I d
DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED flfLC Geu %w DOCUMENT TRANSMITTED HEREWITH CONTAINS 10 CFR 2.790 INFORMATION
,i-Mr. R. W. Shtrk:;y July 2, 1998 Director, Regulatory Affairs ABB CENO Fuel Operations Combustion Engineering, Inc.
3300 State Road P Hematite, MO 63047
SUBJECT:
INSPECTION NO. 70-36/98-202 AND NOTICE OF VIOLATION
Dear Mr. Sharkey:
The Nuclear Regulatory Commission (NRC) conducted a routine inspection of your facility's material control and accounting (MC&A) safeguards program on June 8 - 12,1998. The enclosed report presents the results of that inspection.
The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. At the conclusion of the inspection, the findings were discussed with you and members of your staff.
Based upon the results of the inspection, the NRC has determined that a violation of NRC requirements occurred. The violation is cited in the enclosed Notice of Violation, and the circumstances surrounding the violation are described in detail in the enclosed report. The violation is of concem because it indicates an incomplete understanding of licensee requirements to maintain current knowledge of items listed in the item control program. Also of concem is the licensee's missed opportunity for corrective action prior to identification of the issue by the NRC inspection. Current knowledge of items must be maintained to ensure the safeguards risk of material loss, theft, or diversion is adequately addressed.
Under the provisions of Section 2.790(d), reports containing information related to a licensee's MC&A program are exempt from public disclosure. Accordingly, Enclosure 2 will 091 be placed in the Public Document Room.
i Should you have any questions concerning this report, please contact me at (301) 415-7156.
i i
Sincerely' Original signed by Philip Ting Philip Ting, Chief Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS i
Docket No. 70-36 1
License No. SNM-33
Enclosures:
As stated
" " Qg#y
_. m,-
cc w/ enclosures:
Dr. Bruce Kaiser, Vice President a
g 'g Fuel Operations, ABB CENO i
l cc w/o enclosure 2: R. A. Kucera, Director l
Missouri Department of Natural Resources I
DISTRIBUTION:
'I Docket File 70-36 SSoong,FCLB JOlencz, FCOB TPham, FCLB PDR, LPDR (w/o encis)
LOng, FCOB YChen, FCOB FCSS r/f bjf NMSS r/f FCOB r/f MMessier, T9E10 (w/o encts)
MRodgers, PMDA (w/o encts)
PHiland, Rill Case File l
DOCUMENT NAME: (ABB disk) 98-202-M.ABB BSmith, IMNS OFC FCOB E
FCOB E
FCOB E
FCOB FCOB THarich[ CCollinsCK DWhalek WT (s90shk PTjrtgJ NAME DATE 7 / /98
? /aj98 9/7/98 59[
)/2 98
(
C = COVER E = COVER 4. ENCLOSURE N = NO COPY d
OFFICt AL RECORD COPY y vcUJ DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED ThDCllMFNT TRANSMITTED HEREWITH CONTAINS 10 CFR 2.790 INFORMATION l
'l 9907800&%) (2fE@5L _ E -
w,
DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED fpunp%OCUMENT TRANSMITTED HEREWITH CONTAINS 10 CFR 2.790 INFORMATION p-T UNITED STATES s
j NUCLEAR REGULATORY COMMISSION
\\
,, }* '
WASHINGTON, D.c. 20666 4001 July 2, 1998 Mr. R. W. Sharkey Director, Regulatory Affairs ABB CENO Fuel Operations Combustion Engineering, Inc.
3300 State Road P Hematite, MO 63047
SUBJECT:
INSPECTION NO. 70-36/98-202 AND NOTICE OF VIOLATION
Dear Mr. $harkey:
The Nuclear Regulatory Commission (NRC) conducted a routine inspection of your facility's material control and accounting (MC&A) safeguards program on June 8 - 12,1998. The i
enclosed report presents the results of that inspection.
The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. At the conclusion of the inspection, the findings were discussed with you and members of your staff.
Based upon the results of the inspection, the NRC has determined that a violation of NRC requirements occurred. The violation is cited in the enclosed Notice of Violation, and the circumstances surrounding the violation are described in detailin the enclosed report. The violation is of concern because it indicates an incomplete understanding of licensee requirements to maintain current knowledge of items listed in the item contiol program. Also of concern is the licensee's missed opportunity for corrective action prior to identification of the issue by the NRC inspection. Current knowledge of items must be maintained to ensure the safeguards risk of material loss, theft, or diversion is adequately addressed.
Under the provisions of Section 2.790(d), reports containing information related to a licensee's MC&A program are exempt from public disclosure. Accordingly, Enclosure 2 will Dnt be placed in the Public Document Room.
Should you have any questions concerning this report, please contact me at (301) 415-7156.
Since ly, Y
'(
P ng,Ch f Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket No. 70-36 License No. SNM-33
Enclosures:
As stated cc w/ enclosures:
Dr. Bruce Kaiser, Vice President Fuel Operations, ABB CENO l
cc w/o enclosure 2: R. A. Kucera, Director Missouri Department of Natural Resources DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED
_ _ _ _ _ _ _