l M @Orm N4

-l O u.s.~uc'e aeeut ro vco testo~ O '

l l

W so MATERIALS LICENSE Amendment No. 03 l

Pursuakt to the Atornic Energy Act of 1954, as amended, the Eneigy Reorganization Act of 1974 (Public Law 93-438), and T l Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations 1

I heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, j

source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This i

license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is ;

subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any !

i conditions specified below.

J t

i Licensee l

In accordance with letter dated i

3. gecember {2,1986,,

I' cense numb Allegheny Health, Education &

SNM-1381 is amended in l

Research Corporation its entirety to read as follows:

l 2.

320 East North Avenue l

Pittsburgh, Pennsylvania 15212

4. Expiration date October 31, 1988 j

5.. Docket or I

I Reference No.

070-01395 I

j 6. Byproduct, source, and/or

7. Chemical and/or physical
8. Maximum amount that licensee

.j special nuclear material form may possess at any one time j

, under this license l

l A. Plutonium (Principal A. Sealed Source (s),

A. 6.0 grams (15 individual l

j radionuclides PU-238) sources not to exceed 1

400 milligrams each)

I i

l 'l k

l 9.

Authorized use Ii j

A.

Implantation in dogs for testing of nuclear powered cardiac pacemakers.

i i

i

,l CONDITIONS

!1 y"

l10.

Licensed material shall be used only at Allegheny Health, Education & Research j

i Corporation, 320 East North Avenue, Pittsburgh, Pennsylvania.

l l

11.

Licensed material shall be used by, or under the supervision of, George Magovern, M.D.

L d 12. A(1) Any sealed source (s) or detector cell (s) specified in Item (s) 7.A.

l shall be tested for leakage and/or contamination at intervals not to j

exceed 6 months. Any source or detector cell received from another i

i person which is not accompanied by a certificate indicating that a test i

q was performed within 6 months before the transfer shall not be put into jl D

use until tested.

l d

j j

(2) Notwithstanding the periodic leak test required by this condition, any i

l licensed sealed source or detector cell is exempt from such leak tests

!. l l

1 when the source or detector cell contains 100 microcuries or less of beta j

and/or gamma emitting material or 10 microcuries or less of alpha emitting l

E material.

l 1

S 8707210304 870305 9

REG 1 LIC70 SNM-1381 PDR i

I lL "0F C L ECORD COM" h

g _1 8 q

i h-e---- www.m wwrv,ww=vwwwwwwysirgrarwww,,cwwwwwwwwwwwgr,www l

____-________-_____O

my -

na-~w y

l

. C Forem 374A U.S. N R CEfULATORY COMMISSON pggg 9 ap 9

pggg3 l

Lkean aumber I

MATERIALS LICENSE N -1"!

SUPPLEMENTARY SHEET I

n7n_ni tos; l

i a-Wt h 0?

l (12. continued)

CONDITIONS I

B.

Any sealed source or detector cell in storage and not being used need I

not be tested. When the source or detector cell is removed from storage I

for use or transfer to another person, it shall be tested before use or l

transfer, i

l C.

The test shall be capable of detecting the presence of 0.005 microcurie I

of radioactive material on the test sample.

If the test reveals the I

presence of 0.005 microcurie or-more3of-temovable contamination, the I

source or detector cell shalJJe' removiidQFqmpsprvice and decontaminated, l

l repaired, or disposed of in accordance wit 1T6mnission regulations. A i

l report shall be file (pithin 5 days of the date'ty(leak test result is l

l knownwiththeU.E.)uclearRegulatoryCommission, e)ionI, ATTN:

Chief, R

Nuclear MaterialsJafety and Safeguards Branch, 631 Ryk Avenue, King of i

Prussia Pennsvivagia 19406. The report shall specify p source involved, the test resull:s, and corrective action taken.Jetords of leak test l

results shal - '

kept in i

heComm(1'gqqsofmicrocurieQpdjshallbemaintainedfor ssion.1 Records may46 Titrposed ofgliowing inspection by l

2 Commission in'spection.

D.

Tests for leakage and/or contamination 1shall be performed by the licensee N

ment State to perform such~4)b licensgy% gossissiqn or an Agree-l or by otheripersongspecif1 ssrv ifiis~.""

y y

E.

Notwithstanding the other provisions of this leak test condition, leak tests are not required or pacemakers 11mplanted in experimental animals provided that N

a leak test shall, be performed immediately,following removal of the pacemakers h

l from the animal.

c

/f, p

The licensee may transport licensed material in accordah(ce,with the provisions 13.

y of 10 CFR Part 71, " Packaging and Transportation of Radioactive Material".

W W

14.

Except as specifically provided otherwise.inithis license, the licensee shall l

conduct its program in accordance with the statements, rs^ presentations, and i

y procedures contained in the documents including any enclosures, listed below.

y The Nuclear Regulatory Commission's regulations shall govern unless the state-l'

{

ments, representations and procedures in the licensee's application and corre-F spondence are more restrictive than the regulations.

l A.

Letter dated June 28, 1978 l

B.

Letter dated December 22, 1986 y

N For the U.S. Nuclear Regulatory Commission Date By h A4M6 h l

Nuclear Materials Safety and l

Safeguards Branch, Region I

)

King of Prussia, Pennsylvania 19406 l

I mww-------------- ---- ---- ----- ---w - -- --- - - ew immummuiEins w = =d