Forwards Amend 28 to License DPR-21 & Safety Evaluation. Amend Clarifies Info Re Insp Intervals & Establishes Criteria for Snubbers That May Be Exempted from Being Counted as Inoperable
ML20236A802
Person / Time
Site: Millstone 
Issue date: 03/08/1989
From: Boyle M
Office of Nuclear Reactor Regulation
To: Mroczka E
NORTHEAST NUCLEAR ENERGY CO.
Shared Package
ML20236A803 List:
References
TAC-71051, NUDOCS 8903200173
Download: ML20236A802 (3)


Text

., _ - _ -

6-d.

i March 8, 1989

]

Docket No.'50-245 Mr. Edward J. Mroczka

' Senior Vice President 1

Nuclear. Engineering and Operations l

Northeast Nuclear Energy Company i

P. O. Box 270 Hartford, Connecticut 06141-0270

Dear Mr. Mroczka:

SUBJECT:

ISSUANCE OF AMENDMENT (TAC N0. 71051) a The Commission has issued the enclosed Amendment No. 28 to Facility Operating License No. DPR-21 for Millstone Nuclear Power Station, Unit No. 1, in response to your application dated October 13, 1988.

The amendment will revise the Technical Specifications to provide clarifying information for determining required inspection intervals and establishes criteria for snubbers that may be exempted from being counted as inoperable.

A copy of the related Safety Evaluation is also enclosed. The notice of issuance will be included in the Commission's bi-weekly Federal Register notice.

Sincerely,

/s/

Michael L. Boyle, Project Manager Project Directorate I-4 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Enclosures:

i 1.

Amendment No. 28 to DPR-21 2.

Safety Evaluation cc w/ enclosures:

See next page

'LA:PDI-4 PM:PDI-4 PD:P

-4 OG S

MBoyle:Im JSto z b

02/AA/89 02/j3/89 02/

89 0J/.,/89 i

p\\

8903200173 890308 PDR ADOCK 05000245 dg p

PDL.

\\

y

E' [ '

.,,,f x

j i

. AMEN 0 MENT NO. '28 - TO FACILITY-0PERATING LICENSE N'O..DPR-21 R

DATED:: MARCH 8,J19891 yenM'imF## '

j NRC PDR Local PDR Gray File.

S4 Varga(14E4)

B. Boger (14A2)

J. Stolz-

- S. Norris M. Boyle OGC D.Hagan(MNBB13302)

E. Jordan (MNBB3302).

B. Grimes (9A2)

' T.' Meek (4)(P1-137)

W.' Jones (P-130A).

E. Butcher-(11F23)

- j ACRS-(10) ni

- GPA/PA ARM /LFMB-

-l t

m-m.______________m._._m.__.__

_____m_____m_

. _-.m_____.

__m__

,.____m ma

i S

1 Mr. Edward J. Mroczka Millstone Nuclear Power Station Northeast Nuclear Energy Company Unit No. 1 cc:

Gerald Garfield, Esquire R. M. Kacich, Manager Day, Berry and Howard Generation Facilities Licensing Counselors at Law Northeast Utilities Service Company City Place

. Post Office Box 270 Hartford, Connecticut 06103-3499.

Hartford, Connecticut 06141-0270 W. D. Romberg, Vice President D. O. Nordquist.

Nuclear Operations Manager of Quality Assurance Northeast Utilities Service Company Northeast Nuclear Energy Company Post Office Box 270 Post Office Box 270 Hartford, Connecticut 06141-0270 Hartford, Connecticut 06141-0270 1

Kevin McCarthy, Director Regional Administrator i

Radiation Control Unit Region I I

Department of Environmental Protection U. S. Nuclear Regulatory Commission State Office Building 475./.11endale Road Hartford, Connecticut 06106 King of Prussia, Pennsylvania 19406 Bradford S. Chase, Under Secretary First Selectmen Energy Division Town of Waterford Office of Policy and Management

-Hall of Records 80 Washington Street 200 Ba ton Post Road i

Hartford, Connecticut 06106 Waterford, Connecticut 06385 4

S. E. Scace, Stat. ion Superintendent W. J. Raymond, Resident Inspector Millstone Nuclear Power Station Millstone Nuclear Power Station Northeast Nuclear Energy Company c/o U. S. Nuclear Regulatory Commission Post Office Box 128 Post Office Box 811 Waterford, Connecticut 06385 Niantic, Connecticut 06357 J. P. Stetz, Unit Superintendent Millstone Unit No. 1 Northeast Nuclear Energy Company Post Office Box 128 Waterford, Connecticut 06385 j

l l

_-