Forwards SER & Technical Evaluation Rept EGG-EA-7026 Re Conformance to Reg Guide 1.97.Instrumentation Provided by Util for Meeting Provisions of Reg Guide Acceptable Except for Items on Monitoring of Variable Neutron Flux
ML20234B803
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 09/14/1987
From: Butler W
Office of Nuclear Reactor Regulation
To: Leonard J
LONG ISLAND LIGHTING CO.
Shared Package
ML20234B806 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 NUDOCS 8709210083
Download: ML20234B803 (4)


Text

1 Septenter 14, 1987 Docket No.: 50-322 Mr. John D. Leonard, Jr.

Vice President - Nuclear Operations Long Island Lighting Company Shoreham Nuclear Power Station P. O. Box 618, North Country Road Wading River, New York 11792

Dear Mr. Leonard:

SUEJECT: EMERGENCY RESPONSE CAPABILITY - CONFORMANCE TO REGULATORY GUIDE 1.97, REVISION 2 RE:

SHOREHAM NUCLEAR POWER STATION We have completed the subject review with respect to the Shoreham Nuclear Power Station, Unit 1.

We find the instrumentation provided by the Long Island i

Lighting Company for meeting the provisions of Regulatory Guide 1.97, Revision 2, acceptable except for the item related to the monitoring of variable neutron flux.

In your letter dated October 23,1985 (SNRC-1209) you have committed to a study of the neutron monitoring system.

Ir, addition, the Shoreham license is conditioned to require installation or upgrade of instrumentation consistent with the provisions of Regulatory Guide 1.97, Revision 2, prior to startup l

following the first refueling outage except as agreed by the NRC. Therefore, we find the existing neutron flux instrumentation to be acceptable for interim operation until startup following the first refueling outage.

J Our safety evaluation with its attachment, EG&G Idaho, Inc., Technical Evaluation Report dated March 1986, are enclosed.

(

Sincerely,

/s/

Walter R. Butler, Director hb[ kDO Project Directorate I-2 O

22 F

PDR Division of Reactor Projects I/II l

Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/ enclosures:

See next page DISTRIBUTION:

Docket File SVarga/BBoger NRC PDR/ Local PDR WButler l

PDI-2 Rdg File RLo/GRivenbark l

M0'Brien 0GC - Bethesda Previously concurred *:

PDI-2/PMz/h

~

PDI-2/D f

WButler W RLo:ca 09/1/87 q /g/87

l 1

[p# MGQ

'o UNITED STATES

! ) 3 #. - 'j NUCLEAR REGIJLATORY COMMISSION j

G E

WASHING TON, D. C. 20555 l

i f

I os

%,*****/

September 14, 1987 l

Docket No.: 50-322 I

1 Mr. John D. Leonard, Jr.

Vice President - Nuclear Operations Lcng Island Lighting Company Shoreham Nuclear Power Station P. O. Box 618, North Country Road Wading Piver, New York 11792 i

Dear Mr. Leonard:

l

SUBJECT:

EMERGENCY RESPONSE CAPABILITY - CONFORMANCE TO REGULATORY GUIDE 1.97, REVISION 2 RE:

SHOREHAM NUCLEAR POWER STATION I

We have completed the subject review with respect to tne Shoreham Nuclear Power Station, Unit 1.

We find the instrumentation provided by the Long Island Lighting Company for meeting the provisions of Regulatory Guide 1.97, Revision 2, acceptable except for the item related to the monitoring of variable neutron j

flux.

In your letter dated October 23, 1985 (SNRC-1209) you have committed to I

a study of the neutron monitoring system.

In addition, the Shoreham license is conditioned to require installation or upgrade of instrumentation consistent with the provisions of Regulatory Guide 1.97, Revision 2, prior to startup following the first refueling outage except as agreed by the NRC.

Therefore, j

we find the existing neutron flux instrumentation to be acceptable for interim operation until startup following the first refueling outage.

Our safety evaluation with its attachment, EG&G Idaho, Inc., Technical Evaluation Report dated March 1986, are enclosed.

Sincerely, e t/1l 0

v Walter R. Butler, Director Project Directorate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Enclosures:

As stated cc w/ enclosures:

See next page

Mr. John D. Leonard, Jr.

Shoreham Nuclear Power Station Long Island Lighting Company (list 1)

CC*

l Stephen B. Lathan, Esq.

Gerald C. Crotty, Esq.

John F. Shea, III, Esq.

Ben Wiles, Esq.

Twomey, Lathen & Shea Counsel to the ilovernor Attorneyc at Law Executive Cnamber Post Office Box 30P State Capitol 33 West Second Street Albany, New York 12224 Riverhead, New York 11001 Herbert H. Brown, Esq.

Alan S. Rosenthal, Esq., Chairman Lawrence Coe Lanpher, Esq.

Atomic Safety & Licensing Appeal Board Karla J. Letsche, Esq.

I U.S. Nuclear Regulatory Commission Kirkoatrick & Lockhart Washington, D.C.

20555 South Lobby - 9th floor 1800 M Street, N.W.

Washington, D.C.

20036-5891 W. Taylor Reveley, III, Esq.

Hunton & Williams Dr. Monroe Schneider 707 East Main Street North Shore Committee Post Office Box 1535 Post Office Box 231 Richmond, Virginia 23212 Wading River, New York 11792 Howard A. Wilber Fabian G. Palomino, Esq.

Atomic Safety & Licensing Appeal Board Special Counsel to the Governor U.S. Nuclear Regulatory Commission Executive Chamber - State Capitol Washington, D.C.

20555 Albany, New York 12224 Atomic Safety & Licensing Board Panel Anthony F. Earley, Jr., Esq.

U.S. Nuclear Regulatory Commission General Counsel Washington, D.C.

20555 Long Island Lighting Company 175 East Old County Road l

Atomic Safety & Licensing Appeal Board Hicksville, New York 11801 l

Panel U.S. Nuclear Regulatory Commission Mr. Lawrence Britt Washington, D.C.

?0555 Shoreham Nuclear Power Station Post Office Box 618 Gary J. Edles, Esq.

Wading River, New York 1179?

Atomic Safety & Licensing Appeal Board U.S. Nuclear Regulatory Commission Martin Bradley Ashare, Esq.

Washington, D.C.

20555 Suffolk County Attorney H. Lee Dennison Building Richard M. Kessel Veteran's Memorial Highuy Chairman & Executive Director Hauppauge, New York 11788 New York State Consumer Protection Board Room 1725 Resident Inspector 250 Broadway Shoreham NPS New York, New York 10007 U.S. Nuclear Regulatory Commission Post Office Box B Jonathan D. Feinberg, Esq.

Rocky Point, New York 11778 New York State Department of Public Service Regional Administrator, Region I Three Empire State Plaza U.S. Nuclear Regulatory Commission Albany, New York 12223 631 Park Avenue King of Prussia, Pennsylvania 19406 l

l

__________m.

l l

t 1

Long Island Lighting Company Shoreham (1) l l

l cc:

Robert Abrams, Esq.

Mr. Francis J. GluchoIski Attneney General of the State Assistant Town Attorney of New York Town of Brookhaven

)

ATTN:

Peter Bienstock, Esq.

Department of Law Department of Law 475 East Main Street State of New York Patchogue, New York 11772 Two World Trade Center i

Room 46-14 New York, New York 10047 Mr. William Steiger j

Plant Manager Shoreham Nuclear Power Station Post Office Box 6?8 j

Wading River, New York 11792 MHB Technical Associates 1723 Hamilton Avenue - Suite K San Jose, California 95125 l

Honorable Peter Cobalan j

Suffolk County Executive l

l County Executive / Legislative Building l

Veteran's Memorial Highway Hauppauge, New York 11788 Mr. Jay Dunkleberger New York State Energy Office l

Agency Building 2 l

Empire State Plaza i

Albany, New York 12223 Ms. Nora Bredes i

Shoreham Opponents Coalition 195 East Main Street Smithtown, New York 11787 l

Chris Nolin New York State Assembly Energy Committee 626 Legislative Office Building l

Albany, New York 12248 Peter S. Everett, Esq.

Hunton & Williams 2000 Pennsylvania Avenue, NW i

Washington, D.C.

20036

_ _ _ _ _ _ _ _ _ _ _ - _ _ _ _