ML20235F409
| ML20235F409 | |
| Person / Time | |
|---|---|
| Site: | 07001113 |
| Issue date: | 09/22/1987 |
| From: | Dan Collins NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Lees E GENERAL ELECTRIC CO. |
| Shared Package | |
| ML20235F412 | List: |
| References | |
| NUDOCS 8709290089 | |
| Download: ML20235F409 (2) | |
Text
- _ _ _ _ _
_ _ =
Qf0C/&
j i
.SEP 2 21937 l
Docket No. 70-1113 License No. SNM-1097 Gen 6ral Electric Company leATTN: Mr. Eugene A. Lees, General Manager y' $
Nuclear Fuel and Components c:
' i Manufacturing y
P. O. Box 780 co ;o Wilmington, NC 28402 7
> c1 Gentlemen:
39 un
\\
SUBJECT:
NRC INSPECTION REPORT NO. 70-1113/87-12
'V This rafers to the Nuclear Regulatory Commission (NRC) inspection conduct'ed by P. G. Stoddart on August 24-28, 1987.
The inspection included a review of 1
activities authorized for your Wilmington facility.
At the conclusion of the l
inspection, the findings were discussed with those members of your staff identified in the enclosed inspection report.
Areas examined during the inspection are identified in the report.
Within
{
these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progress.
Within the scope of the inspection, no violations or deviations were identified.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and its enclosure will be placed in the NRC Public Document Room.
Should you have any questions concerning this letter, please contact us.
l Sincerely, cm c uc-
, ny DOUGLAS M rrug Douglas M. Collins, Chief 9709290009 B70922 Emergency Preparedness and
{DR ADOCK0700g3 Radiological Protection Branch Division of Radiation Safety and Safeguards
Enclosure:
Inspection Report cc w/ encl:
(See page 2) 1 i
f RM7
General Electric Corporation 2
cc w/ encl:
(J<'Preston Winslow, Manager Licensing and Nuclear Materials Management
.bcc w/o encl:
ditense Fee Management Branch bec w/ encl:
Document Control Desk State of North Carolina i
RII RII RII
'j c Pb,d art h[/87 I
Te EM ne
.9/f/87 9/.
9/28/87 l
_ __-_ -_---.