Text

_

SEP 221987 SENT TO ALL OPERATING PLANTS Gentlemen:

Enclosed is a copy of NRR's position regarding entry into an LC0 based on IST surveillance results which are in the required action range. Our purpose in distributing this position to all Region III utilities is to (1) advise you on the position Region III plans to take regarding entry into an LC0 based on IST test results; and (2) indicate that this position may be different from that which you are currently using.

Please note that no time is allowed for an analysis to determine whether the component can be considered OPERABLE if the test data falls into the required action range, thereby indicating that it cannot perform within its design envelope.

We suggest that you review your own practices in performing IST surveillance to anure that data falling into the required action range triggers entry into the appropriate LC0 action statement clock.

It is our intent during the conduct of future IST inspections to determine that LCOs are appropriately entered when surveillance test results are in the required action range.

Sincerely, Original signed by 1.. Bert Davis A. Bert Davis Regional Administrator g

r

Enclosure:

As stated Mg i

See Attached Distribution 4?

5

~

II b C%pi, y,p, RIII RII RIII RFJI ad w

of x

r af ll Davis l

yn

&o 7jn 3,,fck,,M/

p 111ps/abl Hehl Miller P

a709290105 070922 lt ADOCK0500ggO j

DR

i Multiple Addressees 2

SEP 2 21987 Distribution cc:

D. C. Cook, Docket No. 50-315; No. 50-316 -

l Perry, Docket No. 50-440; No. 50-441 -

Braidwood, Docket No. 50-456; No. 457 -

Byron, Docket No. 50-454; No. 50-455 ;

LaSalle, Docket No. 50-373; No. 50-374 -

Dresden, Docket No. 50-10; No. 50-237;'No. 50-249 Quad Cities, Docket No. 50-254;'No. 50-265 Zion, Docket No. 50-295;'No. 50-303 Big Rock Point, Docket No. 50-1559 Palisades, Docket No. 50-255 LACBWR, Docket No. 50-409 s Fermi 2, Docket No. 50-341 Clinton, Docket No. 50-461-Duane Arnold, Docket No. 50-331 Pr. Island, Docket No. 50-282;-No.50-306 i

Monticello, Docket No. 50-263 '

)

Davis-Besse, Docket No. 50-346 j

Callaway, Docket No. 50-483 -

Point Beach, Docket No. 50-266; No. 50-301 Kewaunee, Docket No. 50-305 Single Copy Sent to:

RIII Green RIII Public Affairs Public Documents RIII Files DCD/DCB (RIDS)

Licensing Fee Management Branch l

l l

{

f l

l o

l