Jump to navigation Jump to search
Forwards Zion Generating Station Unit 1 Steam Generating Station Activities Special Rept,Steam Generator Eddy Current Testing,Steam Generator Tube Plugging,Steam Generator Sleeving for 1986 Outage
ML20236B879
Person / Time
Site: Zion File:ZionSolutions icon.png
Issue date: 10/15/1987
From: Rieck T
COMMONWEALTH EDISON CO.
To: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20236B884 List:
References
NUDOCS 8710260389
Download: ML20236B879 (1)


Text

--

DMS PRICRITY ROUTIWG C mm:nw:alth Edis:n r,f Zion Gensrating Station f

l SPDEL 101 Shiloh Blvd.

p-I Zion, Illinois 60099 N dp- -% '*"-

Telephone 312/746-2084 M

i, E>T nu r

P u f1Lh -

l October 15, 1987 l

Mr.

A.

Bert Davis g

)

Regional Administrator a

Office of Inspection and Enforcement R

c-Region III F')

U.S.

Nuclear Regulatory Commission

@ ib

> a?

Glen Ellyn, Illinois 60137

Dear Mr. Davis,

,,p ue This is to inform you that the enclosed Steam Generator-Activities Special Report for the 1986 Unit One Refueling Outage fulfills the reporting requirements of Technical Specifications 4.3.1.B.5 and 6.6.3(k).

If there are any additional questions, please contact i

Mr.

R.

Sumners of the Zion Station Technical Staff, extension 341.

1 Sinc rely, i

/

,s?

A. Rieck i

Superintendent, Services Zion Station l

TAR /RLS/lsw cc:

R.

Cascarano/L. Laspisa'(w/o attach.)

M. Madigan (with attach.)

R.

Sumners (with attach.)

C.

Schultz (with attach.)

H. Holzmer (w/o attach.)

l P.

LeBlond (with attach.)

R.

Cole (with attach.)

R.

Tamminga (with attach.)

J.

Blomberg (with attach.)

. Master File I

l l

8710260389 871015 PDR ADOCK 05000295 PDR R

.gggg I I J.6 0 l -

- _ -