Text
>
i Y
i DISTRIBUTION:
DN 50-320 Central File Local PDR NRC PDR h.
September 25, 1987 TMI HQ r/f I
NRC/TMI 87-073 TMI Site r/f l
BBogar l
LChandler EJordan Docket No. 50-320 SLewis 1
JPartow R
FSchroeder Mr. F. R. Standerfer WTravers E
l Vice President / Director, TMI-2 MMasnik 1
9 GPU Nuclear Corporation JThomas l
P. O. Box 480 TMoslak i
g.
Dear Mr. Standerfer:
I a ' ',
)
Subject:
Technical Specification Change Request No. 63 l ' '(
We have reviewed your letter with attachments of April 23, 1987 regarding
)
requested changes to the Technical Specifications (TS) of Three Hile Island i
W.
Unit-2 (Tt11-2). Additionally a meeting was held between the NRC staff end l
q members of your staf f on September 18, 1987 to discuss the proposed changes.
4
,4 In order to complete our review of the proposed technical specification f
changes we will require additional or clarifying information. Please respond to the following items so that we may complete our review.
1.
On page 1-5 of the proposed TS in item 2.9, if you do not intend to complete defueling of the reactor coolant system prior to entering made 2 provide a justification.
y 2.
Please clarify your intent on containment integrity and containment isolation on pages 11, 1-2 and 1-4.
Will two operable valves or an i
otherwise closed penetration be required for containment integrity? If not, what penetrations other thnn those listed in Table 3.6-2 will be affected, huw. and why?
3.
It is the NRC staff's intent that, other than section 3.9.13, the TS no longer take credit for NRC review of procedures; please update those I'
i sections that reference or imply NRC review of procedures. Appropriate limitations should be substituted for procedure review.
(Sections 3.1.1.1,3.6.1.1,3.6.1.3) 4.
Sections 3.7.6.1 and 3.7.11 refer to safety related systems, components and structures.
How will the list of these systems, components and structures be defined and maintained.
5.
The proposed section 3.8.1.1 would allow heavy load lifts in the reactor building with both circuits between offsite transmission and the onsite class 1E distribution system inoperable. Please update the request or Justify an alternate method of recctor building sump recirculation in the event of a load drop in the reactor vessel area.
r 7
B710050506 070925 PDR ADOCK 05000320
.u,,.,%
P pyg
,NRCFORM 318 (10 80) NRCM 0240 OFFICI AL RECORD COPY j
j fir. F. R. Stenderfer
-c-S e pt e..b e r 25, 1987 l
i f
6.
Proposed specification 3.9.1' should be updnted to reflect current plant c
cunditict.s and operations.
The reference to gases con be coitted.
Radioactive liquids and solids shuuld be addressed in a quantitative manner.
Shoula you have any questions regarding this request f or additianL1 inforrm. tion pit.ase contact u or L. Thaous of my staff.
Sincerely,
/s/ John A. Thomas for
'1illicm D. Travers, Director TMJ-2 Cleenup Project Directorate cc:
T. F. Danni t t f!. E. Royan L. E. Putts S. l.evin J. J. Byrne A. i!. Hiller Service Distribution List.
(see attochtd) l l
I i
i l
I 1
" ' " >..T.MICRQ..
.IMICRQ.s.
.IMIC. -
$un"^MMHIhonus ma.
..dAIhonla..
.WOIr.a
.s..
...//5./87 9._ g.....9./g./.87 9
87 orn >
...j sne one ais ocem uncu m' OFFICIAL RECORD COPY
n TMI-2 SERVICE LIST William T. Russell Frank Lynch, Editorial Regiona1' Administrator The Patriot
.U.S. Nuclear Regulatory Commission 812 Market Street 631 Park Avenue Harrisburg, PA 17105 King of Prussia, PA 19406 Robert B. Borsum
'Dr. Judith H. Johnsrud Babcock & Wilcox Environmental Coalition on Nuclear Power Nuclear Power Division 433 Orlando Avenue Suite 220 State College, PA.16801 7910 Woodmont Avenue Bethesda, MD 20814 Ernest L. Blake, Jr., Esq.
Shaw, Pittman, Potts, and Trowbridge Michael Churchhill, Esq.
4 2300 N Street, N.W.
PILCOP Washington, DC 20037 1315 Walnut Street Suite 1632 Secretary Philadelphia, PA 19107 U.S. Nuclear Regulatory Commission Washington, DC 20555 Marvin 1. Lewis 7801 Roosevelt Blvd. #62 Frederick S. Rice, Chairman Philadelphia, PA 19152 Dauphin County Board of Commissioners Dauphin County Courthouse-Jane Lee Front and Market Streets 183 Valley Road Harrisburg, PA 17101 Etters, PA 17319 Thomas M. Gerusky, Director Walter W. Cohen, Consumer Bureau of Radiation Protection Advocate Department of Environmental Resources Department of Justice P. O. Box 2063 Strawberry Square,14th Floor Harrisburg, PA 17120 Harrisburg, PA 17127 Ad Crable Mr. Edwin Kintner Lancaster New Era Executive Vice President 8 West King Street -
General Public Utilities Lancaster, PA 17601 Nuclear Corporation 100 Interpace Parkway U.S. Department of Energy Parsippany, NJ 07054 P. O. Box 88 Middletown, PA 17057 U.S. Environmental Prot. Agency Region III Office David J. McGoff Attn:
EIS Coordinator Office of LWR Safety and Technology Curtis Building (Sixth Floor)
NE-23 6th and Walnut Streets U.S. Department of Energy Philadelphia, PA 19106 Washington, DC 20545 William Lochstet 104 Davey Laboratory Pennsylvania State University University Park, PA 16802
- _ _ _ _ _ _