_ _ _ _ _ _ _ _ _ _ - _ _ _ _

1 Docket Nos.: 50-424 and 50-425 JUL 3 01987 Mr. James P. O'Reilly Senior Vice President - Nuclear Operations Georgia Power Company P.O. Box 4545 Atlanta, Georgia 30302

Dear Mr. O'Reilly:

Subject:

Staff Acceptance of Stainless Steel Ties for Use in Vertical Cable Trays for Vogtle Units 1 and 2 (TAC 63584)

By letter dated May 27, 1987, Georgia Power Company submitted its long-term proposal for support of cable in vertical cable trays, i.e., through the use of stainless steel cable ties. The staff has completed its review of this submittal and concludes that the use of stainless steel ties to support cables in vertical cable trays is acceptable.

The staff's evaluation is enclosed.

Sincerely,

\\ 6\\

Melanie A. Miller, Project Manager Project Directorate II-3 Division of Reactor Projects I/II

Enclosure:

As stated cc:

See next page i

DISTRIBUTION:

Docket. File,.

"NRC PDR Local PDR PDII-? Readir.;

BJYoungblood Reading SVarga/Glainas MDuncan 0GC-Bethesda EJordan JPartlow ACRS(10)

MMiller NRonin MP51+(e / rad MDu,IJ-k/DRPI/II PDI-yDRPI/II PDM p

/II PD ncan BJYoungblood 07/ /87 07/p/87 07/yd87

~

8708050059 870730 PDR ADDCK 05000424 P

PDR

50 Cec

+

o UNITED STATES g

E NUCLEAR REGULATORY COMMISSION 3

g 5 -

E WASHINGTON, D. C. 20555 N'...+ /

JUL 3 0 Edl Docket Nos.: 50-424 and 50-425 Mr. James P. O'Reilly Senior Vice President - Nuclear Operations Georgia Power Company P.O. Box 4545 Atlanta, Georgia 30302

Dear Mr. O'Reilly:

Subject:

Staff Acceptance of Stainless Steel Ties for Use in Vertical Cable Trays for Vogtle Units 1 and 2 (TAC 63584)

By letter dated May 27, 1987, Georgia Power Company submitted its long-term proposal for support of cable in vertical cable trays, i.e., through the use of stainless steel cable ties. The staff has completed its review of l

this submittal and concludes that the use of stainless steel ties to support cables in vertical cable trays is acceptable.

The staff's evaluation is enclosed.

Sincerely, f

OA

.]L VJ Helanie A. Miller, Project Manager Project Directorate II-3 Division of Reactor Projects I/II

~

Enclosure:

As stated l

cc: See next page 1

-t l

4 Mr. J. P. O'Reilly l

Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Comission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel-Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree' Street, N.W.

P.O. Box 2625 Atlanta, Georgia -30303 Birmingham, Alabama 35202 James E. Joiner Mr. Paul D. Rice Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore i

Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Danny Feig Mr. J. A. Bailey 1130 Alta Avenue Project Licensing Manager Atlanta, Georgia 30307 Southern Company Services, Inc.

P.O. Box 2625 Carol Stangler Birmingham, Alabama 35202 Georgians Against Nuclear Energy 425 Euclid Terrace Ernest L. Blake, Jr.

Atlanta, Georgia 30307 Bruce W. Churchill, Esq.

Shaw, Pittman, Potts and Trowbridge 2300 N Street, N. W.

Washington, D. C.

20037 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company Route 2, Box 299-A Waynesboro, Georgia 30830 Regional Administrator, Region II U.S. Nuclear Regulatory Comission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. R. E. Conway Senior Vice President and Project Director Georgia Power Company

^

Rt. 2, P. O. Box 299A Waynesboro, Georgia 30830

_ _ _ _ - _ _ _ _ _