ML20236Q644
ML20236Q644 | |
Person / Time | |
---|---|
Site: | La Crosse File:Dairyland Power Cooperative icon.png |
Issue date: | 11/12/1987 |
From: | DAIRYLAND POWER COOPERATIVE |
To: | |
Shared Package | |
ML20236Q633 | List: |
References | |
NUDOCS 8711200200 | |
Download: ML20236Q644 (42) | |
Text
{{#Wiki_filter:_ _ _ _ _ _ . _ _ _ _ _ _ - _ _ _ _ _ O $8 ATTACIIMENT 1 , i PROPOSED TECHNICAL SPECIFICATION PAGES 8711200200 871112 PDR ADOCK 05000409 P PDR PCl-39
6.0 ADMINISTRATIVE CONTROLS 6.1 RESPONSIBILITY 6.1.1 The Plant Superintendent shall be responsible for overall unit operation and shall delegate in writing the succession to this responsibility during his absence. 6.1.2 The Shift Supervisor (or during his absence from the Control Room, a designated individual) shall be responsible for Control Room command function. A management directive to this effect, signed by the highest level of corporate mar.cgement shall be reissued to all station personnel on an annual basis. 6.2 ORGANIZATION OFFSITE 6.2.1 The offsite organization for unit management and technical support shall be as shown on Figure 6.2 1-1. UNIT STAFF 6.2.2 The unit organization shall be as shown on Figure 6.2.2-1 and
- a. Each on duty shift shall be composed of at least one Shift Supervisor with a Senior Reactor Operator License and one Operator, who is qualified as a Control Room watchstander.*
- b. A qualified Control Room Operator or Shift Supervisor shall be within visual and/or audio distance of the Control Room annunciators.
- c. All spent fuel handling shall be directly supervised by either a Licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling.
- d. At least one additional Operator and one Health Physics Technician shall be onsite when spent fuel or a spent fuel shipping cask is being handled or when non-routine evolutions are being conducted in the Fuel Element Storage Well.
- Shift crew composition may be one less than the minimum requirements for a period of time not to exceed 2 hours in order to accommodate unexpected absence of on duty shift crew members provided immediate action is taken to restore the shift crew composition to within the minimum requirements. This provision does not permit any shift crew position to be unfilled upon shift change due to an oncoming shift crew member being late or absent.
6-0 l Reference 5 also affects this page. PCl-39 E_____________________________________.___ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ . -
_ _ . - . = . _ _ - . . - - - - ._ e d i THIS PAGE INTENTIONALLY LEFT BLANK. 6-4 Reference 5 also affects this page. PC1-39
4 l ATTACHMENT 2 STAFFING EVALUATION I i l l i 1 1 1 i _ _ ___ _ D
MINIMUM STAFFING REQUIREMENT
SUMMARY
Minimum Staffing Potential Accident CFH/SRO* Control Room Aux Operator Other Qualified Qualified Qualified 1 Loss of Offsite Power 1 Loss of FESW Cooling 1 Uncontrolled Liquid Waste 1 1 Discharge 1 FESW Pipe Break 1 1 Wind and Tornado 1 1 Seismic Event 1 1 1 2 Fire Spent Fuel Handling 1 1 Accident 1 Shipping Cask or Heavy 1 1 Load Drop into FESW
- Currently, the Shift Supervisor is required to be a licensed Senior Reactor Operator. After the Decommissioning Plan is approved, a certification program will be conducted in lieu of maintaining licensed operations personnel. The l Shift Supervisor will then be a Certified Fuel Handler, rather than an SRO.
I l l
----------_--_______,,_,m. _ _ _ _ _ _ _ _ _ _ _ _ _ , _ _ _
. es i '
i l. LOSS OF i l Emergency Dieselj l l--------jGenerators Startj--------------------------------------- l Loss l l0f l - jlA EDG Sta l0ffsitej--------jlB EDG Starts l---l Operator Attemtpsl l
.l Power l l1A EDG Doesn't l lTo Start 1A EDG l---l l0ccurs l - l Operator l l-- l Start 1A i
l - l1B EDG Sta
! l l l l-----l1A EDG Starts l-----l Operator Attemptsj---l l l1B EDG Doesn'tl lTo Start 1B EDG l l l - l Operator l l Start 1B l - lBoth EDGs l l l l l Operator S l - l1B E No l l ! l l l ---- lNeither EDGl--------j0perator Attempts l-----joperator S l Starts l lTo Start Both EDGsl-- l1A N l
l l Operator
- l Start Eith - ~
$ITE POWER l l llB FESW l l Operator Restarts l------------ ,_____________-----l Running l----l---lCCW Pumps l l l l l i l _____ 0_- e I 1 0 8 8 1 1 l l - l operator Cross- ll l _ l l l l connects Ess. Buses l- l stl--(----------(--l1B FESW Pumps l--- l _l l l l l Running l---joperator Restarts:------------ l l l l1B CCW Pumps l
. . i m I i 1 n ,
= . .<__i i t i i i 1 ' l l -l operator Cross- l l 4 l I li l connects Ess. Buses l _ $ 1 i stl--(----(--------lNeither FESWl-------j0perator Restarts l---------------- _j l i l i l i l Pump Can Runl l1A CCW Pump j a ! a ml- I l I i m I i a re tsl------ l TI LI ! APERTUltE i, CARD l i is-l_________ he Avadahle on Li %perture Card T j---------------lNeither FESWl--------lNeither CCW l-------------------- Gl [D,G l Pump Can Runl l Pump Can Runj (continued on next page) 3mlAObaOO-01
rr -.,--, --_ -- 1
. i i
LOSSOF0$ (cos lHPSW Diesel (s)l lOperats
-------l Start On Low l---------------------------------------------jCross-a l lHPSW Pressure l l lHPSW TG l l l Coolers l lHPSW Diesels l l0perator Attemptsj l1A Or 1B HPSW l- ----jDo Not Auto l---lTo Start 1A Or 1Bj---jDiesel Startedj l Start j lHPSW Diesel jj l lNeither HPSW l -l Diesel Can Be l-----------o l Started j lHPSW Diesel (s)l ---l Start On Low l l lHPSW Pressure l l 1
1 1 1 l lHPSW Diesels l l Operator Attemptsj l1A Or 1B l l l Operator l
-jDo Not Auto l---lTo Start 1A Or 1Bj---lHPSW Diesell---l Manually l--c l Start l lHPSW Diesel jj l Started l l Cross- l l l connects l l lNeither l lHPSW To j -jHPSW Can l- lCCW Coolers!
- . lBe Started l l l
................................<..,/ ................o 1
i l lTo Compensate For !
-----------------------------instrumentation l------------------------o lWithout Power And/or!
lAfter Batteries Are l l Depleted, Operator l l Checks FESW Locally l l Periodically j
- As of January 1, 1988
l 1 iSITE POWER
- 'd)
JHanually! l Adequate FESW j l Evaluate Emergency l lMake Required l inn: cts l----l Cooling Achieved l---l Plan l---l Notifications l CCW l i l o______._______________ l 1 i l l l l i, /some FESW Cooling l l '{'{ &chieved. As Con-l-- l .e rvatism Assume l ll APER,I,URE4 2 me As No Cooling l ll ll l Operator Addsj CARD ll - l Colder Water l l j j lFrom OHST l Also AvaMahle on ll lWhich Delays l a_------------------- l l l l Boiling l bdure Ord l l o------------------l Evaluate l---lMake l---lFESW l------------------- l Emergency l l Required l l Starts l l Plan l lNotifi- l l Boiling l l cations l lAfter l l5 Days *l i-S711ao0800 - ca. 1 (continued on next page) ? i I b _ _ _ _ _ _ . _ . _ _ _ _ . _ _ . _ _ .b
LOSS OF d (cs l Operator Adds l l Operator Adds l
- l Colder Water j - l Colder Water l l lFrom OHST Whichl l lFrom OHST Whichj j l Delays Control l l l Delays Fuel j j l Rod Uncovering l l jUncovering l l l l l Tops of j l l Top Of Fuel j ----------l Control Rods!-----------l Uncovered l l Uncovered atl lat 23.1 Days *l l13.6 Days
- l l
l l
*As of January 1, 1988 1
f. iI _ _ _ _ _ _ _ _ . _ . _ _ _ _ . _ . _ _ _ . _ _ _ _ _
manm_-- i $ITE POWER d) l rgig APERTURE CARD Also AvaHahle On Aperture Card 8'1II9009D0- 05
s LOSS OF OFFSITE POWER NO. OF PEOPLE LOCATION TASK C.R. 1 PLANT l OF EVOLUTION l COMMENTS
! l l
- 1. Loss off offsite power 1 l l Control Room l Recognize alarm occurs. l l l l l l l l l
- 2. Operator attempts 1 l l Control Room j to start diesels. l l l l l !
! l !
- 3. Operator cross- 1 l l Control Room j connects Ess. Buses. l l l l l l
\ l l
- 4. Operator restarts 1 l l Control Room j CCW pumps. l l l I I
\ l l S. Operator starts HPSW 1 l l Control Room l Pumps. l l l l l l l l l
- 6. Operator starts HPSW j 1 l Cribhouse j locally. l l l
\ \ \
l l l
- 7. Operator cross- l 1 i Turbine Bldg.j connects HPSW to CCW j l Mezz. l Coolers. l l l l l l l l l
- 8. Operator takes local l 1 l Cont. Bldg. l FESW 1evel. l l 701' Level l l l \
l l l
- 9. Operator adds water to l 1 l Cont. Bldg. j FESW. l l 701' Level orj l l Relief Valve l .'
l l Platform j i l l l ! l
- 10. Evaluate as per 1 l l Control Room l Certified Fuel Emergency Plan. l l l Handler l l l
\ l l Page 1 of 2
I l LOSS OF 0FFSITE POWER NO. OF PEOPLE LOCATION TASK C.R. ! PLANT ! 0F EVOLUTION l COMMENTS l l l
- 11. Make notifications as 1 l l Control Room l per Emergency Plan. l l l Minimum Staffing Requirements 1 - Certified Fuel Handler Qualified 1 - Auxiliary Operator Qualified l
)
l I 1 1 Page 2 of 2 I m_ _ _ - - - - - - - - -- - - - - - - - -- - i
y LOSS l l l lBoth FESW l l Loss Ofl l Pumps Failj---lFESW l-------------------------------------------- l Cooling l l i l I i lBoth CCW j l Loss Ofl l l Pumps Faill---jFESW l l lOr CCW l l Cooling l l l System j l---jo l Shutdown l l lM l lF l lP lBoth LPSW l l Loss Ofl l Operator! lHPSW Cross! lFESW l l l l Pumps Faill---jFESW l---lAttemptsj---jConnected l---l Cooling l l l0r LPSW l l Cooling l lTo Cross- l Restored! l l System l l Connect j j l Shutdown l lHPSW To j jHP5W Cannotj j lCCW l---jBe Cross- l---------------l l l Coolers l l Connected l l l Loss Ofl l lFESW l l l Cooling l l lFor l lOther j lCause l u_ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _ _ _
F FESW COOLING l
-l Action Taken) l lTo Restore l l l Cooling l l
l l l Time To Boiling l l l Operator Adds! lAnd Uncovery l l-l Water to FESWl---l Increases l I l rator j l Operator j l lOperatorj lFESW l l Top Of l l Top Of l itors l---l Monitors l---l Monitors l---l Commences l---l Control M Temp! l---l Fuel l lFESW j lCB Rad- l l Boiling j l Rods j (Un-iodi- l l Level l liation l lAfter j lUncoveredj l covered l ly -l lPeriodi- l l Levels j j5 Days l l13.6 Daysj l23.1 l lcally l lPeriodi-l l Days j lcally l TI APERTURE CARD Also AvaMahle On HAparture Card 81II9000D0 - 04
4 LOSS OF FESW COOLING LOCATION .l TASK NO. OF PEOPLE j OF EVOLUTION l COMMENTS C.R. l Plant l l
! l l ! .j
- 1. Recognize loss 1 l l Control Room l of FESW cooling l l l
\ l l l l l
- 2. Operator tries to i 1 j T.B. Mezz. l l j
cross-connect HPSW l l Floor l; j j l to CCW Coolers. l l l
- 3. Operator monitors 1 l l Control Room l FESW temperature. l l l l l l l l l l
- 4. Operator monitors 1 l l Control Room j {
FESW 1evel. l 1 l or 701 Level l l l l l l
- 5. Operator adds water 1 l l Control Room j l l to FESW.- l l l l l l l
- 6. Operator monitors 1 l l Control Room j Containment Building j j l l
Rad levels. l l , l ! ! ' 7.~ Action taken to 1 l l Control Room j ESWSS Restore FESW ccoling. l 2 j Outside & T.Bj Possibly (long term) l l Grade. l I l l Location l j j could vary l ' l j depending on j j j cause. l ; Minimum Staffing Requirement 1 Control Room Qualified Operator a Page 1 of 1 l I t L
,d 9n-UNCONTROLLED l Operator Starts Pumping l l Contents Of j l Waste or Retention Tank l---l Normal Activity l lTo River Which Is Not j l Sampled Or Was l---l Contents Of l---l Waste Water l---l Auto Val l Incorrectly Analyzed l lHigh Activity l l Monitor Alarms l l Closes O lHigh Acti lTerminati lDischa
hUIDWASTEDISCHARGE ~ l---l Auto Valvej - l Operator Closesj-------------- l l Fails To l---l jValve From C.R.l l yl 'lClose l l l l Call In l l l l--l Desired j _l l l lPersonnelj l l l l Valve Will Notl--l Operator l-
- lClose Remotely l l Terminates!
l Discharge l l Locally j ryrg APERTURE CARD Also AvaMahle On
~%perture Card 89 IDotoD2 sod- 06
UNCONTROLLED LIQUID WASTE DISCHARGE OPERATOR RESPONSE ACTIONS
~ LOCATION NO. 0F PEOPLE l OF EVOLUTION l COMMENTS
! TASK ' C.R. j Plant- l l i j 1 l
- 1. Operator observes high 1 l l Control Room l waste water activity .l l l l j alarm. l l l ! !
o L l ! !
- 2. Operator checks waste 1 l l Control Room l ;
water activity monitor. l l l l I I l l l l I
- 3. Operator checks flow to' 1 j j Control Room j j
see if valve closed. I l l l l
\ l l
- 4. Operator tries to close 1 l l Control Room l valve using thumb- l l l wheel. l l l l I l l l ! !
- 5. Operator manually closes l 1 l T.B. Grade l valve near standpipe. j l l ,
l l \ \ l l l
- 6. Operator stops running i 1 l T.B. Tunnel l l pump. l l or C.B. l l l Basement l l l '
l l l j j
- 7. Call in desired 1 l personnel. l l l l
Onshift Staffing Required (Minimum Required) 1 in Control Room - Control Room Qualified Operator 1 in Plant - Auxiliary Operator Qualified Page 1 of 1 l l 1
.=-
7 i I i l FESW SYSTEM lFESW System l IFESW Startsj lFESW Lo/Highl l Operator! l Operator l l l l Pipe Breaksj---lTo Lose l---l Alarms In l---l Checks l---l Checks l---l l Water l l Control Room l jFESW j l Rad l l lWhen Level l l Level l l Monitors! l l Drops To l l l695' l l Operator Checks l l Operator Initiates!
-----l0ut Situation Inl---l Additional Makeup l---
l l Protective Cloth- l l ling With Rad l j l Monitor If No l l l lHigh Rad Alarms l l l Operator l l Operator l lWhen level l l l---l Secures l---lDe-energizes l---jReaches ~ l-- l l jFESW Pumpj l Electrical l l686' Control! l Equipment Inj l Rod In Upper! l Cont. Bldg. l l Tier Start. l lTo Uncover l lOnce Level Stabilizes! l Estimate Dose l l Call In l l Assess
-----l Operator May Secure l---lIn Containment---l Additional l---l Corrective l Remote Fill Valve l l Building l l Personnel l l Action l Options *0ther FESW Lines Penetrate The Well Higher Except For The Bottom Entry Pump -w
i
-I .j 1
J }PE~ BREAK 1 4 1
- l I
.i i
st. Bldg.'-(CB)l -l Operator Opens l- l Operator Checks! lOperatorj ,' Boding, Alarms l---lFESW Remote l---lDemin Water l---lMay Iso-l------ Deictor,DC l l Fill Valve l- l Availability l l late-CB l pund: Alarms Inj ' atrol' Room- j
' l, l Operator In l' - l Control' Room l - 'l l Checks Rad j l 2rea Rad j. l' l Monitor l l l Lowest Level l Normal FESW l Monitor. l--l l Reading ~l. l---l Reached Is l---l Cooling Un- l- -- .,
j~ 679' lAvailable, 11 arms Irl- lL l l j sontroll l l lEveryone In .l l lSee Loss Of l~ loom And-l. l .jArea' Evacuates l l lFESW Scenario.l Locally ~l- .l Including l- lThough Less l l Operator j jTime is Avail-l lable For Action lTo Restore l l Cooling, > 1 l l Day Still To l l Boiling l
-l Team Re-enter l p-lCB for Assess- .'jmsnt And/or -l I
['****** g r1tI,2Db2DO- Ola L~ TI .scharge Line Which Has Redundant Check Valves. APERTURE f ~ CARD r Also XvaMahle On
~%perture Card
m.; ,
-r E+ ,
FESW' SYSTEM PIPE BREAK
.1 NO.:0F~ PEOPLE- -LOCATION:
TASK- C.R. !' PLANT
~
l OF EVOLUTION !' COMMENTS l l l'
- 1. Low'FESW alarm. .1 j. l Control Room'l-
- l gl l -l l l l 2.LOperator checks FESW 'l - .l .. j Control' Room l
. level.- ,j 1 l 701 Level l I 'l .l
- 3. Operator checks' Rad. 1- j. l Control Room l-monitors. j' .l l !
l j i : I i l Containment Building
' 4'. 1 l - l Control Room.l ' flooding alarm & DC. l j. l Ground alarm.
- l. l 'l 1
!. l l l l .
l
- 5. Operator, opens FESW 1 l l Control Room l Makeup Valve. l l l ,
l l l l
-l l- l 6.. Operator checks Demin 1 l l Control Room l 'I Water availability. l l l l l I.
I i !
-7.-Operator isolates 1 l l Control Room l Cont. Bldg.. l 1 j Locally iso- l l l lates manual l l l valves in l l l T. B. Tunnel l l l l :
i i !
- 8. Operator enters Cont. I j.
'l Control Room l Bldg.'to check out j 1 l l situation if possible. l l l l ! ! .l 1 i 9.: Operator, initiates' l Relief Valve l -l 1 additional makeup. l l Platform l I I l \ . l \ l
- 10. Operator secures FESW 1 l l Control Room l
, ' pump.~ j 'l l C.B. Grade l l l Floor l l Page 1 of 2
_ _ . . , _ _ _ _ _ _ - _ _ _ _ _ - _ . - _ - - - _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~ - - - ~
! I l. l FESW SYSTEM PIPE BREAK l I NO. OF PEOPLE LOCATION TASK C.R. ! PLANT ! 0F EVOLUTION l COMMENTS I l ! 11.. Operator opens MCA 1 l l Control Room i breaker switch, j j l l l l l l l l l
- 12. Operator received Hi 1 l l Control Room l J Rad monitor alarms & l l l evacuates Cont. Bldg. l l j f l l l \
! l l \
t
- 13. Estimate dose in Cont. 1 l l Control Room l CFH Qualified Bldg. l l l l l l
! ! l
- 14. Call in more 1 l l Control Room j personnel. l l l l l l l l l
- 15. Assess corrective 1 l l Control Room l Long term. No one actions and teau j 2 l Cont. Bldg. l enters alone after ,
enters Cont. Bldg. l l l eracuation. l to assess or repair. l l l Minimum Staffing Requirements 1 - Certified Fuel Handler Qualified 1 - Auxiliary Operator Qualified
\
1 1 l i Page 2 of 2 3 0 l
a_ . - i, WIND _ lIf Operator l_ l lIs In C.B.,l l l j0perator ll l Design l l Containment l l Turbine l lIf Stacksj j l Survives ll l Basis l---l Building l---l Building l---jFall,Theyj---l l-- lHigh l l Withstands l l Diesel l lDo Not l l lIf Operator l l l Wind Orl l Event l l Building l l Impact CBl l_lIs Elsewherel_l l Tornado l lCribhse j lMay Survive j l Event l l Switch- l l0ccurs*l l yard Arej l Damaged j
- Of Magnitude and Causing Damage as Discussed in the Consequence Study.
_ _ _ _ . _ . _ _ _ _ _ _ _ _ _ ,, _ , mm.. o 7
)
iTORNADO' s, I i l1 1 Qtential. j '- ~jSubstantialj l Assess l ~ lClassifyj- lMake Reg'dl' l Call Inj 2nt ':- l---l Time _ .l---l Damage l---l Emergency--lNotifica- l--lHP And l. l ncques.l l Available-. .l lTo l- ~jPer Planj ltions l lOther j
- Most . j l(Days) Be- j ' l Equip-l l Desired!
tcern Are .l fore Action l l ment l l Person-j. -l bilar.Tol- lMust be l lnel l 3s 0f' 'j; .lTaken To l 7 site. j. .l Protect- ! Mr Withj -l Fuel j > Blure Ofl-5 Onsitel rer l l l r [ 891I2002h0- 01 h Tl APERTURE l1 CARD . Also Avaliable On~ Aperture Card L:____.___- _ _ _ _ .___:___.__u_______________.__.-____._______________ __ .__:.____n________________.____.____.____ _ _ _ o
~
l
.j WIND AND TORNADO LOCATION TASK NO. OF PEOPLE l OF EVOLUT10" l COMMENTS C.R. l Plant l l l l l 1, Recognize event. 1 l l Control Room l l l l l l l
- 2. Operator survives. l 1 l Cont. Bldg. l Operator in l l l Control Room may l l l not survive.
l l l l l l l
- 3. Assess damage to 1 l 1 l Plant Tour & l equipment. . l l Control Room l l l l l l l
- 4. Classify as per 1 l l Control Room l .
Emergency Plan. l l l l t l l l l l l 1
- 5. Make required 1 l l Control Room l~
notifications. j l l l l l l l l
- 6. Call in other 1 l l Control Room l l personnel. l l l
- Refer to Loss of Offsite Power for Subsequent Actions ;
Minimum Staffing Requirement 1 Certified Fuel Handler Qualified 1 Auxiliary Operator Qualified 1 i Page 1 of 1
._ __.- l I,
a N
) Sf l!
1 N f ) F
)'
t l: i j' f' . l-1 i'
)
l Design Basis l l Cont. Bldg.l lSome Damagaj lIn Cont. Bldg.l lFESW L l~ l Earthquake- j---lAnd Stacks l---joccurs To l---lSome Equipment l---l Break-l
!' l0ccurs j l Withstand j l Diesel Bldg l l Damage, FESW -j lCausia
- 3. l Event l lTurb. Bldg.j l Intact, Dis- l l0f Lem lCribhouse l l charge Line -l '
Point 1 l Intact Between! Contrs lWell And Check! lAre Ps l Valves l lUncov@ l Fuel @ lCoverm wm______.
2IC EVENT May l l Consequences Similarl l Loss Of Offsitel lSubstant.l l Assess l sherel---lTo FESW System Pipe l---lAnd Onsite Power---l Time (Day)---l Damage l 1ss l l Break Event, But l lPossible Due Toj lAvailablel lTo l o j l Remote Fill Valve l l Switchyard, l lFor l l Equip-j te l lMay Not Work. Local l l Turbine Bldg. &l l Response.l l ment l bds j l(701') Rad Levels l l Diesel Bldg. l l Refer To l 111y l lHigh, But Time l l Damage. l l Loss Of l But! lAvailable For l l0ffsite j .ns j l Response l l Power ! l l Event l TI APERTURE CARD Ab4 AvaMahle on Aperture Card e7ll200200 -08
SEISMIC EVENT LOCATION TASK NO. OF PEOPLE j OF EVOLUTION j COMMENTS C.R. l Plant l l
! l l
- 1. Recognize event. 1 l l Control Room l l l \
! l l
- 2. Assess damage to 1 l 1 l Plant Tour & l equipment. j j Control Room l l ! !
! ! l
- 3. Add water to FESW 1 l l Control Room l remote. l l l l ! !
l l l 3a. Add water to FESW l 1 l 701' Level j local. l l l l l l l l l
- 4. Response to affected 1 l l Control Room l equipment. l l l Refer to Loss of Offsite Power and/or FESW Line Break for Subsequent Actions Minimum Staffing Requirements 1 - Certified Fuel Handler Qualified 1 - Auxiliary Operator Qualified l Page 1 of 1
ne l l Fire l l Fire l l Operator j l Operator l lFireResponsej l Breaks l-----l Alarm l---l Responds By l-----l Announces l---l Team Respondst lOut j j l_ l l Checking Panelj l l Fire & l lTo Assess ; j l l Location l l Situation : l l l lOn Pane l l l Fire l l0bserverl l
- jobservedl---lContactsj-----
l Control l l Room l 1 i l
(RE l l l l Operator! l Fire Re- l l Person Calls! l Operator l i--l Starts l---lsponse Teamj-----l Genoa Fire l-----l Monitors l l1 HPSW j l Fights Fire l-- l Dept. For l jj lHPSW Sys. l l l Diesel l l l Assistance l ll l Rad Monitorj j I II I _________________ l l l lIf Fire In l l
- l Control Room, j -- . . , .
l Operator l l Monitors HPSW j l Diesels Locally l (continued on next page) - 87/1260200 - D9 TI APERTURE CARD Also Avagable On Aperture Card
F (C
- l Fire Inl---jFire It j l Turbine l l lContro l l Bldg. ll lRoo l l l 1 l
l---l Fire Inl---l Lose l l Diesel l lEss. l lBidg. l l& 1B l l Int. l l125V I l lD.B. l l l
- lMake Requiredj - l l l Notifications! l l Account l l l Evaluate l l l--lFor All l---l---l Fire In l---lL ----lIf Emer- l lPersonnell l l Cont. Bldg.j lF lgency Perl l l l Plan l l l -jSpr j l l& P l l Fire Inl l lW/0 l---l Crib- l---l l l l house l l l l lHPS l -l Dam l
l i l l i l l l Fire In Otherj l
- l Building Or l---l l0utside ll l
ll
-l l
l l
i
;i n-
>lOpsrator j---l Potential Plant l---l Considerable l---l Concentration l l Monitors:l !~l Consequences l' jTime Avail- l lOn Extinguish-l-lHPSW Sys.l l'l Bounded By Loss l lable (Days) l ling Fire l lFrom- ' j-l l0f Offsite . l lTo Correct. l -lCribhousej l l Power' Accident j .jEquip. Damagej sl---'l Potential l---l Consider-.l---lConcentra l---l Operator l---l Operator l l- l Plant Con- lable Time l- l tion on l l Starts l l Observes l l lcequencesl lAvailablel l Extinguish- l1A FESW j lFESW l bl l Bounded By l(Days) Tol- ling Fire l l Pump If j l Locally l 'l l Loss Of l- l Correct -l lNot j lPeriodi- l ,j l0ffsite l- lEquipmentj. jRunning l lcally l l Power. l l Damage l lSince FESW . jAccident'j. l Level Inst. l Analysis j. lW/0 Power l l Refer Toj l Considerable l Concentration l ,l---l Potential l Damage Of-l---l l- Loss Of l---l Time Avail- l---jon Extinguish-j j l Concern Isj jFESW l lable (Days) l ling Fire l o gj :-l Loss Of l l Cooling l lTo Restore l H lFESW Pumpsj 'l Accident l lFESW Cooling l l Hook Up Toj---lConcentra-l Drs . Work , l .. lG-3 For l l tion'On j i st.Firo l- l Fire Sup- l l Extinguish-cificant l lpression j jing Fire l nt Damaanj -lLPSW Pump (s) l-----------------l Water Or j i j lStill Operatej j lUse ESWSS l ) Scolsl-----l ! l Pump l Tl i j -lLPSW Pumps l---l Consequence l l Damaged l lTo Plant l APERTURE lSame As ! CARI) , l Loss of FESWl l l Cooling / l l Considerable! Also AvaMahle on l Time (Days) l '%perttare Card lAvailable Toj l Restore j Plant l l Concentration On l 87/120DMb-m l nequencesl---l Extinguishing Firej ' 9 in l- l Loss Ofj l Considerable l lImmediate l lGo To Loss! schyard l---l0ffsitej---jTime Avail- l---l Concentration l---l0f Offsitej Dgas j l Power l lable (Days) l lOn Extinguish- l Power l 1 grve l lTo Respond l ling Fire l l Accident j psformerl l i _ . _ . _ . _ _ _ _ . _ _ _ _ _ l
FIRE NO. OF PEOPLE LOCATION TASK C.R. ! PIANT ! 0F EVOLUTION ! COMMENTS l l l
- 1. Fire alarm & acknow- 1 l l Control Room l ledgement. l l l l l l l l l
- 2. Fire observed and l 1 l Plant !
Control Room contacted. l j j
! l l l l l
- 3. Operator alerts fire 1 l l -l brigade. l l l 1 l l l l l
- 4. Fire brigade responds. 1 l l Control Room j j 1 l Fire Location l Brigade leader l l l l l l
- 5. Operator starts > 1 _
1 l l Control Room l HPSW pump or ensures l l l auto start. l l l l l l l l l
- 6. Fire fighting, j 3 j Fire Locationi 1-Operations l l l 2-Other or Ops.
1 l l Control Room l Calls additional l l l help from local ; l l l Fire. Dept. l l l
- 7. Operator monitors Rad 1 l l Control Room l levels, HPSW pressure, j 1 l Fire Location! Brigade leader.
& adjusts vent flow as l l l directed. l l l l l l l l l l '
- 8. Fire in Control Room- l 1 l Cribhouse l operator monitors HPSW l l l pressure in Cribhouse. j l l 3 I I l i ! l l
- 9. Evaluate as per 1 l l Control Room l Shift Supervisor i Emergency Plan. l l l i
Page 1 of 2 l 1 l E____---------- 1
- . f l
FIRE i l
.NO. OF PEOPLE LOCATION ' . TASK C.R. ! PLANT l OF EVOLUTION l COMMENTS ! ! l 10.'Make notifications. 1 l l Control Room l I I' I l l l ,
- 11. Account for personnel. 1 l l Control Room l l 1 l Fire Location!
I I I l l l
- 12. Fire in Cribhouse- l 2 l River Bank orl l deploy ESWSS Pumps or' l l SW of Turbine l cross-connect with l l Building l G-3. l l l l NOTE:' Fire in other locations covered by other scenarios. i Minimum Staffing Requirements l
4 People of which 1 1 - Certified Fuel Handler Qualified, Fire Brigade Leader Qualified 1 Control Room Operator Qualified, Fire Brigade Leader Qualified 1 i i j Page 2 of 2 i i f _ _ _ . ____ _ __ a
r H: [. y a. SPENT FUEL E o lDuring Fuel l- l Fuel l l Cladding l l Cladding l l Area. j' l@ l Handling'Inl'--l Assembly l---lOn All- l---l Gap Gas 'l---jRadiationl---lC u jFESW, Fuel'l l Hits l l Pins In ~ l l Activity. l l Monitor- j' lQ l Assembly' l lAnother j. lBoth As- l .l Starts 'l l Alarms .'l j@ 1 Drops Off j l Assembly l- lsemblies j jExiting l l Locally &l- -l6
.lHolst l ~
lIs Damagedj l Cladding-l lIn Control. jy j& Bubbling l l Room' l lUp Throughl l Pool Waterj l Prompt Actions l lLong Term
- l Cont. Bldg. l------- jRelease Is l---lSame As In Other j ---l0fl Activity What TG
(
? 'jIsolates- j' l l Limited l l Chain But Offsite.
l l l Dose Less l L 'll or more l l Operator (s)l l Cont. Bldg.l
- l Cont. Bldg.l---jAttempts tol---lIs Isolated l l Iso. Valves l 'l Isolate . ll '~
lMonitorj lDo Not~ j l Cont. Bldg.l-l .l Cont. Bldg. lClast lClose l lCannot Be .
---l Stack l---lEmerg
_l Isolated j l Release l lPer0 l Stack l l Max. Postulated Offsite Dose *l
- l Release l---l0.05 mrem Whole Body l-----------------------<
l l4.2 mrem Skin l
~
l
.....j j l Ground Release l l Max. Postulated Offsite Dose *j l Monitor - l(Leak To other l---l2.25 mrem Whole Body l---j0ffsite- < lThan Turbine Bldg)j. j187 mrem Skin j l Rad Leve:
- As of October 1987
-~
L L . s L SLING ACCIDENT ~ pber ofj. l Fuel = l Cont. Bldg.l jOperator j l Operator.l---------- D1.' -l a-l Handling; ---l Gas Activity---jchecks- l---l Evacuates l $dling l l Crew . l Monitor- l l Activity & l Cont. l bw Op:ns . lEvacuatej l Alarms In l l Radiation l l Building' l tidg2- ~ j' .jControl Rm'l l Monitors j msker j j l btorminstionl Do With' l a Building: ! t-lfy lMake Notifi- l l Call In l lMake Pre- l l Monitor j sney.; e---l cations To l---lHP Tech.l---l11minary Dosej---lOnsite l------ > Plan l; - .l State, County l l Assessment l l Rad Levelsj lNRC, Plant l
-jSupt. And l
l Reactor Eng. l , 1 l l
- n. l
'! l .l -l Conduct Dosej- l Develop l l 3;l-----l Assessment l---jRecovery Plan l' l y; 87//Zbogoo-II 2l -- TI APERTURE CARD i Also Avalfable On " Aperture Card
7, {3 i
, 4 SPENT FUEL HANDLING ACCIDENT NO. OF PEOPLE LOCATION TASK C.R. l PLANT ! 0F EVOLUTION 1 COMMENTS l 1 - . l '
- 1. CFH opens bridge l 1 l 701' Level l breaker. l l l J
l l l l l l ?
- 2. Operator checks C.B. -1 l l l activity and radiation. l l Control Room l l I l '
I l l
- 3. Operator evacuates C.B. 1 l l Control Room j I l l l l l
- 4. Operator tries to j l j isolate C.B. remotely. 1 l l Control Room l I I I l l l
- 5. Operator tries to l 1 l T.B. Tunnel l {"
isolate C.B. locally. l l l
! l l t l l ,
- 6. Monitor stack releases. 1*l l l l l l
; l l
- 7. Classify as per 1 l l Control Room j Shift Supervisor Emergency Plan. l l l l l l l l l
- 8. Make notifications as 1 l l Control Room l per amergency Plan. l 4
l i l i
- 9. Monitor onsite dose l 1 lOnsite levels. l l l l l !
! ! l
- 10. Preliminary assess dose. 1 l l Control Room j CFH Qualified
- CFH and/or Control Room Qualified Operator i
Minimum Staffing Requirements 2 People j
?
1 - Certified Fuel Handler Qualified i 1 - Control Room Operator Qualified l Page 1 of 1 ! l 1 l _ _ - - - - _ _ _ _ _ - _ - - - - - - - - - - _ - - - - _ - - - _ - - - - - - - .- l
t
! ennus ' cttw
- O t,
11 SHIPPING CASK OR L lDuring Fuell l Heavy l l Cladding Ofl l Cladding Gap l l Area l ll l Shipping, l l Load j lAll Fuel l l Gas Activity l l Radiation l l; l Shipping l---lDropsj---l Assemblies l---jStarts Exiting--l Monitors l --- j( l Cask Falls j lInto l lIn FESW l l Cladding And! l Alarm j ll jFrom Crane l lFESW j l Ruptures l l Bubbling Up l l Locally & l jj lInto FESW l lThrough Pool! lIn Control! l Room l l .' l i l lReleasej ll L - l Cont. Bldg. l--------------------------------------------jIs l --- j f
- l. l l Isolates On l l l Limited l l1 l lHigh Activityj j lj l l l1 l _l Cont. Bldg.l--- h l l lIs Isolated! l(
l l1 Or More Cont, j l Operator (s)l. l lj
- l Isolation Valves l--jAttempts Toj---!
l lDo Not Close j l Isolate l l_ jCont. Bldg.j l Monitor l lCls l Cont. Bldg.l lCannot Be l---l Stack l---l Ems l Isolated l l Releases l l As 2 lPer
- l Stack l----------l Max Postulated Offsite Dose *j-l lReleasej l4.2 mrem Whole Body jj ___
l l350 mrem Skin ll lMonitorj lCor
---l l---j0ffsitel---lDo; j l Ground Releasej l Max Postulated Offsite Dose *l l l Rad j l&g - l Leak To Other l---jl86 mrem Whole Body l- l Levels l lThan Turbine l l15.6 Rem Skin l l Building l
- As of October 1987
~a
f 3 -.
-Qj 'l j
LOAD DROP INTO.FESW I Ej; l Cont. Bldg.lL 'l Operator.j l Operator.l
~- l '. 'l Gas Activity- l Checks. . l l Evacuates l ;
I~ L l --- l Monitor'. . Ll---l Monitor ~l---l Cont. l------------------
.l. 'l Alarms:In j. lFor Ac . l l Building j ill - l Control' - l 'jtivity & l ll Room' j'- l Radiation)-
1
.)
Actions l .lLong Term l OIn Other---l Determination l 1 ) But- j j' jof What To Do! i 3 Do Notl jWith7Activityj p Ba:Taken. -lIn Building j skly And j . ; fDoses'-l i se - j. 1 l- 'lMake Notifi-l l Call In l lMake Pre-j -l Monitor l. [---l cations To l---lHP Tech (s)l---lliminary l---lOnsite l----------- l [. 'l County,'NRC,l j& Anyone j l Dose l Rad j ) [ 'l State, Plant! lElse l l Assessment l Levels !
-jSuperinendent l Wanted l ;jReactor Eng.j- !
l i o. ji l Develop-l < Recovery l @[---{i Plan , [ ((M M M /g T1 ! APERTURE j CARD Aha Available On Aperture Card i
l N'
.j ' SHIPPING CASK OR HEAVY LOAD DROP INTO FESW i LOCATION TASK NO. OF PEOPLE l OF EVOLUTION l COMMENTS '
C.R. j Plant l l
! l l
- 10. Dose assessment. 1 l l Control Room l CFH Qualified I ! l i j i
- 11. Monitor Rad levels. 1 l l Control Room l Note: 10 & 11 done l l l at same time and i j j l continue for dur-l- l l ation of release. i Minimum Staffing Requirement I
3 People of which !a l 1 - Certified Fuel Handler with Dose Assessment Training i 1 - Control Room Qualified Operator l 1 - Auxiliary Operator Qualified l
\
I Page 2 of 2 o
r. 1:, 1 J 1 1 1 SHIPPING CASK OR HEAVY LOAD DROP INTO FESW l 1 i 4 LOCATION NO. OF PEOPLE j OF EVOLUTION l COMMENTS j TASK
.C.R. l Plant j' l ! l l
- 1. Cask or heavy load 1 l l Control Room l At'least 1 drop into.FESW. l 2 l 701' Level l CFH's.
I l l l l l
- 2. ARM's alarm locally 1 l l Control Room j
& in Control Room. l l l l i
l l I
! l ! l '
- 3. Containment Building 1 l l Control Room j evacuation. l l l ,
l !
! l ! l
- 4. Operator. monitors Rad 1 l- l Control Room j monitors in Control l l l
. Room. l l l l l l l l l l
- 5. Recognize Containment 1 l l Control Room l Building not isolated l 1 l T.B. Tunnel j l l and isolate remotely l l and/or locally. ! l l .l l l l l l l
- 6. Monitor' stack releases. 1 l l Control Room l l l l
\ \ \
- 7. Classify as per 1 i l Control Room l Shift Supv.(Cert.
Emergency Plan. l l l Fuel Handler)
- 8. Make notifications as 1 l l Control Room l Emergency Plan. l l l I I I I I I
- 9. Call in additional 1 l l Control Room l personnel. l l l l l l l l l Page 1 of 2 l
l
-- - - - - - . _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ .}}