x.yy%,,g:: C'E4-d, N % l j_.E W3 ctrtify that the statements made In this report are correct and this.; M 52 6mthra y fe.reyD 8 C"e'me nt MW.'. u. ~
- .* a 4'
-conforms to Section XI of the i XASME Code. %!--"- - ' iSQiV'. p ~Qy;?-@?,-$$t*tr*.@?P.''**'"*"O E.r. '.% *. > -.,t" g' rec &e~e:r"~.a@ Mac ms m' Sgned w a.u w a m = W ' 5! 1 ':El .;rw.u ,a,~u.,=>...:....u....e. x,. g m w n,..,T. m e n g. m p c. y~n.. .-..::. M r2.tts:CER IFICATE'0F INSPECTION ww'y~=;q.. n n: v: q-
- w
-r- =..w-.~. .y. ~ - ~ f, ths underalgned holding a valid commission Issued by the Nations 8 of Boller and Pressure Vessed inspect rs and the State 1wucudi er Provirbe.,o ~ 'D, em yed by & 2 chb 5 bnwend 4 f f /bLr A. %e e in,,ec,ed,he uAG# Mesc,ihean gis ne,o,, cn #M e ,1, g j (@epaar(s} or 8epsacernent sil .E. / cnd st2te tnat to the best of my knowledge end belief, this repair or replacement has been constructed in accordance with Section XI of the ASME Code By signing this cert!ficate, neither the Inspector nor his employer makes any warranty, expressed or Impfied. concern-ing tha repair or replacement described in this Report. Furthermore, neither the inspector nor his employer shall be liable in isny menner for any personal injury or property damage or loss of a. y kin rising from or connected with this inspection. Dats b 5 / d-Commissions / pnspecton (State or Province, National BoanS Nets: Supplemental sheets in form of lists. sketches, or drawings may t>e used provided (1) size is 8% in. X t1 in., (2) Information in Items 1 through 4 on this date report is included on each sheet. and (3) each sheet is numt>ered End tn' e number of sheets'Is recorde7at the too of this form. 634 - ~ ;y y -..3 .~ : 9 ig b
i g' J j i -o i FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Company o,t, February 7, 1985 l
Name 2301 Market Street. Philadelphia,Pa.19101 Sheet I of 1. Accrees i
- 2. Plant T fmerick Generatine Station Unit I
Name P.O. Box A.Sanatona Branch.Pottstown.Pa. Bechtel Job #8031 Accrees 19464 Repair Organization P.o. No., Job No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol StampNo t Applicable Authorization No. Not Applicable 50 Ronle 9treet. San Francisco. Ca. Expiration Date Not Applicable I Accrees
- 4. Identification of System pantent Prpentire Vessel
- 5. (a) Applicable Construction Code Aqw TTT 19 6R Edition, Somer 69 Addenda. N-308 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 74 Summer 75 l
- 0. Identification of Components Repaired or Replaced and Replacement Components I
ASME r Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes
] Component Manufacturer Serial No. No. Identification Built or Replacement or No) l Reactor Pres-Chicago j eviva von =al n ri rige & T31 3908 N/A 1976 Repair Yes Iron Co. i hnnger and attachine welds from Reactor Vessel
- 7. Description of Work Romnve I
B. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure j Other Pressure M/A psi Test Temp. N/A 'P NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% In. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. l l o (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l )
<e. FORM NIS.2 (Back)
- 9. Remarks Ronnir unn nerfnrmd nnd tnmnlpred ner A WF Section YT renair plan Applicable Manufacturer's D.te Reports to be attached RM1vw?
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RepA1Y conforms to the rules of the ASME Code, Section XI. Type Code Symbol Stamp he Arm 14 r nh1 a Not Applicable Certificate of Autho ization No. Not Aeolicable Expiration Date u W B.C.I. Projeet Construction Dets }
- 19
( Signed' Owrter or owner's Desiones. Title Mr. CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding e valid commission issued by the National Board of Boiler and Preuvre Vessel inspectors and the State The Hartford Steam Boiler Inspection 6,, or Province of Pe""RVIVA"iA and employed by Martford. Conn. have inspected thbkoNnY dhrlbed I N40D !U to and state that in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examirietions and taken corrective measures described in this j Owner's Report in accordance with the requirements of the ASME Code, Section XI, j By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the ] examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer i shall be lieble iri eny menner for any personal injury or property demoge or a loss of any kind arising from or connected with this ) inspection. N I Commissions I n.p.c o,.s.,,n.,ure ~s_. .os,o.. e,... o.co. eno. noo,s. en,s N 19 c. Date 02/82) i i/ '.o.. ~
a. g. 't l j. 9 .~ a 'i FORM N!S 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 's As Required by the Provisions of the ASME Code Section Xi i, owner Philadelphia Electric (bucany o[,,7/25/86 2301 Market St. N'*' 1 8 Phila., Pa. 19101 nee,, ,t Adoress Limerick Generating Station ' unit El ^
- 2. Plant Evergreen & Sandtciqa Poads g
P.O. Box A, Sanatoaa, Pa. 19464 MRF #8601821 & 8601822 Repair Organization P.O. No., JoD No., etc. Address N/A Philadelphia Electric Opry Type Code symboi Stamp
- 3. Work Performed by N/A 2301 Market '9tD'eet Authori2ation No.
N/A Philadelphia, Pa. 19101 Expiration oate Ad dress SYSTEM 41 Main Steam Relief Valve l 4 Identification of System N/A 60 Edition,Sumner 70 AbE III 19 gee,ne,_ c,g, e,,,,
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, W, 81 l
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Bo'ard Other Year
- Replaced, (Yes Component Manuf actu rer Serial No.
No, IdentJication Built or Replacement or No) PSV-041 MS Target Relief Valve Ibck 517 N/A 1F013A 1979 Replaced Y PSV-041 Replace-MS Target Relief Valve Ibck 510 N/A 1F013A 1979 ment Y FbV-VM MS Target Pelief Valve Ibck 520 N/A 1F013B 1979 Replaced Y M5 Target pSV-041 Feplace-Relief valve Pock 534 N/A 1F013B 1980 ment Y QalV OIc' EGplace Main Steam Reli
- 7. Description of Work J
B. Tests Conducted: Hydrostatic C Pneumatic 0 Nominal Operating Pressure jg'J 86 184 Other @ Pressure 990 ps; Test Temp. .g a Supplemental sheets in form of lists, sketches, or drawings rnay be used, provided (1) size is 8% in. x 11 in., (2) Informa. NOTE: tion in items 1 through 6 on this report is includ'ed on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. l This Form (E00000) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 (12/82) ~ ~' ~ ~ ~ ~ " ~ ' ~ ' * * * ^ ' ~~ ~
- "~~#
r, ) FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company glie 7/25/86 1 owner 43va. m rxet Turoes Philadelphia, Pa. 19101 2 Sheet Ac or e58 Liinerick Generatina Station unit el 8
- 2. Plant Evergreen & SanaE6ga Ibads MPF #8601859 & #8601823 p. n. pm A. Annarma. pn.
1 gaga Repair Organization P.O. No., Job No., etc. Aooress Philadelphia Electric (b. Type Code Symboi Stamp N /n
- 3. Work Performed by 2301 Market" W reet Authorization No.
M/n sbh Phil nr%1 nhi n. pn l oi m Expiration Date Aooreis SVStem 41 Ma n Steam Relief Valve 4, identification of System N/A Code Case
- 5. (a) Applicable Construction Code ME III 19.68 Edition, Stmner 70
- Addenda, 80, W, 81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) PSV-041 MS Target Relief Valve Ibck 525 N/A 1F013 C 1979 Replaced Y PSV-041 Replace-MS Target Relief Valve Pock 511 N/A 1F013 C 1979 nent Y / PSV-041 MS Target Relief Valve Pock 526 N/A 1F013 D 1979 Replaced Y PSV-041 Replace-MS Target Relief Valve Ibck 530 N/A 1F013 D 1980 ment Y j Paolace Main Steam Relief Valve
- 7. Description of Work P, Tests Conducted: Hydrostatic C Pneumatic Nominal Operating Pressure Other @ Pressure _990 psi Test Temp._
184 F /O-J.gg Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in.x 11 in., (2 i NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of she recorded at the top of this form. This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 (f2/82) +a. n
. +. g e
- r;
,...'~: r- ) 's FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ~
- 1. Own,,_ Philadelphia Electric Ccrnpany caie' 7/25/86 2301 Market Street 3
1 Philadelphia, Pa. 19101 cs,,, Ad cress
- 1 Limerick Generating Station Unit
- 2. Plan, Evergreen & Sanatoga Feads MRF #8601860 & #8601861 P.O. Box A, Sanatoga, Pa.
19464 fiepair Organiseison P.O. No., Joe two., etc. ~ Ac oress N/A Philadelphia Electric Co. Type Code symbol stamp
- 3. Work Perforrned by N/A 2301 Market '9treet Aoino,i2ation No.
n/A Philadelphia, Pa. 19101 E,pi,,iion o,t,,,,, Accress System 41 Main Steam Relief Valve 4 identification of sytrem N/A Code Casa 68 Edition, Strtner 70 Ageeno. ASE III 19
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacement 1980, W, 81
- 6. Identification of Components Repaired or Feplaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Reptaced, (Yes Component Manufacturer Serial No.
No, identification Built or Replacement at No) PSV-041 MS Target Relief Valve Ibck 527 N/A 1F013 E 1979 Replaced, Y PSV-041 Beplace-MS Target Felief valve Pock 529 N/A 1F013 E 1980 ment Y PSV-041 Tar"i!et Poc 519 N/A 1F013 F 1979 Peplaced Y MS PSV-041 lep. Lace-j Felief Valve MS 7grGcrg Relief Valve rock.,,. 535 N/A 1F013 F 1980 ment Y Replace Main Steam Felief Valve
- 7. Description of work Hydrostatic 0 Pneumatic 0 uominai Operatino reisure W e
- 8. Tests Conducted:
440.. ps1 Test Temp.__. 1R4 ' F gy.y. Other @ Pressure __ supplemental sheets in form of lists, sketches, or crawings may be uwd. provided (1) size is 8% in. m d the number of sheets is NOTE: tion in items 1 through 6 on this report is included on ea:n sheet, and (3) each sheet is numbered an recorded at the top of this form. This Form (E00000) may be obtained ' rom be Order Dept., ASME,345 E.47th St.,New York, N.Y.10017 (12/82) -o W
.t. g. *./. ?.5-r s FORM NIS.2 OWNER'S REPORT FdR REPA!HS OR REPLACEMENTS As Required by'the Provisions of the ASME Code Section XI Philadelphia Electric Oompany o[ie' 7/25/86 s, owner 23U1 Market Stceet Philadelphia, Pa. 19101 4 9 33,,, Ac c.r ess ~ Limerick Generating Station unit Cl 2, Plant Evergreen & Sdh5 toga Ibads P.O. Box A, Sanatoga, Pa. 19464 m #8601862 & #8601863 Repair Organization P.O. No., Job No., etc., Ac oress N/A Philadelphia Electric Co. Type Coce symbot Stamp 1 Vlork Performed by N/A ZJU.L FarnetNa%reet Authorization No. . Philadelphia, Pa. 19101 N/A i Expir,iion pate Accress System 41 Main Steam Palief Valve 4 toentification of System N/A Code Case AMSE III 39 68 seition,_Sminer 70
- Acdenda, S. (a) Applicabte Construction Cod, (b) Ap,,,licable Edition of Section XI Utilized for Repairs or Replacements 19_SO, W, 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped Naticnal Name of Narne of Manufacturer Scard Otner Year
- Replaced, (Yes Comparant Manuf acturer Serial No.
N o. Identification Buijg or Replacement or No) l PSV-041 MS Target Relief Valve Pock 513 N/A 17013 G 1979 Peplaced Y PSV-041 Peplace-MS Target Relief Valve Pock 506 N/A 1F013 G 1979 ment Y PSV-041 MS Target Relief Valve Pock 523 N/A 1F013 H 1979 Peplaced Y j PSV-041 Peplace- { MS Target Pelief Valve Pock 531 N/A 1F013 H 1980 ment Y Peplace Main Steam Pelief Valve 7,. Description of Work
- 8. Tests Conducted: Hydrostatic 0 eneumatic 0 Nominal Operating Pressure
[g l Other @ Pressure... 990 . psi Test Temp. _ 184
- r
/v.3-g E Supplementiti sheets in form of lists, sketches, or drawings rnay be used, provided (1) size is 8% in.x 11 in., (2) informa. NOTE: tion in items i through 6 on this report is included en each sheet, and (3) each sheet is riumbered and the number of sheets recorded et the too of this form. This Corm (E00010) mov be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 112/82) W
\\; ' l .( A*. ?? *. > b + ) l s. FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 Philadelphia Electric Cotpany o,'t; 7/25/86 1 Owne, 2301 Market StT6dt 5 8 l Philadelphia, Pa. 19101 sheet f Accreu I Limerick Generatinti Station unit
- 1 f
- 2. Plant Evergreen & SdHEtoga Ibads MRP #8601824 & #8601864 P.O. Ecx A, Sanatoca, Pa.
19464 floosir Organization P.O. No., Job No., etc. Ac oress N/A
- 3. Work Performed by ' Philadelphia Electric Co.
Type Code symbol stamp N/A 2301 Market"S*3eet Authorization No. N/A Philadelphia, Pa. 19101 Expimion cate Accress Syds G mb Rem M.M Mve kKS 9 % e
- 4. identification of system v
N/A Code Casa 68 Edition, Summer 70 Addenda-ASME III 19
- 5. (a) Applicable Construction Code 80, W, 81 (b) Applicable Edit en of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME i
Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Comoo.unt Manufact.irer Serial No.
No. Identification Built or Replacement or No) D sn SPSV-04Y, f p MS Target Relief Valve Pock 518 N/A 1F013 J <: 4 979 Peplaced Y PSV-041 Peplace-M3 Target Felief Valve Fock 501 N/A 1F013 J 1979 ment Y PSV-041 MS Target Pelief Valve Ibck 515 N/A 1F013 K 1979 Replaced Y PSV-041 Peplace-MS Target Felief valve Ibck 505 N/A 1F013 K 1979 ment Y Replace Main Steam Relief Valve
- 7. description of Wor 6:
B. Tests Conducted: Hydrostatic Pneumatic 0 Nomir'ai Ooerarias Pressur. Other Q Pressure _ 990 ps; Test Temp. 1M y jo,3 g Supplemental sheets in form of lists, sketches, or drawings rnay be used, provided (1) size is 8% in. x 11 in., (2) inform NOTE: tion in items 1 through 6 on this report is inclucied on each sheet, and (3) each sheet is numbered and the number of g recorded at the top of this form. This Form (E0003C) rnay be obta;ned f rom the Order Dept., ASME,345 E. 47th St., New York,N.Y.10017 (12/82) l e*,
L ~ .q s. l - w. l ) o l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ~ \\ Philadelphia Electric Company g,',,- 7/25/86
- 1. owner 4JU1 Market btTeet 8
6 Philadelphia, Pa. 19101 .she,, Ad or ess
- 1 I
L merick Generating Station unit L Plant 1;vergreen & Sanatoga Ibads P.O. Box A, Sanatoga, Pa. 19464 MRF #8601856 &~#8601865 Repair Organi2st6cn P,0. No., Job No., etc. Ac cress N/A Philadelphia Electric O'xncany Type Code Symbol Stamp
- 3. Work Performed by N/A ZJU1 MarketNbtreet Autnerization No.
N/A Philadelphia, Pa. 19101 Esp;,etion oar, Ac cross %"" U DE E" MM MVe 4 identification of system ME III 19._.6O_ Edition, Stminer 70 Addenda _. M/A Code Case
- 5. (a) Applicaole Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1g 80, W, 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Coce
- Repaired, Stamped National Name of Name of Manu f acture r Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) l PSV-041 MS Pelief Valve get 521 N/A 1F013 L 1979 Replaced Y Peplace-MS Target Felief Valve Pock 532 N/A D'013 L 1990 mme v PSV-041 MS Target Felief Valve Ibck 522 N/A 1F013 M 1979 Replaced Y PSV-041 Peplace-MS Target Felief Valve Pock 508 N/A 1F013 M 1979 ment Y Peolace Main Steam Pelief Valve
- 7. Description of Work
[Yo.366 j
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other @ Pressure 990 psi Test Temp. 184 r
Supplemental sheets in form of lists, sketches, or drawings may b used, provided (1) size is 87 in. b of sheetsis NOTE: tion in items 1 throu0h 6 on this report is inclucied on each sheet, and (3) each sheet is numbered and the num er recorded at the top of this form. 1 l This rorm (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) l 2
+ _t- ~:;. s;. ) FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company g,tl 7/25/86
- 1. owne, 4,$U1 EarKet bt.rErfaL 8
Philadelphia, Pa, 19101 7 -of she,t Acor.n
- 1 Limerick Generating Station-unit
- 2. Plant t,vergreen & da::awga roacs P.O. Box A, Sanatoga, Pa.
19464 MPF #8601857 & #8601858 Repair Organization P.O. No., Job No,, etc. Ao oress N/A Philadelphia Electric Cb. Type Code symbos stamp
- 3. Work Performed by 4 * " * " " UL Authorization No*
N/A Philadelphia, Pa. 19101 N/A g,,,,,t,,n g,,, Address System 41 Main Steam Relief Valve 4 Identification of System N/A Code Case 19_ 68 Edition,Strrner 70 - Addenda _ S. (a) Acpticable Construction Code 60, W, 81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Ccde
- Repaired, Stamped National Name of Name of Manu f acturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) SbF PSV-041 Target yY-Rock g. 516 N/A 1F013 N 1979 Replaced Y c MS rdv-0il Fe lave-Relief Valve MS Target Relief valve Rock 533 N/A 1F013 N 1980 ment Y Fdv-u4.1. Relief valve Peck 528 N/A 1F013 S 1979 Replaced Y MS Target ydv-0si Fwi u_:c-l Felief Valve Pock 514 N/A 1F013 S 1979 ment Y ~ MS Target PEDlace Main Steam Pelief Valve I
- 7. Description of Work l
Hydrostatic C Pneumatic 0 Nomiaai Coersiina reisure o i e
- 8. Tests Conducted:
184 jf.3 6% Other @ Pressure 990 psi Test Temp. Supplemental sheets in form of lists, sketches, or drawings may be used,provided (1) size is 8% in. x 11 d the number of sheets is NOTE: tion in items 1 through 6 on this report is includ[ed on each sheet, and (3) each sheet is numbered an recorded at the top of this for-n. This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St.,New York, N.Y,10017 (12/82) l -s l
--.., - - ~ - - 3 f,. .v, l ,' a f. l., 3-PAGE 8 OF 8 1 4 l [ 3 FORM NIS.2 (Back), G. Remarks Applicable Manuf acturer's Data Reports to be ettsched - Target Pock Ort: oration IN-1 Forms and Associated MRF's are' attached. ~ ~ CERTIFICATE OF COMPLIANCE We certif y that the statements made in the report are correct and this T*hpl ers"k_ conforms to the rules of t 8 repaar or replacement 4 ASME Code, Section XI. ar Type Code symbol Stamp -N/A N/A Certificate of Authorization No,_ N/A expir, tion o,t, S 'El, $
- J19 ^ '
. $tr E D J Date Signed ___ pner or Oper's Design 6e, Tit /s[ CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure ~
- # "' b of and employed by. # 2' E
~ M'5'" or Province of have inspected the components described M l.4 CIN /M/" n and strte that
- rh
' ' ' M' to in this Owner's Report during the period _ d ibed in this to the best of my knowledge and belief, the Owne'r has performed examinations and takencorrective measures escr Owner's Report in accordance with the requirements of the ASME Code, Section XI, By signing this certificate neither the inspector nor his employer makes any warranty, expressed or i his employer examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor d h this shall be liable in any manner for any personal injury or property camage or a loss of any kind arising from or co inspection. r n ,a N [4. L I /*.".' ' Commissions '^ National Board, State, Province, and Endorsements / inspector's Signature ?i 19 6 p g. (12/82) a e -- r.
t ) FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As hequired by the Provisions of the ASME Code Section XI Philadelphia Electric Comcany o,',l 7/25/86 t g o,, 2301 Market Steet Philadelphia, Pa. 19101 1 of 5 sheet Accress
- 1 Limerick Generating Station unit
- 2. Plant ~ Evergreen & Sanatoga Icads l
P.O. Box A, Sanatoga, Pa. 19464 MRF #8601823 & #8601860 Repair Organirstion P.O. No., Job No., etc. Ac cress N/A Philadelphia Electric Cb. Type Code Symbei Stamp
- 3. Work Performed by N/A 2301 Market"6treet Authorintion No.
N/A Philadelphia, Pa. 19101 Espiracion o,te Adcress System 41 Main Steam Relief Valve ( Identification of System 68. Edition,Sunmer 70 Addenda N/A Code Case Eb III 19
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 160, W, 81 j
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Reptaced, (Yes,
Component Manufacturer Serial No. No, identification Built or Replacement or No) MSRV - Inlet Tarcet PSV-041 Studs & Nuts Poch 526 U/A 1F013 D 1979 Replaced Y PSV-041 Replace-l MSRV - Inlet Tar 5et 530 N/A 1F013 D 1980 ment Y ~ Studs & Nuts Icc PSV-041 ~MSRV - Inlet Target Studs & Nuts Ibck 527 N/A 1F013 E 1979 Reclaced Y PSV-041 Replace-MSRV - Inlet Target Studs & Nuts Pock 529 N/A 1F013 E 1990 ' ment Y Replace MSRV Inlet Studs & IMts
- 7. description of worg Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure C j
- 8. Tests Conducted:
Other Pressure psi Test Temp.
- F Supplemental sheets in form of Usts, sketches. or drawings may be used,provided (1) size is 8% in. x 11 in.
fh i j NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is nuinbered and the number o s recorded at the top of this form. rnay be obtained f rom tne Order Dept., ASME,345 E. c.7th St., New York, N.Y.10017 (12/82) This Form (E000001 S
e ___. I+ } S FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provnions of the ASME Code Section XI Philadelphia Electric Company osce" 7/25/86 3, 3 n,, 230.1. Market Street Philadelphia, Pa. 19101 2 5 3n,,1 o, Accress N1 INTEriCk Generating Station Unit
- 2. Plant Evergreen & Safic'Ebga Ibads P.O Bem A.
c;anatoca. Pa. 19464 MRP #8601861 & #8601863 Ac oress ~ Roosir Organization P.O. No., Job No., etc. Philadelphia Electric Cb. Type Code Symbol Starno N/A
- 3. Work Performed by 2301 Markef."$6reet Authorization No.
N/A Shil M olnhiM. PA. 19101 Expiration Cate M/E Accress System 41 Main Steam Palief Valves 4 Identification of System AbE III 19.6 8 Edition, Su:Traer 70 N/A Addenda _. Code Case
- 5. ka) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, W, 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamps d National Name of Name of Manufacturer Scard Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No, identification Built or Replacement or No) PSV-041 MSRV - Inlet Tar ~{et 519 N/A 1F013 F 1979 Replaced Y Foc} Studs & Nuts PSV-041 Replace-MSRV - Inlet Tarcet Studs & Nuts Ibck 535 N/A 1F013 F 1980 ment. Y PSV-041 MSRV - Inlet Target Studs & Nuts Ibck 523 N/A 1F013 H 1979 Replaced Y PSV-041 Peplace-MSRV - Inlet TEet l 531 N/A 1F013 H 1980 ment Y Studs & Nuts P Peplace MSW Inlet Studs & Nuts
- 7. Description of Work 1
Pneumatic C Nominal Ocerating Pressure O i
- 8. Tests Conducted: Hydrostatic.
Other O Pressure ' -. a si Test Tema-r l Supplemental sheets in f orm of lists, sketches, or drawings may be used, provided (1) size is 83 in. x 11 in., (2) informa-l NOTE: tion in items 1 through 6 on this report is included on each sneet, and (3) each sheet is numbered and the number of sheets recorded at the top of this forrn. This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E.47th St.,New York, N.Y.10017 (12/82) i
e ) 0 s FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Carpany g,;,- 7/25/86 ,,,,,, 2301 Market Street 5 Philadelphia, Pa. 19101 Sheet of Acoress
- 1 Limerick Generatino Station unit
- 2. Plant Evergreen & Sanatega Poads P.O. Box A, Sanatoga, Pa.
19464 MRF #8601856 & #8601857 Repair Organization P.O. No., Job No., etc. Ac oress Work Performed by Philadminhia Flectric Nany Type Code Symbol Stamp ..N/A 2301 Market Street N/A Authorization No. N/A Philadelphia, Pa. 19101 g,,ir,1;oo o,,, Ad dress Systen 41 Main Steam Relief Valve
- 4. Identification of System N/A Code case MME III 19 68 _ Eeition, Summer 70 Addenda-
- 5. (a) Applicable Construction Code
!bl Applicable Edition of Section XI Utilized for Repairs or Replacements 1SO, W, 81
- 6. Identification of Components Repaired or Replaced and Replacement Components l
ASME Code
- Repaired, Stamped Natronal Name of Name of Manu f acture r Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement orNo) PSV-041 MSW - Inlet Target Studs & Nor.s Fock 521 N/A 1F013 L 1979 Replaced Y PSV-041 Replace-MSW - Inlet Target Studs & Nuts Fock 532 N/A 1F013 L 1980 ment Y PSV-041 MSW - Inlet Tar ~et Str.ds & Nuts FocN 516 N/A 1F013 N 1979 Peplaced Y l PSV-041 Replace-l MSRV - Inlet Target Studs & Nuts Pock 53 N/A 1F013 N 1980 ment Y l Peplace MSW Inlet Studs & Nuts
- 7. Description of Work B. Tests Conducted: Hydrostatic 0 eneumetic "omiaei operatiao ressure O a
Other Pressure psi Test Temo.
- F o
NOTE. Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) site is 8% in, x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) -o. n
1 l ) FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric (bmpany o,il 7/25/86 3, 0,ne, 2301 Market Stit9?t 4 5 j Philadelphia, Pa. 19101 She,, Accress
- 1 Limerick Generatina Station unit
- 2. Plant Evergreen & SaWa Ibads P.O. Box A, Sanatoaa, Pa.
19464 MRF 48601822 Repair Organization P,0. No., Job No., etc. Ao cross N/A
- 3. Work Performed by Philadelphia Electric Co.
Type Coce symbol Stamp l N/A 2301 Market StThet Authorization No. N/A Philadelphia, Pa. 19101 Expiration case Ad dress SVStem 41 Main Steam Relief Valve f
- 4. Identification of System N/A Code Case Su:mer 70
- Addend, MS 68 Estion
- 5. (a) Applicable Construction Code 19 (b) Applicaole Edi+. ion of Section XI Utilized for Repairs or Replacements 19 8 0, W, 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Camponent Manufacturer Serial No.
No. Identification Built or Replacement or No) 9 C n, PSV-041 MSRV-Inlets $.,T et Studs & Nuts / 520 N/A 1F013 B 1979 Replaced Y PSV-041 Replace-MSRV - Inlet Target Studs & Nuts Ibck 534 N/A 1F013 B 1980 ment Y a L Sh
- es
- 7. Description of work Wof en MA7 Trd e Chide:
- 8. Tests Conducted: Hydrostatic C Pneumatic Nominal Operating Pressure O Other O Pressure
. psi Test Temp.
- F Supplemental sheets in form of lists, sketches, or drawings rnay be used, provided (1) size is 8% in. x 11 in., (2) Inf f
i NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o sheet recorded at the top of this form. This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82)
e.,. c n a S. PAGE 5 OF 5 FORM NIS.2 (Back),
- 9. Remarks Applicable Manuf acturer's Data Fleports to be attached Tarcjet Ibck Corporation NV-1 Fom and Aeme inw MRP's ars atteNa CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _*Anl ne'mmtconforms to the rules of th "D**"'''**"* F.
ASME Code, Section XI. N/A Type Code Symbol Stamp _ N/n N/A Expiration Date Certificate of Authorization No. 8b $7 19 M $^tu Date (/ Signed. (/ gwner or oper's Designee. T Ale CERTIFICATE O F INSE RVICE INSPECTION. 1, the undersigngAho6 ding a vafid commission issued by the National Board of Boiler and Pre U~'# b I" of *E*' and employed by or Province of /~ have inspected the components described
- /ck:<6 ys
'"b -3 yam - and state that ' '~ N - to-res described in this in this Owner's Report durin0 the period _ i to the best of my knowieoge and belief, the Owner has performed examinations and taken correct ve measu l Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed o his employer examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor d with this shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or co inspection. e' _M. - _ Commissions Y National Board, State. Province. and Endorsements inspector's Signature 19 Date (12/82) ,T. l -o i I
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company' cate _ Aucus t 25. 19R7 1, Owner 2301 Market Stre"e'*t I 8 of Ph41ndelnhin. pn-lotn1 Sheet Acoross One ' 2. Plant Limerick Generating seneinn unit Evergreen and 'S'Effatoga Roads P.O. Box A,'Sanatora. Pa. 19464 MR 1:- #R7nt?no ena R7nt?in-Flopast Organss ation P.O. No., JoD No., etc. Adoress Philadelphia Electric Company Type code Symbol Stamp N/A 3, Work Performed by N/A Authorizati n No. 2301 Market Street N/A Philadelphia. Pa. 19101 Expiration Date Ad oress System'41 Main Steam Relief Valve ' 4. Identification of System 5.' (a! Applicable Construction Cot's ASME III _19_f.6_ Edition, Summer 70 Addenda,_ N / A Code Case (b) Applicable Edition of See:.c.1 XI Utilized for Repairs or Replacements 19 80. E 81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or Noi MS Target PSV-041 Relief valve rock 510-N/A IF011A 1979 Reninced V MS Tarket PSV-041 Replace-Relief valve rock 517 N/A IF011A 19AO mene Y MS Target PSV-041 Relief valve rock 534 N/A 1FO11R 19AO Reninced V MS Target PSV-041 Replace-Relief valve rock 520 N/A IF013B 19R0 mene V Replace main steam relief valve. 7, Description of work Hydrostatic 0 Pneumatic 0 "omine' Oaeratina Pressure O
- 8. Tests Conducted:
Other h Pressure 1000 psi Test Temp. 187 'r Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) sl2e is 8% in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sh NOTE: recorded at the top of this form. This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) \\ N
e 4 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. ' Owner Philadelphia Electric Comenny Date Auence M.
10R7 ~ 2301 Market Stre&T Philadelohin. Pa. 19101 Sheet 7 of R Acoress 2.. Plant TJmorick Genevnting Erneinn Unit Ono Evergreen and SahTtoga' Roads P.O. Box A. Sanatoen. Pn. 19464 vur#R7n1911 ena 97nq??? Reoasr Organization P.O.~ No., Job No., etc. Accross '
- 3. Work Performed by Phi 1 sulp1 nh4 n F1 pe rv4 r-Innnnny Type Code Symbol Stamp M If_
Authorization No, M/4 '2301 Markee Street Philn.. Pa. 19101 Expiration Date M/A Ac oress
- 5. I' identification of System EvcPam di - Mnin Meanm R o 14 a f 11m l ere
- 5. (a) Applicable Construction Code ACMP TTT 19_fd Edition, c,,mmo
- 7n. Addenda, M If Code Case An tr, 81 (b) Applicable Edition of Section XI Utilized $or Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components
'ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced,
- (Yes Component Manufacturer Serial No. No. Identification Built or Replacement or No) PSV-041 MS Target n.14,,5 ,re wr. e m.1, <1t~ PSV-041 ~~iono na-a v M/A t eni w RUlace! ~ MS Target Relief valve rock 525 N/A 17013C 1980 ment Y PSV-041 MS Target Relief valve rock 530 N/A 1F013D 1980 Reolaced Y PSV-041 Replace-MS Target Relief valve rock 526 N/A 1F013D 1980 nent Y Replace main steam relief valve
- 7. Description of work Hydrostatic 0 Pneumatic O Nominal Operating Pressure O
- 8. Tests Conducted:
Other @ Pressure _ 1000 psi Test Temp. 187 'F Supplemental sheets in form of lists, sketches, or drawings may be used,provided (1) site is 84 in. x 11 in., (2 tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o NOTE: recorded at the top of this form. This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) -- o.
? FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company oat. Aucust 25. 1987 1, Ownr;r 2301 Market S tft'Et Philadelphia, Pa. 19101 Sheet 3 of R Accross Limerick Generating Station Unit One
- 2. Plant Evergreen and 263 toga Roads P.O. Box A. Sanatona. Pa. 19464 Mnv #R7n1911 ona R7n37tA Flopeer Organaretion P.O. No., JoD No., etc.
Ad dress N/A Philadelphia Electric Company Type Code Symbol stamp
- 3. Work Performed by N/A 2301 Market Street Name Authorization No.
N/A Philadelphia, Pa. 19101 E,piration pare Address System 41 - Main Steam Relief Valve
- 4. identification of System N/A Code Cne Summer 70 Addenda,_
68 _ Eoition, ASME III 19
- 5. (a) ApplicaDie Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80,J, 81
- 6. Identification of Components Repaired or Replacsd and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification BuDt or Replacement or No) MS Target PSV-041 Relief valve rock 529 N/A 1F013F 14RO Ran1nced V MS Target PSV-041 Replace-v Rn14ef vn1va vnck 477 v/A 1rn13r tagg egne PSV-041 MS Target A v Relief vn1va rnck sts v/a Irn13r togg t> g pin g Replace-MS Target PSV-041 Relief valve rock 519 N/A 1F011F 1980 mene v
- 7. Description of Work Replace main stenm relief vniva Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure C
- 8. Tests Conducted:
Other @ Pressure _1000 psi Test Temp. 1R7 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) i tion in items 1 through 6 on this report is included on each sheet, and (3) aach sheet is numbered end the number of s recorded at the top of this form. This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y 10017 (12/82) -a.
7 L' FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI ' August 25, 1987 1,' Owne,' Philadelphia Electric ' Company o.,, 2301. Market Str&&T' Philadelphia,' Pa. 19101 Sheet 4 of A Aooress
- 2. Plant Limerick Generating Station Unit Ono Evergreen.and ShtGioga Roads P.O. Box A. Sanatona. Pa.
19464 MR 1:- 4R7n1919 ena A7n191A Rooe6r Organiz ation P.O. No., J0D No., etc. Ao oress
- 3. Work Performed by Philadelohin Eleerric Comenny Type Code Symbat Stamp M/A Authoriastion No.
M/A' 2301 Market Street Philadelphia. Pa. 19101 Expiration 'Oate M/A Ao oress 4 Identification,f System System 41 - Mnin cennm rolief valvo 5 ' (a) Applicable Construction Code A AMF TTT 19 6 A Edition Atimmoe 70 . Addenda. M/A Code Case ' (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19_ RO. IJ, $1
- 6. Identificati,on of Components Repaired or Replaced and Rep!acement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) PSV-041 MS Target Relief valve rock 506 N/A 1F011C 1979 Ren1ncerl -Y PSV-041 Replace-MS Target Relief valve rock 513 N/A 1F013C 1979 mene Y PSV-041 MS Target n.14.e vn1v, enck 511 M/A trniin topn nom,er.a v PSV-041 Replace-MS Target Relief valve rock 523 N/A 1FOl3H 1980 ment Y
- 7. Description of Work Reolace main steam relief valve Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O 8 Tests Conducted:
Other Q Pressure _1000 pai Test Temp. 1A7
- F Supplemental sheets in form of lists, sketches, or drawings may t>e used, provided (1) site is 8% in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, end (3) each sheet is numbered and the number of sh NOTE:
recorded at the top of this form. This Form (E00030) may be obtained f rom the Order Oept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) -e I
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Reguired by the Provisions of the ASME Code Sectior XI August 25, 1987 Philadelphia Electric Company o,1, 1 owner 2301 Market StrWt Philadelphia, Pa. 19101 Sheet 4 of g Ad oress limerick Generating Statiop Unit ona
- 3. Plant Evergreen and #A6htoga Roads P.O. Box A Sanatoca. Pa.
19464 var /tg7n37 n 2nd 0702220 Repair Organiz ation P.O. No., JoD No., etc. Ad dr ess Philadelphia Electric Company Type Code Symboi Stamp N/A
- 3. Work PerfEIOT byMarket Street Name Authorization No.
N/A l Phila., Pa. 19101 Expiration oste N/A l Ad oress System 41-Main Steam Relief Valve 4 Identification of System 68 Edit;on, Summer 70 Addenda. N/A Code Case ASME III 19
- 5. (a) Applicable Construction Cod,
- 80. W, 81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Comnonents Repaired or Replaced and Replacement Components ASME Code Repaired.
Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.,
No. Identification bud: or Replacement or No) MS Target PSV-041 Relief vnive rnnk Ent n/A trninv sn-n n__,___, i UU-641 Nep[ ace" MS Target Relief valve rock 51R I N/A 1Fn117 1onn ,,. e., e v MS Target PSV-041 Relief valve rock 505 N/A 1F019Y 1070 pan 1ncoa v MS Target PSV-041 Replace-Relief valve rock 515 N/A 1F011Y 10An mone v Replace main steam relief valve
- 7. Description of Work Hydrostatic O eneumatic 0 Nominal Operating Pressure C B. Tests Conducted:
Other @ Pressure 1000 psi Test Temp. IR7
- F Supplemer tal sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in.,
i tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of s NOTE: recorded at the top of this form. This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82)
FORM NIS.2 OWNER'S REPORT FOR M' PAIRS OR REPLACEMENTS As Required by the Provisions of ths tSME Code Section XI Philadelphia Electric Company o,, August 25, 1987
- 1. Owner 2301 Market Strtse 8
6 og Philadelphia, Pa. 19101 sh.: AcorWss One 1.imerick Generating Station unit
- 2. Plant Evergreen and Sattet'oga Roads P. O. A, Sanatoga, Pa.
19464 MRF# 8703221 and 8703222 Raps 6r Organization P.O. No., Joo No., etc. Accross Philadelphia Electric Company Type Code symbol stamp N/A
- 3. Work Performed by N/A 2301 Market Street Authorization No.
N/A Philadelphia. Pa. 19101 Expiration Date Ac cross System 41-Main Steam Relief Valve
- 4. identification of system 5, le) ApplicaDie Construction Code ASME III
__1968 Edition, Summer 70
- Addenda, N/A Code Case (b) Applicatie Edition of Section XI Utilized for Repairs or Replacements 19 80. W. 81 l
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Repa, red.
Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) PSV-041 l MS Target l Relief valve rock 532 N/A IF013 L 1980 Renlaced Y PSV-041 Replace-l MS Target Rnlief vnive rock 971 N/A f ro117 10A0 mann v PSV-041 MS Target Relief valve rock 508 N/A 1F013M 1979 Renlaced Y PSV-041 Replace, MS Target 1980 I y Relief vn1vn vncle 977 N/A. 1rO11M Replace main steam relief valve. 7 Description ot Work Hydrostatic 0 Pneumatic 0 Nominal Operating Pressues O
- 8. Tests Csnducted:
Other @ Pressure 1000 psi Test Temp. _ 187 'F I supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o NOTE: recorded at the top of this form, This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St', New York, N.Y.10017 (12/82) -,m l I .__-__--_____a
FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI August 25, 1987 Philadelphia Electric Company n,1,
- 1. Owner w.m.
2301 Market Street 7 of b Philndelnhin. Pn. 19101 Sheet Accross Limerick Generating Station unit One
- 2. Plant Evergreen and S$*n"a'* toga Roads MRF#8703223 and 8703225
- v. n. nw A-sam enen-pn-t o m _.
Accross " Repair Orgen62enon P.O. No., JoD No., etc. Philadelphia Electric Company Type Code Symbol Stamp N/A =
- 3. Work Performed by N/A Auth rizati n No.
2301 Market Street N/A Phiindelnhin. Pa. 19101 Expiration Date Adcross System 41 - Main Steam Relief Valve
- 4. Identification of System ASME III 3g 68_Editinn, Summer 70
- Addenda, N/A Code Case
- 5. (a) Applicable Construction Code 80,w,81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identificati,on of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) PSV-041 MS Target v Relief valve ' rock 511 N/A 1 F01 W 10RO p a g n e. n A MS Target PSV-041 Replace-y Reli f vnivo v n e t, <fA v/q 1791p igog MS Target PSV-041 Relief valve rock 514 N/A 1F011R 1Q7Q con 1mroA v MS Target PSV-041 Replace-Relief valve rock 528 N/A 17011A 10RO -one v Replaced main steam relief valve
- 7. Description ot Work Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O
- 8. Tests Conducted:
Other @ Pressure 1000 psi Test Temo, io' 'F Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 6% in. x 11 in., fh i NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number o s eets f recorded at the top of this form. This Form (E00030) mov be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) -o I i 1 1 a
FORM NIS 2 (Back) Target Rock Corporation NV-1 forms, associated MRF's, certificate-
- 9. Remarks AppliceDie Manuf acturer's Data Reports to De attacheo of conformance of certification test reports and valve / pump examination check off list data sheet are attached.
CERTIFICATE OF CoMPLlANCE replaceClent conforms to the rules of the We certify that the str:ements inade in the report are Correct and thisrepw or repiscent ASME Code, Section XI. N/A Type Code Symool Stamp _ N/A N/A Expiration Date Certificate of Authorization No._ E3 // ,19 d Date $;gned ov mer or owner's ossignee. Title / CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, hMding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State fM N#"' b' # 7*O "W of 8MM' and employed by or Provin e of 4/2 A bbA///r have inspected the components oescribed 7//f/S7 and state that (a /J2 4/ / 97 to in this Owner's Report during the period / / / to the best of my knowledge and belief, tne Owner has performed examinations and taken corrective measures described in this Owner's Report in accorJance with the requirements of the ASME Code. Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. S 7D~d~ Commissions ~.1,o n., o o.ro.. tat...,..,nc...no. n.o,s._.nt. ,n.pyo s...n.g r l U 9//6 19 Date f (12/82) l -o n E __
FORM N!S 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9/11/87 Philadelphia Electric Company o,,, t, owner N m. 2301 Market Street I 8 Ph 41 n e191 nhi n, Pn_ 19101 Sheet of Aoor.ss One 2, Plant Eimerick GeneratinR Station unit s.mo Evergreen and Sanatoga Roads MRF #8703209 and 8703210 P. O. Env A. Rnnntocn_ Pn_ 14464 Ac cross ~ Repair Organsretion P.O. No., Job No., etc. N/A Philsdelt3hia Eleetric Company Type Code symbos stamp
- 3. Work Performed by N/A Authorization No.
) 2301 Market Street N/A l Philadelphia. Pa. 19101 Empirauon Date Ac atess identification et system System 41, Main Steam Relief Valve l 4 N/A ,,__coe.c.,
- 5. (a) Apphcacie Construction Code ASME III 39 68 seition, Summer 70
- AcMenda, 80,W.81 (b) Applicsoie Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Ice,t fication of Components Repaired or Replaced and Replacement Components i
ASME Code R ep aired, Stamped f National l Name of Name of Manufacturer Board Other Year
- Replaced, (Yes l
Component Manuf acturer Senal No. No. Identification Built or Replacement or No) PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013A Replaced Y FSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013A ment Y PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013B Replaced Y ~ PSV-041 Replace = MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013B ment Y
- 7. Description of Work Replace MSRV Inlet Studs & Nuts Hydrostatic h Pneum 8 tic ] Nominal Operating Pressure O
- 8. Tests Conducted; Other @ Pressure 1000 psi vest Temp. 187
- r Supplemental sheets in form of lists, sketches, or drawings rnay be used, provided (1) size is BM in. x 11 in., (2) informe-NOTE:
tion in items 1 through 6 on this report is incluced on each sheet, and (3) each shaet is numbered and the nurnber of sheets is recoroed at the top of this form. This Form (E00030) may be obtainea f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82)
- Years built 1979 and 1980
- Years built 1979 and 1987
) l J
a r l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l As Required by the Provisions of the ASME Code Section XI w Philadelphia Electric Company osie 9/11/87 g, o,n,r s.m. 1 2301 Market Street Ph41nAalnhin. Pn. 1Q101 Sheet 2 of 8 Accress
- 2. Plant limerick Generating Station Unit One s m.
Evergreen and Sanatoga Roads MRF#8703211 and 8703212 P-n_ Rnv A_ clnnnen e. ps 1QAAA Roosar Organization P.O. No., JoD No., etc. 'Ac cr oss N/A
- 3. Work Performed by Philmdpinhin Electric Company. Type Code Symbot Stamp
^ "'" "z a ti n No. N/A l 2301 Market Street Philndelnhin. Pn. 19101 Expiration Date N/A .j j Accross i Svstem 41 - Main Steam Relief Valve
- 4. Identification of System S. (a) Applicaole Construction Code ASME III 1933_,, Edition,S ume r 70
. Addenda, N/A Code Case (b) Applicaole Edition of Section XI Utilized for Repairs or Replacements 19 80.w.81
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code Repaired.
Stamped Nationat Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) MSRV-Inlet Target PSV-041 Studs & Nuts Rock N/A N/A I1F013C Replaced Y MSRV-Inlet Target PSV-041 Replace-Studs & Nuts Rock N/A N/A 1F013C ment Y l MSRV-Inlet Target PSV-041 Replaced Y Studs & Nuts Rock N/A N/A 1F013D __ Replace-PSV-041 MSRV-Inlet Target ment Y Studs & Nuts Rock N/A N/A _lF013D. Replace MSRV Inlet Studs and Nuts.
- 7. Description of Work f
Hydrostatic C Fneumatic 0 Nominal Operating Pressure O
- 8. Tests Conducted:
Other Q Pressure 1000 psi Test Temp. 1R7 'F j i \\ Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) Cze is 8Ys in. x 11 in., (2) informa-NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l ) recorded at the top of this form. This Form (E00030) rnay be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) l
- Years built 1979 and 1980.
l
- Years built 1979, 1987.
j
1 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i 1 9/11/87 Philadelphia Electric Company osie 1, owner s.m. 2301 Market Street 3 of 8 phyigdg1phin p3_ 10101 Sheet Acoress 2 Plant T.4 mov4 cle conovne4no Mene4nn Unit One s.m. - Evergreen and Sanatoga Roads _ MRF #8703213 and 8703214 3 e_ _ n_ _ u,,
- 4., e,.,.g
- m. g. _,
e_ _,_ i o, m... Repair orgomastion P.O. No., Job No., etc. N/A Floc *v4e Npany. Type Code Symbol Stamp
- 3. Work Performed by ph41nAalph4n
^"'" ' ' ' ' " " " - 2301 Market Street Db41nAalnh4n pn 10101 i'apiration oste N/A Acoress 4 identification of System Replace MSRV Inlet Studs and Nuts
- 5. (a) Applicable Construction Code ASME III 19 68 Edition. Summer 70 Addends.N / A Code Case I
80 w.81 l (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME
} Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Y ear
- Replaced, (Yes Component Manuf actu rer Serial No.
No. Identification Built or Replacemer.: or No) PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013E Reolaced Y PSV-041 Replace-MSRV-Inlet Target Studs & Nats Rock N/A N/A 1F013E ment Y MSRV-Inlet Target N/A N/A PSV-041 Studs & Nuts Rock 1F013F Replaced Y PSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A IF013F ment Y System 41-Main Steam Relief Valve
- 7. Description of work Hydrostatic ] Pneumatic C Nominal Operating Pressure O
- 8. Tests Condurfed:
Other @ Pressure 1000 psi Test Temp. 1R7 'F Supplemental sheets in f orm of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) ea::h sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E000301 may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017
- Years built 1979 and 1980.
- Years built 1979, 1987.
3 r FORM NIS 2 OWNER'S REPORT FOR REPAtRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9/11/87 Philadelphia Electric Company o,ie 1, Owner name . 2301-Market Street-A 8 Philadelnhin. Pn_ 19101 Sheet of Ac orou
- 2. ' Plant
' Limerick Generating Station Unit One s.m. Evergreen and Sanatoga Roads MRF #8703215 and 8703216 P. n_ Rnv A Annnenen Pm-1QAAA Accran Receir Organis ation P.O. No., JoD No., etc. N/A
- 3. Work Performed by Phi 1 adelnhia Electric Company. Type Code Symool Stamp I
Authorizati n No. N/A 2301 Market Street Philndelchin. Pn. 19101 Expiration Date N/A Ac cress System 41 - Main Steam Relief Valve
- 4. Identification of System N/A coe, c,s,
-5. (a) Applicable Construction Code ASME III 19 68 Edition Summer 70 __ Addenda. 80,w,81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 i
- 6. Identification of Components Repaired or Replaced and Rectacement Components I
ASME Code
- Repaired, Stamped National Name of -
A me of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement. or No)- PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013G Replaced Y PSV-041 Replace-MSRV-Inlet Target _.Sluds & Nuts Rock N/A N/A 1F013G ment Y PSV-041 MSRV. Inlet Target Studs & Nuts Rock N/A N/A 1F013H Replaced Y PSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013H ment Y l
- 7. Description of Work Replace MSRV Inlet Studs and Nuts Hydrostatic ] Pneumatic O Nomiaai Ooersiian Pressure O
- 8. Tests Conducted:
Other @ Pressure 1000 psi 7est Temp, 187
- p Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa.
NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is . recorded at the top of this form. 4 W 82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
- Years built 1979 and 1980.
l
- Years bult 1979, 1987.
1 1 I h J
r FORM NIS.2 OWNER'S REPORT FOR REPAtRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9/11/87 Philadelphia Electric Company o,te 3, o wner Name 2301 Market Street 5 of 8 Phi l a rini nhi n. Pn. 19101 Sheet Ao ores One
- 2. Plant Limerick Generating Station unit Name Evergreen and Sanatoga Roads MRF# 8703218 and 8703220 P.
O. Env A. Rnnnenen. Pn_ 14464 ~Acoross ~ Reocer Organization P,0. No., JoD No., etc. N/A Philadelphia Electric Ccapany - Teos Code Symool Stamp
- 3. Work Performed by N/A Authorizat:on No.
2301 Market Street N/A Philad elphia.._ Pa. 19101 Expiration Date Ao oress System 41 - Main Steam Relief Valve 4 Identification of $vstem N/A Code Case
- 5. (a) Applicable Construction Code ASME III 39 68 Eoii;on, Summer 70
- Addenda, 80.w,81 (b) Applicaole Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped Nationat Name of Name of Manuf acture r Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A IF013J Replaced Y PSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A IF013J ment Y PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013K Replaced Y PSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A IF013K ment Y
- 7. Description of Work Replace MSRV Inlet Studs and Nuts.
- 8. ~ Tests Conoucted; Hydrostatic Pneumatic 0 uomina' Ooeratias Pressure O Other @ Pressure 1000 ps; Test Temp.
187 'F Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa. NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is, recorded at the top of this form. This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 (12/82)
- Years bult 1979 and 1980.
- Years built 1979, 1987.
I 1
~ i r FORM NIS 2 OWNER'S REPORT FOR. REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 9/11/87 Philadelphia Electric Company cate t, Owner Nam. 2301: Market Street 6 8 of ph41sAalnh4n._)s 10101 Sheet 4doress,
- 2. Plant T.4 me ri cle Conprneini hntinn Unit One Name ~
Evergreen and Sanatoga Roads MRF# 8703221 and 8703222 iom p n um, a c om,* m e ne--' Rooser creatur stron P.o. No., Joo No., etc. -~U 'Aocross N/A
- 3. Work Performed by Ph 41 m elai nh i n Fl a c evi r- ('amnany Type Code SymboI Stamp '
"**f Authorization No. N/A 2301' Market Street Ph41 m elpi nhi n. Pn. 19101 Expiration Date N/A Ac oress System 41 - Main Steam Relief Valve 4 identification of System N/A Code Cas. Summer 70 Addenda,
- 5. (a) Applicable Construction Code ASME III 19 68 E dition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80,w,81 6.' identification of Components Repaired or Replaced and Replacement Components ASME Code R epaired, Stamped Natione.
Name of Name of Manufacturer Board Other Year Repla:id, (Yes Component Manufacturer Serial No. N o. Identification Built or Replacement or No) MSRV-Inlet Target PSV-041 Studs & Nuts Rock N/A N/A 1F013L Replaced Y MSRV-Inlet Target PSV-041 Replace-Studs & Nuts Rock N/A N/A 1F013L ment Y MSRV-Inlet Target PSV-041 Studs & Nuts Rock N/A N/A 1F013M Replaced Y MSRV-Inlet Target PSV-041 Replace- _S,tuds & Nuts Rock N/A N/A 1F013M ment Y 7.' Description of Work. Replace MSRV Inlet Studs and Nuts. Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure O
- 8. Tests Conducted:
Otner @ Pressure 1000 ps; Test Temp. 187 'F ~ Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in, x 11 in., (2) Informa. NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
- Year.s built 1979 and 1980.
- Years built 1979, 1987.
1 l-E_____--____-____- l
~ FORM N!S 2 OWNER'S REPORT FOR REPAtRS OR REPL ACEMENTS As Required by the Provisions of the ASME Code Section XI 9/11/87 Philadelphia Electric Company o,te 3, o,n,, N me 2301 Market Street 7 of 8 Ph41 nan 1nh4n. Pn_ 14101 Sheet Ac aress
- 2. Plant Limerick Generatine Station
- uni, One Name Evergreen and Sanatoga Roads MRF#8703223 and 8703225 P.
O. Rnv A. Annn f non. Pn_ 1Q664 'Ad dr ess ~ Repair organu suon P.o. No., Joo No., etc. N/A s
- 3. Work Performed by Philadelphia Electric Company, Type Code svmbol Stamp N/A Auth ritation No.
2301 Markee Street N/A Philadelphia. Pa. 19101 Expiration Date Aa aress SYSOem 41 - Main Steam Relief Valve 4. identification of Syste n N/A Code Case
- 5. (a) Applicaote Construction Code ASME III 19 68 Edition. Summer 70 Addenda, 80,w,81 (bl Applicaole Edition of Section XI Utilized for Repairs or Replacements 19
- 6. loentification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manu f acturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identdication Built or Replacement or Non i PSV-041 MSRV-Inlet Target Studs & Nuts Rock N/A N/A 1F013N Replaced Y PSV-041 %eplace-MSRV-Inlet Target Studs & Nuts Rock N/A N/A IF013N bent Y MSRV-Inlet Target ,PSV-041 Studs & Nuts Rock N/A N/A
- 1F013S Replaced Y
i PSV-041 Replace-MSRV-Inlet Target Studs & Nuts Rock N/A l N/A 1F013S ment Y
- 7. Description of work Replace MSRV Inlet Studs and Nuto.
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure C Cther @ Fressure 1000 psi Test Temp.
187 'F Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this f orm. (12/82) This Fcrm (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 i .** Years built 1979 and 1980. f
- Years built 1979, 1987.
l l l
f FORM NIS.2 (Back) Target Rock Corporation N-2N Form. Target Rock Corportition NV l' Forms, 3
- 9. Remarks Applicante Manuf acturer's Data Reports to be attached Becittel Construction. Inc.. Certificate of Conformance, associated MRF'ss.
and boltine examination check off list data sheet are attached. CERTIFICATE OF COMPLlANCE replacement conforms to the rules of the We certify that the statements made in the report are correct and this'D*"'*'""' .ASJVIE Code, Section XI. o N/A Type Code Symbol Stamp N/A N/A Expiration Date Certificate of Authorization No. D /I _19 1 -d L Date Signed Owner or owner's Designes, Titte CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State AMM bh bb T~O* ohm b-of 7MM and employer 1 by or Province of 44 48 bo4Ade have inspected the components described / O . and state that in this Owner's Report during the period _ /%67 ~ to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownar's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this insoection. EY e - Commissions ~ ' ' " ' ' ' ' ' ' ' ' ' ' " Ing.t.r.s s.g"d'- Date // 19_ _ _ / (12/82) l i ) { ) ^"'a------u_-_---,_a__n_a__u,,
FORM NIS 2 (Back) Repair was pefformed in accordance with ASME XI, MDCP 964, Rev. 1,
- 9. Remarks Applicable Manufacturer's Date Reports to be attached Specification 8031-G-33, Rev. 2, ERRFs L-239 and L-254, and the CJM (Construction Job Memorandum). The valve NPV-1 Data Report is attached.
CERTIFICATE OF COMPLIANCE Replacement conforms to the rules of the We certify that the statements made in the report are correct and this '*8*i'"D'**"' ASME Code, Section Xl. /A Type Code Symbol Stamp N/A N/A Expiration Oate Certificate of Author' a ic No. Limerick Section Mech. Branch Head - 17 Signedfid o,,, 3, owner or owners OWTee~ title y g CERTIFICATE OF INSERVICE INSPECTION f, the undersign d, holdin a vali commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Hartford Steam Boiler inspection 6 of nnsy van a and employed by or Province of Hartford, Connecticut h.vps,gycyth,gogn,gt, d,,C,;,,d e n bM N to and state that in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repor* in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector not his employer shall be liable in any menner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. b e M Commissions ,,.o .. s,..n. u,e m e,,on...oro.....e,r...ne s..no. _,se_en,s 7 oLy ,, u Os,e (12/82) -o
Lb e FORM NIS 2 CWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Requ;ted by the Provisions of the ASME Code Section XI June 24, 1986
- 1. owner Philadelphia Electric Co. (PECo) ooge 2301 Market Street N***
I of 3 Philadelphia, PA 19101 Sheet Address 3.' Plant Limerick GeneratinF Station Unit One (1) New Evergreen Road Pottstown, PA 19464 PECo Mod 964 Adorses rispoir orpenisation P.O. No., Job No., etc.
- 3. Work Performed by Philadelphia Eleetric Co.
Type Code Symbol Stemp N/A Authorization No.._ N/A Construction Division N'** Limerick Section Empiration Date N/A Pottstown, PA 19466aurm
- 4. Identification of System Reactor Water Cleanup System (44)
- 5. (a) Applicable Construction Code ASME.III ig 74 Edition, Winter'74 Addenda.
N/A Code Case (b) Applicable Edition of Sect on XI Utilized for Repairs or Replacements 19 80 with Addenda thru Winter 1981 and i Code Case N-308.
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Y9er
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) (P.O. Or) (Stock Code) (Heat #1 2"-600#WN FLG P.O. 8031-F
- 1) SA-182 GR.F316 80616 D2537 N/A ECC-117-l-1 N/A Replacement No
- 2) 4"x2"ConeRedh473066811-1 SA-403 CR.WP304 JNH1+
N/A ECC-117-1-2 N/A Replacement No l 4"L.R. Elbow 730 M -2 3) SA-403 GR.WP30 JPXB N/A ECC-117-1-3 N/A Replacement No I h473067893-2 HN042 N/A ECC-117-1-4 N/A Replacement No ~
- 4) g_
- 5) 4"-600#WN FLG P473067893-2 HN042 N/A ECC-117-1-5 N/A Replacement No SA-182 GR.F316
+ 804804-2 is also stamped in the component.
- 7. Description ot work Add bypass piping loop around Regenerative Heat Exchangers.
Hydrostatic Pneumatic 0 Nominst Operating Pressure O.p
- 8. Tests Conducted:
82 Other Pressure 195U
- p,3 7,,, ye,n,,
- Min, required. test pressure = 1.1 x 1290 (design pressure) = 1419 psig.
NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-l tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obte ned from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 1
o 4 - FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Co. (PECo) June 24,.1986 o,,e g, %ne, 2301 Market Street Nerae 2 3 l Philadelphia, PA 19101-sheet i-Aeo,. One (1) Limerick Generating Station
- uni, l
3, pi n, N * 'a* Evergreen Road Pottstown, PA 19464 PEco Mod 964 Ac cross Repak Organia stion P.o. No., Jot, No., etc. " ' ~ ~ N/A Philadelphia Electric Co. Type code symooi stamp . 3. Work Perforrned by Construction Division N*** Authorization No. WA Limerick Section Expiration Date Pot tstown, PA 19464aar== Reactor Water Cleanup System (44)
- 0. Identification ot system N/A.
74 go;,;on, Winter' 74 aga,ne,,
- 5. (a) Applicable Construction Code ASME,III 39 code ca e (b) Applicable Edition of Section XI Utitued for Repairs or Replacements 19 80 with Addenda thru Winter,1981 and Code Case N-308.
- 6. Identification of Components Repaired or Replaced and Replacement Components
.ASME Code National Repaired. Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built of Replacement or Noi (S(P.O. Ori )(Heat f) tock Code P471065923-J M3587 N/A ECC-117-1-6 N/A Replacemer,t No - 6) SA3h,TP304 4"L.R. Elbow P473060917-2 JPXB N/A ECC-117-1-7 N/A Replacemertt No 7) SA-403,GR WP3C4 P471060923-2 M3587 N/A ECC-117-1-8 N/A Replacemer.t No 8) j p g EID " P473060917-2 JPXB N/A ECC-117-1-9 N/A Replacemer t No 9) g 3 pep 471060923-2 M3587 N/A ECC-117-1-10 N/A Replacemer t No i 10) b 304 11) 4" .Eb 473060917-2 JSAS N/A ECC-117-1-1. N/A Feplacener t No ^
- E * ***
12) A ~~ A R 13) P471060923-{09233 N/A lECC-117-1-13 N/A Replacemerit No i 8C 8 pe ,3 14) j "[P S 09233 N/A ECC-117-1-12 N/A Replacemer t No P471060923-: I 15) P473063083-: BBS N/A ECC-117-1-l' N/A Replacemer t No F 'g P4J1060923-2 M3587 N/A ECC-117-1-10 N/A Replacement No 16)., p '473060917-2 JSAS N/A ECC-117-1-l' N/A Replacement No 17) S 43, 04
e '1 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI t, %nerPhiladelphia Electric Co. (PECo) Deti June 24, 1986 2301 Market Street 3 3 Philadelphia, PA 19101 g3,,, Aeor One (1) Limerick Generatine Station
- uni,
- 2. Plon, Ne'r*
Evergreen Road Pottstown, PA 19464 PEco Mod 964 Accrees Repelr Creenleetion P.O. No., Job No., etc. N/A Philadelphia Electric Co. Type Code syrnbot stamp
- 3. Work Performed by Construction Division Name N/A Authorization No.
N/A . Limerick Section Empiretion Dete Pottstown, PA 19464 Addrea Reactor Water Cleanup System (44)
- 4. Identification ot system 74 Winter '74 N/A ASME,III 39 Edition Addende_
% g,,,
- 6. (a) Applicable Construction Code 80 with Addenda thru Winter 1981 and (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19
~ Code Case N-308.
- 6. Identification of Components Repelred or Replaced and Replacemerit Components ASME Code National
- Repaired, stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Bullt or Repiscement or Nol (P.O. Or) (Stock Code) (Heat #) 18) 4"-600# WN FLG SA-182,GR.F316 P473067893- ! HN042 N/A ECC-117-1-1E N/A Replacemen : No 4"-600# WN FLG 19) SA-182,GR.F316 P473067893-2 HN042 N/A ECC-117-1-15 N/A Replacemen : No 20) ' _4b G L JSAS N/A ECC-117-1-2C N/A Replacemen : No g 1 0',P473060917-2 21) 4" S.R. Elbow S031-F SA-403,GR.WP30 80616 OKZ4LH N/A ECC-il7-1-21 N/A Replacemen-: No 4"x2" Conc. Red 22) SA-403,GR.WP30 LP473066811-1 JNH1+ N/A ECC-117-1-22 N/A P.eplacemen : No 2"-600vWN FLG 8031-F-D2537 N/A ECC-117-1-23 N/A leplacemen : No 23) SA-182,GR.F316 R0616 24) 7/8"x5-1/2" Studs Y530760021-2 KG21 N/A M1, M2 N/A Replacemen : No SA-193.GR.B7 7/8" Nuts Y531060005-1 25) q_1o4 cn ou Y3 N/A M1, M_2 N/A leplacemen : No 26) 1"-150p#p' lobe Borg Warner Valve N C1.1 65876 N/A Tag #44-1076 1981 leplacemen : Yes SA-182,GR.F316L j - ) followir g a steck code number indica :es the AS'T NOTE: The dash number (- I l Class i1, 2 or 3). t {
- sr FORM Nis.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. owner Philadelphia' Electric Company oste October 15, 1984 Name 2301 Market Street. Philadelphia,Pa.19101 Sheet 1 1
of Address
- 2. Plant Limerick Generating Station Unit I
Name P.O. Box A.Sanatoga Branch.Pottstown.Pa. Bechtel Job #8031 Ad dres* 1946.4 R*** oroenization P.O. No., Job No., etc.
- 3. Work Perfermed by Bechtel Construction. Inc.
Type Code Symbol Stamp Not Applicable N' '"* Authorization No. Not Applicable 50 Benie Street. San Francisco. Ca. Expiration Date Not Applicable Addrose 4, Identification of System Standby Liould Control 53A
- Edition, Addenda.1606. N-308 Code Caes
- 5. (a) Applicable Construction Code 19 *
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 81
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components l
ASME l .P Code-National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) Piping System Bechtel SP-HCB-130-Replace-l HCB-130 Constr.Inc. N/A N/A F3 N/A ment No . Piping System Bechtel SP-HCB-130-Replace-HCB-130 Constr.Inc. N/A N/A F4 N/A ment No
- 7. Description of work Added LT-lN010A.B.E & F to tank 10T-204 1
- 8. Tests Conducted: Hydrostatic C Pneumatic Nominal Operating Pressure O Other Pressure 6.6 pri Test Temp.__74 ap I
NOTE: Supplemental sheets in form of Ilsts, sketches. or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa, tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet la numbered and the number of sheets is f recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 w
\\ e I FORM NIS.2 (Back) Nozzles and piping were added to tank per ASME Section XI repair plan
- 9. Remarks Applicable Manufacturer's osta Reports to be ettsched -
8031-FM-34 l l 1 CERTIFICATE OF COMPLlANCE We certify that the statements made in the taport are correct and this Replacement conforms to the rules of the repair or repiecernent ASME Code, Section XI. Not Applicable Type Code Symbol Stamp Certificate of Aut or'zation No. Not Anolicable Expiration Date Not fuelicable .C.I. Proiect Construction Date M 8I ( ' 19 - Signed owner or owner s o.onse, Tine I l CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State The 11artford Steam Boiler Inspection & og or Province of Pennsylvania and employed by hev cted thbEhEtIdb8 Ekfibed Eartford. Conn. d' , and stats that I* [~ M Y to in this Owner's Report during the period l to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describad'in this Owner's Report in accordance with the requirements cf the ASME Code, Section XI. By signing this certificaw neither the inspector nor his employer makes any warranty, expressed or implied, concerning tne l examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. f ! AMc [/ Commissions inspector's Signature National Board, State, Province, and Endorsernents M __ Date __ / 19 / 02/82) 'q q
t.' v' ' t !w.{V.,'. '{_ ^ 1 7, v. s + .4L i
- u r
y. FORM NIS.2t)WNER'S REPORT FOR REPAIRS OR REPLACEMENTS, As Required by the Provisions of the ASME Code Segion XI Philadelphia Electric' Company 10 /31/R ei ' onte 3, g n,, .Name 2301 Market, Philadelphia, PA 19101' sheet 1 2 of Address I 1 Limerick Generating Station unit
- 2. Plant Name Evergreen & Sanatoga Rds.
P.O. Box A MRF 8508078 m m __ Adareas Hopelt organization P.o. No., Job No., etc.
- '"""W"#
Philadelphia Electric Co. Type Code SymbolSt mp
- 3. Work Performed by 2301 Market, Philad 1phia, PA 19101 ^ Expiration Date Address System 48 Man @y @d Conml i
- 4. identification of System
- 5. (s) Applicable Construction Code 19
- Edition, Addenca-Code Case 80,W '81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Ccmponents ASME Code Nat o m
- r. a. i.v.
Stamr4 Name of Name of Manufacturer Board Other Year Replaced,' (Yes Component Manufacturer Serial No. No. ident;f!ct, tion Sulli or Replacement or Nol P/N1532-Parts Kit Conax 704 N/A 162-01 84 Replaced No P/N1532-rep. Lac e Parts Kit Conax 702 N/A 162-01 84 ment No i i Replaced explosive actuator parts of valve XV-048-lF001A
- 7. Description ot work
- 8. Tests Conducted: Hydrostatic Pneumatic O Nominal Operating Pressure @
Other C Pressure 1230 p,i 7est7emp, ambient p" l Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 In., (2) Informa. NOTE: tion in items 1 through 6 on this report is included on each sheet,and (3) each sheet is numbered and the number of sheets is l recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 s. . ~,..._.-_-....._.-. g n.
g---- .j;p:g
- f.
3.,,r.z g.;, s'
- ~
r e 3 l Q @i'T;.; b* G L I T c', 9 'A +;,. i ' lye. + -l a. ,f . s f,,,.. s ,.: z' i + 1
- n.
+ c' s ,s.. .p- .4ni. .;j,, v FORM NIS 2 (Back) Replac'ed valve parts kit s/n.704' was not defective
- 9. Remarks Appilceble Manuf aqurer's Date Report 4 to be ettechop
- it operated as exp.ected. Replacement kit 702 is part' of saine Conax 1ot (No. 22-1) ahd G.E. purchase orderl20583L4 60) ~ as kit 704. The pressure test conducted includeh Eh'e valve flange that was disassembled to replace the valve parts. CERTIFICATE OF COMPLIANCE ~ BCeme We certify that the statements made in the report are correct and this nforms to the rules of the repair or repiecernent ASME Code, Section XI, N/A Type Code Symbol Stamp N/A Certificate f theorization N Expiration Date ~ Date. I 19 a J' s;gned Owner or owners Designee. Titie" %./ / '. -l CERTIFICATE OF INSERVICE INSPECTION '1, the undersigne holding a valid commission issued by the National Board of, Boiler and Pressure VessefInspectors and the State or Province of Mt 8%2 'M and employed by #M N N[ b of ek%M&M k/ nu r[Onf have inspected the components described. . In this OwpN's Report during the period ' Nd* ' # MU ~ ~ to.
- t 4't 8 MM ar.d state that
/ // to the best of my knowledge and belief, the Owner has performed examinati6n/s and taken; corrective measures described in this l ' Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector not his employer makes any warranty, expressed or implied, concerning the examinations and corrective rnessures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for ersy personal injury or property damage or e loss of any kind arising from or connected with this Inspection.
- tu.
-r d2-- Commissions National Board, State, Province, and Endorsements / inspectora Signature Date WM 19 + // ri s (12/B2) / . Sheet 2 of 2 1 1 'S A Qh. b +f et I \\ l l l .4 ~~ -- o. _ i j ,,...... ~. -.., g.,..... ____u_n______
-an _.. _,a. .m. ,_y., l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Coda Cection XI September 23, 1987 Philadelphia Electric Company g,1, l
- 1. owne, Name 2301 Market Street, Philadelphia, PA 19101 l
Sheet of Ac cross One Li.1erick Generating Station uni, __ l
- 2. Plant P.O. Box A Name Sanatoga Branch, Pottstown, PA 19464 PECo - Bechtel Job #8031 Address Repair Orgenlaation P.O. No., Job No., etc.
N/A PECo Construction Type code Symbo: Stamp
- 3. Work Performed by NA Name Authorization No, 2301 Market Street, Philadelphia, PA 19101 N/A Expiration oate Ad dress RCIC System #49
- 4. Identification of System 1516-1 code Case
- 5. (a) Applicable Construction Code ASME III 3g 74 Edition, Winter 1974 Addenda, 80 1567, 1622, 1682 (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
P!n. Identification Built or Replacement or No) c viobe valve Anchor HV-49-1F022 Darling E6179-3-f, N/A N/A 1978 Teplacemen: Yes i i Re m e vahe, tota g va M _ @ o ad reinstan. h d Gnve M on [
- 7. Description of Work U1Sc and helnstall4 NOG J U-+ U.
5Idl
- 8. Tests Conducted: Hydrostatic @ Pneuma Nominal Operating Pressure O t
60 ep Other O Pressure psi Test Temp. N u tel2elA7 pJL "fWO Supplemental sheets in form of lists, sketches, or drawings rney be used, provided (1) cize is 8% in. x 11 in., (2) Informa-NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. l i (12/B2) This Form (E00030) may be obtained from the Order Dept., ASME,345 E,47th St., New York, N.Y.10017 l I _ - - - - - - -. _. _ - - _ _ - _ _ - _ _ _ _ _ _ ---_+
-m FORM NIS-2 (Back)
- 9. Remarks __
Aopilcacie Manuf acturer's Data Reports to be attacned T CERTIFICATE OF COMPLIANCEreplacemenkonforms to the rules of the We certify that the statements mace M the eport are correct and this "P
- i' 0 ' '*p '
- c '*' n '
ASME Code, Section XI. N/A Type Code Symbol Stamp N/A N/A Expiration Date Certificate of Authorization No, 19 V' Date Signed 4 Q " Owner or Owner's Designes, Title CERTIFICATE OF INSERVICE INSPECTION f 1, the undersigned holding a valid commission issued by the National Board of Boiler and PrLsure Vessui inspecto i b"M*'AS d - of dI N#
- UP 8M and employed by or Provin e of _
4 A N/ /># _have inspected the compor.enis cascribed f/ U _ and state that D to _ in this Owner's Report during the period _ to the best of my knowiec;e and belief, the Owner has performed examinations and taken correcti.9 measures described in Owner's Report in accorcance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concer examinations and corrective measures described in this Owner's Report. Furtherrnore, neither the inspector nor his emplo shall be liable in any manner for any personal injury or property osmage or a foss of any kind arising frorp or connecte j l inspection. SW ze Commissions '/ National Board, State, Province and Endorsements 1,rspector's Sig re 7 7 Date /M /48 19 / l 02/82) -e <%.m 1
.2 vi FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1, Owner Philadel'bhia Electric Company oete April 10, 1985 Name 2301 Market Street, Philadelphia,Pa.19101 Sheet 1 of 2 Address
- 2. Plert Limerick Generating Station Unit I
Name P.O. Box A.Sanatoga Branch Pottstown.Pa. Bechtel Job #8031 A d dres' 19464 "*** C5*nization P.O. No., Job No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol Stamp Not Applicable Authorization No. Not Applicable 50 Beale Street. San Francisco. Ca. Expiration Date Not Applicable Addreas Reactor Core Isol'atien Cooline 50A
- 4. Identification of System Addende.N-316.1606 code Can 19
- Edition,
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Winter 81 N-?08
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components
[ ASME j ig
- Repaired, Stamped Code-l National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) Piping System SP-HBB-150-HBB-150 Rockwell ZA865 N/A El-1F028 1978 BRl*c*- Yes I l l [
- 7. Description of work nommro srm 1 sro nn RAtinh19n r? nnd in en11 new valve on SP-HBB-150-El
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other Pressure 66 psi Test Temp. N/A
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% In. x 11 in., (2) Informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form, s (12/82) This Form (E00030) may be obtained from the Order Oopt., ASME,345 E. 47th St., New York, N.Y.10017 6
o N FORM NIS 2 (Back).
- 9. Remarks Replacetnent was Derfomed and comnleted ner ASME Rection YT ren1ncomont
. Appuceble Manufacturer's Data Reports to be attached n1 nn R O '41 -FM-5 7. Rev. O A Rev. 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thi.Ren1 ncompne conforms to the rules of the '*D*D*D'*****"* ASME Code, Section XI. Nne Inn 14cnh10 Type Code Symbol Stamp Mne Am14enh1c Expiration Date Noe ael4cahla Certificate of Authorization No. MM 19 _N ET-P"n4ae* F" * *m e
- 4 m Date Sign
' owner or owner's Designee, Title [ CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of P a""yl VA 4 a and employed by %p MnvefnrA ArAmm Rn41er Tnnnoce4e & of Hartford. Conn. have inspected th M M [d h fbed A/54 / b ' E /S8 ! b to - and state that in this Owner's Report during the period i / r i to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. W> h-v Commissions U# AI inspeciprs Signature National Boerc, State, Province, and Endorsements 8d M 19 Date / 112/82) J r
.' s yy FORM NIS.2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Ph41ndelnhin Tlectric comoany Date April 10. 1985 Name 2301 Mnrket Street. Philadelphia.Pa.19101 Sheet 2 of 2
Adorses
- 8. Plant i imar4 cle Conerneine Reneinn Unit T Nomi P_0 Rnv A.
Ennntoca Branch.Pottstown.Pa. Rechtel.Tob #8031 " " * ' ' '8*nisation P.o. No., Job No., etc. Ado'" 19464
- 3. Work Performed by Rachtel ennstruction. Tnc.
Type Code Symbol Stamp No t Aeolicable Authorization No, Not Aeolicable 90 Ronlo Arrone. Mnn Frnncisen. Cn. Empiration Date Not Aeolicable Adorses 4, identification of System Roncent Enre Tan 1nrinn cooline SOA Addenda: N-316.1606 Code Case 19
- Edit' ion,
- 6. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Winter 81 N-308
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stemped Name of Nome of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) Piping System Ht. No. SP-HBB-150' Replace-MRR-190 U.R. Reeel T 00049 N/A -E2-Pc.44 N/A ment No Piping System Capitol Ht. No. SP-HBB-150 Replace-MRR-150 Mfy. Co. 0845 N/A -E2-Pc.45 N/A ment No Piping System Capitol Ht. No. SP-HBB-150-Replace-MRR-iso Mfe. co. 0845 N/A -E2-Pc.46 N/A ment No
- 7. Description of Work Ran1nce remnved valve tJith eine and couplinRs B. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 OtherC Pressure 10 psi Test Temp.
N/A
- F NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) Informs.
I tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is j recorded et the top of this form. N (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 -o. n {
FORM NIS 2 (Back) Replacement was nerformed'and comnleted ner ASMF Seceinn YT renlmrompwr
- 9. Romerks Aoplicable Manufacturer's Date Rooorts to be ettsched n1nn R O"11 -FM-5 7 - Rev. O
- t. Rev. 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thi.Ren1 nc amont conforms to the rules of the
.ASME Code, Section Xl. Mne Ann 14enh1a Type Code Symbol Stamp App! d a nM a Expiration Date Mne Anp14cnh1o We certificate of AuthgrListion No. M M, _1g bI LWF T Pen 4pne ennerviine4mn Date Signe 1 ' Owner _or owner's Designee. Title / Mgr. CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State The Hartford Steam Boiler Inspection & of or Province of Pennevivnnia and employed by have inspected the MENdhlbed heefnvA ennn-in this Owner's Report during the period d /^,# M and state that to to the best of my knowledge end belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this cr:rtificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations end corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer l shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from of connected with this it*spection. We U Commissions 'A ! A 4N insopctor's signet e National Board, State, Province, and Endorsernents Y/S k 19 c Date j / I J (12/82) t J y ..___m 1
l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Comoany Date Aucust 16. 1985 Nome 2301 Market Street. Philadelphia.Pa.19101 Shut 1 of 1 Address
- 2. Plant 1imerick Generatino Station Unit 1 Nerne P.O.Bov A.Sanatoca Branch.Pottstown.Pa.
Bechtel Job #8031 Repair Orsentration P.O. No., Jot No., etc. Ad dr " 19464
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol Stamp Not Applicable Authorization No. Not Apolicable 5 50 Benie Street. San Francisco. Ca. Expiration Date Not Applicable .l Address 4 Identification of System Ronerne enrp Tc:olnrion Ccoling 50A 19 E dition,. Addenda, N-316.1606 Code Case I
- 5. (a) Applicable Construction Code l
(b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 81 N-308 l
- See Spec. 8031-P360, Rev.9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Bullt or Replacement or No) Piping System P.O. Ebb-133 Replace-l FRR-ill Front Fngr. F-74520 N/A FO-ID006A N/A ment-No Piping System P.O. Replace-Engilv7Aun N/A FO-1D006B' N/A ment No l FRR-ill Front I
- 7. Description of Work Renlace flow orifices on EBB-133-1 j
- 8. Tests Conducted: Hydrostatic Prieumatic 0 Nominal Operating Pressure O Other O Pressure 1656 psi Test Temp.
75
- p NOTE: Supplemental shsets in form of lists, sketches, or drawings rney be used, provided (1) size is 8% in.x 11 in., (2) Informa-tion in items 1 through 6 on thir. report is included on each sheet, and (3) each sheet is numbered and the number of sheets la recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 -o. 8
FORM NIS 2 (Back) Replacement was performed and completed per ASME Section XI replacement
- 9. Remarks Appliceb!s Manufacturer's Data Reports to be attached plan 8031-FM-53 CERTIFICATE OF COMPLlANCE Replacementconforms to the rules of the We certify that the statements made in the report are correct and thisP
- i' "' P ' 'c '* * "'
ASME Code, Section Xl. Not Applicable Type Code Symbol Stamp Certificate of Au orization No. Not Applicable Expiration Date Not Applicable MMM ,18[ B.C.I. Proiect Construction oate Signed DwneYor owner s Designes, Title gy, [ CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State The Hartford Steam Boiler Inspection & og or Province of Pennsylvania and employed bv brefnrd rnnn have insoected t NMNs hsdribed b Y' N E*d" . and state that to in this Owner's Fieport during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. h ef@/ [ u::.
- 4 Commissions
/ Inspector's Signoture Netional Board, State, Province. and Endorsements Date / 19 TA f j U2/82) ~o. (
1 FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner. Ph41nAalnh4n Flacevic Ennnnnv Date Sectember 28. 1984 Name 2 01 W rtr o r Revooe.ph41mdp1nhin_Pn.14101 Sheet ___l of 1 Address
- 2. Plant Timprick Generating Station Unit T
Name P.O. Boy A. Snnatogn Branch. Pot tstoten.Pa. Bechtel Job #8031 Repelr reonizati n P.O. No., Joo No., etc. < Ac or" 19464
- 3. Work Perfornwd byJacheel Construction. Inc.
Type Code Symbol Stamp Not Applicable Authorization No. Not Applicable 90 Ron1a cevope Ann Francinco. Ca. Expiration Date Not Applicable Address
- 4. Identification of System po e 4 dital W ne Romnvn1 49A N/A
- 5. (a) Applicable Construction Code ASME VIII 1g68
- Edition, N/A
- Addenda, Code Case (b) Appliceble Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 81
- 6. Identification of Components Repeired or Replaced and Replacement Components
[Ih ASME )b4 Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Repiced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) R.H.R. Heat Delta vya,ne.v Southern Co 35002-72 3114 2BE-205 1972 Repair Yes ~ -2 I
- 7. Description of VVork perfnvm upl A renair to nozzles N1 & N2 on RHR Heat Exchanger 2BE-205
{ l
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure Other Pressure M/A psi Test Temp. N/A
'F i NOTE: Supplemental sheets in f arm of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (21 informs. tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form -(E000301 may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 ~e. l _m
4 FORM NIS 2 (Back) ReDair was performed and comoleted per ASME Section XI repair plan i
- 9. Remarks Applicable Manufacturer's Data Reoorts 'o be attached RM 1 -FM-18 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this. Reoair conforms to the rules of the
'**** 'epiecensent ASME Code, Section XI, Type Code Symbol Stamp Nne Aeolienble Certificate of Aut ization No. Not Ann 1ienh1e Expiration Date Not Annlicable Signed, Construction Date [D d 19 E.C.T. Proiect e Owner or Owner's Des #gnee Title Mgr. [ CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspecore and the State The Hartford Steam Boiler InBDection 6 of or Province of Pennnylw nin and employed by have inspected the cN[nNth debOtIed i l U n v e f nyr1. Onnn-W / /- to . and state that in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed ex6minations ano taken correctivs measures described in this l Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. P 7 LL It t_ 6 Commissions - National Board, State Province, and Endorsements InspecA r*s Signature Y Date 19 / (12/82) J l l t
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philnefelnhin Flectric Comoany cate Aoril 17. 1985 Nerne 2301 Market Street. Philadelphia.Pa.19101 Sheet 1 of 1
Accross
- 2. Plant Ti w rick Conerneine Rention Unit T
Name' P.O.Env A.Rnnntoca Ernnch.Pottstown.Pa. Rochen1.Tnh #8031 - Aodress Repelr Organization P.O. No., Job No., etc.
- 3. Work Performed by Recheel Cnn c:t rtic e i nn. Tnc.
Type Code Symbol Stamp Not Annlicable Authorization No. Not Aeolicable 50 Ronle Reveet Enn Frnneinen. Cn. Expiration Date Not Aonlicable Accrees
- 4. Identification of System RaciAnn1 ITon e Rememn1 4QA N-226 N-252
- 5. (a) Applicable Construction Code 19 *
- Edition, Addenda, N-116.1606 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 RO Minter 81 N-308 N-237-1 See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Compor ents l
ASME Code National
- Repaired, Stampea i
Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replaceraent or No) Piping System Southwest CER-118 Fnbr. & 1821 N/A GBB-118-4 1973 Repair Yes Weld. Co. -6 l 1 l
- 7. Description of Work Rennir nrea of oice that revealed indications per GBB-118-4
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure N/A psi Test Temp. N/A
- p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa.
tion in items 1 through 6 on this report is included on each sheet, and (3) each shfMat is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 .. e n
FORM NIS 2 (Back)
- 9. Remarks lenair 1. as nerfomed nnd complored per ARMF Anceinn YT rpnnir nlan NA-R5-001 Applicable Manufacturer's Date Mooorts to be ottsched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this. RPPAir conforms to the rules of the ASME Code, Section Xl.
NnP Ann 1ieahla Type Code Symbol Stamp Certificate of Au orization No. We A"n14enkla Expiration Date Nm" A""14 ahl a OO -,19 FT-Dmia"* En"cP""""in" Date Signe g [ = ' owner or owner's Desiones. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valirl commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Pae ev1"n"4n end omployed by ha Mar
- ford Cramm Rn 41 er Tnepperion & of have inspected the gge bibed l
MnvefkvA %n do 3"b -TI @ 2 / ~ 8- . and state that to in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owrier's Report. Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. N. Commissions - A@AWf National Boero, state, Province, and Endorsements y inspect 's signature 3 /A3 19 Date 02/82) l L t l -e. I k f ..,.m.-.a
i l i 1y l l FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS i As Required by the Provisions of the ASME Code Section XI i
- 9. Owner Philadelphia Electric Comnany oate
%v 9. 1985 N ms 2301 Market Street. Philadelphia.Pa.19101 Sheet I of I t Address l
- 3. Plant T4mariek Generatine Station Unit I
Nem. P.O. Box A.Sanatoca Branch.Pottstown.Pa. Bechtel Job #8031 Ad d'" 19464 "*** 0*nisetion P.O. No., Job No., etc.
- 3. Work Performed by Rechtel Construction. Inc.
Type Code SymbolStamp Not Applicable Authorization No. Not Applicable 50 Renie Street. San Francisco. Ca. Expiration Date Not Applicable Ad dress
- 4. Identification of System Reci rin n1 Heat Removal 16A Addenda.N-316.1606 Code Case 19 *
- Edition,
- 5. (a) Applicable Construction Code, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 160 Winter 81 N-308
- See Spec. 8031-P360, Rev. 9 l
- 6. Identification of Components Repaired or Replaced and Replacement Components 1 )
ASME Code National
- Repaired, Stamped f
Nome of Name of Manufacturer Board Other Year ' Replaced. (Yes Component Manufacturer Serial No. No. Identification Built or Replacemeret or No) i Piping System Bechtel Replace-MRc-508 constr.co. N/A N/A HBC-508-H4 N/A ment No l Piping System Bechtel Replace-WRc-508 constr.co. N/A N/A HBC-508-H5 N/A ment No Piping System Bechtel Replace-nRr-500 conner.co. N/A N/A HBC-509-H4 N/A ment No l' Piping System Bechtel Replace- , No unc-509 constr.co. N/A N/A HBC-509-H6 N/A ment i l
- 7. Description of work Renlace shims on hancers l
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other] Pressure N/A psl Test Temp. N/A
- F NOTE: Supplemental sheets in form of lists, sketches, or drewings may be used, provided (1) size is 84 in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is 8
recorded at the top of this form. s ,,,, 12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 ( ________________________~JXT~~
k l t i ) FORM NIS 2 (Back)
- 9. Remarks Replacement tan ct nerformed nnd comnleted ner ARMF Rectinn YT ren1Meement Applicable Manutecturer's Date Reports to be attached n1nn RO11-TM-67 CERTIFICATE OF COMPLIANCE We certifV that the statements made in the report are correct and this Een1 Ac emSILL conforms to the rules of the repair or roolecement ASME Code, Section XI.
Type Code Symbol Stamp Mne Ann 14enh1p Mnr Ann 14enh1a Expiration Date he Ann 14enh1o Certificate of Authyri stion No. f Signed ET-Pen 4per emn e r ru e r i nn Date N M ~ 19 Owner or owner's Designee, Titie " f CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Penncylvnnin end omployed by Th n MnvefnrA-C:Ponm Rn41pv Tnenoce4nn A of Mnerfned-Innn-have inspected the MMM[rTseshebed in this Owner's Report during the period S/Y/9I /EE' and state that to i / i to the best of my knowledge and belief, the Owner has performed examinations and taken correctie measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and correct we measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind erlsing from or connected with this inspection.
- )
i 9 / U '! A #I W Y l. Commissions tc Nationel Soard, State, Province, and E endorsements t nspector's SignaturyJ /! [ 19 Date H2/B2) .) ,w____
i i I e l NIS-2# 86-03 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI i
- 1. Owner Philadelphia Electric Comoany Date Aucust 6. 1986 Name 2301 Market St., Philadelphia, PA. 19101 I
I Sheet of Acoren
- 3. Plant Limerick Generating Strtion I
Unit Name P.O. Box A. Sanatoga Branch, Pottstown, PA.19464 Bechtel Job # 8031 Ad oress Repair Orgen12stion P.O. No., JoD No., etc. ~
- 3. Work Performed by Bechtel Construction, Inc.
Type Code Symbol Stamp Not Applicable Narne Not Applicable Authorization No. 50 Beale Street, San Francisco, CA. Expiration Date Not Applicable Ad dress
- 4. Identification of System Residual Heat Removal System-Loco "A" and Loop "B" Wetwell Spray Ring Headers.
P.&I.D. 8031-M-51, Sht. 1&2 and Design Spec. 8031-M-551 1606
- 5. (a) Applicable Construction Coce 19
- Edition, Addenda.
c,,, e,,, (b) Applicaule Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 1981
- See Spec. 8031-P-360 Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped 1
Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement or No) l 6"-300# WN Taylor Piping Sys. I Sch. 40, RF, Flo Force GBC-ll2 N/A HT# GCUW N/A Replacement No i SA 105 (4 Pes) Spectacle Colonial Piping Sys. Blind, SA515, Machine Co. GBC-112 N/A HT. Code PAP N/A Replacement No GR 70 (2Pcs)
- 7. Description of Work Installed two sets of 6" flanges with spectacle blinds and modified test connections on wetwell spray ring header inlet piping, piping system GBC-ll2.
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nominal Operating Pressure C Other @ Pressure N/A psi Test Temp.
N/A
- p Flow test to demonstrate unimpaired flow thru spray headers.
, sNtc,Nr hw~ingsNyQg5kdhh N she is 8% in. x M in., (2) Informa-NOTE: Supplemental sheets in form o : tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of bois form. (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 a i i
_= - - _ _ _ _ __. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ i f o ) l ) i I l 1 1 1 FORM NIS 2 (Back)
- 9. Remarks This is a modification of wetwell $ Dray rina headPr inlet DiDina in accordance with Applicaole Manuf acturer's Data Reports to be attached MDCP# 0193. Reference WP# 49A-013, PSCL# 49A-7022, and repair / replacement plan # 86-03.
CERTIFICATE OF COMPLIANCE e acement l We certify that the statements made in the report are correct and this conf orms to the rules of the i reasir or repiecernent ASME Code, Section XI. Not Applicable Type Cooe Symbol Stamp Not Applicable Not Applicable Expiration Date Certificate of Authorization No, N~!b ~ Owner or Owner's Designes, Title ' 19 Signed Date i i CERTIFICATE OF INSERVICE INSPECTION t, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State 8 er Noe@ nam MWam D Pennsylvania and employed byJa bf or Province of l l Hartford Connecticut have inspected the components described //,//I /N / N,/ b . and state that in this owner's Report during the period to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. f' By signmg this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this incect;on, f1 W-Commissions /4) 0 $ 76 .ns,1.,s.,,n.,ug ~., ion........ st.se.,.,ovin....no enoo,,e,n.n,s E!/ 19 Date / (12/82)
_ y-_ 9' 1 FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelpi.ia Electric Company August 20, 1987
- 1. owner g,,,
Navne 2301 Market St., Phila., PA 19101 Sheet of Aodrosa ~
- 8. Plant Limerick lenerating Station One (1) unit P.O. Box A N=
Sanatoga Branch, Pottstown, PA PECo - Mod 24 Ad dress Repelr Organization P.o. No., J0D No., etc. N/A
- 3. Work Performed by Philadelphia Electric Co.
Type Code Symbot Stamp N*" N/A Authorization No. 2301 Market St., Phila., PA 19101 Expiration oste N/A Ad dress
- 4. Identification of System Residual Heat Removal, Specification 8031-M-551,,,
a8 a-v, a u, N-316,N-71-9
- 5. (a) Applicable Construction Code 19
- Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 - Winter 81.
- Specification 8031-P-360, Rev. 9.
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Seriel No.
No. Identification Built or Replacement or No) h soy Steel / FO-51-120A ggl 29317 N/A Flow Orifice N/A Replacemer t No FO-51-121A 29317 N/A Flow Orifice N/A Replacemer;t No FO-51-120B 29317 N/A Flow Orifice N/A Replacemer,t No FO-51-121B 29317 N/A Flow Orifice N/A Replacemertt No WeSC Jersey i GBB-108-2-3 Mf g. Corp. 9772 N/A 18"W.N.Flg. N/A Replacemertt No j 8 E
- 7. Description of Work
- 8. Tests Conductad: Hydrostatic { Pneumatic Nominal Operating Pressure Other O Pressure psi Test Temp.
'F l i NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% In. x 11 in., (2) Informa-l tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 1 (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 l PSI F
- "A" - LOOP 540 57.5 l
"B" - LOOP 534 85 1
- av
) FORM NIS 2 (Back) am dd MM Seds U,. . 9, Remarks Applicable Manufacturer's Date Reports to be attached ' Specification 8031-G-33, MDCP-24 and. the Construction Job Memor'andum for. Mod 24. .j CERTIFICATE OF COMPLIANCE We certify that the statemfints made in the report are correct and thisreDlacement conforms to the rules of the N '*D'**** *"* ASME Code, Section XI. Type Code Symbol Stamp Certificat of Authorization o. Expiration Date Signed C b 4'L*# e U 19 t owner or owners Designee. Title 1 Q Q ' CERTIFICATE OF INSERVICE INSPECTION , I, the undersigned, holding a v lid commission issued by the N tionpl Boar of Boiler and Pressure Vessel inspectors and the State and empioves f y Add "3rbD'MOMN" N' or Province of 9EM of + MA4 A([ bM' have inspected the components described in this Owner's Report during the period /d/O //0/U . and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his errtployer shall be liable in any manner for any personal injury or property dama0e or a loss of any kind arising from or connected with this inspection. 'N Commissions &A *7E ~ y.o... ors 7.m,e ~.. ne....,o.... e.,romnc...no e nco,s. men,s I W 19 j Date (12/82) 1
FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company o,,, August 20, 1987
- 1. Owne, Name 2301 Market St., Phila., PA 19101 2
2 Sheet of Ad dress One (1) 1.imerick Generating Station unit
- 3. Plant P.O. Box A Nam
- Sanatoga Branch, Pottstown FA PECo - Mod 24 Address Repelr Organization P.o. No..JcD No etc.
N/A Philadelphia Electric Co. Type Code Symbol Stamp
- 3. Work Performed by N/A 2301 Market St., Phila.," S* 19101
~ Auth rizati n No. N/A Expiration Date + Address Residual Heat Removal, Specification 8031-M-551
- 4. Identification of System N-240, N-241, N-308 nter b: N-316,N-71 code ca
- 5. (a) Applicable Construction Code
'19
- Edition, Adden (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- See Specification 8031-7-760, Rev. 9.
- 6. Identification of Components Repaired or Replaced and Replacement Components 2
ASME Code National
- Receired, Stemped Name of Name of Manufacturer Board Other Yeer Reptoceci, (Yes Component Manufacturer Seriel No, No.
Identification Built or Replacement or Nol nesc sevsey GBB-108-2-4 Mfg. Corp. 9772 N/A 18"W.N. Flg. N/A Replacemette No CBB-108-2-5 9772 N/A 18"W.N. Fig. N/A Replacemettt No GBB-108-2-6 9772 N/A 18"W.N. Fig. N/A Replacement No GBB-108-1-4 Piping Supply 1753 N/A 18"W.N. Fig. N/A Replacement No GBB-108-1-5 Piping Supply 1753 N/A 18"W.N. Fig. N/A Replacement No West Jersey GBB-108-1-6 Mfg. Corp. 9772 N/A 18"W.N. Flg. N/A Replacement No l GBB-108-1-7 9772 N/A 18"W.N. Fig. N/A Replacement No I t b_ __
r 7 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI October 15, 1984
- s. Owner Philadelphia Electric Company Oete Name 2301 Market Street. Philadelphia.Pa.19101 Sheet 1
of 1 Address
- 3. Plant Limerick Generatine Station Unit -
I Name P.O. Box A.Sanatona Branch.Pottstown.Pa. Bechtel Job #8031 Ad dr" 19464 Repair Organimlon P.O. No., Job No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol Stomp Not Applicable Authorization No. Not Applicable Name 50 Renle Street. San Francisco. Ca. Expiretion Date Not Applicable Address
- 4. Identification of System Enre Entnv 51A N-274 N-316
- 5. (a) Applicable Construction Code 19
- Edition, Addende,N-308. 1606 Code Case (b) Applicable Edition of Section XI Utilized for Repeirs or Replacements 1980 Winter 81
+ See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Repieced end Replacement Components ASME Code National
- Repaired, Stemped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No, Identification Built or Replacement or No) Piping System Southwest 2038 GBB-112 Fabr. & (GBB-112-N/A FSK-GBB-112 1971 Repair Yes Weld. Co. 2-1) FWX61R1 Sht. 3 of 3 Piping System Alloy Fit-Et.#425919 GBB-112 eines Co. (GBB-112-N/A FSK-GBB-112 N/A Repair Yes 2-10) FWX61R1 Rht. 3 of 3
- 7. Description of Work Renair weld area of pipe that violates minimum wall thickness. per FSK-GBB-112-2 Sheet 3 of 3
- 8. Tests Conducted: Hydrostatic 0 Pneumatic Nondnel Operating Pressure Other Pressure N/A psi Test Temp. N/A
- F l
NOTE: Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) stre is 8% in. x 11 in., (2) Inforrne-tion in herr.s 1 through 6 on this report is included on each sheet, and -(3) each sheet is numbered and the number of sheets is recort.4 et the top of this form. 4 (12/82) This Form (E00030) may be obtained from it e Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 e. n a.
FORM NIS 2 (Back)
- 9. Remarks Ronni r tena nerfnt-ed nnd enmnieted ner ARMF Section XI reDair plan Applicable Manufacturer's Date Reports to be etteched 8031-FM-33 CERTIFICATE OF COMPLIANCE Repair conforms to the rules of the We certify that the statements made in the report are correct and this
'*P'"**P'***'"*"* ASME Code, Section Xl. Type Code Symbol Stamp Not ADDlicable Noe Annlicable Expiration Date Not Applicable Certificate of Auth r stion No, Signed Cons tructiorDate f O1 b I C T. Proiect 19 ' Dwner or owners Designee Titie g7, CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the Stats-or Province of PP W yIVA"in and employed by The Hartford Steam Boiler Inspection & Hartford. Conn. have insoected thN8n%Es' des?ribed to end state that in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken correctNe measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI, By signin0 this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector not his employer shall be lieble in any manrier for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. I M t '" Commissions inspectors ..no,u,e ~ et one ..e,... tete. er..nce. en. e noo,soments I N \\ Date 19 i l (12/82) l l l 1 I \\ l ) l l i _ _______________i
l 1 ) I FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Cotneany Oate October 15. 1984 meme 2301 Market Street. Philadelphia.Pa,19101 Snnt 1
of 1 Accrees
- 8. Plant Timerick Ceneratine Station Unit I
Nome P.O. Box A.Sanatoca Branch.Pottstown.Pa, Pechtel Job #8031 l gg4g4 Repok Organisecon EO No., Joo No., nc. Addrom
- 3. Work Performed by Rechtel Construction. Inc.
Type Code Symbol StampNot Aeolicable l Authorization No. Not Aeolicable l 50 Renie 9ereet. San Francisco. Cn. Expiration Oste Not Aeolicable Accross i G. Identification of System enre Enrnv 51A N-274,1606
- 5. (al Applicable Construction Code 19 *
- Edition, Addenda, N-308 N-316 Code case (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 1980 Winter 81
- See Spec. 8031-P360, Rev. 9
- 6. loentification of Components Reps, ired or Replaced and Replacement Components ASME I
,k Coce National
- Repaired, Stamped Name of Name of Manufacturer Doord Other Year F 'tplaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Restatement of No) Piping System Southwest 3501 CER-112 rnbr. r (CBB-112-N/A FSK-GBB-112 1971 Repair Yes a Weld. Co. 3-6) FWX55 Sht. 1 of 1
- 7. 04scription ot work Rennir veld area of eine that indicated lack of fusion per FSK-GBB-112-3 Sheet 1 of 1
- 8. Tests Conducted: Hydrostatic @ Pneumatic Nominal Operating Pressun C Other Pressure MR psi Test Temp.
EO 'F NOTE: Supplemental sheets in form of lists, sketches, or drawings mey be used, provided (1) size is 84 in. x 11 in., (2) informo-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtamed from the Order Ospt., ASME,345 E. 47th St., New York, N.Y.10017
FORM NIS-2 Cck)
- 9. Remarks 9etn4r uns nerformed nnd comnlered ner AEMF Section XI retnir ninn Applicable Manufacturer's Date Reports to be attached RO11 94.MO CERTIFICATE OF COMPLIANCE EeUnIY conforms to the rules of the We certify that the statements maos in the report are correct end this ASME Code,Section XI.
Mnr Ann 14enh1p Type Code Symbol Stamp Certificate of Aut rization No, Nne Anni 4enk1a Expiration Date Mnr Ann 14enh1p Signed Enn cry,t e r 4 nn Date - 2 19 Ch'R P T Pvn4aee ' ' Owner or Owner's Designes, Title CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Vanneyl m 4n and employed by % p UnvrfnvA Repnm En41er Tunection & of have inspected thb5MdMf dhs9rit,ad Mnveford Enn"- b to and state that in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the re6uirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor nis employer rnakes any warranty, expressed or implied, concerning the examinations anJ corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any.menner for any personal injury or property damage or a loss of gay kind arising from or connec;ed with this inspection. I W _ Commissions / inspector's signature Nationet soord, state, Province, and Endorsernents U 19 U Date / (12/E2) )
k FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI March 24, 1987 Philadelphia Electric Company Date
- 1. Owner Name I
2 l 2301 Market St., Philadelphia, PA 19101 Sheet o, Ad dr ess One (1) Limerick Cenerating Station unit
- 2. Plant P.O. Box A Name Sanatoga Branch, Pottstown, PA PECo - Mod 5019 Repair organization P.O. No., Joe No., etc.
Address Not Applicable Philadelphia Electric Co. Type Code Symbol Stamp
- 3. Work Performed by Not Applicable Na nie Authorization No.
Not Applicable 2301 Market St., Philadelphia, PA 19101 Exp;retion pete Ad dress Fuel Pool Cooling & Cleanup, Specification 8031-M-553 4 Identification of System N-240,N-241 Addenda, N-71-9.N-316bde case -
- 5. (a) Applicable Construction Code 19
- Edition, 80, Winter 81 N-308 (b) Applicable Edition of Section XI Utillred for Repairs or Replacements 19
- See Specification 8031-P-360, Revision 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement or No) 3 90 Ell HCC-106-2 Wilh.Schulz 84499 N/A lHCC-106-2-1 N/A Replacemer.t No Pipe Spool HCC-106-2 Dravo L-60639 N/A HCC-106-2-2 N/A Replacemer.t No iee HCC-106-2 Wilh.Schulz 84499 N/A HCC-106-2-3 N/A Replacemer t No ' Pipe Spool HCC-106-2 Dravo 819174 N/A HCC-106-2-4 N/A Replacemer.t No Pipe Spool HCC-106-2 Dravo L-60639 N/A HCC-106-2-5 N/A Replacemer,t No ReE ace portions of carbon steel RHR/FPCC intertie P ping with i l 7 Descr.iption of Work stainless steel.
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure @
Other Pressure . psi Test Temp. 'F Supplemental sheets in form or lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-NOTE: tion in stems 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the rumber of sheets is recorded at the top of this f orm. This Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017 o ,. J12/82)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI March 24, 1987 Philadelphia Electric Company g,,,
- 1. owner Name 2
2 2301 Market St., Philadelphia, PA 19101 gg,,, Ac cross One (1) Limerick Generating Station Unit
- 2. Plant Name P.O. Box A Sanatoga Branch, Pottstoten, PA PECo Mod 5019 Repair organization F.o. No., Job No., etc.
Address Not Applicable
- 3. Work Performed by Philadelphia Electric Co.
Type Code Symbol Stamp Not Applicable 2301 Market St., Philadelphia, PA 19101 ^"'h'"N-Not Apolicable Expiration Date Ad oress Fuel Pool Cooline and Cleanuo. Specification 8031-M-553
- 4. identification of System N-240,N-241 S. (a) Applicable Construction Code 19 Edition.
Addenda,N-71-9,N-316 code case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Winter 81 N-308
- See Specification 8031-P-360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
No. Identification Built or Replacement orNol 90 Ell HCC-106-2 Wilh.Schulz 84499 N/A HCC-106-2-6 N/A Replacemen : No Pipe Spool HCC-106-2 Dravo L-60639 N/A HCQ-106-2-7 N/A Replacemen : No 90~ Ell HCC-106-2 Wilh.Schult' 84499 N/A HCC-106-2-8 N/A Replacement No Pipe Spool HCC-106-2 Dravo L-C'E39 N/A HCC-10' ?-0 N/A Replacement No Fipe Sp >l HCC-106-2 Dravo L-60639 N/A HCC-106 2-10 N/A Replacement No Camco Halt Lougling HCC-106-2 Fittine, Co. DXI '.1/ A HCQ-106-2-1: N/A Replacement No 90' Ell HCC-106-2 Wilh.Schulz 84499 .1/A HCC-106 1 ? N/A. Replacement No Pipe Spool HCC-106-2 Dravo L-60639 N/A HCC-106-2-11 N/A Replacement No HCC-106-H9 PECo N/A N/A Pipe Suppor : N/A Replacemer t No HCC-106-H10 PECo N/A N/A Pipe Suppor : N/A Replacemer t No HCC-106-H11 PJCo N/A N/A Pipe Suppor : N/A Replacemer t No HCC-106-H12 PECo N/A N/A Pipe Suppor : N/A Replacemer t No HCC-106-H13 PEco N/A N/A Pipe Suppor t N/A Replacemer t No
a FORM NIS 2 (Back) Replacement was performed and completed in accordance with ASME
- 9. Remarks Applicable Manuf acturer's Data Reports to be attached Section XI, Specification 8031-G-33, MDCP 5019 and the Construction Job Memorandum for Mod 5019.
CERTIFICATE OF COMPLIANCEreplacemenkonforms to the ruIes of the We certify that the statements made in the report are correct and thisP'""PC'**"* ASME Code, Section Xl. Not Applicable Type Code Symbol Stamp Not Applicable Not Applicable Expiration Date Certificate of Authori28 tic. o. W fit h Date 19 Signed owner or owner's Des <gnes. Title I Q CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State ' d' I' T' O#- of or Provmee of de and employed by b dM-have inspected the components described N#f oc U" 7 " N 3~Z#*~97 . and state that to in this Owner's Report during the period to the best of my knowledge and belief, the Owner has performed examinations and taken corrective mear;res described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any persunal injury or property damage or a loss of any kind arising from or connected with this inspection. ~ ~ Insof/ tor's Signat e2 Commissions _ National Board, State. Province, and E noorseme.. 8 ~Ok 19-- Date (12/82) -o.
? FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
- 1. Owner Philadelphia Electric Company Date October 21, 1985 Name 2301 Market Street, Philadelphia, Pa.19101 Sheet 1 of 1 Address 2, Plant Limerick Generatiner Station Unit I
Nome P.O Box A.Sanatgga Branch,Pottstown.Pa Bechtel Job 98031 Rmtr Organization P.O. No., JoD No., etc. Addrm yg4g4
- 3. Work Performed by Bechtel Construction, Inc.
Type Code Symbol Stamp Not Applicable Authorization No. Not Applicable 50 Beale Street, San Francisco, Ca. Expiration Date Not Applicable Ad dre
- 4. Identification of System High Pressure Coolant Iniection 52A N-316,N-226,N-252
- Edition, Addenda, 1606, N-308 Code case
- 5. (a) Applicable Conuruction Code 19 *
(b) Applicaole Edition of Section XI Utilized for Repairs or Replacements 1980 Winter 81
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
.e National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identifice6cn Built or Replacement or No) Piping System Bechtel FO-lD010A Replace-EBB-129 Constr.Inc.FO-lD010B N/A EBB-129-2 N/A ment No HT ISSP
- 7. Description of Work Replace Flow Orifice FO-SS-lD010 & Spacer Plate Per FM-54
- 8. Tests Conducted: Hydrostatic @ Pneumatic C Nominal Operating Pressure O Other @ Pressure 1790 psi Test Temp.
7's 'F System Functional - 1230 PSIG for 10 Min. NOTE: Supplemental sheets in forrr of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form, \\ ..,(12/B2) ' TAis Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
3 FORM NIS 2 (Back) Install flow orifice PO-55-lD010A and PO-55-lD0 LOB in niace of
- 9. Remarks Applicable Manufacturer's Dets Reports to be attached FO-55-lD010 and spacer plate respectively.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replacernentconforms to tna rules of the S'iP'***'"*"* ASME Code, Section Xl. Not Applicable Type Code Symbol Stamp Not Applicable Certificate of Au oritation No. Not Applicable Expiration Dr. NI Signe-B.C.I. Project Construction Date N 19 Owner or Owner's Designee, Title yp CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid comm;ssion issued by the National Board of Boiler and Pressure Vessel inspectors and the State The Hartford Steam Boiler Inspection &of Pennsylvania and employed by or Province of Hartford, Conn. have inspected the NrSp5N3cshrDd Inspecp's Signature National Board, State, Province, and Endorsements Date OU 19 Y (12/82) J
f. FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME l' ode Section XI October 9, 1984
- 1. Owner Philndelnhia Flectric Company Date Nome 2301 Market Street. Philadelphia.Pa.19101 Sheet I
of I Address
- 2. Plant T.4mprick Generatine Station Unit I
Name P.O.Roy A.Sanatoga Branch.Pottstown.Pa. Bechtel Job #8031 19464 Repair Organization P.O. No., JoD No., etc.
- 3. Work Performed by[ Rech tel Construction.
Inc. Type Code S'ymbol Scamp No t Applicable Authorization No. Not Applicable Name 90 Ronlo Street. San Francisco. Ca. Expiration Date Not Applicable Address
- 4. Identification of System Roncf or Enclosttre HVAC 34A Addenda,H-316.1606 Code Case
- 6. (a) Applicable Construction Code 19 *
- Edition, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 Winter 81 N-308 See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME
~. National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufa,cturer Serial No.
No. Identification Built or Replacement or No) Replace-24" Butterfly m 1_,m ru n,e ~. Ht.No.ADW N/A HBB-124 N/A ment No < n i n a.1 Plate Machine Co. 32C
- 7. Description of Work Rine Dlate welded around stem to stuf fing box, sealing valve in open position. This replacement renders the valve non-functional.
- 8. Tests Conducted: Hydrostatic Pneumatic @ Nominal Operating Pressure O Other Pressure 70 psi Test Temp. N/A
- p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
\\ (12/82) This Form (F00030) may be obtained f rom the Order Dept.. ASME,345 E. 47th St., New York, N.Y.10017
I I e FORM NIS 2 (Back)
- 9. Remarks Replacement was performed and completed eer ASME Section XI replacement Applicable Manuf acturer's Date Reports to be attached olnn 8031-FM-30 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thisReplacement e.onforms to the rules of the ASME Code, Section XI.
Not Aeolicable Type Code Symbol Stamp Certificate of Au h rization No., Not Annlirnble Expiration Date Not Aonlicable Signed Constriction Date d* 19 M # B.C.T. Proiect / Owner ~or owner's. Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State The Hartford Steam Boiler Insoection & of or Province of PAnnAVIVA"ia and employed by have inspected thb[oNNekts hebribed Mnrefnrd-Innn-S/1 /W . and state that in this Owner's Report during the period 9[ /EY to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. /* 8 A 7bY N/ Commissions Insp@or's Sign National Board, State, Province, and E endorsements 9'3~ 6 / /6 is case (12/82) .}
i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI October 9, 1984
- 1. Owner Philadelphia Electric Company o,,,
Narne 2301 Market Street, Philadelphia,Pa.19101 Sheet I of 1 Address
- 2. Plant I,imerick Generating Station unit I
Nerne l P.O. Box A,Sanatoga Branch,Pottstown,Pa. Bechtel Job #8031 Ad d" 19464 FleDelt organization P.o. No., Job No., etc.
- 3. Work Performed by Bechtel Construction. Inc.
Type Code Symbol f'arnp Not Applicable Authorization No. Not Applicable Name 50 Beale Street, San Francisco. Ca. Expiration Date Not Applicable Ad dress
- 4. Identification of System Standbv Gas Treatment 70A 19
- Edition, Addenda,N-316.1606 Code Case
- 5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Winter 81 N-308'
- See Spec. 8031-P360, Rev. 9
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code National
- Repaired, Stamped Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manufacturer Serial No.
N o. Identification Built or Replacement or No) 18" Butterfly Replace-Valve Ring Colonial Ht.No. ADW N/A HBB-128 N/A ment No Plate Machine Co. 32A
- 7. Description of Work Ring plate welded around stem to stuf fing box, sealing valve in open position. This replacement renders the valve non-functional.
- 8. Tests Conducted: Hydrostatic Pneumatic M Nominal Operating Pressure O Other Pressure 70 psi Test Temp. N/A
'F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) Informa. tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form, s (12/82) This Form (E00030) may be obtained from the Order Dept., ASME,345 E 47th St., New York, N.Y.10017
S FORM NIS 2 (Back)
- 9. Remarks Ron1 ncomon e un e norfnemoA nnA en-nloenA nov ARMF Romeinn YT vonlanomone Applicaole Manufacturer's Data Reports to be attached nlon kn31 nL37 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Ron1 n eo-on e conforms to the rules of the
'#*D'*****"' ASME Code, Section XI. Noe Anolicable Type Code Symbol Stamp Certificate of Autho l2ation No, Not Annl i e nbl e Expiration Date Not Annlienble Owner or Owner's Designee. Title - Construction Date M ~U 19 .C.T. Proient ~ Signed / g, p CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid comrnission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Penng*1vnnin and employed by The Mnrtford Stenm Boiler Tnsnection & of have inspected thb5rkoNth dhskrIbed 14n re f nr A - Innn-E / f/M . and state that in this Owner's Report during the period II,/(/ N to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in eny manner for any personal injury h property damage or a loss of any kind arising from or connected with this inspection. b_/LT' A 7-[b~ M> N Commissions u inspectorpensture Nationsi soord, state, Province, and Endorsements d //O 19 Date ~f (12182) J ~
4 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company July 13, 1987 2301 Market Street Name Philadelphia, PA 19101 Sheet of Address Limerick Generating Station One (1) unit Nem Evergreen Road PECo Mod 34 Pottstown, PA 19464 Address Repolt organization P.O. No., JoD No., etc.
- 3. Work Performed by Philadelphia Electric Comoany Type Code Symbol Stamp N/A Construction Division Name Authorization No.
N/A Limerick Section, Pottstown, PA Expiration Date N/A Address Containment Atmospheric Control System (57)
- 4. Identification of System
- 5. (a) Applicable Construction Code ASME,III 19 74 Edition, Winter ' 74 Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 80 with Addenda thru Winter 1981
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes Component Manu f acturer Serial No.
No. Identification Built or Replacement or No) P.O. # or (Heat #) Stock Code # b" 5ch 40 Pipe ASME SA-106GRB P471060870-2 U71839 N/A None N/A Replacement No (2) 6" 130# Flange SA-105 GRII P473062861-2 CND N/A None N/A Replacement No (1) b" 130# Flange SA-105 GRII P473062861-2 GDAW N/A None N/A Replacement No (3) 6" 150# Flange SA-105 GRII P473062861-2 39 S N/A None N/A Replacement No (2) l' 3000# Half Coup. SA-105 GRII P4730600 AEP N/A None N/A Replacement No Add redundent isolation valves to the hydrogen recombiner system.
- 7. Description o' work
- 8. Tests Condurled: Hydrostatic Pneumatic @ Nominal Operating Pressure C Other O Pressure 75 psi Test Temp.
Rn
- F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa.
tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is nurnbered and the number of sheets is recorded at the top of this form. 112/82) Thi.t Form (E00030) may be obtained from the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017
s FORM NIS 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company (PECo) July 13, 1987 g,,,
- 1. owner 2301 Market Street Philadelphia, PA 19101 Sheet of Address One (1)
Limerick Generating Station
- uni,
- 2. Plant Evergreen Road Name Pottstown, PA 19464 PECo Mod 34 Repair Organization P.O. No., Job No., etc.
Ad o*ess N/A Philadelphia Electric Company Type Code Symbol Stamp
- 3. Work Performed by Construction Division N* ma Authorization No.
N/A N/A Limerick Section, Pottstown, PA 19464 Expiration oste Address Containment Atmospheric Control System (57)
- 4. Identificat on of. System i
- 5. (a) Applicable Construction Code ASME,III gg 74 Edition, Winter ' 74 Addenda. N/A Code Case 80 with Addenda thru Winter 81 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19
- 6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
- Repaired, Stamped National Name of Name of Manufacturer Board Other Year
- Replaced, (Yes N o.
Identification Built or Replacement or No) Serial No. # Component Manufacturer P.O. # or or Heat Stock Number 6" 150# C.S. 82-2053-Butterfly Valve Clow 02N-02 N/A HV-57-166 1983 Reolacemen t Yes 6" 150# C.S. 82-2053-Butterfly Valve Clow 02N-03 N/A HV-57-169 1983 Reolac emen t Yen (2) 3/4" half coup SA-105 GRII P473060008-2 ACE N/A None N/A Reolacemen t No (2)3/4" half coup SA-105 GRII P473060008 2 0821 N/A None N/A Replacement No (1) 3/4" half coup SA-105 GRII P473060008-2 0950 N/A None N/A Replacement No W rehMent udath vaM m de h6 gen reedher system.
- 7. Description of work
- 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure O Other Pressure i;
psi Test Temp. AO _F Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) infortna. NOTE: tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. _, (12/8,2) Thjs Form {E00030) may be obtained from the Order oept., ASME,345 E,47th St., New York, N.Y.10017
, o, 4 FORM NIS 2 (Back) epah m prbmd h uw&m dd ME E EP M Mdde 3
- 9. Remarks Applicable Manuf acturer's Data Meports to be attached Specification 8031-G-33. Rev. 3 ERRF's L-932, L-793, L-799, L-748, L-734, L-735, and L-736 valves HV-57-166, and HV-57-169 were HV-57-162 and HV-57-164 respectively the NPV-1 valve reports are attached.
9 CERTIFICATE OF COMPLIANCEreplacement onforms to the rules of the We certify that the statements made in the report are correct and this c 'i'*P**""' ASME Code, Section XI. N/A Type Code Symbol Stamp N/A N/A g,pi,,, ion oat, Cerfif qte of Authoriza)n o. Limerick Section Wh. _fkt echanical Branch Heado,,, N% 27 W ,39 n Owner or Qwner's Ciesignes Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State Hartford Steam Boiler Inspection & og Pennsylvania and employed by or Province of Hartford, CT Insurance Compqu inspected the components described /( M . and state that N in this Owner's Report during the period // to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions National Board, State. Province, and Endorsements insopor's Signat WM 1997 Date / (12/82) .. o..
. a r FORM NIS.2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS ~ As Required by the Provisions of the ASME Code Section XI 1, owner phil adelnhi n Fleceric comnany o,te o/30/87 nom. 2301 Market Street .5 ce 1oint Sheet I of
- o. w.. 4_1_, A m. t m k 4 e
_. r - -
- 2. Plant 1 4 - o
- 4 c t-noma
- ed"&
Ce"*4ne Unit One NamW Evergreen and Sanatoga Roads n--
- 4.,
~-g._
- e.., - i. n t. o n m, e,.,
g 3 N/A
- 3. Work Performed by T>h 41 n A o 1 pk 4 e 1"1 o r
- M a f* ~n n riy Type Code Symbol Stamo
^"'" ' ' ' ' " " " - N#^ 2301 Market Street Exoiration Cate N/A v h. 4 1, A_ a_ l e h_ _4 _,, t o i_ n t p, Snubbers, System 103 4 acentificarian ot System Fabrication: ANSI B31.7, 1969 Edition thru Winter, 1972 Addenda Ibbb~b Code Case 19 77 Edition, Winter 77
- Addenda, S. tal Acolicable Construction Code ASME/ III 80 thru Winter 81 Addenda (b) Apoliccole Edition of Section X! Utilized for Recairs or Rectacements 19
- 6. Icentirication of Components Reesired or Replaced and Replacement Components ASME Cece g
~ Receired: S:8moeo W NPT ~ Year R ectaced, (Yes Name of "N ari-c'f~~ 'Manu f acturer " CERT - Other [
- i#^
8""'
- '"I Component Many,ctu re r Serial No.
NO. SP-EBB-ll4 l Size PSA-1/p Pacific 1 Snubber Scientific Cc 20672 N-1198 Ji-H5 81 IReplaced Yes Size PSA-1/4 Pacific SP-EBB-114 l Snubber Scientific Co. 25774 N-1198 J1-H5 82 Replacement Yes Size PSA-1/2 Pacific GBB-118-l 2 Snubber ! Scientific Co. 14474 N-1198 H65 82 Repl' aced Yes {uplace ent Size PSA-1/4 Pacific GBB-118-Snubber kientific Co. 16609 N-1198 H65 82 Yes
- 7. Description of Work
- Refer to Block 9
- 8. Tests Conductec: Hydrostatic 1] Pneumatic t] Nominal Operating Pressure psi Test Temp.
F Other [ Pressure corresponding MFG,s Data Report Succlemental sheets in form of lists, sketenes, or drawings may be used, provided (1) see is 8h in. x 11 in., (2) Informa, NOTE: tion in items 1 inrousn 6 on tnis report is incluced on eacn sheet, and (3) each sneet is numcered and the numeer of sheets is recorced at the tes of this forrn. This Form (E00030) may ee cetained from the Orcer Dect., ASME,345 E. 47th St., New York, N.Y.10017 (12/82) ~. e n - - - - - ~ - - _ _ _. _ _ _. _ _ _ _ _ _ _ _ _
As Required by the Provisions of the ASME Code Section XI 9/30/87 twner Philadelphia Electric Company care i. Name 2301 Market Street 2 or 5 Dh41ndp19hin_ pn. 10101 Sheet Accren One
- 2. Plant Limerick Generating Station Unit N.m.
Evergreen and Sanatoga Roads D. n_ Rnv A. Annntoen. Pn. 10464 Acoress ~ Rooser o rsentr apon P.o. N o., Joo No., etc. N/A
- 3. Work Performed by_. Philadelphia Electric Comeany Type coe, symooi stamo N/A Authorization No, 2301 Markee Street N/A Philadelphia. Pa.
19101 Et jrat.on case Ao aren Snubbers System 103 4 identification of system l Fabrication: ANSI B31.7, 1969 Edition thru Winter 1972 Addenda IbbE"b Code Cue (
- 5. (a) Apoticacie construction code ASME/III is77 sdit,onWinter 7 7
- Addenca, 80 Thru Winter 81 Addenda f
M Aeolicable Edition of Section XI Utilized for Repairs or Replacements 19 6 Identification of Components Repaired or Replaced and Replacement Comoonents ASME g N NPT Repaired. Stamped CERT. otner year A eolaced. iYes Name of Name of Manu f acturer como oneni uanuf acturer seriai No. NO. identification suut or Restatement or No) E x SP-DCA-177 Size PSA-1/2 Pacific Snubber Scientific Co 9501 N-1198 El-H6 82 Replaced Yes 3 Size PSA-1/2 Paeific Snubber Scientific Co. 16550 82 Replacement Yes SP-DCA-318 Size PSA-1/2 Pacific Snubber Scient ic Co. 16485 N-1198 El-H3 82 Replaced Yes 0 Size PSA-1/2 Pacific 16618 82 Replacement Yes Snubber Scientific Co, SP-DCA-185 Size PSA-1/2 Pacific snubber Scientific Co'. 11970 N-1198 El-H6 81 Replaced Yes lpaolacement l Yes 5 Size PSA-1/} e,acific en lc_.15418 82 P emehr 4m-re cs - Size PSA -3 Pacific I Anukhar sc4 a -4 +4 e cn J 17271 N-11CR DCA-101 M70 81 Replaced yes 6 Size PSA -3 Pacific 17284 81 Replacement v,, c nkhar c:c4 mr4 <4-co, n Size PSA -10 Pacific l 12857 N-1198 -507-H40 ( B1 82 Reolaced I v---- ScientificCo) Snubber y l 7 Size PSA-lu Faciric Snubber ScientificCoj 17346 86 l, , _,i y,3 Size PSA - 10 Pacific l J j Snubber Scientific Co 9273 N-1198 ' HBC-91-H40 (B) 81 IReplaced Yes 8 Size PSA-10 Pacifit c-nkk e sc4-ei r4-rn 17564 87 Faplacement Yes-l Size PSA-10 Pacific 9 c"nkk-cc4
- 4 #4 r en 12853 H3C-507-H105(B)I 82 Replaced Yes Size PSA-10 Pacific Snubber Scientific Co 17342 86 Replacement Yes Size PSA -l ) Pacific
"'4 ""4 < 4 c rn 12858 N-1198 H3C-507-H105(A) 82 Reclaced Yes 10 Size PSA-10 Pacific Snubber ~ Scientific Co, 17334 86 Feolacement Yes ~' l f f
FORfWNIS 2 OWNER'S REPORT FOR MPAiR5 OR REPLACuauv is A.* Recuired by the Pf ovisions of the ASME Code Section XI 9/30/87 ' Philadelphia Electric Company cate 3, own,, u.m. 2301 Market Street 3 5 Philadelphia. Pn. 19101 sheet o, Acoren
- 2. Plant limerick Generatin2 Station Unit One
~,,n. Evergreen and Sanatoga Roads P. O. Box A. Sanatoen. Pn. 19464 Accreu Repair organir suon P.O. No., Joo No,, ege, Philadelphia Electric Company Type Coce Symboi stamp N/A 3 Work Performed by_ Authorization No. N/A 2301 Market Street N/A Philadelphia, Pa. 19101 Expiration Date Ac or.n Snubbers System 103 4 identification of system Fabrication: ANSI B31.7, 1969 Edition Thru Winter 1972 Addenda Code Case "in g 77.Accenca,
- g;; 3
- 5. (a) Acolicable Construction Code A CMr /$1U __19 7 7 E dition, e
(b) Applicable Edition of Section XI Utilized f or Repairs or Replacements 19-84-Thre Winter 81 Addenda
- 6. Identification of Components Reosired or Replaced and Replacement Components A$ME Coce
- Repaired, Stameed N
NPT Name of Name of Manu f acture r C ERT'. - Other Year F ' ' d - (Y O 'd'" i'* 2 i " 8 "i': 'N l b Component Many f actu rer Serial No. NM X [ Size PSA-10 Pacific Snubber Scientific Co. 12854 N-11oR Woc-507-M40(h R? Replaced Yes 8 11 Size PSA-10 Pacific bolacement Yes AA Snubber Scientific Co. 17341 -H105(Af Size PSA-10 Pacific Snubber Scientific Co. 7992 N-11oA une 01... _ An Replaced Yes 12 Size PSA-10 Pacific A7 F4 placement Yes Snubber Scientific Co. 17561 Size PSA-10 Paeific l Snubber <cieatific Co.' 10014 N-1198 GBB-119 Mll (B) 81 Replaced Yes 33 Size PSA-10 Pacific 07 Rer12-n-vmt vee e - n u,- e.r 4 c4 - em 17460 e Size PSA-35 Pacific 6366 N-1198 GBC-101-M64 80 Replaced Yes 14, c-nw o. e 4 .a4 - cm Size PSA-35 Pacific A7 Replacement Yes Anubbe* Ceiaer4 #ic en. 12805 01-Ml81 l Yes Size PSA-35 Pacific Replaced
- " ~~ ~
- ^
"ize PSA-35Pacific 15 S 87 poe13-Yes Snubber Sci.eir4e Co.12816 Size PSA-35 Paci.fic l l 16 """hha" Ced
- 4 #4 c rn.
99n N_ tion .r.c a _1 n r, _u 17 I no Replaced v,. Size PSA-35 Pacific l 07 Replacement Yes Snubber Scientific Co. 1?Ano Size PSA-35(, Pacific Replaced Yes l e 4
- 4 s4 c en.
9&A v_ tion en _in7_uct3 3on 9nubba-c 77 Size PSA-35LPacific Rnnhhe* Rc4
- 4#4c rn.
501 87 Replace ent Yes L acific P Size PSA-35 c i-ti e4 r Co. 162 N-1198 EB B-103-H10fA) 78 Replaced Yes 18 S"uhber r Size PSA-35LPacific 87 Reolaceme-t vae Rnuhhe-cc4
- 4ed-rn.
502 ^'~ ~ i f
As Required by the Provisions of the ASME Code Section XI Philadelphia Electric Company case 9/30/87 1, o wner name 2301 Mar,ket Street. 4 of 5 pse,nao,se On toint sheet 'AQ or oss
- 2. Plant i 4 = ped rie Canprnring C; P n r 4 nn Unit One u.me Evergreen and Sanatoga Roads D
n Rnv A Rnnnenen pn 1 o!_4 /_ R oosie Organia stion P.O. No,. JoD No., etc. Ac or ess 3, Work Ferformed by Ph4inAp1nh4n F1perr4e en~nnny Type Coce Symool Stamp N/A N/A Auth rinti n No,_ 2301 Market Street N/A Ph41 ndol nh4 n. Pn_ 141/'1 Expiretion Date Acorens Snubbers Svstem 103 4 seentification of system Fabrication: ANSI B31.7, 1969 Edition Thru Winter 1972 Addenda S. (a) Applicsole Construction Coce ASME/III 39.7,,7 Edition, Winter 7 7 Accenca,1 b d d -b Code Case 80 Thru Winter 81 Addenda M Acolicaole Edition of Section XI Utilized for Repairs or Replacements 19 6' Identification of Components Reesired or Replaced and Rectacement Components ASME Coce g
- Repaired, Stamped g
NPT Otner Year R eplaced, '(Y e s Name of Name of Manuf acturer or Reelecement or No) Component Manuf actu ef Senal No. C EF.T. Identification B uilt O r No. Size PSA-100 Pacific Snubber Scientific Co. 812 N-1198 EBB-104-H15 80 hepla.ced ye, [ g Size PSA-100 Pacific Snubber Scientific Co. 1232 N-1198 81 Replacement ym Size PSB.0SPacific 8 Scient i C. 153 N-1198 DBA-107-H23 m Replaced ,yes 20 Pacific Strut 84 Replace::ent yes Scientific Co. 165 N-1198 Sizd PSB.05Pacifi: Compensating Scientific Co; 158 N-1198 DBA-107-H22 83 Replaced ve, Strut Pacific c e. ~4 c4 c ro .257 N-11o8 83 Pggin m e yes r e I l I I I I I
Sheet 5 of 5 FORM NIS-2 g, pernarks Snubbers f ailed Functional Test ST-4-103-301-1 or inspection per PMQ-500-080, and we re replaced in*conceois Meaututurer's ones a. corti to be set =cn.a accordance with the following MRF No.'s: INDEX MRF NO. INDEX MRF NO. li 8700546 12. 8704848 2. 8704127 13. 8704609 3. 8705404 14, 8704230 L A70n970 19 A70L71c 5. 8704440 16. 8704792 6. 8704425 17. 8704175 7. 8704989 18. 8704174 R. 8704845 19. 8700509 o A7040AA en o7ngqgo 10. 8704987 21. 8706367 11. ,8704988 CERTIFICATE OF COMPLIANCE h4M.dm fsJO-conforms to the rules of the "G*W We certify that the statements mace in the report are correct anc r.s-s"*"'D"*"' ASME Code, Section Xl. Type Coce Symbol Stamp - Expiration Date Certificate of Authorization No. M E b C '*
- lO U 19 7
Date Signed. Qwner or Owner's Dedonie, Titie d i i CERTIFICATE OF INSERVtCE INSPECTION 1, the undersigned, holding a valit* commission issued by the National Board of Boiler and Pressure Vessei insoectors and the State M.vNA/ 9cm Mk n' Is.dM_WuM* d*z of MM and ernployed by or Provi e of MM A M_ bO/JO have insoected t e components described M[ _ and state that in this Owner's Aeport c%iing the perioc ydlY7 to to the best of rny knowtedge and belief, the Owner has performed examinations and taxen corrective n easures dis:rtbed in this Owner's Aeoort in accorcance with the reovirements of the ASME Coce Section XI. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or imotied, concerning the examinations and corrective measures cescrioed in this Owner's Report. Furthermore, neither the inspector nor his employer shall be lisole in any manner for any personal injury or property camage or a loss of any kind arising from or connected with this inspection. YIY 21-Commissions ~.tio n., u.... si.t.s,o.inc...no e no....rn.ets i e.cyo, i. a n. a nuc ca,e f 02/s:) _}}