Closes Out TMI Action Plan Item II.K.3.5, Reactor Coolant Pump Trip (Multi-Plant Action G-01).Util Addressed plant-specific Info Via Westinghouse Owners Group Methodology Per Generic Ltr 85-12
ML20236D446
Person / Time
Site: Summer 
Issue date: 03/15/1989
From: Hayes J
Office of Nuclear Reactor Regulation
To: Bradham O
SOUTH CAROLINA ELECTRIC & GAS CO.
References
TASK-2.K.3.05, TASK-TM GL-85-12, TAC-56935, NUDOCS 8903230107
Download: ML20236D446 (3)


Text

-_

. March 15,1989 r

1 Docket No. 50-395

' Distribution:

"Deewetfe;}e, ACRS (10) (9/A/2)-

B. Grimes j

Local PDR Mr. O. 5. Bradham PD21 r/f Vice' President, Nuclear Operations S. Varga'(12/D/9) j South Carolina Electric & Gas Company G. Lainas (14/E/4)

)

Virgil C. Summer Nuclear Station E. Adensam (14/H/3)

P. O. Box 88 P. Anderson Jenkinsville, South Carolina 29065 J. hayes j

OGC

-j

Dear Mr. Bradham:

E. Jordan (MNBB3302)

]

SUBJECT:

CLOSE00T OF TMI ACTION PLAN ITEM II.K.3.5, REACTOR COOLANT PUMP TRIP, (HULTIPLANT ACTION G-01) TAC.56935 4

The NRC staff generically approved in Generic Letter 85-12.the Westinghouse-3 i

Owners Group (WOG) methodology for the reactor coolant pump (RCP) trip issue I

defined in TMI Action Plan Item II.K.3.5.. Licensees were required to address i

plant specific information on this item.

The NRC staff's review has progressed j

1 to the point where it can be concluded that the WOG methodology has significantly improved reactor safety and there are no major safety significant

')

)

-concerns for the plant specific information.

In addition, you have adopted and 1

implemented the methodology.

Therefore, the staff concludes that the RCP' trip issue in TMI Action Plan Item II.K.3.5 is satisfactorily resolved and that this multiplant action, G-01, can be closed out.

Sincerely, 4

0$hh P

John J. Hayes, Jr., Project' Manager R

Project Directorate 11/1 P

Division of Reactor Projects I/II Office of Nuclear Reactor Regulation cc: See next page (LTR. T0 BRADHAM FROM HAYES) i iQ A:b{,'1:DRPR LA.

DRPR P

DRPR l

kPAn,p:

son dlm EReeves E

03//6/89 h/89 03/jf/89 c

e

\\

?*

UNITED STATES -

8 NUCLEAR REGULATORY COMMISSION o

5

<j-WASHINGTON, D. C. 20656

% +.... p' March 15,1989 Docket No. 50-395.

t Mr. O. S. Bradham-Vice President, Nuclear Operations South Carolina Electric & Gas Company Virgil C. Sumer Nuclear Station l

P. O. Box 88 Jenkinsville, South Carolina 29065

Dear Mr. Bradham:

SUBJECT:

CLOSE0VT OF TMI. ACTION PLAN ITEM II.K.3,5, REACTOR COOLANT PUMP TRIP, (MULTIPLANT ACTION G-01) TAC 56935 j

The NRC staff generically approved in Generic Letter 85-12 the Westinghouse Owners Group (WOG) methodology for the reactor coolant pump (RCP) trip issue defined in TMI Action Plan Item II.K.3.5.

Licensees were required to address plant specific information on this item.

The NRC staff's review has progressed to the point where it can be concluded that the NOG methodology hes significantly improved reactor safety and there are no major safety significant concerns for the plant specific information.

In addition, you have adopted and implemented the methodology.

Therefore, the staff concludes that the RCP trip i

issue in TriI Action Plan Item II.K 3.5 is satisfactorily resolved and that this multiplant action, G-01, can be closed out.

Sincerely, b

/-

J n J.-Ha es, Jr., Project Manager Project Directorate II/1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation cc: See next page

\\

~

Mr. O. S. Bradham South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station 1

Cc:

Mr. William A. Williams, Jr.

Technical Assistant - Nuclear Operations Santee Cooper P.O. Box 764 (Mail Code 153)

Columbia, South Carolina 29218 J. B. Knotts, Jr., Esq.

9 Bishop, Cook, Purcell and Reynolds 1400 L Street, N.W.

i Washington, D. C.

20005-3502 i

Resident Inspector / Summer NPS c/o U.S. Nuclear Regulatory Commission Route 1. Box 64 l

Jenkinsville, South Carolina 29065 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Chairman, Fairfield County Council P.O. Box 293 Winnsboro, South Carolina 29180 Attorney General Box 11549 Columbia, South Carolina 29211 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health j

South Carolina Department of Health

{

l and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 South Carolina Electric & Gas Company Mr. A. R. Koon, Jr., Manager l

Nuclear Licensing l

Virgil C. Summer Nuclear Station P. O. Box 88 Jenkinsville, South Carolina 29065 l

l l

..~