l i
Form oEC-313 UNrtED STATES ATOMIC ENERGY COMMI55 ION ioCil'30-APPLICATION FOR BYPRODUCT MATERIAL LICENSE OD #-==n INSTRUCTIONS -Cofr.ptete items 1 tHough 16 if this is an mitral apphcotion or an apphcation for renewal of a heense Information contained m pre-vious apphes00ns foeff we the Co emession with respect to items 8 through 15 may be mcorporated by reference provided references are clear and specifre Use %fsplemer'ai theets where necessa y item 16 must be completed on all appbcatsons Mail two copies to U S Atomic Energy Commis-sion Washmaten. O C 2"'15, Attention-Materiais Brance. Directorate of Licensmg upon approval of this appheation, the apphcant will receive an AEC Byproduct Ma'enat Licene An AEC Byproduct Matenal License is issued m accordance with the general requirements contamed m Title 10, Code of Fed-eral Regulatsorm. Part 30 saff the Licensee is subject to Title 10. Code of Federal Regulations. Part 20. and the beense fee provisions of Title 10. Code of Federal Regulations. Part 170 The beense fee cateoory should be stated m item 16 and the appropriate fee enclosed (See Note m Instruction Sheet).
- 1. fo) NAME AND STFIEET ADDntSS OF APPLICANT restitution. arm nosperal per-tb) STREET ADDRE5Nf5) AT WHICH BrPRODUCf mAf TRIAL w LL 8E USED (if son. etc Include ZIP Coce and resophone numoerI d,Merene from Ftop onetude ZIP Code J Washington Gas Light Company Materials Testing Laboratory SAME 6801 Ihdustrial Rd.
Springfield, Virginia 22151 2 DEPARTMENT 70 USE SYP90DtiCT MATERIAL 3 PREYlOU5 Lth5bMERf 5).
fif thes es on appl # cot on for rene.al of a ferenw.
pleone mdwoar and gave wber)
I i
Materials Testing Laboratory None l
I t INDivlDU AL 05IR(5)
(Nome and title of ind... dual (s) ho..lf use or d,recter
$ RADIAflON PROTECTION OFFICER. (Nome of per en desegnored as rodecison proreb supemse use of byproduc morer>ol Gnve tremeng and emper**nce m items 8 and 9 )
t'on oWrer af other then mdevedual user Arrock resume of has trommg and esperserwe os m hems 8 and 9.)
Karl M. Gunther - Manager Ulysses Reed - Sr. Mat. Test. Tech.
I Frank C. Parker - Sr. Mat. Test. Tech,. l Charles N. Wientjes - Sr. Mat. Test.
i Tech.
I e (o) StPRODUCT marERIAL. (f hmen's
' tb) CHEmlCAL AND/OR PHY5fCAL FORM AND MAXIMUM NUM6ER OF MILLICURIES OF E ACH CHimiCAL AND/OR PHYS-ond moss viumber of each j l
l CAL FORM THAT YOU wtLL POSSESS Af ANY ONE Timt. (if womd source (s), osso sto*e mome of manufuceprer, mocet number, j
number of sources and monimum actevetr per source )
Pu 238 30 millicuries - Sealed Source (Texas Nuclear Model 50-572428)
I i
3 millicuries - Sealed Source (Texas Nuclear Model j
Cd 109 i
696-696782)
,i LC3 n wm r. -
....g---
P f,W[h +hl s.
i-l w
wh& T f whW-.-
- 7. Df 5CRl8f PURPOSE fos wHICH SYPff0 DUCT MAf(RIAL WILL SE USED. fif byprodurf matereel es far " human use." supplement A (form AfC 313a) must be compie'ed
,... of,h m.
,, b,,,ed.,< mo,er,o,.s m,,,e,o,m of a seu.o-.. monde ue end,,eod.wm.ber m.,6,o,.s,e,o,,,,,,,e, or.de o, e.
4 mh.a,,m soume..,,
- b. n.d o,,dior v d )
Two each Texas Nuclear Model 9256 Source holders. The instrument will be used for elemental analyses. The instrument head provides adeouate shielding for the contained radioactive source and no additional storage contain-er is necessary.
The carrying case provides additional protection for the instrument.
The device will be used throughout the States of Virginia and Maryland and the District of Columbia.
Permanent storace will be at Springfield, Virginia.
8707210244 a70316 REC 2 LIC70 SNM-1712 pg i
iC.n,m..d.n..e.,s.
e.de,
e'
~
Pogs two TRAINING AND EXPERIENCl OF EAcH INDIVIDUAL NAMED IN ITEM 4 (U e.opeis.ea'of bu's ni asce..o,r) lON OF ONTNtJOB f FORMAL COUR51
- 8. TYPE OF TILAINif.eO DutAf,yigg WHtat TRAINED ggg gc,,,3,,,,,,,j gg,,,,,,,,,,,,
e- -
o Pemcipin ond p,.cht..
of r.diohon y,
y, y,
g,
,,0 ci.aa We shall follow the instructions
- b. Red.ooch.dy me..v,.a.nt.*ondo,d.so-e.on enti.oad.,eng technique, and en.
Ye.
No Ye.
No concerning handling and use of
- c. Mome at c..ad c tsut.hoa. bo..c e. m.
the instrument given by the
..e. a d....,,.... s,. d.....d, '
s a. i.....i e u.. a,od.o,,o.
manufacturer.
Na a
- 9. (KPititNCE WITH RAQl AflON
( Actual we of rod.0,lofopes or et,W,.oleaf.sp.,s.nt.1
)
150foPt mAxiaum AMOUNT wMitt ExPtaltNCE W AS GAINED l
DURATION OF EXPititNCE TYPE OF USt i
Same as item #8 l
- 10. RADIATION DiftCTION INSTRUMENT 5 fUm.upple afel.hn'.,I mete..ory )
TYPt OF INSTRUmtNT$
Num4tf RADIA? TON 5tN5fflVffY llANGt WINDOW THICKNESS USE padude
.e ad oet a.be, of.ach)
Av All48Lt D171CfID f or h )
t gic.')
- Monar.,,ag, s,versag.
e.svr.ng; v
t l
l No additional instruments tre required to process or utilize this analyzer.
I i1. MtfMOD, FREOUf NCY, AND $f ANDARD5 USED IN CAlttenflNG IN57RUutNf5 LilitD' ABOvt Hene required, t2. Fila BADGt1. DO5imittt1. AND l'O ASSAY PaOCf Dutt5 V't0 (Fo, F.h boog.s..pe :Jr em.d of cobb,. hap.as p,me...ng,., a..e of.appi.., )
None required. See attached sheet.
INFORMATION TO SE SUSMITTED ON ADDITIONAL 5HEET5 IN DUPLICATE is eACRifits AND tOUIPutNT, D..c.,b.1.b...'.,y 4.cil.rin.nd
....*e hondieng.qvip.eet..t...g. cont in.r.,.hielding, f em. h..J.,.st.
E.p..e.to,y.ke'ca s
a,.,...
4.
(C,m.o
)
v..
N.
See attached sheets.
i... ADiATiON nOTtCTiON nOGa AM.
D......h........,,.......,,....io.........e.
n.,,i.h.........i.4.........4.....
..,,m.o..h....,,i6ie...,....,........e,,,i.w6............e.,,.a.,.........e,.e.............+
............-,,e.h.....
See attached sheets.
i5 wA5ei DISPOS Ai w o u m..... i....e.... e
........i....,,m,.,,,,,,,. a..
,. O.......... ci.e.,i.,.......h o.....
.a..h h. ii b.,,,,4,.......s..e........,..,0s.,y,...........h.,,....i.
See attached sheets.
CERTIFICATE (This item must be completed by applicentl THE APPLiC ANT AND ANY OiFiCIAL EXf CUflNO THIS Ct#fdlCAft ON lt MALP OP TMt APPLICANI N Amt0 IN If tM t. CittiPY TH AT l6 PatP arf D IN CONFOamity wifM fiftt 10. CODE Of FEDERAL 8tGutatiONS. P Aaf 30. AP D TH AT ALL IN.ORMAflON CONTA8NED MtattN. #NCLUDiNG AN.
SUPPLimtNf 5 Aff ACHED Mtatto,15 f aut AND COAktCT TO TMt st1T 07 Ove KNOwLtDGE AND 6tLitt wa" '" ca*oa R i,g.....,....,,,,,..i n %[?ll JdI
'"'a*'*""-
a n,,,
02/10/87
%~~
ild2 Td:
v..i..e e,..
i, o..
/
n waamNo._ i s u 5 C.. sui..
i DD i, Aci s >.. 2 5, i v. s. 6 2 s.. 74 9..o6.. d o
.....oi.ei.a.....o....aissi, ioi.....
e.pte at.te.n.o any dopo,tment ce o.nt y of th. Und.d Sect.. a. to ony mon.e within so..ve..d.stion
..~
1 ADDENDA FOR MODEL 9200 SERIES Item 12:
"No additional personnel monitoring devices are required due to the presence of this instrument.
These source housing (s) are designed such that it is unlikely that any person, during normal usage can receive an exposure in excess of.0.125 rem per year, and the surface radiation levels are all less than 1 mR/hr."
Item 13:
" Adequate protection is provided by the shielding incorporated in the instrument and source holder.
The shutter will move into the " CLOSED" position at such times as the device is not in a measuring position. The instrument will be secured when not in use to prevent unauthorized access to the source."
Iten,14:
"The radioactive source (s) used in Model 9200 Series will be periodically leak tested at intervals not exceeding six months in accordance with Texas Nuclear Procedure QT/25. The AM-241 stabilizer source, if incorporated in this instrument, will not be leak tested. Maintenance and repair will be done by Texas Nuclear and we will follow Texas Nuclear protection procedures."
Item 15:
"No waste disposal is involved.
In the event that the instrument or source use is discontinued, the device will be returned to Texas Nuclear for removal of the radioactive materials."
i i
i i
l j