n-
, (). -
- NRC Fodn 374 p3gg ' ~]~ gp p
PAGc5 0-34)
U.S. NUCt. EAR REGULATORY COMMISSION g
C 0
MATERIALS LICENSE Amendment No. 02 g
Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93 -438). and Title 10,
- f. Code of Federal Regulations. Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations j
~ ; heretofore made by the licensee, a heense is hereby issued authorizing the licensee to receive, acquire, possess, and transfer
(
$1 source, and special nuclear matenal designated below; to use such material for the purpose (s) and at the place (s) designa:ed below; to
{
deliver or transfer such matenal to persons authorized to receive it in accordance with the regulations of the appheable Part(d. This
{
license shall he deemed to contam the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is 4 %, ;" "M """""""'"""""" ""*" """" """"" "*""'"""0 HEE"tCd2 @F" ""' J g
lt Licensee p
In etccordance with letter dated t
June 4, 1987, 3 "" 5" " "'" h
SNM-1869 is amended in its L
Princeton Gamma-Tech, Inc.
entirety to read as follows:
I i?
1200 State Road
~
~
s Princeton, New Jersey 08540
- 4. spiranonfat.
June 30, 1990
- 5. Docket or ni
.1. Refnence No.
070-02915 E 6. Byproduct, source, and/or
- 7. Chemical and/or physical
- 8. Maximum amount that licensee E
special nuclear material form may possess at any one time i
f under this license A. Plutonium 239 A. Sealed neutron source A. 16 grams (NUMEC-Model A) l B. Plutonium 238 B. Sealed source B. 1 milligram
}
(Amersham Model PPC)
M
~
9.
Authorized use l
l A. and B.
Research and development as defined in Section 30.4(q) of 10 CFR Part 30.
CONDITIONS
~
I! 10.
Licensed material shall be used only at the licensee's facilities, Route 518, East of Rcuta 206, Pocky Hill, New Jersey.
c
! 11. Licensed material shall be used by, or under the supervision of, Joseph A. Baiker and s;
Robert Toft.
g{j12.
A(1) Any sealed sources or detector cells specified in items 7.A. and 7.B.
shall be tested for leakage and/or contamination at intervals not to exceed 6 months. Any source or detector cell received from another jg 4
person which is not accompanied by a certificate indicating that a test I
was performed within 6 months before the transfer shall nct be put into d
use until tested.
(2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source or detectcr cell is exempt from such leak tests pq a
when the source or detector cell contains 100 microcuries or less of beta and/or gamma emitting material or 10 microcuries or less of alpha emitting d
material.
A d
B.
Any sealea source or detector cell in storage and not being used need i
Q not be tested. When the source or aetector cell is removed from storage l \\
L for use or transfer to another person, it shall be tested before use or 6 J "" 1 E ! ? " " 1 JE
N ATO Y O
License numter SNM-1869 MATERIALS LICENSE N
SUPPLEMENTARY SHEET 070-02915
[
s s
4 Amendment No. 02
,(
(12. continued)
CONDITIONS li C.
The test shall be capable of detecting the presence of 0.005 microcurie of radioactive material on the test sample.
If the test reveals the i
presence of 0.005 microcurie or more of removable contamination, the.
i source or detector cell shall be removed from service and decontaminated, E
repaired, or disposed of in accordance with Commission regulations. A l
report shall be filed within 5 days of the date the leak test result is i
known with the U.S. Nuclear Regulatory Commission, Region I, ATIN:
- Chief, Nuclear Materials Safety and Safeguards Branch, 631 Park Avenue, King of e
f Prussia, Pennsylvania 19406. The report shall specify the source involved, i
the test results, and corrective action taken.
Records of leak test i
results shall be kept in units of microcuries and shall be maintained for 3
inspection by the Commission.
Records may be disposed of following j
Commission inspection.
6
(
D.
Tests for leakage and/or contamination shall be performed by the licensee or by other persons specifically licensed by the Conmission or an Agree-4 l
ment State to perform such services.
4 g
- 13. Sealed sources or detector cells containing licensed material shall not be i
opened or sources removed from source holders oridetector cells by the s
licensee.
4 14.
Except as specifically provided otherwise in'this license, the licensee shall y
conduct its program in accordance with the statements, ' representations, and procedures contained in the documents including any enclosures, listed below.
ej The Nuclear Regulatory Commission's regulations shall govern unless the i
statements, representations and procedures in the licensee's application j
and correspondence are more restrictive than the' regulations.
E l
A.
Application dated January 9, 1985 i
B.
Letter dated June 4, 1987 c
1 e
W
's M
5
'1 5
4 4
l For the U.S. Nuclear Regulatory Commission i
i 80 4 gi wrner storr e 3fr.
Date By T
- r. m ~.
5 Nuclear Materials Safety and
,i Safeguards Branch, Region I i
King of Prussia, Pennsylvania 19406 i
4 r-wwww w====w-== nrousim.mm-es