. g.

Docket No. 50-423 July 24,1937 LICENSEE:. Northeast Nuclear Energy Company (NNECo)

FACILITY: Millstone Nuclea-Power Station, Unit 3

SUBJECT:

SUMMARY

OF MEETING RE:

INSERVICE TESTING PROGRAM FOR PUMPS AND VALVES (TAC #65326)

On June 2 and 3,1987, representatives of the NRC staff and NNECo met to discuss the additional information required to complete the staff review of the subject program. Enclosure 1 includes the list of attendees and the l

responses to staff concerns that were made at the meeting. The highlights of this discussion are summarized as follows:

1.

For all but one item, the NRC and NNECo agreed on the responses to staff concerns.

2.

NNECo and the EGAG reviewers (staff consultants) differ on whether the auxiliary feedwater check valves are to be designated as active or passive valves.

(See page 21 of Enclosure).

3.

NNECo expects to complete its response to staff concerns by July 11, 1987.

Based on this data, the staff expects to completc its review in October A

1987.

/S/

Robert Ferguson, Project Manager Project Directorate I-4 Division of Reactor Projects I/II 1

Enclosures:

As stated cc w/ enclosures:

See next page i

870B050232 870724 PDR ADOCK 05000423 P

PDR P

PDI-4 S

i RFerg sonteh JSt 7 4 /87

/

7 gp/87 7

i y.4

  • Mr. E. J. Mroczka Millstone Nuclear Power Station Northeast Nuclear Energy Company Unit No. 3 cc:

Gerald Garfield, Esq.

Ms. Jane Spector Day, Berry & Howard Federal Energy Regulatory Comission City Place 825 N. Capitol Street, NE Hartford, Connecticut 06103-3499 Room 8608C Washington, D.C.

20426 Mr. Maurice R. Scully, Executive Director Mr. Kevin McCarthy, Director Connecticut Municipal Electric Radiation Control Unit Energy Cooperative Department of Environmental Protection 268 Thomas Road State Office Building Groton, Connecticut 06340 Hartford, Connecticut 06115 Robert W. Bishop, Esq.

Burlington Electric Department Corporate Secretary c/o Robert E. Fletcher, Esq.

Northeast Utilities 271 South Union Street Post Office Box 270 Burlington, Vermont 05402 Haru'ard, Connecticut 06141 Mr. Thomas Shedlosky Senior Resident Inspector Office U. S. Nuclear Regulatory Comission Millstone III 3

P. O. Box 811 Niantic, Connecticut 06357-08 Mr. Michael L. Jones, Manager Project Management Department Massachusetts Municipal Wholesale Electric Company Post Office Box 426 Ludlow, Massachusetts 01056 Regional Administrator i

U. S. NRC, Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Mr. Karl Abraham Public Affairs Office, Region I U. S. Nuclear Regulatory Comission, King of Prussia, Pennsylvania 19406 l

Distribution (C

500 Fil j

NRC h & PDRs I

PD I-4 Reading

)

RFerguson

~

JStolz OGC-Bethesda EJordan i

JPartlow ACRS (10)

I HBClayton i

DCaphton l

TSullivan i

I I

4 l

i l

l I

l t

_