{{#Wiki_filter:? usen. sen! Portland General BechicCoirvoy I E: David W. Cockfield Vice President. Nuclear October 2, 1987 Trojan Nuclear Plant Docket 50-344 Licenso NPF-1 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555

Dear Sir:

Response to Roquest for Additional Information License Change Application 150 By your letter dated July 28, 1987, Portland General Electric Company received a request for additional information on License Chango Appli-cation 150. This proposed license change would reviso Trojan Technical Specification surveillance requirements for safety injection accumula-tor isolation valves. Attached is our response to your request. Sincerely, y, AW / Attachment c: Mr. John B. Martin Regional Administrator, Region V U.S. Nuclear Regulatory Commission Mr. R. C Barr Resident Inspector Trojan Nuclear Plant Mr. David Kish, Director State of Oregon Department of Energy Mr. Michael J. Sykes Chairman of County Commissioners 8710090227 871002 PDR ADOCK 05000344 i P PDR 121 S W Edmon SDwt. Po1 and Oregan 97200

N '?- I Trojan Nuclear Plant. Document Control Desk Docket.50-344 October 2, 1987 License NPF Attachment Page 1 of 4 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION LICENSE CHANGE APPLICATION 150 Information Request #1 Provide an electrical schematic and description of the: lockout feature on the accumulator isolation valve control room switches referred to in your January 20, 1987 letter.

Response

Figures 1 and 2 of the electrical control. schematic diagram for the " Accumulator Tank 1 Outlet Isolation Valve MO 8808A" (Scheme #AB2510) are provided on Pages 3 and 4 of this attachment. These figures illustrate the operation of the combination valve control switch / lockout switch as it will function upon installation. Referring to Figure 2, the switch has a normal, open, and close position with a spring return to normal. The switch handle is rotated clockwise to 1 open the valve and counterclockwise to close the valve. When the valve is fully open, a red indicating light is lit. When the valve is fully closed, a green indicating light is lit. The valve switch is placed in i lockout by pulling out on the handle when in the normal position. Once in lockout, the handle cannot be rotated in either direction. Referring to Figure 1, pulling out the control switch (42-2510) to the lockout position opens contact between F1 and F12 and between F7 and F6. 6 This deenergizes the open and close control circuitry and electrically prevents valve movement (in addition to the mechankcal restriction of the handle when in lockout). Information Request #2 Provide a description of the proceduro you intend to use to accomplish the' proposed surveillance requirement (4.5.1.C) to verify that power to the isolation valves operator is disconnected. This is the procedure that would involve the use of the lockout feature on the accumulator isolation valve control room switches.

Response

Trojan Nuclear Plant Periodic Operating Test POT-2-3, Emergency Core Cooling System (ECCS) Valve In-Service Test, is the procedure which will be used to accomplish the proposed surveillance requirement (Trojan Technical Specification 4.5.1.C). This POT provides instructions for j performing monthly valve positions and breaker and power lockout switch positions during Modes 1-4 for those ECCS valvec listed on data shoots attached to the procedure. The accumulator isolation valves, MO 8808A-D,

t c' Trojan Nuclear Plant Document Control Desk Docket 50-344 October 2, 1987 License NPF-1 Attachment Page 2 of 4 are included on the list of these valves requiring monthly checks. The data sheet will require two checks for each isolation valve. The first will verify that the valve is in the open position when Reactor Coolant System pressure is greater than 1000 psig by checking control room indication. The second will verify that the control switch is in the lockout position with the blocking collar installed. DLN/kal 6037k.987 l l

7 C% h-Trojan Nuclear Plant t Docket 50-344 9 License NPF-1 lE 4-u Vl 1 .} ; 4 ;. ] j.. B 4 4 g

i L

CONTROL U LOCKOUT OPEN REMOTE AUTO -. LOCAL 1 ~ T T SI .t. SI E 'ONBLOCf X --~C PRESSURE }. l 480V MCC No.023 g23 _Aze5 BKR.No.52-2510 ~ X" je A 3F is ZS8808A ZS8800A 5 bc l SQ.l A g l II ti X g

2510XF ::2510XR DGM C

8 N ",42(.25!0 M88884[bo ZS8808A en e o 4 -- ;g K nao y 27 COPJTWCT Of6*D Alf5 k ) 9KR. NO. )) E%lf W W 5.w itc H 2F ) nerNote a $333 m 8F8 gavveo our 2F 1R1my Q 488-129V $$2 ( $2-2510 cio .- CS 42-2510 ipois l. Ll> L2) n.3) I g,$ CS

E y C,jJA 2FA I

f E @n D F F F RT "" " 7

      • ' d'*"

l '^ Y 1 i!**28 ~ ~ ~ I OPEN IF IF l-l$ A, gg f f.22 PRESSURE 49 SIGNAL 65) 22510XF o EE)n30 couracy o pgrus j A B C A B C [ GLM }F8"42-2MO ~ d' d 'M

    • en H

"'V D' E l f f f azg5 E25 ELA CS # ""#D o u T~ L d d AM8se8A _fg i 7-l ff49 ACCUMULATOR TANK 1 OUTLET ISOLATION VALV

f49 SCHEME 'AB2510, S/U 19.5 S/UMOTOR DESCRIPTION SCHEME MG No.

HP No. g l 52 i 11.5 ACCUM. TANK 1 OUTLET ISOL. VALVE M08800A AB25tB B25 59 34 36

n 8 3 18 52 '

11.5 ACCUM. TANK 2 OUTLET ISOL. VALVE N088888 882610 826 @ j 52 19.5 ACCUM. TANK 3 OUTLET ISOL. VALVE M08800C AB25tl B25 52< 52 19.5 ACCUM. TANK 4 OUTLET ISOL. VALVE M088000 902611 B26 52< I h L......

Document Control Desk October 2, 1987 M Attachment ""8* 3 ' ' APERTURE CARD Also AvaHable On Aperture Card l I INDICATION l. CLOSE OPEN CLOSE ALARMS REMOTE LOCAL _ IREMiLOC5 !REMa_ LOC-LIGHTS I l STATUS .t ANNUNCIATOR a a.. r T l-l i ZS8808Ad Mfs t' i;f ZS8808A 7;!ZS8808As ZS8808A o 0 J J ] H8808A y M8606A bo CC 00 e 3R 30 ACCUM. TANK l ACC. TANK i .I N88eh 8IEE k 8 ZEE k NI F' j EN RR 3R 30 E-1835.1836 (gE-1544 1 H5.) 1 .aza5 t e25( 825 { M m x G12e S _C129 AUXILIARY RELAYS 2510xF. 251eXR o CONTACTS DwG.No. CONTACTS DWG.No. ] g4 g; g: ) (13 9 2 *--l He THIS DWG. le---l H F SPARE 42-2510 0E si CS gg39 NOTES: ) "D8 Elld{ t. CONTACT CLOSES ON SAFETY INJECT! Ort 1, 2. VALVE SHOWN IN FULLY OPEN POSITION. j IR. IRA Q.) J 3. FOR SCHEMES A82510 & AB251 PULL g,,.' IF. 2FA tkl t:. VIRES TO,G1IA & WIRE INTERNALLY TO $13A.

K603 IF. 2F (F) th FOR SCHEMES BB2618 & 8B2611 PULL WIRES TO g (NOTE di (13g.

M 4. CONTACT OPENS ON SAFETY INJECTION, I O 5. CONTACT CLOSES AT AND ABOVE P1), LOW-(l.ZQ .4y - IF R, PRESSURIZER PRESSURE. , R,. 3R' B25 I 9 6. FOR SWITCH DEVELOPMENT SEE FIGURE 2. x.2F.2R.3R. % Y D REFERENCE DRAWINGS: 2510XR t q A. B. C (A) s 1. SCHEME E-582 l' lAM l 2. P & ID M 296. 3. V.P. MIT(4)-23. q^x. 2F. 2R. 3R, n 3- (C) t ^'" g1 tooc 02g7-O IM8909^l M08808A rR0;AN ANEAR PLANT """E* M E lOff I 8 WJ ADAPTER TABLE PORTLAND OREGON iH

  • S St.

CK Dam 6 -7 h -d fDfy i W 2 .CO"g gL 3 0 dTS LOCATION glLig ,,,,,c ,,,gL,, g y, dy2 plt Q"gQ"M (y* g C.12A.Els (1% 95 eleg.MeseeA2tiexr.25 oxR (Mum. s. to swssw l ISSUED FOR LCA-I pdc e4-t21 b y4p Q"gg "j*g g "j g . tis. tis. 85 ELej. Mesees esiexr.2stexR y gggg ggg g ) 42 g511 %'*g QM g 'j#M C17A. C19A. 51% B25, ele} M0808C2511xF. 2511xR SAFET NJ CT10N g 9 2yn '*gsy"g g.," 'M .tLM.Gis.gs ggj Meee80 2stixr.2stixn 4 gj 1 m n, mv

N p. , w.. Trojan Nuclear Plant Docket 50-344. License NPF-1 i: i CONTACTS HANDLC l Muett Do intan vite 8 ROTARY CONTACTS (NO CHANGE l. ON HANDLE PULL-0UT) opsm c = at mit au All-Bil A12-912 2 si sit sti Al Bt X A7 as as A5-85 AG-86 8 e7 as es A7 87 X ci car en Cll-Dil C12-012 3 os oir on Cl-Dt X = c7 cs cs C5 05 l C6-06 8 07 os os C7-07 X PULL-0UT CONTACTS (NQ CHANGE ON HANDLE ROTATIONI ouf UH ptir ,tn E12-El X Fl jprit,rn Fl2-Fi e ~ E7e--j H *** E6 E7 X "e-{ Hrs ,rs F6-F7 l CONTROL, 42-251$ SWITCH CS W 42-25M l. }!{ CS l 3 WESTINGHOUSE Tt l g% a STYLE NO.3627A2 j' (NUCLEAR CLASS ; j-, SPRING RETURN V l PULL-0UT IN NTJ P!STOL GRIP HAM m,,,. LOCATION: CISA, @ l v c_, ~

Document Control October 2, 1987 j Attachment { Page 4 of 4 ) 4 l 1 I 'OSITION ? CLN 1 -X M e X = X = N_0TES: @ @ AND REFERENCE DRAWINGS l' a X T1

i YERTGd 42-2610 CkNO CS 42-3611 n

CS $efn Also Available Gu 2 h fNORMAL Aperture Card "I lAL ONLY l Mk O M N - D b _ TROJM NUCLEAR PLei " ET E rs;,e 2 M TL* c w oon an. 8-2889 "" 3 "2 eve onc twin M e & LC A-lGo ( A/oTT4_Mf 5"'2"Oj ISSUED FOR e SCHEMATIC DIAGRAM SAFETY INJECTION SYSTEM VALVES i ~ h_ '-}}