Notice of Nonconformance from Insp on 870824-28. Nonconformance Noted:End Cap Protection Not Installed on Machined End of Guide Tubes Although Sequence Signed Off as Complete on Traveller Es 120-B
ML20236G751
Person / Time
Issue date: 10/28/1987
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20236G740 List:
References
REF-QA-99900002 NUDOCS 8711030261
Download: ML20236G751 (2)


Text

_ _ _ _ _ _ - _

1 l

APPENDIX A J

l Combustion Engineering, Incorporated

{

Docket No. 99900002/67-01 j

NOTICE OF NONCONFORMANCE i

I l

During an inspection conducted on August 24-28, 1987, the implementation of the

)

Quality Assurance (QA) Program at the Combustion Engineering (CE) fuel manu-

{

facturing facility in Windsor, Connecticut was reviewed with respect to the i

fabrication of nuclear fuel assemblies. The applicable QA program requirements i

I are 10 CFR Part 50, Appendix B, 10 CFR Part 21, and CE's QA Manual (QAM), Revision dated May 4, 1987.

Based on the results of this inspection, it appears that certain activities at the CE facility were not conducted in accordance with these commitments.

These items are listed below.

1.

Criterion VIII of Appendix B to 10 CFR 50 requires that identification of l

an item be maintained on records traceable to the item throughout the l

fabrication of the item.

Contrary to the above, Section 8.4.1.7 of the CE QAM, Revision dated l

May 4, 1987, states, in part, that " Traceability when required by l

contract, shall be maintained." This implies an exception if not required by contract.

(87-01-01) 2.

Criterion V of Appendix B to 10 CFR 50 requires that activities affecting quality be prescribed by documented instructions, procedures, or drawings, of a type appropriate to the circumstances.

Contrary to the above, the CE QAM, Revision dated May 4, 1987, does not referenceTemporaryShopInstructions(TSIs)andtherearenodocuments available to describe how to use a TSI relative to the CE QA program.

(87-01-02) 3.

Criterion V of Apperdix B to 10 CFR 50 requires that activities affecting quality be prescribed by documented instructions, procedures, or drawings, of a type appropriate to the circumstances.

Sections 3.2.2 and 4.0 of QC-15-14, " Procedure for Special Procesc Qualification," Revision 1, dated March 18, 1987, requires that MFG procedures inc'lude a list of critical parameters and the range of each and also procedures to evaluate parameters and criteria for results.

Contrary to the above MFG-15-05, " Process Specification for Grinding Pellets," Revision 0, dated Novomber 23, 1971 does not contain parameters or reference procedures.

(87-01-03) 4.

Criterion V of Appendix B to 10 CFR 50 requires that activities affecting quality shall be accomplished in accordance with documented instructions, procedures, or drawings.

$k#h 0

PDR l

t 4

~ Step 4 of.0S 419, " Machine'First End," Revision 2,' dated September.16, 1974,_ requires that plastic protector caps be.placed'on the machined-end of the' guide' tubes.:

Contrary to the above, end cap protection was not installed on'the machined end of guide. tubes although:the sequence had been signed-

'off as complete on traveller ES 120-B. -(87-01-04) 5.-

Criterion V of Appendix B to 10 CFR 50 requires that activities affecting quality shall-be accomplished in accordance.with documented instructions, procedures, or drawings.-

Section 3.11Lof OS 510 " Load Fuel," Revision' dated June 30,'1987,- requires.

that doors:to the stacking'and loading' room be. closed at all times, except for passage in and out of_the room.

Contrary to the above, one door _ to the stacking'.and loading room was proppedopenfor30 minutes..(87-01-05) l

.I q

i I

l 1

-l

._______1.______