Special Rept 87-11,reporting Number of Tubes Plugged During Third Steam Generator Tube Inservice Insp.Eight Tubes Plugged
ML20236A893
Person / Time
Site: Callaway Ameren icon.png
Issue date: 10/15/1987
From: Blosser J
UNION ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
87-11, ULNRC-1651, NUDOCS 8710230217
Download: ML20236A893 (2)


Text

_ _ _ _ _ _ _ _ .

UNION Etscraic g-USNRC-DS' October 15, 1987 cuaway Put 1710C122 A D 02 U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 ULNRC-1651 Gentlemen: l DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 FACILITY OPERATING LICENSE NPF-30 SPECIAL REPORT 87-11 NUMBER OF TUBES PLUGGED DURING THIRD STEAM GENERATOR TUBE INSERVICE INSPECTION This Special Report is being submitted in accordance with Technical Specification (T/S) 4.4.5.5.a which states:

"Within 15 days following the completion of each inservice inspection of steam generator tubes, the number of tubes plugged in each steam generator shall be reported to the Commission in a Special Report pursuant to Specification 6.9.2."

The Third Steam Generator (S/G) Inservice Inspection was completed for S/G's 'A' and 'D' on 9/30/87 to meet the surveillance requirements j of T/S 3/4.4.5, " Steam Generators." The plant was in Mode 6 - Refueling i for Callaway Plant's Refuel-II outage. Eight tubes were plugged as a  !

result of the inspection and are identified below:

S/G 'A' S/G 'D' Row Column Row Column 3 44 46 72 51 60 56 81 17 55 33 12 43 21 47 86 8710230217 871015 PDR S

ADOCK 05000403 PDR

(([

D. Blosser Manager, Callaway Plant R / :jl1 cc: Distribution attached hy Maky Aadress P.O. Box 620. Fulton. MO 65251

L .-

cc distribution for ULNRC-1651' Mr. Paul O'Connor (2 copies) ~ Manager, Electric Department Office of Nuclear Reactor Regulation Missouri Public Service Commission U.S. Nuclear Regulatory Commission P. O. Box 360 Mail Stop P-316 Jefferson City, MO 65102 ,

7920 Norfolk Avenue  ;

Bethesda, MD. 20014 Mr. O. Maynard Wolf Creek Nuclear Operating Corp.

Mr. A. Bert Davis P. O. Box 411 Regional Administrator Burlington, KS 66839 U. S. Nuclear Regulatory Commission  ;

Region III Mr. Merlin Williams 799 Roosevelt. Road Supt. of Regulatory Quality &

Glen Ellyn, IL 60137 Administrative Services Wolf Creek Nuclear Operating Corp.

American Nuclear Insurers P. O. Box 411 c/o Dottie'Sherman, Library Burlington, KS 66839 The Exchange. Suite 245 270 Farmington Avenue I Farmington, CT 06032 Records Center Institute of Nuclear Power Operations Suite 1500 1100 Circle 75 Parkway Atlanta, GA 30339 NRC Resident Inspector D. F. Schnell (400)

R. J. Schukai (470)

G. L. Randolph J. F. McLaughlin J. E. Davis (Z40SR)

(Z40SR) (w/c)

D. W. Capone /R. P. Wendling (470)

F. D. Field (480)

A. P. Neuhalfen A. C. Passwater/D. E. Shafer/D. J. Walker (470)

) G. A. Hughes Z40.03 (QA Record)

J. M. Price R. D. Affolter M. E. Taylor H. Wuertenbaecher, Jr. (100)

S. L. Auston (470)(NSRB) i S. J. Bellers/J. D. Schnack JDB Chrono i

3456-0021.6

! 3456-0260 Z40ULNRC C56.37 N. Date (Sandra Auston) (470) i i