Category:Letter
MONTHYEARIR 05000361/20240052024-10-0404 October 2024 NRC Inspection Report 05000361/2024005 and 05000362/2024005 ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status IR 07200041/20244012024-08-16016 August 2024 San Onofe Nuclear Generating Station, Security Baseline Inspection Report 07200041/2024401 IR 05000361/20240042024-08-0909 August 2024 NRC Inspection Report 05000361/2024004 and 05000362/2024004 ML24198A0872024-08-0505 August 2024 Request for Additional Information for Review of the Holtec Model No. HI-STORM Umax Storage System, Amendment 5 ML24191A2472024-07-0202 July 2024 (Songs), Units 1, 2, and 3, and the Independent Spent Fuel Storage Installation - Revision to the ISFSI-Only Emergency Plan and Associated Changes to Emergency Plan Implementing Procedures ML24180A1652024-06-28028 June 2024 International, Biennial Final Safety Analysis Report Update for the HI-STORM Umax Storage System Per 10 CFR 72.248(c)(6) ULNRC-06892, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC00062024-06-26026 June 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC0006 ULNRC-06891, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00052024-06-26026 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0005 ULNRC-06885, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00032024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0003 ULNRC-06884, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00022024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0002 ULNRC-06886, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00042024-06-12012 June 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0004 ML24178A1132024-06-0606 June 2024 Ameren Missouris Intent to Adopt Revision 1 to Amendment 0 of Certificate of Compliance No. 1040 as Applicable to the ISFSI at the Callaway Plant Site ML24151A6482024-06-0303 June 2024 Changes in Reactor Decommissioning Branch Project Management Assignments for Some Decommissioning Facilities ML24135A0382024-05-30030 May 2024 Application for Holtec Model No. HI-STORM Umax, Amendment 5 - Accepted for Review - Cost Activity Code/Enterprise Project Identification Number 001028/L-2023-LLA-0176 ULNRC-06882, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC00122024-05-16016 May 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC0012 ML24137A2342024-05-16016 May 2024 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Canister HGMPC0011 ML24141A0802024-05-15015 May 2024 (Songs), Units 1, 2 and 3 and Independent Spent Fuel Storage Installation - 2023 Annual Radiological Environmental Operating Report ULNRC-06876, Registration of Dry Spent Fuel Storage Canister HGMPC00102024-04-25025 April 2024 Registration of Dry Spent Fuel Storage Canister HGMPC0010 ML24136A1892024-04-18018 April 2024 HI-STORM Umax Amendment 5 Responses to Requests for Supplemental Information ML24108A1082024-04-17017 April 2024 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Canister HGMPC0009 ULNRC-06872, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00082024-04-17017 April 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0008 ULNRC-06871, Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC00072024-04-17017 April 2024 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Canister HGMPC0007 IR 05000361/20240022024-04-0101 April 2024 – NRC Inspection Report 050-00361/2024-002 and 050-00362/2024-002 ML24094A0642024-03-27027 March 2024 Independent Spent Fuel Storage Installation, Decommissioning Funding Status Report 2023 ML24060A0952024-03-19019 March 2024 Application for Holtec Model No. HI-STORM Umax, Amendment 5 - Supplemental Information Needed - Enterprise Project Identification Number L-2023-LLA-0176 ML24044A0362024-03-0606 March 2024 Acceptance of Holtec International Request for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the Hi-Storm Umax Canister Storage System ML24072A5022024-03-0404 March 2024 International, Submittal of Rsi Supplemental Information for Revision to HI-STORM Umax CoC Amendments 0, 1, and 2 ML24065A0152024-02-28028 February 2024 Generation Station Units 1, 2 and 3, Annual Radioactive Effluent Release Report for Independent Spent Fuel Storage Installation 2023 ML24044A0812024-02-14014 February 2024 LTR-24-0008: NRC Response to Paul Blanch Email Safety of Spent Nuclear Fuel at SONGS ISFSI IR 05000361/20240012024-02-13013 February 2024 NRC Inspection Report 050-00361/2024-001 and 050-00362/2024-001 (1) ML24031A6602024-01-31031 January 2024 International, Submittal of Rsi Responses for Revision to HI-STORM Umax CoC Amendments 0, 1, and 2 ML24037A0542024-01-30030 January 2024 (Songs), Units 2 and 3, Submittal of Annual Corporate Financial Reports ML24022A1492024-01-17017 January 2024 Independent Spent Fuel Storage Installation, Revision 4 to the Physical Security Plan ML24017A2432024-01-15015 January 2024 LTR-24-0008 Paul Blanch, E-mails Request for Formal Response to Requests for Meeting to Discuss Safety Issues with NRC Staff ML23317A1232023-12-18018 December 2023 Application for Revision to Amendment Nos. 0, 1, and 2 of the Certificate of Compliance No. 1040 for the HI-STORM Umax Canister Storage System - Supplemental Information Needed ML23348A3022023-12-14014 December 2023 International HI-STORM Umax Amendment 5 Submittal IR 05000361/20230062023-11-29029 November 2023 NRC Inspection Report 05000361/2023-006 and 05000362/2023-006 ML23333A0682023-11-22022 November 2023 (SONGS) Units 1, 2, 3 and Independent Spent Fuel Storage Installation - Notification of Change in Nuclear Officer IR 05000361/20230052023-10-11011 October 2023 NRC Inspection Report 05000361/2023005 and 05000362/2023005 ML23276A5942023-09-28028 September 2023 and Independent Spent Fuel Storage Installation - Supplement to Decommissioning Funding Status Reports ML23268A0922023-09-20020 September 2023 Generation Station, Units 1, 2 and 3, and the Independent Spent Fuel Storage Facility (ISFSI) - Re-Registration of Dry Fuel Storage Casks for Amended Certificate of Compliance No. 1040 IR 05000361/20230012023-09-13013 September 2023 NRC Inspection Report 05000361 2023-001 and 05000362 2023-004 ML23168A0042023-08-24024 August 2023 Application for HI-STORM Umax Amendment No. 3 Acknowledgement of Withdrawal and Notification of the U.S. Nuclear Regulatory Commission Staff Efforts Closure - Cost Activity Code/Enterprise Project Identification Number 001028/L-2017-LLA-003 ML23240A5372023-08-18018 August 2023 Confirmatory Survey Activities Summary and Results for the Unit 2 and 3 Intake Structures at the San Onofre Nuclear Generating Station San Clemente CA ML23129A1802023-06-14014 June 2023 Cover Letter to State of CA on Draft EA Regarding San Onofre ISFSI Updated DFPs ML23160A2542023-06-0909 June 2023 International, Temporary Withdrawal of Application for HI-STORM Umax Amendment 3 IR 05000361/20230032023-05-31031 May 2023 NRC Inspection Report 05000361/2023003 and 05000362/2023003 IR 05000361/20230022023-05-23023 May 2023 NRC Inspection Report 05000361/2023-002 and 05000362/2023-002 ML23137A1032023-05-11011 May 2023 (Songs), Units 1, 2 and 3, and Independent Spent Fuel Storage Installation - 2022 Annual Radiological Environmental Operating Report 2024-09-18
[Table view] |
Text
Al Bates Manager, Regulatory Affairs An I'illlSON INTERNATIONAL,g, Company August 4, 2020 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Docket Nos. 50-206, 50-361, 50-362, 72-41, and 72-1040 Registration of Dry Fuel Storage Canister San Onofre Nuclear Generation Station Units 1, 2 and 3 And Independent Spent Fuel Storage Facility (ISFSI)
Dear Sir or Madam:
In accordance with the registration requirements given in 10 CFR § 72.212(b)(2),
Southern California Edison (SCE) hereby submits the following registration information for three canisters used for the storage of spent fuel at the Independent Spent Fuel Storage Installation of the San Onofre Nuclear Generating Station (SONGS).
Canister #1 Licensees' Name: Southern California Edison Company San Diego Gas & Electric Company City of Anaheim, California City of Riverside, California Licensee's Address: 5000 Pacific Coast Highway San Clemente, CA 92672 Reactor License Numbers: DPR-13 (SONGS-1)
/Jf'-15S2D NPF-10 (SONGS-2)
NPF-15 (SONGS-3) f\Jtvl S 5 -z_!,a Docket Numbers: 50-206 {SONGS-1) ;Jlll 50-361 (SONGS-2) 50-362 (SONGS-3)
/JM.55 72-41 (SONGS ISFSI)
Contact Name and
Title:
Albert Bates, Manager, Regulatory Affairs Cask Certificate No: Certificate of Compliance No. 1040, Amendment 2, January 9, 2017
- Cask Model: HI-STORM UMAX Canister Storage System, MPC- 37 Cask Identification Nos.: Multi-Purpose Canister (MPC) Serial No.: 106 Cavity Enclosure Container (CEC) Serial No.: 0074 Canister# 2 Licensees' Name: Southern California Edison Company San Diego Gas & Electric Company City of Anaheim, California City of Riverside, California Licensee's Address: 5000 Pacific Coast Highway San Clemente, CA 92672 Reactor License Numbers: DPR-13 (SONGS-1)
NPF-10 (SONGS-2)
NPF-15 (SONGS-3)
Docket Numbers: 50-206 {SONGS-1) 50-361 (SONGS-2) 50-362 (SONGS-3) 72-41 (SONGS ISFSI)
Contact Name and
Title:
Albert Bates, Manager, Regulatory Affairs Cask Certificate No: Certificate of Compliance No. 1040, Amendment 2, January 9, 2017 Cask Model: HI-STORM UMAX Canister Storage System, MPC-37 Cask Identification Nos.: Multi-Purpose Canister (MPC) Serial No.: 087 Cavity Enclosure Container (CEC) Serial No.: 0098 Canister# 3 Licensees' Name: Southern California Edison Company San Diego Gas & Electric Company City of Anaheim, California City of Riverside, California Licensee's Address: 5000 Pacific Coast Highway
,San Clemente, CA 92672 Reactor License Numbers: DPR-13 (SONGS-1)
NPF-10 (SONGS-2)
NPF-15 (SONGS-3)
Docket Numbers: 50-206 {SONGS-1) 50-361 (SONGS-2) .
50-362 (SONGS-3) 72-41 (SONGS ISFSI)
Contact Name and
Title:
Albert Bates, Manager, Regulatory Affairs Cask Certificate No: Certificate of Compliance No. 1040, Amendment 2, January 9, 2017 Cask Model: HI-STORM UMAX Canister Storage System, MPC-37 Cask Identification Nos.: Multi-Purpose Canister (MPC) Serial No.: 070 Cavity Enclosure Container (CEC) Serial No.: 0079 There are no commitments in this letter.
For additional information concerning the storage of spent fuel under this general license, please contact me at 949-368-6945.
Sincerely,
()Mffi-ef cc: S. A. Morris, Regional Administrator, NRC Region IV A. M. Snyder, NRC Project Manager, SONGS Units 1, 2, and 3