Text

___

_

. po '

l

'

. e ;-

p

z.,

,

l:

OCT 2 71997

I

l

Docket No. 50-483

'

Union Electric Company

i

-ATTN: Mr. Donald F. Schnell

l

Vice President - Nuclear

!

Post Office Box 149 - Mail Code 400

!

.St. Louis, M0 63166

]

1

Gentlemen:

1

i

This refers to the enforcement conference held in Glen Ellyn, Illinois, on

)

.0ctober 2, .1987, which was attended by you and members of your staff. This

j

meeting was held to' discuss recent inspection findings (Inspection Reports

i

No.:50-483/87023(DRSS) and No. 50-483/87028(DRP)),theapparentviolations,

J

and the applicable NRC enforcement policy.-

l

,The enclosed copy of our report identifies areas discussed during the meeting.

!

!

In.accordance with 10 CFR 2.790 of the Commissioner's regulations, a copy of

this letter and the enclosed report will be placed in the NRC.Public Document

i

.

Room.

!l

We will gladly discuss any questions you have concerning this enforcement

meeting.

'

Sincerely,

!

Oh SIGNED BY C. E. NOREurfs

Carl J. Paperiello

Deputy Regional Administrator

!

r

Enclosure: Meeting Report

No. 50-483/87034

'See Attached Distribution

f

6

h

l

RIII

RIII

RIII

RIII

RIII

RIII

S}I

1

VanSickle/jlr Hinds

Gill

Greger

Schultz

Forney

r ehid

(D

t

8711040062 871027

PDR

ADOCK 050004B3

G

PDR

b-.-

-

_

__

I

_ _ _

-

"

.

!' D

l

OCT 2 71977

Docket No. 50-483

Union Electric Company

ATTN:

Mr. Donald F. Schnell

Vice President - Nuclear

Post Office Box 149 - Mail Code 400

St. Louis, MO 63166

Gentlemen:

This refers to the enforcement conference held in Glen Ellyn, Illinois, on

October 2, 1987, which was attended by you and members of your staff.

This

meeting was held to discuss recent inspection findings (Inspection Reports

No. 50-483/87023(DRSS) and No. 50-483/87028(DRP), the apparent violations,

and the applicable NRC enforcement policy.

The enclosed copy of our report identifies areas discussed during the meeting.

In accordance with 10 CFR 2.790 of the Commissioner's regulations, a copy of

.

tilis letter and the enclosed report will be placed in the NRC Public Document

,

'

Room,

l

I

4

We will gladly discuss any questions you have concerning this enforcement

meeting.

Sincerely,

'

Carl J. Paperiello

Deputy Regional Administrator

Enclosure:

Meeting Report

No. 50-483/87034

.

See Attached Distribution

RIII 771

I

LI

RI .

RIII

RIII

RIII

SW

'

h

i

,_

WO$

[M

VanSickle/jlr

inds

11

e

~r

Schultz

Forney

Paperiello

/ 7L

\\ o 2'L

'#/c,0

',

lol Hl0

>/g;1,/7/

I

Gmn-ww

- - - _ _ - - - - _ - - _ _ - - _

)

..

.

-

,,

_

._ ..

__

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ - _ _ - _ _ _

We

'

,

\\

-

!

!

i

.

Union Electric Company

2 00T 2 71977

i

j

i

' Distribution-

l

cc w/ enclosure:

A. P. Neuhalfen, Manager Quality

Assurance

!

Tom P. Sharkey, Supervisor,

!

Compliance

"

'

DCD/DCB (RIDS)

' Licensing Fee Management Branch

Resident Inspector, RIII

Region IV

Resident Inspector, Wolf Creek

'K. Drey

Chris R. Rogers, P.E.

Utility Division, Missouri

Public Service Commission

CFA, Inc.

/

i

i

,

3