I PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE October 3, 1975 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE --PN-75-101 This preliminary notification constitutes EARLY notice of events of

., POSSIBLE safety or public interest significance.

The information l

presented is as initially received without verification or evaluation l

and is basically all that is known by OIE staff as of 3:30 p.m. on the date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS j

NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO

(

BE INACCURATE OR INCONSISTENT. AN OFFICE OF INSPECTION AND ENFORCEMENT

~

NOTIFICATION OF AN INCIDENT OR OCCURRENCE (BLUE SHEET) SUBSEQUENTLY

-WILL BE ISSUED IF WARRANTED.

Facility: Pilgrim 1 Boston Edison Company

{

\\

Subject:

DAMAGED RELIEF VALVE PIPE RESTRAINTS IN TORUS 4

~

The licensee reported that during a planned inspection of the status of piping and restraints in the torus, two out of four relief valves discharge pipe restraints were observed to be damaged to the extent that parts of the restraints are missing. A more detailed inspection will be' performed on-10/3/75 as water. level is further reduced. A piping flexibility analysis M

is in progress. This event will be reviewed during an inspection previous-ly scheduled for 10/6/75.

=

Media interest is expected because of close press attention to Pilgrim activities. The State of Massachusetts has been and is being kept informed'.

A press release is not pisnned.

OIE received notification of this occurrence by telephone from licensee at 2:30 p.m. 10/3/75.

Contact:

FADreher, IE x7261 HDThornburg, IE x7353 JGDavis, IE x7541 0

/

Distribution:

/

Chairman Anders Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky Commissioner Rowden G. F. Murphy, JCAE Commissioner Kennedy C. C. Kamerer, CA O

N L. V. Gossick, EDO D. F. Knuth, IE J. A. Harris, PA O

B. C. Rusche, NRR J. La Fleur, ISP T. J. McTiernan, AIA S

K. R. Chapman, NMSS H. K. Shapar, ELD N

Transmitted: P Bldg */Jfy ; E St yQ@; MNBB /d/Mg; Luge m e, PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE e

( f#

L l

9807310113 751003 PDR ISuE i

FN-75-101 PDR j