Text
'
g.
o UNITED STATES g
- [
g NUCLEAR REGULATORY COMMISSION j
WASHINGTON, D. C. 20555 September 17, 1987 Docket No. 99901093/S7-01 Allied Nut & Bolt Company, Incorporated ATTN: Mr. Jerome Rosenstock President 520 Hertzog Doulevard King of Prussia, Pennsylvania 19406 Gentlemen:
This letter addresses the inspection of your facility at King of Prussia, PA conducted by J. C. Harper of this office on June 24-26, 1987, and the discussions of their findings with Mr. J. Korin and other members of your staff at the conclusion of the inspection.
The inspection was conducted as a result of an ongoing Vendor Inspection Branch (VIB) fastener evaluation program. This inspection was conducted in order to review the Allied Nut & Bolt (ANB) compliance with and implementation of 10 CFR 50 Appendix B and 10 CFR Part 21. Areas examined during the NRC inspec-tion and our findings are discussed in the enclosed report. This inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
During this inspection it was found that the implementation of your QA program failed to meet certain NRC requirements. A violation was identified in the area of imposing the requirements of 10 CFR Part 21 on sub-tier vendors of heat treating, calibration, material, and laboratory services. Noncon-formances were identified in the areas of training and indoctrination, procurement, and dispositioning nonconforming materials.
The enclosed Notice of Violation is sent to you pursuant to the provisions of Section 206 of the Energy Reorganization Act of 1974.
You are required to submit to this office within 30 days from the date of this letter a written statement containing:
(1) a description of steps that have been or will be taken to correct these items; (2) a description of steps that have been or will be taken to prevent recurrence; and (3) the dates your corrective actions and preventive measures were or will be completed. We will consider extending the response time if you can show good cause for us to do 50.
l M ((
8709100238 B70917 l
PDR GA999 EMVALNUT 99901093 PDR q
l Allied Nut & Bolt Company, Inc. September 17, 1987 l
You are also requested to submit a similar written statement for each item which appears in the enclosed Notice of Nonconformance.
i The responses requested by this letter are not subject to the clearance i
procedures of the Office of Management and Budget as required by the Paperwork j
i Reduction Act of 1980,-PL 96-511.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this l
1etter and the enclosed inspection report will be placed in the NRC's Public i
Document Room.
Should you have any questions concerning this inspection, we will be pleased I
to discuss them with you.
Sincerely, i
E lis W. Merschoff, Chief f
Vendor Inspection Branch Division of Reactor Inspection and Safeguards Office of Nuclear Reactor Regulation cc:
Public Service Electric & Gas Mr. Corbin A. McHeill, Jr.
Vice President - Nuclear flucicar Administration Building P.O. Box 236 Hancocks Bridge, NJ 00038
Enclosures:
1.
Appendix A-Notice of Violation 2.
Appendix B-Notice of Nonconformance 3.
Appendix C-Inspection Report 110. 99901093/87-01
.A, Allied Nut & Bolt Company, Inc. september 17, 1987 DISJ#IBUTION:
MD5 Code IE:09 VIB Reading DRIS Reading JPartlow BGrimes EMerschoff JStone JHarper LParker DKAllsopp, RI, Hope Creek RWBorcharde, SRI, Hope Creek JJLyash, RI, Hope Creek
-l JTKenny, SRI, Salem i
GWRivenbark, PM, Hope Creek ~
i j
Oh 6
el
-*See previous page for concurrences, OFC
- VIB:DRIS
- 50/VIB:DR15
- ABC/VIS:
NAME :JHarper:tt*
- JStone*
.EMerschof DATE :09/08/87
- 09/10/87
- 9//h/87
\\-
Allied Nut.& Bolt Company, Inc.- September 17, 1987 I
I DISTRIBUTION:
RID 5 Code IE:09 VIB Reading-l DRIS Reading JPartlow J
BGrimes EMerschoff JStone JHarper LParker DKA11sopp, RI, Hope Creek RWBorcharde, SRI, Hope Creek JJLyash, RI, Hope Creek JTKenny, SRI, Salem GWRivenbark, PM, Hope Creek i
i i
i i,
i ;
a
- See previous page for concurrences.
I C
- VIB:DRIS
- 5C/VlB:DRIS :ABC/VIB:
I 3...:....._____....:............
KE :JHarper:tt*
- JStone*
.EHerschof
- E :09/08/87
- 09/10/87
- 3/lh/87 n j i
- - -