Forwards RAI Re GL 92-01,Rev 1,Suppl 1, Reactor Vessel Structural Integrity in May 1995.GL Requested Licensee to Perform Review of RPV Structural Integrity Assessments to Identify,Collect & Rept Any Data Pertinent to Analysis
ML20217Q574
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/08/1998
From: William Reckley
NRC (Affiliation Not Assigned)
To: Hutchinson C
ENTERGY OPERATIONS, INC.
References
GL-92-01, GL-92-1, TAC-MA0523, TAC-MA523, NUDOCS 9804130033
Download: ML20217Q574 (10)


Text

1 S 31 )

ur UNITED STATES y!

j NUCLEAR REGULATORY COMMISSION 2

WASHINGTON. D.C. enman -t

~s

/

April 8, 1998 i

i l

Mr. C. Randy Hutetunson j

j Vice President, Operations ANO Entergy Operations, Inc.

1448 S. R. 333

{

Russellville, AR 72801 4

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING REACTOR PRESSURE VESSEL INTEGRITY AT ARKANSAS NUCLEAR ONE, UNIT 1 (TAC NO. MA0523)

Dear Mr. Hutchinson:

Generic Letter (GL) 92-01, Revision 1, Supplement 1 (GL 92-01, Rev.1, Supp.1), " Reactor l

Vesse! Structural Integrity" was issued in May 1995. This GL requested licensees to perform a

[

review of their reactor pressure vessel (RPV) structural integrity assessments in order to identify, l

collect, and report any new data pertinent to the analysis of the structuralintegrity of their RPVs and to assess the impact of those data on their RPV integrity analyses relative to the requirements of Section 50.60 of Title 10 of the Code of Federal Reaulations (10 CFR Part j

50.60),10 CFR 50.61, Appendices G and H to 10 CFR Part 50 (which encompass pressurized thermal shock (PTS) and upper shelf energy (USE) evaluations), and any potential impact on low j

temperature overpressure (LTOP) limits or pressure-temperature (PT) limits.

l After reviewing your response, the NRC issued you a letter dated August 27,1996, for Arkansas Nuclear One, Unit 1. In this letter the NRC requested, in part, that you provide an assessment of the application of the ratio procedure, as described in Position 2.1 of Regulatory Guide 1.99, Revision 2, to your PT limits curves and LTOP limits.

Subsequent to issuing this letter, the NRC conducted an inspection of Framatome Technologies, Inc. (FTI) in May 1997. This inspection focused on obtaining all available RPV weld chemistry data for RPVs fabricated by B&W. As a result of this inspection, additional data were identified which may affect previous RPV integrity analyses supplied by licensees with B&W fabricated RPVs.

As a follow-up to the letter and the FTl inspection, and in order to provide a complete response to items 2,3 and 4 of the GL, the NRC requests that you provide a response to the enclosed request for additionalinformation within 90 days of receipt of this letter. This response should include application of the ratio procedure in the assessment of surveillance data from welds. If a question does not apply to your situation, please indicate this in your RAI response along with your technical basis and, per GL 92-01, Rev.1, Supp.1, provide a certification that previously submitted evaluations remain valid.

\\

i

_ a:-

9804130033 980408 l

PDR ADOCK 05000313 P

PDR NRC FILF CENTER CDPV

e-

~

^

p Mr. C. Randy Hutchinson

, o r

,3 The information provided will be used in updating the Reactor Vessel Integrity Database (RVID).'

Also, please note that RPV integrity analyses utilizing newly identified data could result in the need for license amendments in order to maintain compliance with 10 CFR Part 50.60,10 CFR 50.61 (pressurized thermal shock, PTS), and Appendices G and H to 10 CFR Part 50, and to L

address any potential impact on low temperature overpressure (LTOP) limits or pressure-l temperature (PT) limits. If additionallicense amendments or assessments are necessary, the l

attached requests that you provide a schedule for such submittals.

Please contact me if you have any questions regarding this request for information.

Sincerely, l

ORIGIN 4l. SIGNED BY:

l William Reckley, Project Manager Project Directorate IV-1 Division of Reactor Projects Ill/IV b-Office of Nuclear Reactor Regulation -

Docket No. 50-313 l-

Enclosure:

= As stated l

cc w/ encl: See next page L

l l

L

' DISTRIBUTION:

Docket File.

PUBLIC PD4-1 r/f OGC-

- CHawes WReckley ACRS GVissing TGwynn, RIV -

EAdensam (EGA1)

JHannon AHiser, Jr.

l-Document Name: AR1A0523.RAI r

-l OFC PM/PD4-1A LA/PD4-1 PD/PDlW WReckih/vw -CHNs '

NAME J.Harpe, x

E ) /98 h 8/98 klh/k DATE l

YESkh)-

COPY YES/NO YES/NO -

OFFICIAL RECORD COPY U

Mr. C. Randy Hutchinson ~

'2-i The information provided will be used in upda2ng the Reactor Vessel Integrity Database (RVID).

- Also, please note that RPV integrity analyses utilizing newly identified data could result in the need for license amendments in order to maintain compliance with 10 CFR Part 50.60,10 CFR 50.61 (pressurized thermal shock, PTS), and Appendices G and H to 10 CFR Part 50, and to address any potential impact on low temperature overpressure (LTOP) limits or pressure-l temperature (PT) limits. If additionallicense amendments or assessments are necessary, the l

attached requests that you provide a schedule for such submittals.

Please contact me if you have any questions regarding this request for information.

Sincerely, i

William Reckley, Project Ma r-I Project Directorate IV-1 Division of Reactor Projects Ill/IV-Office of Nuclear Reactor Regulation Docket No. 50-313

Enclosure:

As stated cc w/ encl:' See next page I

l l

]

l l

Mr. C. Randy Hutchinson -

Entergy Operations, Inc.

Arkansas Nuclear One, Unit 1 l

l cc:

l Executive Vice President Vice President, Operations Support l

& Chief Operating Officer Entergy Operations, Inc.

l Entergy Operations, Inc.

P. O. Box 31995 l

P. O. Box 31995 Jackson, MS 39286-1995 Jackson, MS 39286-199 Wise, Carter, Child & Caraway Director, Division of Par.~an P. O. Box 651 l

l Control and Emergency Management Jackson, MS 39205 Arkansas Department of Health 4815 West Markham Street, Slot 30 Little Rock, AR 72205-3867 l

Winston & Strawn 1400 L Street, N.W.

Wa'shirigton, DC 20005-3502 Manager, Rockville Nuclear Licensing Framatone Technologies 1700 Rockville Pike, Suite 525 Rockville, MD 20852 Senior Resident inspector U.S. Nuclear Regulatory Cornmission P. O. Box 310 London, AR 72847 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 County Judge of Pope County Pope County Courthouse Russellville, AR 72801 i

REQUEST FOR ADDITIONAL INFORMATION REACTOR PRESSURE VESSEL INTEGRITY l

Section 1.0: Assessment of Best-Estimate Chemistry.

The staff recently received additionalinformation that may affect the determination of the best-estimate chemistry composition for your RPV welds or your surveillance weld material. This data was provided by FTl in letters from Mr. Matthew J. DeVan (FTI) to Mr. Barry J. Elliot (NRC) dated June 6 (INS-97-2262), June 19 (INS-97-2450), and July 10,1997 (INS-97-2741). In addition, it is the NRC staffs understanding that an evaluation of this data was provided to member:; of the B&W Owner's Group, Mr. R. E. Jaquin (Rochester Gar 7d Electric), and Mr. P. S. Askins (Tennessee Valley Authority) via letter dated June 30,1W7 (INS-97-2526).

Based on this information, in accordance with the provisions of Generic Letter 92-01, Revision 1, Supplement 1, the NRC requests the following:

1.

An evaluation of the information in the references above and an assessment of its applicability to the determination of the best-estimate chemistry for all of your RPV beltline welds. Based upon this reevaluation, supply the information necessary to completely fill out the data requested in Ta' le 1 for each RPV beltline weld material. Also provide a a

discussion for the copper and nickel values chosen for each weld wire heat noting what heat-specific data were irecluded and excluded from the analysis and the analysis method chosen for determining the best-estimate. If the limiting material for your vessel's PTS /PT limits evaluation is not a weld, include the information requested in Table 1 for the limiting material also. Furthermore, you should consider the information provided in Section 2.0 of this RAI on the use of surveillance data when responding.

With respect to your response to this question, the staff notes that some issues regarding the -

evaluation of the data were discussed in a public meeting between the staff, NEl, and industry representatives on November 12,1997. A summary of this meeting is documented in a meeting summary dated November 19,1997, " Meeting Summary for November 12,1997, Meeting with l-Owners Group Representatives and NEl Regarding Review of Responses to Generic Letter 92-01, Revision 1, Supplement 1 Responses"(Reference 1). The information in Reference 1 may be useful in helping you to prepare your response.

in addition to the issues discussed in the referenced meeting, you should also consider what method should be used for grouping sets of chemistry data (in particular, those from weld qualification tests) as being from *'one weld" or from multiple welds. This is an important consideration when a mean-of-the-means or coil-weighted average approach is determined to be the appropriate method for determining the best-estimate chemistry. If a weld (or welds) were L

fabricated as weld qualification specimens by the same manufacturer, within a short time span, using similar welding input parameters, and using the same coil (or coils in the case of tandem

, arc welds) of weld consumables, it may be appropriate to consider all chemistry ENCLOSURE 1^

l t

i:

. i 2

j samples from that ' weld (or welds) as samples frem'"one weld" for the purposes of best-estimate chemistry determination. If information is not available to confirm the aforementioned details, but sufficient evidence exists to reasonably assume the details are the same, the best-estimate chemistry should be evaluated both by assuming the data came from "one weld" and by 1

. assuming that the data came from an appropriate number of" multiple welds". A justification i

should then be provided for which assumption was chosen when the best-estimate chemistry l

was determined.

i Section 2,0: Evaluation and Use of Surveillance Data i

The chemical composition reports referenced in Sechon 1.0 include updated chemistry estimates

. for heats of wold metal. These reports provide information regarding a best estimate value and the source of the data used in estimating the chemical composition of the heat of material. This permits tho' determination of the best estimate chemical composition for the various sources of data including surveillance welds. Since the evaluation of surveillance data rely on both the best estimaf.e chemical composition of the RPV weld and the surveillance weld, the information in these reports may result in the need to revise previous evaluations of RPV integrity (including LTOP setpoints and PT limits) per the requirements of 10 CFR 50.60,10 CFR 50.61, and Appendices G and H to 10 CFR Part 50.

- Based on this information and consistent with the provisions of Generic Letter 92-01, Revision 1, l.

Supplement 1, the NRC requests the following:

2.

that (1) the information listed in Table 2, Table 3, and the chemistry factor from the j

surveillance data be provided for each heat of material for which surveillance weld data are available 10d a revision in the RPV integrity analyses (i.e., current licensing basis) is l

needed or (2) a certification that previously submitted evaluations remain valid. Separate i

tables should be used for each heat of material addressed. If the limiting material for your vessel's PTS /PT limits evaluation is not a weld, include the information requested in the

.j tables for the limiting material (if surveillance data are available for this material).

j The information discussed in Section 1.0 of this RAI regarding the chemistry reports should be I

considered in this response along with the following questions and comments.

1 l

All surveillance program results for the heats of materialin a RPV should be considered in I

evaluating its integrity regardless of source per 10 CFR 50.61 (" Surveillance program results means any data that demonstrates the embrittlement trends for the limiting beltline material, i

including but not limited to data from test reactors or from surveillance programs at other plants with orwithout surveillance progi am integrated per 10 CFR 50, Appendix H."). If any of the data provided in Table 2 are not used in the calculation of the embrittlement trend for a particular RPV weld, the technical basis for not including /using the data should be provided, i

When assessing credibility of surveillance data that come from more than one source, 1

adjustments to the surveillance data may be needed to account for differences in the chemical composition and irradiation environment of the different sources consistent with the requirements in 10 CFR 50.61. A method for accounting for these differences is discussed in Reference 1.

1 I-3-

Based on the information provided in Table 2, the credibnity of the surveillance data can be

. evaluated. The results of these anayses including the slope of the best fit line through the surveillance data can be provided in a format similar to that of Table 3. If the method for adjusting and/or normalizing the surveillance data when assessing credibility differ from the methods documented in Reference 1, provide the technical basis for the adjustment and/or the normalization procedure. If the chemical composition of the surveillance weld is not determined

~ in accordance with Reference 1 (i.e., the mean of all chemistry analyses performed on the surveillance weld), provide the technical basis for the estimate.

When determining the chemistry factor for a RPV weld from surveillance data, adjustments to the surveillance data may be needed to account for differences in the chemical composition and irradiation environment between the surveillance specimens and the vessel being assessed consistent with the requirements in 10 CFR 50.61. A method to account for these differences is provided in Reference 1.

L j

in addition,10 CFR 50.61(c)(2) specifies that licensees shall consider plant-specific information j

(e.g., operat'ng temperature and surveillance data) to verify that the RTa for each vessel beltline materialis a bounding value. Regulatory Guide 1.99, Revision 2 describes two methods l

for determining the amount of margin and the chemistry factor used in determining RT e.

L Position 1.1 describes the use of the Generic Tables in the Regulatory Guide. Position 2.1 R

describes the use of credible surveillance data.~ if the surveillance data are credible, the 0 may 3

be reduced in half to calculate the margin term and the chemistry factor is to be determined from the best-fit line of the surveillance data. If the evaluation of the surveillance data indicate that the E

surveillance data set is not credible and the measured values of ART, are less than the projected mean from the Tables plus the generic 20, the chemistry factor may be calculated 4

. using either Position 1.1 or Position 2.1; however, the full margin term must be applied. The l

' method chosen must bound all the surveillance data to be in compliance with 10 CFR l

50.61(c)(2).

l-Based on the information provided in Table 2 along w5th the best estimate chemical composition of the heat of material and the irradiation temperature of the plant whose vessel is being assessed, the chemistry factor of the RPV weld can be determined. l Note that the adjusted ART for a particular surveillance data point may be one value when determining credibility and 1.

another value when determining the chemistry factor as a result of the different normalization l'

procedures.. lf the method for adjusting and/or normalizing the surveillance data when I

E determining the chemistry factor differs from the methods documented in Reference 1, provide the technical basis for the adjustment and/or the normalization procedure.

L

_ in a meeting between the staff and industry representatives at the NRC on February 12,1998, an industry representative requested a clarification as to when the ratio procedure should be used to evaluate surveillance data. The ratio procedure is described in the PTS rule and RG 1.99, Revision 2. The ratio procedure is used to adjust the measured value of ARTa to account for differences in the chemical composition between the surveillance weld and the vessel beltline wold. The PTS rule and RG 1.99, Revision 2 indicate that when there is clear evidence that the copper and nickel content of the surveillance weld differs from the vessel weld, i.e. differs from

)

' the average for the weld wire heat number associated with the vessel weld and the surveillance i

weld, the ratio procedure must be used, i

j.

L L-1

-4 l

4 f

I Section 3.0: PTS /PT Limit Evaluation 3.

If the limiting material for your plant changes or if the adjusted reference temperature for the limiting materialincreases as a result of the above evaluations, provide the revised RTets value for the limiting material in accordance with 10 CFR 50.61, in addition, if the i

adjusted RT,or value increased, provide a schedule for revising the PT and LTOP limits.

The schedule should ensure that compliance with 10 CFR 50 Appendix G is maintained.

Reference 1.

Memorandum fn>m Keith R. Wichman to Edmund J. Sullivan, " Meeting Summary for November 12,1997, Meeting with Owners Group Representatives and NEl Regarding Review of Responses to Generic Letter 92-01, Revision 1, Supplement 1 Responses",

dated November 19,1997.

Attachments: 1. Table 1

2. Tables 2,3 i

l 1

I

s n

T L R O rE o

t Ta RA n

ig ra M

o, ls o,

a ir e

t r

a o

M T,d r

g R o in a T, l

)

it iR 1

m i

it

(

L In(

0 r

1 o

/

n d

g io f

n oi t

n t

n c

a a

d diA e

e omF S

H 1

le hrC e

n e

E W

et i

r t

L i

B V

Me d

W D

e A

P t

d T

R s

l e

e W

u n

)

dl yF q

o d

eatrC e

h r

e nis(

c ri s

a gemr a

t se saet l

E it o

u sMhc a

r ia o

A Ca q

r f

e F

et r

t a d

ad e

no me s

c U

De9 gn ita c

n a

I m

L n0 i a t

e1 a

n o

Ou it ~

D io r

n ime f

elf (x l

r d

s v

eu n

s I

hs a

uc t

m d

is e

f o

D o o t

l h

ae r

t nf t

smk eic ior e

i t o M

BtsN a

c s s

E i e is f

l it b ly n a et a

r e r n

r t a e dm A

e t

i u

smp ar e

o l

ei p tc if h

t a

Bt o r

t a

sC ed t

f e

f E

u a e o

H n

n mi n

e a

m io i

e er

- M r

r W

VWm i

he s

yl t t s

t e t

re u

i l

s P

a od c

ld i

d cs Rl e s

e ae eH 12 D

W

))

i FV W

((

> M!s.

r f

l Table 2: Heat xxxx Capsule ID Cu Ni IWrm Fluence Measured Date Used in (including Temperature (x10"rvem')

ART.

Assessing Vessel source)

(*F)

(*F)

(Y v N) t i

l i

i i

i j

i l

Table 3: Heat xxxx l

Capsule ID Cu Ni irredation Fluence -

Measured Adjusted Predcted (Adjusted.

l (including Temperature Factor ART.

ART.

ART.

Predicted) ART, source)

(*F)

(*F)

(*F)

(*F)

(*F) l t

1 I

i l

i i

ATTACHMENT 2 t

l t