___--__

EG 4't[@

'o, _

NUCLEAR REGULATORY COMMISSION e

UNITED STATES c

g

(,p, WASHINGTON, D. C. 20555 J,

% *'.u /

JUN 2 019fD

..+

MEMORANDUM FOR:

Distribution FROM:

Thomas L. King, Acting Chief Advanced Reactor & Generic Issues Branch Division of Regulatory Applications

SUBJECT:

MEETING WITH DOE TO REVIEW THE MODULAR HTGR PRELIMINARY SAFETY INFORMATION DOCUMENT (PSID) CHAPTER 13.1, THE EMERGENCY PLANNING BASIS REPORT, THE PRA DOCUMENT' AND OTHER ISSUES The subject meeting is the seventh in a series of meetings with DOE and its contractors to discuss NRC comments on the conceptual desian for the modular HTGR. The meeting will be held on July 15, 1987 and July 16,1987 in Room P-118 and will begin at 9:00 a.m.

A preliminary agenda is enclosed.

The review will consist of a discussion of PSID Chapter 13.1, " Position on Emergency Preparedness," the Emergency Planning Basis Document, and the PRA document. Other issues will include discussion of the role of the operator, and accidents beyond the design basis. Reviewers for this material, together with contractors from ORNL and BNL, should plan to meet in my office at 1:00 p.m. on July 14, 1987 to discuss their planned comments on the subject documents.

If you have any questions please contact Pete Williams, the Project Manager (X29613).

f Thomas L. King, Acting Chief Advanced Reactor & Generic Issues Branch Division of Regulatory Application

Enclosure:

As stated

{[

k 8707060597 870629 PDR PROJ 672F PDR i

t PRELIMINARY AGENDA NRC/ DOE MEETING ON MHTGR REVIEW JULY 15, 1987 ROOM P-ll8 9:00 - 9:30 OPENING REMARKS NRC, DOE, OTHERS 9:30 - 10:00 OVERVIEW:

CHAPTER 13.1 AND EPBR GAT

- Objectives

- Background

- Comparison to Regulatory Precedence

- Approach to Emergency Planning Bases 10:00 - 10:30 LICENSING BASIS EVENTS FOR EMERGENCY PLANNING GAT

- Selection of LBEs for Emergency Planning 10:30 - 10:45 BREAK 10:45 - 11:45

- Description of Emergency Planning Basis Events GAT

- Radionuclides Sources, Release and Doses

- Response to NRC questions 11:45 - 12:45 LUNCH 12:45 -

1:45 EMERGENCY PLANNING ZONE GAT

- Assessment of Plume Exposure Pathway Doses

- Selection of Plume Exposure Pathway EPZ

- Discussion of Emergency Planning Implications

- Response to NRC Questions 1:45 - 2:15 CONCLUSIONS GAT 2:15 - 2:30 BREAX 2:30 - 3:30 ROLE OF THE OPERATOR NRC/ DOE 3:30 - 3:45 BREAK

~

3:45 - 5:00 GENERAL DISCUSSION (C0ULD INCLUDE COMMENT RESPONSES)

NRC/ DOE

PRELIMINARY AGENDA NRC/ DOE MEETING ON MHTGR REVIEW JULY 16, 1987 ROOM P-118 8:30 - 9:00 INTRODUCTION NRC/ DOE /0THERS 9:00 - 10:00 OVERVIEW GAT Objectives of Briefing Objectives of the MHTGR PRA Scope & Dimensions of the PRA Description of the PRA Document Conclusion from PRA 10:00 - 10:15 BREAK 10:15 - 12:15 PRA BACKGROUND AND METHODS GAT Background & Previous Experience Selection of Initiating Events

- External Events

- Internal Initiator Plant System & Component and Fault Tree Development Frequency Assessment Methods including Human Actions Radiological Consequence Methods Uncertainty Assessment Methods 12:15 - 1:15 LUNCH 1:15 - 3:15 DETAILED PRA RESULTS GAT Accidents within Licensing Bases

- A005

- DBEs

- EPBEs Accidents beyond Licensing Bases

- Reactivity Transients GAT

- Conduction Cooldown w/o RCCS BNL/ GAT

- Large Steam Ingress CE/ GAT

- Large Depressurization CE/ GAT

- Seismic Failure of Core Support

- Large Failure of Cross Duct 3:15 - 4:00 BREAK 4:00 - 5:00 CONCLUSION AND DISCUSSION 14 9

'JUN 2 91987

' E. -

DISTRIBUTION RES Cire Chron ARGIB R/F E. Beckjord T. Speis B. Morris Z. Rosztoczy T. King

.J. N. Wilson C. Allen R..Landry P. Williams J. Flack R. Baer N. Anderson F. Cherny S. Shaukat R. Johnson D. Thatcher J. Hulman J. Glynn L. Soffer J. Read D. Cleary A. Murphy G. Arndt R. Kirkwood M. Lamastra R. Erickson B. Mendleschn H. VanderMolen E. Chelliah L. Beltracchi F. Congel J. Swift 4

O. Lynch D. Matthews R. Senseney-M. Spangler F. Coffman 1

S. Ball, ORNL P. Kroeger, BNL G. VanTuyle, BNL R. Ireland, Reg. IV M. El-Zeftawy, ACRS/H-1026 PDR - Project 672

Project: File : 672 E( Cen.-~t.b1F'11eR m

1 H

I 1