Text
s USEC A Global Energy Company GEORGE P. RIFAKES Dir: (401) 664-3301 EXECUTIVE VICE PRESIDENT, OPERATIONS Fax:(301) 664 3208 April 1,1998 :
GDP 98-0066 Dr. Carl J. Paperiello Director, Office of Nuclear Material Safety and Safeguards Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Paducah Gaseous Diffusion Plant (PGDP)
Docket No. 70-700I Postulated Scismic Failures in C-310/310-A and C-315 - Consent to Confirmatory Order
Dear Dr. Paperiello:
Enclosed, in accordance with the referenced letter, is a signed Written Response Waiver to the NRC's proposed Confirmatory Order Modifying Certificate in the form provided to USEC by the l
NRC.
l Should you have any questions regarding this subject, please contact Steve Routh at (301) 564-3251.
l There are no new commitments contained in this submittal.
i Sincerely, George P. Rifakes Executive Vice President, Operations
Enclosure:
Written Response Waiver
\\\\
Reference:
Letter from Carl J. Paperiello (NRC) to Mr. James H. Miller (USEC), " Consent to Confirmatory Order," March 27,1998.
D O
9804090059 900401 PDR ADOCK 07007001 s., u.s. a v 6903 Rockledge Drive. Bethesda, MD 20817-1818 Telephone 301-564-3200 Fax 301-564-3201 http://www.usec.com
. Offices in Livermore. CA Paducah, KY Portsmouth, OH Washington. DC
l.-
i Dr. Carl J. Paperiello April 1,1998 GDP 98-0066, Page 2 cc: Mr. Robert C. Pierson, NRC NRC Region III Office NRC Resident inspector - PORTS NRC Resident Inspector - PGDP Mr. Randall M. DeVault, DOE i
)
i l
l l
..i 8
WRITTEN RESPONSE WAIVER 1, George P. Rifakes, Executive Vice President, Operations, United States Enrichment Corporation, hereby agree to comply with the commitments described in the Nuclear Regulatory.
Commission's (N'RC's) letter dated March 27,1998, and agree to incorporating the commitments into a Confumatory Order Modifying Certificate that will be effective upon issuance. I recognize by signing below, I consent to the issuance of a Confirmatory Order Modifying Certificate with the commitments described in NRC's letter dated March 27,1998, and, by doing so, pursuant to 10 CFR
.76.70. I will not hr e a rigia to submit a written respon te to this Order.
l WO-
'tb[W i
/ George /P. Rifakes Date l
Executive Vice President.
. United States Enrichment Corporation l
1 1
i 1
.