ML20236L428
| ML20236L428 | |
| Person / Time | |
|---|---|
| Site: | Portsmouth Gaseous Diffusion Plant |
| Issue date: | 07/02/1998 |
| From: | Hiland P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | John Miller UNITED STATES ENRICHMENT CORP. (USEC) |
| Shared Package | |
| ML20236L430 | List: |
| References | |
| 70-7002-98-07, 70-7002-98-7, NUDOCS 9807130006 | |
| Download: ML20236L428 (2) | |
Text
- _ - _ _ _ _ _
1 i
i l
July 2, 1998 L
Mr. J. H. Miller Vice President-Production United States Enrichment Corporation Two Democracy Center 6903 Rockledge Drive Bethesda, MD 20817 i
SUBJECT:
NRC INSPECTION REPORT 70-7002/98007(DNMS) AND NOTICE.
OF VIOLATION
Dear Mr. Miller:
On June,8,1998, the NRC completed a routine inspection at your Portsmouth Gaseous Diffusion Plant. The enclosed report presents the results of that inspection. The results of our Inspection over a seven-week period covered by the enclosed report indicate that the conduct l
of activities at your Portsmouth Gaseous Diffusion Plant was generally adequate.
i Based upon the results of the inspection the NRC has determined that violations of NRC requirements occurred. The violations are cited in the enclosed Notice of Violation (Notice) and the circumstances surrounding the violations are described in detail in the enclosed report. The first violation involved a failure to have adequate administrative controls in place during the conduct of a maintenance activity. The second violation involves a failure to meet Technical Safety Requirements during an autoclave mode change. Together, the violations are a concern because they indicate continued problems with the overall conduct of your operations.
You are required to respond to this letter and should follow the instructions specified in the enclosed Notice when preparing your response.. The NRC will use your response, in part, to determine whether further enforcement action is necessary to ensure compliance with regulatory requirements.
p L
in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter, its i
enclosures, and your response will be placed in the NRC Public Document Room.
f 9807130006 900702 PDR ADOCK 07007002 C
PDR i
l J. Miller {
l l
We will gladly discuss any questions you have concerning these observations.
l Sincerely, 1
Original Signed by I
Patrick L. Hiland, Chief L
Fuel Cycle Branch I
Docket No. 70-7002 l
l Certificate No. GDP-2
Enclosures:
- 2. Inspection Report 70-7002/98007(DNMS) cc w/encis:
J. M. Brown, Portsmouth General Manager i
D. B. Waters, Acting Manager, Portsmouth Regulatory Affairs H. Pulley, Paducah General Manager S. A. Toelle, Manager, Nuclear Regulatory Assurance and Policy, USEC l
Portsmouth Resident inspector Office L
Paducah Resident inspector Office j
R. M. DeVault, Regulatory Oversight Manager, DOE l
E. W. Gillespie, Portsmouth Site Manager, DOE l
j Distnbution-L Docket File w/encis -
l PUBLIC IE-07 w/encls L
OCFO/LFARB w/encls R. Pierson, NMSS w/encls P. Ting, NMSS w/encls W. Troskoski, NMSS w/encls P. Harich, NMSS w/encls l
.Y. H. Faraz, NMSS w/encls C. J. Paperiello, Rlll w/encls J. L. Caldwell, Rill w/encls C. D. Pederson, Rlll w/encls Rlil Enf. Coordinator w/encls R. Bellamy, RI w/encls EJM, Ril (e-mail)
D. B. Spitzberg, RIV/WCFO w/encls IEO (e-mail)
DOCDESK (e-mail)
Greens w/o encls DOCUMENT NAME: G:\\SEC\\POR98007.DNM To receive a co my of this document, Indicate in the box: "C" = Copy w/o attach /end "E" = Copy w/ attach /end "N" = No copy OFFICE Rlli:DNMS C.
l l
l NAME-Hiland:irb G,0V DATE 07/02/98 OFFICIAL RECORD COPY