ML20235M214

From kanterella
Jump to navigation Jump to search
Informs That Region IV Completed Review of Emergency Plan. Emergency Plan Changes Do Not Appear to Decrease Effectiveness of Facility Emergency Plan.Lists Areas Clarified & Better Defined in Rev 11 to Plan
ML20235M214
Person / Time
Site: Waterford Entergy icon.png
Issue date: 07/13/1987
From: Gagliardo J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Dewease J
LOUISIANA POWER & LIGHT CO.
References
NUDOCS 8707170109
Download: ML20235M214 (2)


Text

1:

n+.

JUL 131987 i

In Reply Refer To:

Docket: 50-382 Louisiana Power & Light Company ATTN: J. G. Dewease, Senior Vice President Nuclear Operations 317 Baronne Street New Orleans, Louisiana 70160 Gentlemen:

The Region IV staff has completed review of the emergency plan changes which you submitted to this office by letter dated June 26, 1987. The emergency plan changes do not appear to decrease the effectiveness of the Waterford 3 Emergency Plan. The following areas were clarified and better defined in revision 11 to the Emergency Response Plan.

  • Under definitions 1.1.17, Emergency Coordinator, you included 0FF-SITE notifications.
  • Section 3.1.2.1 Emergency Coordination On-Site, you added full authority and responr.ibility. 1 l
  • Section 5.1.2.2.2, third paragraph, off-site notifications were added to l of f-site protective action recommendations.
  • Section 6.6.1.1.b Accountability, paragraph 2 states accountability is  !

performed by procedure for each facility's personnei. It is evident from review of personnel task assignments for the control room and the TSC that personnel have been assigned responsibility for accountability.

l

  • Section 5.1.2.3.1.a.6., included making off-site notifications.

If there are any questions in regard to this letter please contact Charles A. Hackney at (817) 860-8188.

Sincerely, J. P. Jaudon for J. E. Gagliardo, Chief Reactor Project Branch cc: (see next page)

+ . _ . .

RIV: EPA M C:NMEP C:Sh AI 87-233 CAHackney;ap WLFisher JPJuidhn /.WEGagl C : RPBUdo J / k/87 7/l0/87 f lp/87 ]/lg87' '

'd gr m 818Mr F

N

~. l

~ JUL i 31987 In Reply Refer To: '

Docket: 50-382 Louisiana Power & Light Company ATTN: J. G. Dewease, Senior Vice President Nuclear Operations 317 Baronne Street New Orleans, Louisiana 70160 i

Gentlemen:

The Region IV staff has completed review of the emergency plan changes which you submitted to this office by letter dated June 26, 1987. The emergency plan changes do not appear to decrease the effectiveness of the Waterford 3 Emergency Plan. The following areas were clarified and better defined in ,

revision 11 to the Emergency Response Plan. (

  • Under definitions 1.1.17, Emergency Coordinator, you included 0FF-SITE notifications.
  • Section 3.1.2.1 Emergency Coordination On-Site, you added full authority and responsibility.
  • Section 5.1.2.2.a. third paragraph, off-site notifications, were added to off-site protective action recommendations.

Section 6.6.1.1.b Accountability, paragraph P. states accountability is performed by procedure for each facility's personnel. It is evident from ,

! review of personnel task assignments for the control room and the TSC j l

that personnel have been assigned responsibility for accountability. l Section 5.1.2.3..l.a.6. , included making of f-site notifications.

1 If there are any questions in regard to this letter please contact l Charles A. Hackney at (817) 860-8188. l l

l Sincerely, j J. P. Jaudon for l

l J. E. Gagliardo, Chief Reactor Project Branch cc: (see next page)

. . ~ . . - -

RIV:EPAM C:NMED C:.R , C : RPB .- A1 87-238 CAHackney;ap WLT;isher JPJtidkn ' glEGag'1

? //e/87 7 /10/87 /

/p/87 g/jys7~jdo -

l J

( eJ Yg i

wnWa F

f?%%2 L _ _ _ _ _ _ _

d 4

Louisiana Power & Light Company ,

cc:

Louisiana Power & Light Company ATTN: G. E. Wuller, Onsite ,

Licensing Coordinator P. O. Box B Killona, Louisiana 70066 Louisiana Power & Light Company ATTN: N. S. Carns, Plant Manager P. O. Box B Killona, Louisiana 70066 Middle South Services ATTN: Mr. R. T. Lally P. O. Box 61000 New Orleans, Louisiana 70161 Louisiana Power & Light Company ATTN: K. W. Cook, Nuclear Safety and Regulatory Af f airs Manager 317 Baronne Street '

P. O. Box 60340 l New Orleans, Louisiana 70160 Louisiana Radiation Control Program Director

'6chtoDMB(A045) bec distrib. by RIV:

RPB DRSP Resident Inspector-OPS R. D. Martin, RA Resident Inspector-CONST.

Section Chief (RPB/C)

RPSB MIS SYSTEM RIV File D. Weiss, RM/ALF {

RITS Operator R. Pirfo, DGC R. G. Taylor, RPB/C RSB Inspector Section Chief L. A. Yandell R. L. Bangart R. E. Hall l

Project Inspector, RPB l l

J. Wilson, NRR Project Manager '

! G. Bates D. B. Matthews  ;

1

[ - . - - _ _ - _ _ _ _ - _ _ _ - - _ _