Amend 7 to License SNM-244 for Dept of Army,Matls Technology Lab,Amending License in Entirety
ML20235G043
Person / Time
Site: 07000263
(SNM-0244-A-07, SNM-244-A-7)
Issue date: 08/31/1987
From: Jennifer Davis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20235G045 List:
References
NUDOCS 8709290413
Download: ML20235G043 (3)


Text

("~-

__-_m_

_ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ _ _ _,,,, _ _ _ _ m.,,m g

NRC Fcrm 374

/~ N

/

I h U.S. NUCLEAR REGULATORY COMMISSION 1

3 l mso PAGE OF PAGESj N

q MATERIALS LICENSE Amendment No. 07 Pursuant to the Atomic Energy Ac't of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, g

Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations g

heretofore made by the licensee, a license i[ hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, N

source, and special nuclear material' designated below; to use such material for the purpose (s) and at the place (s) designated below;to Il deliver or transfer such material to persons authorized to receive it in ac license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of'1954, as amended, and is ;

g subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any l g conditions specified below.

I Licensee 8

In accordance with letter dated l

May 27, 1987, l-i Department of the Army

3. License number SNM-244 is amended in i

l Materials Technology Laboratory its entirety to read as follows:

l l

Il 2.

Arsenal Street l

Watertown, Massachusetts 02172-0001

4. Expiration date August 31, 1992 l

l

5. Docket or I

(

Reference No.

070-00263

6. Byproduct, source, and/or
7. Chemical and/or physical
8. Maximum amount that licensee N

E special nuclear material form Gmay possess at any one time f

',, cnder this license l

p, l

A. Enriched uranium A. Any (A. 8 grams y

B. Plutonium 239 B. Sealed sources

'). Not to exceed i

80 grams per

!i (q

source, 160

{p d

grams total ly 5

C. Plutonium 239 C. Sealed sources C. 32 grams N

D. Sealed sources

'D. 0.16 micrograms hl,D. Plutonium 239

'l d

M 9.

Authorized use f

l

'i A.

For use in neutron detectors.

l 4

B.

For use in instrument calibration.

Y l

C.

For use in neutron filters.

D.

For use as alpha source standards.

g CONDITIONS I

i i

I 10.

Licensed material shall be used only at U.S. Army Laboratory Command, Materials l

l Technology Laboratory, Watertown, Massachusetts.

I i

11.

Licensed material shall be used by, or under the supervision of, John Antal, l

l Forrest Burns, Charles Dady, Alfred Broz, Laurence Jennings, Louis Farere, James l

4 McCauley or Robert Fitzpatrick.

I I

A(1) Each sealed source or detector cell acquired from another person and j

l 12.

containing licensed material, other than hydrogen 3, with a half-life y

g greater than 30 days and in any form other than gas shall be tested for

'g g

contamination and/or leakage before use.

In the absence of a certificate M

]

from a transferor indicating that a test has been made within 6 months li before the transfer, a sealed source or detector cell received from (f'

i N

another person shall not be put into use until tested.

870927041Yh($$$1

~~

U l

REG 1 LIC7 l

s--=

  • 0

_______J ma

l c103@ Oc:tm WG8 OD.O. P tGo0] cD@GOSM@CDt7 @@MIM30@2

^

PAoE 2

o 3

DAGES License numWT MATERIALS L,ICENSE

~

Docket or Reference number SUPPLEMENTARY SHEET Amendment No. 07 (12. continued)

CONDITIONS l

(2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source or detector cell is exempt from such leak tests when the source or detector cell contains 100 microcuries or less of beta and/or gamma emitting materials or 10 microcuries or less of alpha.

l emitting material.

l

-(3) Except for alpha sources, the periodic leak test required by this condi-l tion does not apply to sealed sources that are stored and not being used.

The sources excepted from this test 'shall. be tested for leakage before any use or transfer to another person ~ unlessithey have been leak tested within 6 months before the date of use or transfer, B.

Each sealed source or detector cell fabricated by the licensee shall be h

inspected and tested for construction defects, leakage,.and contamination prior to use or transfer as a sealed source or detectoNeell.

If the inspection or test reveals any construction defe' cts or 0.005 microcurie or greater of contamination, the source shall not be used or transferred j

as a sealed source or detector cell until jit;has been repaired, decontami-i nated and retested.

5 e

(

C.

Each sealed source containing licensed material, other than hydrogen 3, i

with a half-life greater than 30 daysf and in any, form other than gas i

shall be tested for leakage and/ ors contamination at intervals not to l'-

1 exceed 6 months except that each source designed for the purpose of i,

s H

emitting alpha particles shall be tested at intervals not to exceed 3

-]

months.

\\p; D.

The test shall be capable.of detecting 'the presence (of 0.005 microcurie ji i

of radioactive material on the test sample. The4 test sample shall be taken from the sealed source or detector cell or from the surfaces of the l

device in which the sealed' source or, detector cell is permanently or i{

semipermanently mounted or stored o'n which one might expect contamination I"

to accumulate. Records of leak test results shall be kept in units of q

microcuries and maintained for inspection by the Commission.

Records may l

j be disposed of following Commission inspection.

a j

d E.

If the test required by Subsection A. or C. of this condition reveals the

j presence of 0.005 microcurie or more of removable contamination, the i

licensee shall immediately withdraw the sealed source or detector cell l

from use and shall cause it to be decontaminated and repaired or to be

{

}

disposed of in accordance with Commission regulations. A report shall be j

l filed within 5 days of the date the leak test result is known with the i

y i

d U. S. Nuclear Regulatory Commission, Region I, ATTN:

Chief, Nuclear l

d Materials Safety and Safeguards Branch, 631 Park Avenue, King of Prussia, t,

f Pennsylvania 19406, describing the equipment involved, the test results, i'

and the corrective action taken.

l 3

t 1

y j

tw

+---- m ews+,mu m m mmmysomymmms.mmmmmmmm

____________.___.,m______________,

I l 'uRc ro,m 3NA U.S. M EAR REGULATORtf COMMISSIOP3 O

PAGE 9

OF 3

PAGES I

License nudd l

MATERIALS LICENSE SN ~

g,,,,,,, y,,,,,,,,,, mber l

SUPPLEMENTARY SHEET ll 070 DD2' '

I

[

Amendment No. 07

! (continued)

CONDITIONS 4

W 13.

Sealed sources containing licensed material shall not be opened.

g l

N 14.

Except as specifically provided otherwise in this license, the licensee shall

!?

l conduct its program in accordance with the statements, representations, and l

procedures contained in the documents including any enclosures, listed below, g

The Nuclear Regulatory Commission's regulations shall govern unless the state-N ments, representations and procedures in the licensee's application and corre-1 spondence are more restrictive than the r.egulations.

9 N

l l

J A.

Application dated May, 27, 1987 i

g N

R n

8 1

4l

/:

Nl i,

g sj

.)

p N

i i

f' di f

n l

i 4:

Mi l$

f Ni l

'dj

& j lk i

N k'

hl

\\

N t

@f i

si x

4 Wl Ml t'

in:.

(l l

For the U.S. Nuclear Regulatory Commission NI

'DrIginal Signed By:

M fDate By

lrack Devis f

4.

Nuclear Materials Safety and ij Safeguards Branch, Region I

j f

King of Prussia, Pennsylvania 19406 g

(

4; i;

. \\

ditFR32hxws,:rattv1MiszmmsTrhurmtemwne gzza;zera