ML20235J372

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Concluding That Continued Operation of Facility Not Affected by Advanced Gas Reactor Steam Generator Tube Failures
ML20235J372
Person / Time
Site: Fort Saint Vrain 
Issue date: 02/13/1989
From: Heitner K
Office of Nuclear Reactor Regulation
To: Robert Williams
PUBLIC SERVICE CO. OF COLORADO
Shared Package
ML20235J374 List:
References
TAC-65991, NUDOCS 8902240256
Download: ML20235J372 (3)


Text

p x

February 13, 1989 p-i i

Docket No. 50-267 Mr. R. O. Williams, Jr.

Senior Vice President, Nuclear Operations Public Service. Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Williams:

SUBJECT:

FORT ST. VRAIN STEAM GENERATOR BIMETALLIC WELDS (TACN0.65991) l During 1986 and 1987, we received reports concerning steam generator (boiler) tube failures at certain Advanced Gas Reactor's (AGRs) in the United Kingdom. The similarity of these AGR steam generators to those at Fort St.

Vrain (FSV), prompted an inquiry into the failure mechanisms expected at FSV for its steam generators. The results of our review are in the enclosed safety evaluation. The staff concludes the continued operation of FSV is not affected by the AGR steam generator tube failures.

Sincerely,

/s/

Kenneth L. Heitner, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

DISTRIBUTION:

As stated

Docket. file;m NRC PDR PD4 Readilig~

Local PDR cc w/ enclosure:

P. Noonan 0GC See next page K. Heitner ACRS(10)

J. Calvo PD4 Plant File L. Rubenstein F. Litton B. Grimes E. Jordan PD4/LA PD4/PM N JCalvo%

PD4/D g!6 PNoonan KHeitner 02/\\\\ /89 02/ 5 /89 02/{/89 Pl 8902240256 890213 PDR ADOCK 05000267 P

PDC j

ye[,,. %

6

. UNITED STATES gy([f g

NUCLEAR REGULATORY COMMISSION l

{

L_.

E WASHINGTON, D. C. 20555

. ', [

'~

  • g February 13,.1989

....+

l Docket No. 50-267 l

l l

Mr. R. O. Williams, Jr.

Senior Vice President, Nuclear Operations Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Will:

ams:

SUBJECT:

FORT ST. VRAIN STEAM GENERATOR BIMETALLIC WELDS (TAC NO. 65991)

During 1986 and 1987, we received reports concerning steam generator (boiler) tube failures at certain Advanced Gas Reactor's (AGRs) in the United Kingdom. The similarity of these AGR steam generatt.rs to those at Fort St.

Vrain (FSV), prompted an inquiry into the failure mechanisms expected et FSV for its steam generators. The results of our review are in the enclosed safety evaluation. The staff concludes the continued operation of FSV is not affected by the AGR steam generator tube failures.

Sincerely, Kenneth L. Heitner, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

As stated cc W/ enclosure:

See next page

.~

Mr. R. O. Williams, Jr.

=Public Service Company of. Colorado

. Fort St.'Vrain CC'

~ Mr. D. W. Warembourg, Manager-Albert J..Hazle, Director Nuclear Engineering Division Radiation Control Division Publi.c Service Company Department of Health of Colorado 4210 East lith Avenue P. 0. Box 840 Denver, Colorado 80220 Denver,' Colorado-80201-0840

- Mr. David Alberstein,. Manager Mr. Charles H. Fuller Fort St. Vrain Services Manager, Nuclear Production GA International Services Corporation and Station Manager Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld _ County. Road:19-1/2-Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Resource Mr. P. F. Tomlinson, Manager Management Division Quality Assurance Division Public Service Company of Colorado Public Service Company of Colorade-P. O. Box 840 16805. Weld County Road 19-1/2 Denver, Colorado 80201-0840 Platteville, Colorado 80651 Senior Resident-Inspector Mr. D. D. Hock

~

thS. Nuclear Regulatory Commission President and Chief Executive Officer P. O. Box 640-l Public Service Company of Colorado Platteville, Colorado 80651 Post Office Box 840 Denver, Colorado 80201-08/^

Kelley, Standfield & 0'Donnell ATTN: Mr. J. K. Tarpey Commitment Control Program Public Service Company Building Coordinator Room 900 Public Service Company of Colorado 550 15th Street 2420 W. 26th Ave. Suite 100-D Denver, Colorado 80202 Denver, Colorado 80211 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Chairman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 Regional Representative Radiation Programs Environmental Protection Agency 1 Denver Place 999 18th Street, Suite 1300 Denver, Colorado 80202-2413

__-__.--___--______.____.._.__.__u_

. _...