Text
_____ __ -_ - _____--_-_- ---- - - - -
Document Transmittil C: 71201 Date: 10/13/97 To:
NRC (DC DESK)
MAC: N/A Destination:
==
Description:==
Copy Copy Totals Documerit:
Revision:
Comment:
INFO CNTL MSTR AR0401 17 24 1
0 0
l l
l l
l.
I
\\'f' Instructims to the Addressee:
Please verify i.he document (s) received a0rees with the above information.
Operations department must attach old document (s) or portions of document (s) superseded by the above to this transmittal.
The signature indicates acknowledgment of receipt of the above document (s) and that documents have be:n updated. Retum signed and dated transmittal to Document Control within 15 working days of transmittal date to mail code:
NA1C Florida Power Corporation l gHjll]{
Document Control, NA1C
[ 1,ullitillilii ic Crystal RNer Energy complex 15760 W. Power Line st.
Crystal RNer, FL 34428-6708 4 3 n rs --
...i t. (.J Signature of Addressee:
Date:
9710220239 971013 hDR ADOCK 05000302 PDR
p Rev. 17 EffectiveDate/O-!
l INFORMATION ONLY 1
i l
ANNUNCIATOR RESPONSE AR-401 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3
,(}
PSA F ANNUNCIATOR RESPONSE
\\._s APPROVED BY: Interpretati on Contact N$i It5U (SIGNATURE'ONFI [
OV DATE:
/A//!97 INTERPRETATION CONTACT: Manager, Nuclear Plant Operations Support 1
. -.. _ ~ _. _. -..
_ =. -
i I
I TABLE OF CONTENTS SECTION PAGE s
?
1.0 PURP0SE.................................................................
1 2.0 REFERENCE;S..............................................................
1 1
2.1 IMPLEMENTING REFERENCES.............................................
1 i
2.2. DEVELOPMENTAL REFERENCES............................................
1 a
3.0 PERSONNEL INDOCTRINAT1.QN...............................................,,1
{
4.0 INSTRUCTIONS............................................................
2 5.0 FOLLOW-UP ACTIONS.......................................................
2 ENCLOSURES 1.
Annunciator Response............................................... 3 4
s 9
4 4
i O'3 AR-401 Rev. 17 Page i
d J.0 -
PUR20SE A.A 1.1 -
l Establish.a reference = document for each Annunciator Window on the PSA-X Lampbox.
- 1. 2 Establish operator status for' valid Annunciator alarms on the PSA-X Lampbox.
1,3-Establish a reference ~ to other procedures wiiirh address operator actions for valid Annunciator alarms on the PSA-X Lampbox, t
2.0 REFERENCES
2.1 hMPLEMENTINGREFERENCES s
I 2.1.1 OP-409 - Plant Ventilation 2.1.2 OP-417 - Containment Operating Procedure-2.1.3-OP-703 - Plant Distribution System -
2.1. 4 -
AP-250 - Radiation Monitor Actuation OV 2.1.5
-AP-513 - Toxic Gas 2.1.6 AP-880 - Fire Protection 2.1.7 OP-417A - Industrial Cooling System I
[7 2.1.8 SP-300 - Operating Daily Surveillance Log 2.1.9 PM-194 - Calibrat on of Robert Shaw Vibra Switches i
2.2 DEVELOPMENTAL REFERENCES 2.2.1
.INPO 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Annunciator Window Engraving Drawing E-224-048 3.0 PERSONNEL' INDOCTRINATION 3.1-The Annunciator System is powered from VBDP-5 Breaker 28.
O AR-401 Rev. 17 Page 1
4.0 INSTRUCTIONS U
4.1 Respond to alarms on the PSA-X Lampbox as indicated on Enclosure 1, Annunciator Response.
5.0 FOLLOW-UP ACTIONS None 1
1 OV O
AR-401 Rev. 17 Page 2
'w
[
ENCLOSURE 1 (Page 1 of 185)
PSA ANN'JNCIATOR RESPONSE PSA-X-01-01 F-01-01.
l l
l l
CNTRL COMPLEX l
1 FAN I
I l
I TRIP I
i I
I EVENT POINT 0466 INDICATED CONDITION:
AHF-17A MOTOR IS NOT ENERGIZED WITH CONTROL-HANDLE IN NORMAL AFTER START o
POSITION O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT-ON WITH A RED FLAG ON CONTROL STATION o
RADIATION HIGH RAD ALARM RM-A-5 o
1 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o START-AHF-178
.o RESTORE. VENTILATION PER OP-409 o REFER TO AP-250 DISCUSSION:
4 2
REFERENCES:
DRAWING 208-005 SHEET AH-80 J
SENSING ELEMENT:
CS/SC, CS/0.-42B AR-401 Rev. 17 Page 3 l
_u
ENCLOSURE 1 (Page 2-of 185)
PSA ANNUNCIATOR RESPONSE-PSA-X-01-01 F-01-01 l
l l
l i
CNTRL COMPLEX I
I FAN l
I TRIP i
l-1 I
t" L
l EVENT POINT 0467 INDICATED CONDITION:
o-AHF-178 MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START POSITION AQ REDONDANT INDICATION WHICH WILL VERIFY ALARM:
CREEN LIGHT ON WITH A RED FLAG ON CONTROL STATION o
o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o REFER TO AP-250 o START AHF-17A o RESTORE VENTILATION PER OP-409 DISCUSSION:
s
REFERENCES:
DRAWING 208-005 SHEET AH-81
/~T SENSING ELEMENT: CS/SC, CS/0, 42B Q
~
AR-401 Rev. 17 Page 4
1 7 ENCLOSURE 1 (Page 3 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 s
e I
I I
I CNTRL COMPLEX-FAN l
l TRIP l
I I
l EVENT POINT 0470 INDICATED CONDITION:
AHF-18A MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START o
POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-18A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
l o INVESTIGATE THE CAUSE OF TRIP o START AHF-188 o RESTORE VENTILATION PER OP-409 DISCUSSION:
REFER TO TECH SPECS FOR ADMINISTRATIVE REQUIREMENTS.
p
REFERENCES:
DRAWING 208-005 SHEET AH-82 l-SENSING ELEMENT:- CS/SC, CS/0, 428 AR-401 Rev. 17 Page 5
._ _ ~.
.. _ ~
n ENCLOSURE 1 (Page 4 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
I I
I CNTRL COMPLEX FAN l
l TRIP 1
I I
I EVENT POINT 0471 INDICATED CONDITION:
7 a
AHF-18B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER o
START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT ON WITH A RED F1.AG ON AHF-188 CONTROL STATION o
OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE.0F TRIP o START AHF-18A o RESTORE VENTILATION PER OP-409 DISCUSSION:
REFER'TO TECH SPECS FOR ADMINISTRATIVE REQUIREMENTS
REFERENCES:
-DRAWING 208-005 SHEET AH-83 SENSING ELEMENTi CS/SC, CS/0, 42B AR-401 Rev. 17 Page 6
,7 ENCLOSURE 1 (Page 5 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 I
I I
CNTRL COMPLEX L
I I
FAN I
TRIP l
l 1
I I
l EVENT POINT 0478 INDICATED CONDITION:
AHF-19A MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START o
POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT ON WITH A RED FLAG ON AHF-19A CONTROL STATION o
o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS'FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o REFER TO AP-250-o START AHF-19B o RESTORE VENTILATION PER OP-409 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-86 SENSING ELEMENT:
CS/SC, CS/0, 42B AR-401 Rev. 17 Page 7
ENCLOSURE 1 (page 6 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
l CNTRL COMPLEX 1
I FAN I
TRIP I
.I I
EVENT POINT 0479 l
l INDICATED CONDITION:
AHF-198 MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START o
POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
CREEN LIGHT ON WITH A RED FLAG ON AHF-19B CONTROL STATION o
o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o START AHF-19A o RESTORE VENTILATION PER OP-409 o REFER TO AP-250 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-87 SENSING-ELEMENT: CS/SC, C3/0, 42B AR-401 Rev. 17 Page 8
ENCLOSURE 1 (Page 7 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
L pup-----
l
.l CNTRL COMPLEX l
l-FAN I
l TRIP l
l l
I I
I
-l EVENT POINT 0482 INDICATED CONDITION:
AHF-20A MOTOR FAST SPEED WINDINGS ARE NOT ENERGIZED, CONTROL HANDLE IN o
THE PUSHED IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN FAST SPEED LIGHT ON WITH A RED FLAG ON AHF-20A CONTROL STATION o
o RADIATION HIGH RAD ALARM RM-A-5 i
o T0XIC GAS ACTUATION OPERATOR ACTIONS FOR A VALID ALARM:
,o INVESTIGATE THE CAUSE OF TRIP NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o
~o REFER TO OP-409 o REFER TO AP-250 OR AP-513 DISCUSSION:
IT MAY BE POSSIBLE TO OPERATE AHF-20A/B IN SLOW SPEED WITH AHF-44A/B IN OPERATION-T0 PROVIDE CHEMISTRY SAMPLE HOOD VENTILATION
REFERENCES:
DRAWING 208-005 SHEET AH-88 SENSING ELEMENT: CS/SC, CS/0, NC/LAT, 428 AR-401 Rev. 17 Page 9
ENCLOSURE 1 i
(Page 8 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
CNTRL COMPLEX l
FAN I
6 1
TRIP 1
4 I
L EVENT POINT 0483 t-INDICATED CONDITION:
o AHF-20A MOTOR SLOW SPEED WINDINGS ARE NOT ENERGIZED, CONTROL = HANDLE IN THE PULLED OUT NORMAL AFTER START POSITION
,(m]
REDUNDANT INDICATION WHICH NILL VERIFY ALARM:
GREEN SLOW SPEED LIGHT ON WITH A RED FLAG ON AHF-20A CONTROL STATION o
1 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o
o REFER TO OP-409 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-88 A-()
SENSING ELEMENT: CS/SC, CS/0, NC/LAT, 42B AR-401 Rev. 17 Page 10
ENCLOSURE 1
'O (Page 9 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
l l
I CNTRL COMPLEX FAN I
I l
I TRIP I
I I
I EVENT POINT 0484 INDICATED CONDITION:
AHF-20B MOTOR FAST SPEED WINDINGS ARE NOT ENERGIZED, CONTROL HANDLE IN o
THE PUSHED IN NOP. MAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN FAST SPEED LIGHT ON WITH A RED FLAG ON AHF-208 CONTROL STATION o
o RADIATION HIGH RAD ALARM RM-A-5 o T0XIC GAS ACTUATION OPERATOR ACTIONS FOR A VALID ALARM:
i o INVESTIGATE THE CAUSE OF TRIP NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o
o REFER TO OP-409 o REFER TO AP-250 OR AP-513 DISCUSSION:
IT.MAY BE POSSIBLE TO OPERATE AHF-20A/B IN SLOW SPEED WITH AHF-44A/B IN OPERATION TO PROVIDE CHEMISTRY SAMPLE HOOD VENTILATION REFERENCEb DRAWING 208-005 SHEET AH-89 SENSING ELEMENT:
CS/SC, CS/0, NC/LAT, 428 r
AR-401 Rev. 17 Page 11 l
i
(
ENCLOSURE 1 (Page 10 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
l CNTRL COMPLEX l
I FAN I
I TRIP I
-l i
I 1
I EVENT POINT 0485 INDICATED CONDITION:
AHF-20B MOTOR SLOW SPEED WINDINGS ARE NOT-ENERGIZED, CONTROL HANDLE IN o
THE PULLED OUT NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o. GREEN SLOW SPEED LIGHT ON WITH A RED FLAG ON AHF-20B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS' SECURED o ' REFER TO OP-409 4
DISCUSSION:
4
REFERENCES:
DRAWING 208-005 SHEET AH-89 SENSING ELEMENT: CS/SC, CS/0, NC/LAT, 428 AR-401 Rev. 17 Page 12 r.
i l
l
[O ERCLOSURE 1 i,)
(Page 11 of 185) 1 i
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 4
4 l
l l
CNTRL COMPLEX l
j l
l FAN I
I TRIP I
I 1
I i.-.
l l
1 l
EVENT POINT 0489 l
INDICATED CONDITION!
AHF-21A MOTOR 10 NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER o
3 START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN LIGHT ON WITH A RED F8..AG ON AHF-21A CONTROL STATION o RAD.TATION HIGH RAD RM-A-5 4
o T0XIC CAS ACTUATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP i
o REFIR TO AP-250 OR AP-513 l
o START AHF-21B o RESTORE VENTILATION PER OP-409 i
i DISCUSSION:
4
REFERENCES:
DRAWING 208-005 SHEET AH-91 l
SENSING ELEMENT: CS/SC. CS/0, 428 AR-401 Rev,.17 Page 13
.,,n..,,--,
v.,,.
,-,.----,e
-._...,,.,,m.m.-,,,,,n.
a.,,m
,,..-.n,.,,,g...,n,,,
i Al ENCLOSURE 1 (Page 12 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01
%ZZZZ i
I I
CNTRL COMPLEX l
i FAN I
I l
I TRIP i_..
l l
EVENT POINT 0490 i
INDICATED CONDITION:
i i
o AHF-21B MOTOR IS NOT ENERCIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
l 0 GREEN LIGHT ON WITH A RED FLAG ON AHF-21B CONTROL STATION o RADIATION HIGH RAD RM-A-5 o T0XIC GAS ACTUATION
]
OPERATOR ACTIONS FOR A VALID ALARM:
1 o INVESTIGATE THE CAUSE OF TRIP o REFER TO AP-250 OR AP-513 o START AHF-21A o RESTORE VENTILATION PER OP-409 2
i DISCUSSION:
i 1
4
REFERENCES:
DRAWING 208-005 SHEET AH-92 SENSING ELEMENT:
CS/SC, CS/0, 42B 1
AR-401 Rev. 17 Page 14 4
y
,7.~,.-
,m,-
---,y..-
v.-,-.--
-w.
m.-
,w.
-e...,,-.w.,
-.wyr-~,.-.,
c v,,
EELQ10AL1 (Page 13 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01 l
l 1
CNTRL COMPLEX l
l FAN I
I I
I TRIP I
I I
I EVENT POINT 0491 INDICATED CONDITION:
AHF-30 MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER o
START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT ON WITH A RED FLAG ON AHF-30 CONTROL STATION o
o T0XIC GAS ACTUATION o RADIATION HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF TRIP o REFER TO 9P-409 o REFER TO AP-250 OR AP-513 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-93 SENSING ELEMENT:
CS/SC, CS/0, 428 AR-401 Rev. 17 Page 15
j 1
ENCLOSURE 1 (Page 14 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 I
4 1
I CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0308 4
4 l
INDICATED CONDITION:
l l
o AIR FLOW FROM "A" BATTERY ROOM IS LOW AS SENSED BY AH-734-FS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FIRE DAPPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
t o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION HAVE CHEMISTRY SAMPLE BATTERY ROOM FOR H, CONCENTRATIONS o
DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION, CHECK FIRE i
DAMPERS IN THE CORRECT POSITION. THIS LOSS OF FLOW FROM THE BATTERY ROOM COULD RESULT IN A BUILD UP OF HYDROGEN INSIDE THE BATTERY ROOM.
CONSIDERATION SHOULD BE GIVEN TO VENTILATING THE AREA TO PREVENT THE POSSIBILITY OF AN EXPLOSIVE MIXTURE DEVELOPING.
REFERENCES:
DRAWING 208-005 SHEET AH-131 SENSING ELEMENT: AH-734-FS d
AR-401 Rev. 17 Page 16 i
l ENCLOSURE 1 (Page 15 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 1
1 CNTRL COMPLEX AIR FLOW LOW i
i --
EVENT POINT 0309 i
INDICATED CONDITION:
j o AIR FLOW FROM "B" BATTERY ROOM IS LOW AS SENSED BY AH-735-FS 1
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION HAVE CHEMISTRY SAMPLE BATTERY ROOM FOR H, CONCENTRATIONS o
DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION. CHECK FIRE DAMPERS IN THE CORRECT POSITION. THIS LOSS OF FLOW FROM THE BATTERY ROOM COULD RESULT IN A BUILD UP OF HYDROGEN INSIDE THE BATTERY ROOM.
CONSIDERATION SHOULD BE GIVEN TO VENTILATING THE AREA TO PREVENT THE j
POSSIBILITY OF AN EXPLOSIVE MIXTURE DEVELOPING.
i l
REFERENCES:
DRAWING 208-005 SHEET AH-131 SENSING ELEMENT: AH-735-FS AR-401 Rev. 17 Page 17
.- _ -_ _ _.. ~ __ _,
.... ~..
J '
h i
MCLOSURE 1 (Page 16 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01 02 F-01-02 CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0442 INDICATED CONDITION:
AHF-16A CONTROL HANDLE IN NORMAL AFTER START, AND DIFFERENTIAL PRESSURE
_o ACROSS AHHE-10A IS <0.063"H,0 AS SENSED BY AH-123-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-16A TRIPPED o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION o START AHF-16B TO SUPPLY SWITCHGEAR ROOMS DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION, CHECK FIRE DAMPER POSITION.
REFERENCES:
DRAWING 208-005 SHEET AH-058, DRAWING 308846 SENSING ELEMENT: AH-123-DPS AR-401 Rev. 17 Page 18
EELOSURE 1 (Page 17 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0446 l
C l
INDICATED CONDITION:
l l
o AHF-16B CONTROL HANDLE IN NORMAL AFTER START, AND DIFFERENTIAL PRESSURE ACROSS AHHE-10B IS <0.050"H,0 AS SENSED BY AH-124-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-16B TRIPPED o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION o START AHF-16A TO SUPPLY SWITCHGEAR ROOMS DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION, CHECK FIRE DAMPER POSITION.
REFERENCES:
DRAWING 208-005 SHEET AH-059, DRAWING 308846 SENSING ELEMENT: AH-124-DPS i
AR-401 Rev. 17 Page 19
i
\\
l O.
ENCLOSURE 1 (Page 18 of 185)
PSA ANNUNCIATOR RESPONSE lPSA-X-01-02 F-01-02 4
i 4
i r
CNTRL COMPLEX AIR FLOW j
LOW i
i EVENT POINT 0468 INDICATED CONDITION:
AHF-17A, OR AHF-18A CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW o
CONDITION EXISTS IN DUCT WORK OF <0.15"H,0 AS SENSED BY AH-34-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOW FLOW INDICATION ON AH-32-FIR o POSSIBL2 FAN TRIP ALARMS OPERATOR ACTIONS'FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 i
DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP. OR A FLOW BLOCKAGE.
ALTERNATING VENTILATION EQUIPMENT SHOULD CORRECT THE CONDITION.
REFERENCES:
DRAWING 208-005 SHEET AH-080 DRAWING 308847 SENSING ELEMENT: AH-34-DPS AR-401 Rev. 17 Page 20
ENCLOSURE 1 (Page 19 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 CNTRL COMPLEX AIR FLOW LOW I
EVENT POINT 0480 INDICATED CONDITION:
AHF-19A CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION o
EXISTS IN DUCT WORK OF <0.10" li,0 AS SENSED BY AH-176-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o
o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP OR A FIRE DAMPER ACTUATION.
IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED,
REFERENCES:
DRAWING 208-005 SHEET AH-086, DRAWING 308847 SENSING ELEMENT: AH-176-DPS AR-401 Rev. 17 Page 21
ENCLOSURE 1 (Page 20 of 185)
=PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 i
CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0486 INDICATED CONDITION:
j-AHF-20A CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION o
EXISTS IN DULT WORK OF <0.08"H,0 AS SENSED BY AH-36-DPS REDUNDANT INifCATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o
o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.
IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.
. THIS IS AN EXPECTED ALARM WHEN AHF-20A IS BEING RUN IN SLOW SPEED.
REFERENCES:
DRAWING 208-005-SHEET AH-088, DRAWING 308847 SENSING ELEMENT: AH-36-DPS AR-401 Rev. 17 Page 22
=.
- - - -. -.. ~..
l l
fECLOSURE 1 (Page 21 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 CNTRL COMPLEX AIR FLOW L0W 1
EVENT POINT 1545 l
INDICATED CONDITION:
AHF-178, OR AHF-18B CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW o
CONDITION EXISTS IN DUCT WORK OF <0.15"H,0 AS SENSED BY AH-$46-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOW FLOW INDICATION ON AH-32-FIR l
o POSSIBLE FAN TRIP ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE TH'. CAUSE OF ALARM o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM i
o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FLOW BLOCKAGE.
ALTERNATING VENTILATION EQUIPMENT SHOULD CORRECT THE CONDITION.
l 5
REFERENCES:
- DRAWING 208-005 SHEET AH-081, DRAWING 308847 SENSING ELEMENT: ' AH-546-DPS AR-401 Rev. 17 Page 23
.-_.. ~ - - _... -. -.
)
i ENCLOSilRE 1 (Page 22 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02
)
l j
CNTRL COMPLEX AIR FLOW LOW
)
EVENT POINT 1546 f
INDICATED CONDITION:
1
)
AHF-19B CONTROL-HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION o
EXISTS IN DUCT WORK OF <0.10"H,0 AS SENSED BY AH-547-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
)
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 i
4 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.
IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED,
REFERENCES:
DRAWING 208-005 SHEET AH-086. DRAWING 308847 SENSING ELEMENT:
AH-547-DPS AR-401 Rev. 17 Page 24
ENCLOSURE 1 (Page 23 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 CNTRL C MPLEX O
AIR FLOW LOW EVENT POINT 1547 INDICATED CONDITION:
AHF-20B CON 1ROL HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION o
EXISTS IN DUCT WORK OF <0.08"H,0 AS SENSED BY AH-548-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o
o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP Gk A FIRE DAMPER ACTUATI0li.
IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.
THIS IS AN EXPECTED ALARM WHEN AHF-20B IS BEING RUN IN SLOW SPEED.
REFERENCES:
DRAWING 208-005 SHEET AH-089, DRAWING 308847
)
SENSING ELEMENT: AH-548-DPS AR-401 Rev. 17 Page 25
ERCLOSURE 1 (Page 24 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-03 F-01-03 1
El AH FLTR 4A/B PRESS HIGH I __
I EVENT POINT 0476 INDICATED CONDITION:
A HIGH DIFFERENTIAL PRESSURE EXISTS ACROSS AHFL-4A 0F >5.20"H,0 AS o
SENSED BY AH-205-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o DIFFERENTIAL PRESSURE INDICATOR AH-205-DPIl ON REAR OF MCB o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION, IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRE(.T THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED,
REFERENCES:
DRAWING 208-005 SHEET AH-131 DRAWING 308847 i
SENSING ELEMENT: AH-205-DPS I
L
.AR-401 Rev. 17 Page 26
ENCLOSURE 1 (Page 25 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-03 F-01-03 AH FLTR 4A/B PRESS HIGH EVENT POINT 0477 INDICATED CONDITION:
A HIGH DIFFERENTIAL PRESSURE EXISTS ACROSS AHFL-48 0F >5.20"H,0 AS o
SENSED BY AH-206-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o DIFFERENTIAL PRESSURE INDICATOR AH-206-DPIl ON REAP OF MCB o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:
THIS CONDITION MAY DE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.
IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.
REFERENCES:
DRAWING 208-005 SHEET AH-131, DRAWING 308847 SENSING ELEMENT: AH-206-DPS l
AR-401 Rev. 17 Page 27
l ENCLOSURE 1 (Page 26 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 i
CNTRL COMPLEX 1
DUCT TEMP t
HIGH 4
EVENT POINT 0469 e
4 INDICATED CONDITION:
4 HIGH TEMPERATURE OF >135T EXISTS IN THE CONTROL COMPLEX SUPPLY DUCT AS o
j SENSED BY AH-207-TS, i
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS
)
0 FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE HIGH TEMPERATURE ALARM o REFER TO OP-409-o REFER TO AP-880 d
a DISCUSSION:
Tiil5 CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.
IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM,
REFERENCES:
DRAWING 208-005 SHEET AH-080, DRAWING 308847 SENSING ELEMENT: AH-207-TS AR-401 Rev 17 Page 28
ENCLOSURE 1 (Page 27 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 i
CNTRL COMPLEX l
DUCT TEMP HIGH i
L.
l l
EVENT POINT 0487 INDICATED CONDITION:
HIGH TEMPERATURE OF >135T EXISTS IN THE DISCHA;,Lc 0F AHF-20A DUCT AS o
^
SENSED BY AH-258-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE HIGH TEMPERATURE ALARM o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.' IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.
REFERENCES:
DRAWING 208-005 SilEET AH-088, DRAWING 308847 SENSING ELEMENT: AH-258-TS AR-401 Rev. 17 Page 29
1 ENCLOSURE 1 (Page 28 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 i
j CNTRL COMPLEX DUCT TEMP j
HIGH i
t EVENT POINT 0517 INDICATED CONDITION:
HIGH TEMPERATURE EXISTS OF >135*F IN THE DISCHARGE OF AHF-20B DUCT AS o
SENSED BY AH-543-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE HIGH TEMPERATURE ALARM i
o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.
50 A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-089, DRAWING 308847 SENSING ELEMENT: AH-543-TS AR-401 Rev. 17 Page 30
3
{
ENCLOSURE 1 l
(Page 29 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 CNTRL COMPLEX DUCT TEMP HIGH EVENT POINT 0493 I
INDICATED CONDITION:
4 HIGH TEMPERATURE OF >135'F EXISTS IN THE CONTROL COMPLEX RETURN DUCT ON o
ELEVATION 124' AS SENSED BY AH-191-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o POSSIBLE LOW AIR FLOW AL/45 FIRE DAMPERS FD-28, AND Fu-29 ACTUATE o
OPERATOR ACTIONS FOR A VALID Al. ARM:
INVESTIGATE HIGH TEMPERATURE ALARM o
o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:
THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-101, DRAWING 308847 SENSING ELEMENT: AH-191-TS AR-401 Rev. 17 Page 31
.)
ENCLOSURE 1 O.
(Page 30 of 185)
PSA ANNUNC7ATOR RESPONSE PSA-X-01-05 F-01-05
. = ~. - -
=g 1,
L34 CNTRL COMPLEX
-.j H INST AIR PRESS Low t
l EVENT POINT 1690 INDICATED CONDITION:
AIR PRESSURE IN THE RECEIVER OF AHP-1A/1B AS SENSED BY AH-507-P5 IS o
<55 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL PRESSURE INDICATOR AH-896C-PI ON JOHNSON CONTROL PANEL 25A o
OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE THAT AHP-1A/1B ARE RUNNING VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o
DEENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o DISCUSSION:
Tiils CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM 'A" COMPONENTS AND A LOSS OF "A" SYSTEM AIR TO "AB" SYSTEM COMPONENTS.
REFERENCES:
DRAWING 208-005 SHEET AH-148-SENSINGEbEMENT: AH-507-PS AR-401 Rev. 17 Page 32
i l
ENCLOSURE 1 (Page 31 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 CNTRL COMPLEX INST AIR PRESS LOW EVENT POINT-1691 INDICATED CONDITION:
AIR PRESSURE IN THE RECEIVER OF AHP-1C/1D AS SENSED BY AH-509-PS IS <55 o
PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL PRESSURE INDICATOR AH-894C-PI ON JOHNSON CONTROL PANEL 258 o
OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE THAT /.HP-1C/1D ARE RUNNING VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o
DEENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o DISCUSSION:
THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM "B" COMPONENTS AND A LOSS OF "B" SYSTEM AIR TO "AB" SYSTEM COMPONEt:TS,
REFERENCES:
DRAWING 208-005 SHEET AH-149 i SENSING ELEMENT: AH-509-PS
.AR-401 Rev. 17 Page 33 l
l EBCLOSURE 1 (Page 32 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 l
CNTRL COMPLEX INST AIR PRESS LOW EVENT POINT 1692 INDICATED CONDITION:
REGULATED "A" SIDE CONTROL AIR AS SENSED BY AH-512-PS IS <17 PSIG o
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL PRESSURE INDICATOR AH-8968-PI ON JOHNSON CONTROL PANEL 25A o
OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE THAT AHP-1A/1B ARE RUNNING VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o
DEENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o DISCUSSION:
THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM "A" COMPONENTS AND A LOSS OF "A" SYSTEM AIR TO "AB" SYSTEM COMPONENTS.
REFERENCES:
DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-512-PS AR-401 Rev. 17 Page 34
~ _. -.
ENCLOSURE 1 (Page 33 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 CNTRL COMPLEX INST AIR PRESS LOW i
EVENT POINT 1693 INDICATED CONDITION:
AIR PRESSURE FOR DAMPER CONTROL AS SENSED BY AH-513-PS IS <I7 PSIG o
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL PRESSURE INDICATOR AH-895B-PI ON JOHNSON CON"0L PANEL 25AB o
OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE THAT AHP-1A/1B ARE RUNNING VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o
DEENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o DISCUSSION:.
THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VCNTILATION SYSTEM COMPONENTS
REFERENCES:
DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-513-PS AR-401 Rev. 17 Page 35
EELOSURE 1 (Page 34 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05
)
CNTRL COMPLEX INST AIR PRESS LOW I
EVENT POINT 1694 INDICATED CONDITION:
o REGULATED "B" SIDE CONTROL AIR AS SENSED BY AH-514-PS IS <17 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
4 LOCAL PRESSURE INDICATOR AH-8948-PI ON.10HNSON CONTROL PANEL 25B o
OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE THAT AHP-1C/10 ARE RUNNING VERIFY SAV-406 AND SAV-405 (CC STATION AIR SU!'oLY VALVES) OPEN o
DEENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o o ENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE)
DISCUSSION:
THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM "B" COMPONENTS AND A LOSS OF "B" SYSTEM AIR TO "AB" SYSTEM COMPONENTS.
REFERENCES:
DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-514-PS AR-401 Rev. 17 Page 36
ENCLOSURE 1 l
(Page 35 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-06 F-01-06 l
CNTRL COMPLEX AIR DRYER TEMP HIGH EVENT POINT 1695 INDICATED CONDITION:
AIR TEMPERATURE ON THE OUTLET OF AHDR-1A IS >45T AS SENSED BY o
AH-510-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
NOTIFY MECH SUPERVISOR IN CHARGE OF HVAC TO INSPECT AHDR-1A FOR PROPER o
OPERATION DISCUSSION:
AHDR-1A IS REFRIGERATED AIR DRYER WHICH UTILIZES A REFRIGERANT CYCLE To DRY CONTROL COMPLEX CONTROL AIR SUPPLY. HIGH AIR TCMPS CAN BE CAUSED BY Lt.'
REFRIGERANT CHARGE OR A DIRTY CONDENSER COIL,
REFERENCES:
DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-510-TS t
AR-401 Rev. 17 Page 37
i ENCLOSURE 1 (Page 36 of 185) i PSA ANNUNCIATOR RESPONSE PSA-X-01-06 F-01-06 CNTRL COMPLEX AIR DRYER TEMP HIGH EVENT POINT 1696 INDICATED CONDITION:
AIR TEMPERATURE ON THE OUTLET OF AHDR-1B IS >45T AS SENSED BY AH-511-TS o
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALIO ALARM:
NOTIFY MECH SUPERVISOR IN CHARGE OF HVAC TO INSPECT AHDR-1B FOR PROPER o
OPERATION DISCUSSION:
AHDR-1B IS REFRIGERATED AIR DRYER WHICH UTILIZES A REFRIGERANT CYCLE TO DRY CONTROL COMPLEX CONTROL AIR SUPPLY. HIGH AIR TEMPS CAN BE CAUSED BY LOW REFRIGERANT CHARGE OR A DIRTY CONDENSER COIL.
REFERENCES:
DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-511-TS AR-401 Rev. 17 Page 38
_ - - _ - -.. -..- -. - - -. -.~ - --
ENCLOSURE 1 (Page 37 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 0518 INDICATED CONDITION:
CHP-1A MOTOR IS NOT-ENERGIZED WITH THE CONTROL HANDLE IN THE NORMAL o
AFTER START POSITION REDUNDANT INDICATION WHICH WILL' VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON THE CHP-1A CONTROL STATION o RUNNING CHILLER TRIPS ON LOW CHILLED WATER FLOW OPERATOR ACTIONS FOR A VALID ALARM:
o START CHP-1B AND CHHE-1B PER OP-409 DISCUSSION:
REFERENCES:
DRAWING 208-076 SHEET CH-03 SENSING ELEMENT:
42/5CR AR-401
.Rev. 17 Page 39
l ENCLOSURE 1 (Page 38 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 0519 l
INDICATED CONDITION:
o-CHP-1B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT ON WITH A RED FLAG ON THE CHP-1B CONTROL STATION o
o RUNNING CHILLER TRIPPED ON LOW CHILLED WATER FLOW OPERATOR ACTIONS FOR A VALID ALARM:
o START CHP-1A AND CHHE-1A PER OP-409 l
DISCUSSION:
REFERENCES:
DRAWING 208-076 SHEET CH-04
/~T
.'g SENSING ELEMENT: CS/SC CS/0, 428 RELAY l
L AR-401 Rev. 17 Page 40
4 ENCLOSURE 1 t
(Page 39 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 I
1:
CHILLED WATER SYSTEM TROUBLE 4
i EVENT POINT 0520 1
INDICATED CONDITION:
CHHE-1A BREAKER IS OPEN WITH CONTROL HANDLE IN THE NORHAL AFTER-START
-o POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON CHHE-1A CONTROL STATION i
i OPERATOR ACTIONS FOR A VALID ALARM:
HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS o
o SWAP CHILLERS PER OP-409 DISCUSSION:
AN ES BUS UNDERVOLTAGE CONDITION WILL CAUSE THIS CONDITION, THE BREAKER WILL NOT BE ABLE.TO BE RECLOSED UNTIL THE UNDERVOLTAGE LOCK OUT HAS BEEN
- RESET,
REFERENCES:
DRAWING 208-076 SHEET CH-01 SENSING ELEMENT: CS/SC, CS/0, R/B CONTACT AR-401 Rev. 17 Page 41
.-.____.-..-_m_
ENCLOSURE 1 (Page 40 of 189 PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 0521 INDICATED CONDITION:
o CHHE-1B BREAKER IS OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN LIGHT ON WITH A RED FLAG ON CHHE-1B CONTROL STATION o
OPERATOR ACTIONS FOR A VALID ALARM:
HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS o
o SWAP CHILLERS PER OP-409 DISCUSSION:
AN'ES BUS UNDERVOLTAGE CONDITION WILL CAUSE THIS CONDITION, THE BREAKER WILL NOT BE ABLE TO BE RECLOSED UNTIL THE UNDERVOLTAGE LOCK OUT HAS BEEN RESET.
REFERENCES:
DRAWING 208-076 SHEET CH-02 SENSING ELEMENT:
CS/SC, CS/0, R/B CONTACT AR-401 Rev. 17 Page 42
ENCLOSURE 1 (Page 41 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 1526 INDICATED CONDITION:
l o CHT-1 LEVEL 15 h 180' 2",
OR z 12" BELOW CENTER LINE OF TANK REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL LEVEL INDICATOR ON CHT-1 OPERATOR ACTIONS FOR A VALID ALARM:
CONTACT CHEMISTRY AND REFILL CHT-1 REFER TO re-409 o
DISCUSSION:
REFERENCES:
DRAWING 208-076 SHEET CH-06 SENSING ELEMENT: CH-660-LSS AR-401 Rev. 17 Page 43
ENCLOSURE 1 (Page 42 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 r
CHILLED WATER SYSTEM TROUBLE
-EVENT POINT 1554 i
INDICATED CONDITION:
}
o CHHE-1A BREAKER HAS NO DC CONTROL POWER REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
. t l
o NO INDICATING LIGHTS ON CHHE-1A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
1 VERIFY " PULL OUT" FUSE BLOCK FOR CHHE-1A BREAKER IS INSTALLED o
o VERIFY DPDP-5A BREAKER 9 CLOSED J
DISCUSSION:
THIS CONDITION DISABLES REMOTE BREAKER OPERATION AND PROTECTIVE RELAYING.
REFER TO OP-703 FOR INSTRUCTIONS ON LOCAL BREAKER OPERATION.
THIS IS AN EXPECTED ALARM FOR BREAKER TAGGING OPERATIONS.
1
REFERENCES:
DRAWING 208-076 SHEET CH-01 SENSING ELEMENT:
27C RELAY 4
AR-401 Rev. 17 Page 44
ENCLOSURE 1 (Pago 43 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-03-07 CHILLED WATER SYSTEM TROUBLE l
EVENT POINT 1555 INDICATED CONDITION:
o CHHE-1B BREAKER HAS NO DC CONTROL POWER REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o NO INDICATING LIGHTS ON CHHE-1B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
VERIFY PULL OUT FUSE BLOCK FOR CHHE-1B BREAKER IS INSTALLED o
o VERIFY DPDP-5B BREAKER 9 CLOSED DISCUSSION:
THIS CONDITION DISABLES REMOTE BREAKER OPERATION AND PROTECTIVE RELAYING.
REFER TO OP-703 FOR INSTRUCTIONS ON LOCAL BREAKER OPERATION.
THIS IS AN EXPECTED ALARM FOR BREAKER TAGGING OPERATIONS.
REFERENCES:
DRAWING 208-076' SHEET CH-02 SENSING ELEMENT: 27C RELAY AR-401 Rev. 17 Page 45
a-wA ENCLOSURE 1 (Page 44 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 1556 INDICATED CONDITION:
CHHE-1A MOTOR WINDING TEMPERATURE IS >105"C, OR CHHE-1A OIL o
TEMPERATURE IS >170*F.
P".DUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR "0IL/ MOTOR o
TEMPERATURE" OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN
-UNTIL THE RESET PUSHBUTTON IS DEPRESSED
REFERENCES:
DRAWING 208-076 SHEET CH-05
-(
SENSING ELEMEP(T:
6R, 2/A AR-401 Rev. 17 Page 46
ENCLOSURE 1 (Page 45 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 1557 INDICATED CONDITION:
l o CHHE-1A REFRIGERANT PRESSURE IS < 11.9" HG l
t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR " LOW PRESSURE" o
OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 i
DISCUSSION:
THIS' CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON Id DEPRESSED
REFERENCES:
DRAWING 208-076 SHEET CH-05 SENSING ELEMENT:
7R, 2/A AR-401 Rev. 17 Page 47
ERCL01URE_1 (Page 46 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01 ;
CHILLED WATER SYSTEM TROUBLE EVENT POINT 1558 INDICATED CONDITION:
l o CHHE-1A REFRIGERANT PRESSURE IS >15 PSIG i
REDUNDANT-INDICATION WHICH WILL VERIFY ALARM:
o LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR "HIGH PRESSURE" OPERATOR ACTIONS FOR A VALID ALARM:
l o SWAP CHILLERS PER OP-409 d
1 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON-IS DEPRESSED 4
REFERENCES:
DRAWING 208-076 SHEET CH-05 SENSING ELEMENT:
8R, 2/A AR-401 Rev. 17 Page 48
f~
ENCLOSURE 1 (Page 47 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 4
i CHILLED WATER SYSTEM TROUBLE 4
i EVENT POINT 1559 INDICATED CONDITION:
o CHHE-1A OIL PRESSURE IS < 27 PSIG 1
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR " LOW OIL PRESS" o
OPERATOR ACTIONS FOR A VALID ALARM:
4 o SWAP CHILLERS PER OP-409 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED REFEP,ENCES:
DRAWING 208-076 SHEET CH-05 SENSING ELEMENT:
9R, 2/A AR-401 Rev. 17 Page 49
ENCLOSURE 1 (Page 48 of 185)
J PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER I
SYSTEM TROUBLE EVENT POINT 1560 INDICATED CONDITION:
CHHE-1A DOES NOT HAVE ANY POWER TO THE CONTROL PANEL OR COMPRESSOR MOTOR o
AS SENSED '
~ LAY 14/R j
REDUNDANT In..
tTION WHICH WILL VERIFY ALARM:
AMBER " POWER FAILURE" LIGHT ON LOCAL CONTROL PANEL o
i.
OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF POWER LOSS 3
r DISCUSSION:
REFERENCES:
DRAWING 208-076 SHEET CH-05
{
SENSING ELEMENT:
14R, 2/A AR-401 Rev. 17 Page 50
p ENCLOSURE 1 (f.__
(Page 49 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 1561 INDICATED CONDITION:
CHHE-1B MOTOR WINDING TEMPERATURE IS >105aC, OR CHHE-1B OIL TEMPERATURE o
IS >170*F.
t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR "0IL/ MOTOR TEMP" o
OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED
REFERENCES:
DRAWING 208-076 SHEET CH-06
-t SENSING ELEMENTi 6R, 2/B AR-401 Rev. 17 Page 51
.-.~. - -. _ -. - -.. -.
- -. -. - - =.. -..
a J
ENCLOSURE 1 (Page 50 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 i
CHILLED WATER j
SYSTEM
)
TROUBLE 1..
EVENT POINT 1562 INDICATED CONDITION:
l o CHHE-1B REFRIGERANT PRESSURE IS <1I.9" HG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR " LOW PRESSURE" OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED
REFERENCES:
DRAWING 208-076 SHEET CH-06 SENSING ELEMENT:
7R, 2/B AR-401 Rev. 17 Page 52
ENCLOSURE 1 (Page 51 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 i
CHILLED WATER SYSTEM TROUBLE 4
EVENT POINT 1563 i
INDICATED CONDITION:
a.
{
l o CHHE-1B REFRIGERANT PRESSURE IS >15 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR "HIGH PRESSURE" o
OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 1
DISCUSSION:
1 THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED
REFERENCES:
DRAWING 208-076 SHEET CH-06 O
lig SENSING-ELEMENT:
8R, 2/B l
AR-401-Revi 17 Page 53
... - ~..
-- - _. -. ~
d ENCLOSURE 1
~ [m (Page 52 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01 F-01-07 CHILLED WATER SYSTEM TROUBLE l
EVENT POINT 1564 INDICATED CONDITION:
o CHHE-1B OIL PRESSURE IS < 27 PSIG l
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL CONTROL PANEL - RED INDICATOR LIGHT IS ON FOR " LOW OIL PRESS" o
OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP CHILLERS PER OP-409 DISCUSSION:
THIS CONDITION WILL CAUSE THE CHILLER TO' TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTf3N IS DEPRESSED 3
REFERENCES:
DRAWING 208-076 SHEET CH-06
(
SENSING ELEMENT:
9R, 2/B 2
AR-401 Rev. 17 Page 54 l
ENCLOSURE 1 (Page 53 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 J
i CHILLED WATER SYSTEM TROUBLE EVENT POINT 1565 1
INDICATED CONDITION:
CHHE-1B DOES NOT HAVE ANY POWER TO THE CONTROL PANEL OR COMPRESSOR MOTOR o
AS SENSED BY RELAY 14/R REDUNDANT, INDICATION WHICH WILL VERIFY ALARM:
o AMBER " POWER FAILURE" LIGHT ON LOCAL CONTROL PANEL 1
OPERATOR ACTIONS FOR A VALID ALAPM:
o INVESTIGATE THE CAUSE OF POWER LOSS 1
DISCUSSION:
(
REFERENCES:
DRAWING 208-076 SHEET CH-06 j
SENSING ELEMENT:
14R, 2/B AR-401 Rev. 17 Page 55
4 i
ENCLOSURE 1 (Page 54 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-01 F-02-01 1
I I
TOXIC GAS l
I MONITOR I
I TROUBLE I
I l
l I
I EVENT POINT 0314 i
1 l
l 1-INDICATED CONDITION:
o 'ONE OR MORE OF THE FOLLOWING MONITORS' LOCAL TROUBLE ALARMS HAS ACTUATED:
AH-648-CE AH-652-CE AH-649-CE AH-653-CE l
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOCAL TROUBLE ALARMS ON AH-648-CE, AH-649-CE AH-652-CE, OR AH-653-CE o
COMPUTER POINTS S263, S297, 5298, 5299 FOR T0XIC GAS CONCENTRATION o
4 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTICATE THE CAUSE OF TROUBLE o-NOTIFY I&C TO TROUBLE SHOOT MONITORS i
DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-84
- q Q
SENSING ELEMENT: AH-648-CE, AH-652-CE, AH-649-CE, AH-653-CE AR-401 Rev. 17 Page 56
ENCLOSURE 1 (Page 55 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-01 F-02-01 I
I TOXIC GAS I-I MONITOR
-l-l TROUBLE I
I I
I EVENT POINT 0432 INDICATED CONDITION:
T0XIC GAS >5 PPM CL AS SENSED BY AH-648-CE AND/OR AH-649-CE OR, o
>2 PPM SO, SENSED BY AH-652-CE AND/OR AH-653-CE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o COMPUTER POINTS 5263, 5297, 5298, OR 5299 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO AP-513 o REFER TO SP-300 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-84 SENSING ELEMENT: AH-648-CE, AH-652-CE, AH-649-CE, AH-653-CE AR-401 Rev. 17 Page 57
1 ENCLOSURE 1 (Page 56 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-01 F-02-01 I
I TOXIC GAS I
I MONITOR I
I TROUBLE I
I I
I I
I EVENT POINT 0800 INDICATED CONDITION:
T0XIC GAS >20 PPM S0, SENSED DETECTORS AT UNITS 1&2 o
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o NOTIFICATION OF A SPILL FROM UNITS 1&2 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO AP-513 DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-84A SENSING ELEMENT:
UNITS 1 & 2 "A" OR "B" 502 DETECTOR AR-401 Rev. 17-Page 58
ENCLOSURE 1 (Page 57 of 385)
PSA ANNUNCIATOR RESPONSE PSA-X-02-04 F-02-04
-l i
ClSYSTEM TROUBLE EVENT POINT 1567 1NDICATED CONDITION:
THE 4160V BREAKER FOR THE REACTOR BLDG. CHILLER IS CLOSED AND AN ALARM o
EXISTS ON THE MICROTECH CONTROL PANEL LOW DIFFERENTIAL PRESSURE ACROSS CIP-1A OR CIP-1B o
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
A FAULT IS INDICATED ON THE MICROTECH FLUORESCENT DISPLAY o
o CIP-1A OR CIP-1B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:
o-DEPRESS THE " UNIT STATUS" PUSNBUTTON IF NO VISUAL DISPLAY PRESENT DEPRESS THE " FAULT HISTORY" PUSHBUTTON ONCE TO DETERMINE THE CURRENT o
FAULT, AND EIGHT MORE TIMES FOR THE PREVIOUS EIGHT FAULTS IF DESIRED CORRECT SOURCE OF THE FAULT, THEN DEPRESS " CLEAR FAULT" PUSHBUTTON AND o
RESTART THE CHILLER IF DESIRED, REFER TO OP-417A IF THE CHILLER CANNOT BE RESTARTED, THEN PLACE THE SYSTEM IN THE " FREE" o
COOLING MODE OR SWAP TO SW COOLING FOR THE RB COOLING UNITS, REFER TO OP-417A PLACE ALTERNATE CIP IN SERVICE PER OP-417A o
DISCUSSION:
HIGH DISCHARGE PRESSURE, WHICH IS HIGH CONDENSOR PRESSURE, TRIPS THE o
HIGH MECHANICAL PRESSURE SWITCH. FIRST THE SWITCH MUST BE RESET INSIDE MICROTECH, THEN CLEAR FAULT WILL ALLOW RESTART.1F THE FAULT CANNOT BE CLEARED, THEN HVAC PERSONNEL SHOULD BE NOTIFIED FOR RESOLUTION IF THE CHILLER IS OPERATING WHEN A CIP TRIPS, THEN THIS WILL TRIP THE o
CHILLER ON LOW FLOW
(
/(/
REFERENCES:
DRAWING 208-077 SHEET CI-25 SEi4 SING ELEMENT: RL3-ALM, RL6-ALM, CI-772-DPS AR-401 Rev. 17 Page 59
- _ =
~
~..~. - -.
4 ENCLOSURE 1
()
(Page 58 cf 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-04 F-02-04 ClSYSTEM TROUBLE i
EVENT POINT 1568 INDICATED CONDITION:
o HIGH VIBRATION ON CIF-1A OR CIF-1B o LOW TOWER BASIN WATER LEVEL 1
[t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CIF-1A OR CIF-1B HAS TRIPPED CIP-1A OR CIP-1B MAY TRIP ON LOW DP, MAY EXHIBIT CAVITATION, OR MAY o
CAUSE A TRIP OF THE RB CHILLER ON LOW FLOW 4
OPERATOR ACTIONS FOR A VALID ALARM:
NOTIFY HVAC PERSONNEL FOR TRIPPED FAN ON HIGH VIBRATION o
VERIFY PROPER VALVE ALIGNMENT FOR LOW BASIN LEVEL o
~
SECURE PUMP IF CAVITATION EXISTS AND ESTABLISH SW COOLING TO THE RB o
UNTIL PROBLEM IS CORRECTED l
o ENSURE PROPER DO TANK LEVEL r
DISCUSSION:
THE BASIN WATER LEVEL IS AUTOMATICALLY MAINTAINED WITH TKO FLOAT VALVES o
OPERATING IN PARALLEL TO SUPPLY EACH TOWER, THE TOWER BASINS ARE l
CROSSTIED SUCH THAT EITHER VALVE WILL SUPPLY BOTH BASINS. LOW BASIN LEVEL DISABLES THE BASIN WATER HEATERS.
l DO SYSTEM SUPPLIES MAKEUP TO THE IB ROOF AND SOUTH BERM COOLING TOWER o
REFERENCES:
DRAWING 208-077 CI-29 AND CI-30 rm
- (_ )
SENSING ELEMENT:
CI-784-SS, CI-785-SS, CI-780-LS, CI-761-LS T
AR-401 Rev. 17 Page 60
.-.. -. _ -. -. ~._.. -
' 3 CLOSURE 1 (Page 59 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-05 F-02-05 4
l Cl CIRC PP 1A/B OVERLOAD -
EVENT POINT 1879 INDICATED CONDITION:
o CIP-1A OR CIP-1B MOTOR CURRENT.IS EXCESSIVE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o PUMP MAY TRIP FROM LOW DP AS A RESULT OF LOCKED ROTOR OR VERY HIGH FLOWRATES OPERATOR ACTIONS FOR A VALID ALARM:.
o INVESTIGATE OPERATION OF CIP-1A OR CIP-1B o SWAP RB COOLING TO SW IF REQUIRED DISCUSSION:
REFERENCES:
DRAWING 208-077 CI-27 AND CI-28 SENSING ELEMENT: OVERLOAD HEATERS IN INST COMPARTMENT IN UNIT 480V SG RM AR-401 Rev. 17 Page 61
_--. ~.. -...
1 ENCLOSURE 1 -
(Page 60 of-185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06 1-1 i
Cl CIRC PUMP 2A/B 3A/B TRIP EVENT POINT 0524 INDICATED CONDITION:
~
CIP-2A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START o
POSITION
(
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
GREEN-LIGHT ON WITH A RED FLAG ON CIP-2A CONTROL STATION o
OPERATOR ACTIONS FOR A VALID ALARM:
o START-CIP-2B o HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS DISCUSSION:
REFERENCES:
DRAWING 208-077 SHEET CI-03 SENSING ELEMENT: 'CS/SC, CS/0, R/B AR-401 Rev. 17 Page 62
~.
=.
I 4
ENCLOSURE 1 (Page 61 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06
)
I I
a Cl CIRC PUMP 2A/B 3A/B TRIP 4
i EVENT POINT 0526 i
INDICATED CONDITION:
CIP-2B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTD'. START o
POSITION 1
b REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
V GREEN LIGHT ON WITH A RED FLAG ON CIP-28 CONTROL STATION o
4 OPERATOR ACTIONS FOR A VALID ALARM:
I o ' START CIP-2A HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS o
DISCUSSION:
1 i
REFERENCES:
DRAWING 208-077 SHEET CI-04 SENSING ELEMENT: CS/SC, CS/0, R/B AR-401 Rev. 17 Page 63
ENCLOSURE 1 (Page 62 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06 i
~
Cl CIRC PUMP 2A/B 3A/B TRIP 1
EVENT POINT 0528 INDICATED CONDITION:
CIP-3A CONTROL HANDLE IN NORMAL AFTER START POSITION WITH THE MOTOR NOT o
ENERGIZED A
t.]
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON CIP-3A CONTROL STATION d
OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP REACTOR CAVITY COOLING TO "B" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 DISCUSSION:
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.
REFERENCES:
DRAWING 208-077 SHEET CI-18 A()
SENSING ELEMENT:42/13CR AR-401 Rev. 17 Page 64
ENCLOSURE 1 (Page 63 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06 l
l Cl CIRC PUMP 2A/B 3A/B TRIP EVENT POINT 0529 INDICATED CONDITION:
CIP-3B CONTROL HANDLE IN NORMAL AFTER START POSITION WITH THE MOTOR NOT o
ENERGIZED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
-a GREEN LIGHT ON WITH A RED FLAG ON CIP-3B CONTROL STATION o
OPERATOR ACTIONS FOR A val.ID ALARM:
SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o
MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409
.o DISCUSSION:
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF TLE NUCLEAR INSTRUMENTATION.
REFERENCES:
DRAWING 208-077 SHEET CI-19 SENSING ELEMENT: CS/SC, CS/0, 42B AR-401 Rev. 17 Page 65
ENCLOSURE 1 (Page 64 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-07 F-02-07 Cl CIRC PUMP 2A/B OVERLOAD EVENT POINT 0525 l
INDICATED CONDITION:
o CIP-2A MOTOR AMPS >115% RATED LOAD r5
-(y REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
HIGH LOCAL TEMPERATURES ON PUMP AND OR MOTOR o
OPERATOR ACTIONS FOR A VALID ALARM:
o SHUTDOWN CIP-2A AND STARi CIP-2B o -INVESTIGATE THE OPERATION OF THE PUMP MOTOR TO DETERMINE THE CAUSE OF THE ALARM DISCUSSION:
THIS ALARM INDICATES THAT THE INTERNAL OVERCURRENT DEVICE HAS ACTUATED AND THAT THE MOTOR MAY TRIP AT ANY TIME.
REFERENCES:
DRAWING 208-077 SHEET CI-03 SENSING ELEMENT:
49X THERMAL OVERLOADS IN MCC AR-401-Rev. 17 Page 66
fq, ENCLOSURE 1
)
(Page 65 of 185L PSA ANNUNCIATOR RESPONSE PSA-X-02-07 F-02-07 I
4 Cl CIRC PUMP 2A/B OVERLOAD EVENT POINT 0527 INDICATED CONDITION:
o CIP-28 MOTOR AMPS >115% RATED LOAD REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH LOCAL TEMPERATURES ON PUMP AND OR MOTOR OPERATOR ACTIONS FOR A VALID ALARM:
o SHUTDOWN CIP-28 AND ST/,RT CIP-2A INVESTIGATE THE OPERATION OF THE PUMP MOTOR TO DETERMINE THE CAUSE OF o
THE ALARM DISCUSSION:
THIS ALARM INDICATES THAT THE INTERNAL OVERCURRENT DEVICE HAS ACTUATED
.AND THAT THE MOTOR MAY TRIP AT ANY TIME.
REFERENCES:
DRAWING 208-077 SHEET CI-04 m
(
SENSING ELEMENT:
9X THERMAL OVERLOADS IN MCC AR-401 Rev. 17 Page 67
ENCLOSURE 1 (Page 66 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-02-08 F-02-08 Cl PUMP SUCT PRESS LOW l-EVENT POINT 1702 INDICATED CONDITION:
CIP-2A BREAKER IS CLOSED AND SUCTION PRESSURE IS < 5 PSIG AS SENSED BY o
CI-728-PS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
LOW LOCAL PRESSURES ON PUMP SUCTION GAUGE CI-99-PI o
OPERATOR ACTIONS FOR A VALID ALARM:
o CHECK CIT-1 LEVEL INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE o
VERIFY PROPER OPERATION OF Tile REACTOR BLDG CHILLER o
DISCUSSION:
THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK, OR BY EXCESSIVE PRESSURE DROP ACROSS CIHE-3/CIHE-4A OR THE LEAK RATE TEST COOLER. THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.
REFERENCES:
DRAWING 208-077 SHEET CI-03
(
l SENSING ELEMENT: CI-728-PS, R/A AR-401 Rev. 17 Page 68
m-_______
't a
ENCLOSURE 1 (Page 67 of 185) 1 PSA ANNUNCIATOR RESPONSE PSA-X-02-08 F-02-08 i
I I
3 I
Cl PUMP I
SUCT PRESS I
LOW i
I
~
j--
EVENT POINT 1703 INDICATED CONDITION:
CIP-28 EREAKER IS CLOSED AND SUCTION PRESSURE IS < 5 PSIG AS SENSED BY o
4 CI-729-PS i
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
j o LOW LOCAL PRESSURES ON PUMP SUCTION CAUCE CI-lol-P1 1
j-OPERATOR ACTIONS FOR A VALIO ALARM:
o CHECK CIT-1 LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE o VERIFY PROPER OPERATION OF THE REACTOR BLOG CHILLER i
)
DISCUSSION:
THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK. OR BY EXCESSIVE PRESSURE DROP ACROSS CIHE-3/CIHE-4A OR THE LEAK RATE TEST COOLER.- THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.
REFERENCESt DRAWING 208-077 SHEET CI-04 SENSING ELEMENT:
CI-729-PS, R/A AR-401 Rev. 17 Page 69
ENCLOSELI (Page 68 of 185) i PSA ANNUNCIATOR RESPONSE PSA-X-02-08 l F-02-08 l
I I
l l
1 l
l Cl PUMP I
I SUCT PRESS I
I LOW I
I 1
EVENT POINT 1704 I
INDICATED CONDITION:
+
1 o
CIP-3A CONTROL SWITCH IS IN NORMAL AFTER START, AND SUCTION PRESSURE IS
< 45 PSIG AS SENSED BY CI-730-PS t
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o. LOW LOCAL PRESSURES ON PUMP SUCTION GAUGE CI-732-PI 4
OPERATOR ACTIONS FOR A VALID ALARM:
o CHECK CIT-1 LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 o
l o CHECK CIP-2A/2B DISCHARGE PRESSURE DISCUSSION:
THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK, OR BY EXCESSIVE FLOWRATE. THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.
A SUSTAINED LOSS OF C00LIflG TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION,
REFERENCES:
DRAWING 208-077 SHEET CI-18 J
SENSING ELEMENT: CI-730-PS
)
AR-401 Rev. 17 Page 70
I i
ENCLOSUREJ (Page 69 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X 02-08 F-02-08 i
f l
I I
I I
I Cl PUMP I
I SUCT PRESS I
I LOW l
I I
i l
EVENT POINT 1705 i
)
INDICATED CONDITION:
=
CIP-38 CONTROL SWITCH IS IN NORMAL AFTER START, AND SUCTION PRESSURE IS 3
o
< 45 PSIG AS SENSED BY CI-731-PS i
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
f o LOW LOCAL PRESSURES ON PUMP SUCTION GAUGE CI-733-PI 1
OPERATOR ACTIONS FOR A VALID ALARM:
o CHECK CIT-1 LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 o
l o CHECK CIP-2A/2B DISCHARGE PRESSURE DISCUSSION:
THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK, OR BY EXCESSIVE FLOWRATE. THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.
A SUSTAINED LOSS GF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.
O,
REFERENCES:
DRAWING 208-077 SHEET CI-19 SENSING ELEMENT:
CI-731-PS AR-401 Rev. 17 Page 71
j ENCLOSURE 1 (Page 70 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01
^
l l
I I
TURBINE BLDG l
l FIRE ALERT I
I I
I EVENT POINT 0443 INDICATED CONDITION:
TEMPERATURE > 135'F AS SENSED BY AH-125-TS EXISTS IN THE INTAKE PLENUM o
FOR AHF-16A/16B REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-16A TRIPS o AHF-16B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE AHF-16A/AHF-168 ARE SHUT DOWN o REFER TO THE CR3 PRE FIRE-PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE INTAKE DUCT OF AHF-16A/AHF-168.
REFERENCES:
DRAWING 208-005 SHEETS AH-058, DRAWING 308846 SENSING ELEMENT: AH-125-TS AR-401 Rev. 17 Page 72 y
,.w..
.---r
m-
-er.-
'~
w mr' ev -'-'
'*-v
~
v-
=
y e-w-+---
r
ENCLOSURE 1 (Page 71 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 I
I l
I TUR81NE BLDO I
I I
FIRE ALERT i
l i
l l
+
I i
EVENT POINT 0444 I
INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-126-CE TROUBLE nAS BEEN DETECTED IN THE CIRCUITS FOR AH-126-CE o
i o
TEMPERATURE > 135T AS SENSED BY AH-126-TS EXISTS IN THE RETURN AIR DUCT FROM 119' SWITCH GEAR ROOM O
J J
j REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
a THIS ALARM WILL RESULT IN THE ACTUATION OF THE FOLLOWING FIRE DAMPERS o
FD-38, FD-40, FD-48, FD-49, AND FD-50 a
OPERATOR ACTIONS FOR A VALID ALARM:
1 o ENSURE AHF-16A/AHF-16B ARE SHUT DOWN o CEFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 i
DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE RETURN AIR DUCT FROM 119' SWITCH CEAR ROOM TO AHF-16A/AHF-168.
1
REFERENCES:
DRAWING 208-005 SHEETS AH-058, AH-060, AND DRAWING 308846 SENSING ELEMENT: AH-126-TS, AH-126-CE, 3AH-126-TS/RR-HV-V AR-401 Rev. 17 Page 73
ENCLOSURE 1 O
(Page 72 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 l
l I
I
- !UR81NE SLDG l
l FIRE ALERT l
l I
I l
EVENT POINT 0448 INDICATED CONDITION:
PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-127-CE o
TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-127-CE o
TEMPERATURE > 135'F AS SENSED BY AH-127-TS EXISTS IN THE RETURN AIR DUCT o
FROM 95' SWITCH GEAR ROOM O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
THIS ALARM WILL RESULT IN THE ACTUATION OF THE FOLLOWING FIRE DAMPERS o
FD-39 AND FD-41 OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE AHF-16A/AHF-16B ARE SHUT DOWN o REFER TO THE PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE RETURN AIR DUCT FROM 95' SWITCH CEAR ROOM TO AHF-16A/AHF-168.
REFERENCES:
DRAWING 208-005 SHEETS AH-059, AH-060, AND DRAWING 308846 O
SENSING ELEMENT:
AH-127-TS, AH-127-CE, 3AH-127-TS/RR-HV-V AR-401 Rev. 17 Page 74
i
{
ENCLOSURE 1 (Page 73 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 4
l 4
I I
I I
TURBlNE BLDG l
l FIRE ALERT I
I l
l EVENT POINT 0449 INDICATED CONDITION:
ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135T o
AH-153-TS AH-523-TS AH-524-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
0 FIRE DAMPERS FD-52 FD-53, AND FD-54 TRIP o AHF-25A, AHF-258, AND AHF-25C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:
NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THESE TURBINE BUILDING o
SUPPLY FANS o REFER TO AP-880 i
t DISCUSSION:
f
.THIS ALARM INDICATES THAT THE FIRE DAMPERS FOR AHF-25A/B/C HAVE ACTUATED, AHF-25A/B/C SHOULD SHUTDOWN AUTOMATICALLY.
i
REFERENCES:
DRAWING 208-005 SHEET AH-061, AH-70, DRAWING 308846 SENSING ELEMENT: AH-153-TS, AH-523-TS, AH-524-TS, AND RELAY 3HBT1A 7
AR-401-Rev. 17 Page 75 I
i
--w---
-.-c.,%,y---,v e.--e
<c--
c, e
,,2
-.- ~, - - - -
.e.-.
-,1-.-+..~,.w..m- -..,.., _., - -
ENCLOSURE 1 (Page 74 of 185)
{
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 i
I I
I I
TURBINE BLDG I
I FIRE ALERT l
l I
I I
I EVENT POINT 0450 INDICATED CONDITION:
ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135T o
AH-155-TS AH-527-TS AH-528-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-26A, AHF-26B, AND AHF-26C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:
NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THESE TURBINE BUILDING o
SUPPLY FANS o REFER TO AP-880 l'
l DISCUSSION:
l l
THIS ALARM INDICATES THAT THE FIRE DAMPERS FOR AHF-26A/8/C HAVE ACTUATED, AHF-26A/B/C SHOULD SHUTDOWN AUTOMATICALLY.
REFERENCES:
DRAWING 208-005 SHEET AH-064, AH-70. DRAWING 308846 SENSING ELEMENT: AH-155-TS, AH-527-TS, AH-528-TS, AND RELAY 3HBT2 AR-401 Rev. 17 Page 76
_, - - _ J
fSCLOSML.1 (Page 75 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 l
l I
I TURBINE BLDG l
l FIRE ALERT I
l I
I EVENT POINT 0451 INDICATED CONDITION:
ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135T o
AH-154-TS AH-525-TS AH-526-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM o AHF-27A, AHF-278, AND AHF-27C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:
NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THESE TURBINE BUILDING o
SUPPLY FANS o REFER TO AP-880 DISCUSSION:
THIS ALARM. INDICATES THAT THE FIRE DAMPERS FOR AHF-27A/B/C HAVE ACTUATED, AHF-27A/8/C SHOULD SHUTDOWN AUTOMATICALLY.
REFERENCES:
DRAWING 208-005 SHEET AH-067 AH-70, DRAWING 308846 SENSING ELEMENT: AH-154-TS, AH-525-TS, AH-526-TS, AND RELAY 3HBT3 AR-401 Rev. 17 Page 77
i Lt(CLQSURE 1 (Page 76 of 185) i PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 l
l l
1-I TURBINE BLDG FIRE ALERT I
I 1
I EVENT POINT 1118 INDICATED CONDITION:
PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-723-CE o
TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-723-CE o
O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
DETECTION OF PRODUCTS OF COMBUSTION WILL TRIP AHF-49 IF RUNNING o
OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE INSTRUMENT CAL LAB 145' TURBINE DECK,
REFERENCES:
DRAWING 208-005 SHEETS AH-151 AND AH-152 O
v SENSING ELEMENT: AH-723-CE AR-401 Rev. 17 Page 78
i ENCLOSMB.E_J (Page 77 of 185)
I PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 t
I AUXBLDG FIRE ALERT EVENT POINT 0006 INDICATED CONDITION:
PENETRATION COOLING DUCT TEMPERATURE UPSTREAM OF FD-278 IS >I65T AS o
SENSED BY AH-1004-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o PENETRATION COOLING FANS AHF-9A/98 TRIP ON INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE AHF-9A/98 ARE SHUTDOWN o INVESTIGATE CAUSE OF ALARM DISCUSSION:
THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DUCT WORK.
CONSIDERATION SHOULD BE GIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS. AH-1004-TS IS A MANUAL RESET TEMPERATURE SWITCH LOCATED AT INT. BLOG. 95' ELEV. NEXT T0-THE LOCAL CONTROL STATION FOR AHF-9A AND 9B.
REFERENCES:
DRAWING 208-005 SHEET AH-056, DRAWING 308849 SENSING ELEMENT: AH-1004-TS 1
AR-401 Rev. 17 Page 79
. _ _ _. ~ - _ _ _ _ _ _ _ _.
i ENCLOSURE 1
()
(Page 78 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02
~
AUX BLDG FIRE ALERT
'l EVENT POINT 0380 4
INDICATED CONDITION:
o RB PURGE SUPPLY DUCT TEMP IS >135*F AS SENSt. BY AH-23-TS, OR PRODUCTS OF COMBUSTION HAVE BEEN SENSED BY AH-23-CE AND/OR AH-24-CE, OR RELAY 3PSFP HAS ACTUATED
(
o RB PURCE SUPPLY DUCT TEMP IS <701: AS SENSED BY AH-645-TS
- V)
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o PURGE SUPPLY FANS AHF-6A/6B TRIP o PURGE SUPPLY DAMPER AHV-1D CLOSES ON LOW PURGE SUPPLY FLOW OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTICATE THE CAUSE OF THE ALARM o SECURE RB PURGE PER OP-417. IF HIGH TEMP ALARM o REFER TO AP-880, IF HIGH TEMP ALARM o CHECK CORE FLOOD TANK PRESSURE / TEMP, IF LOW TEMP ALARM DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE PURGE SUPPLY FAN DISCHARGE DUCT THE TEMPERATURE AND PRODUCT OF COMBUSTION DETECTORS SENSE THE DISCHARGE UPSTREAM OF THE RECIRCULATION DAMPER.
THE LOW TEMPERATURE ALARM HAS NO INTERLOCKS ASSOCIATED WITH IT.
()
REFERENCES:
DRAWING 208-005 SHEETS AH-020, AND AH-15. DRAWING 308849 SENSING ELEMENT: AH-23-TS, AH-23-CE, AH-24-CE, AH-645-TS, AND RELAY 3PSFP AR-401 Rev. 17 Page 80
i 1
ENCLOS1!RL1 (Page 79 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 j
i AUX BLDG FIRE ALERT EVENT POINT 0387 INDICATED CONDITION:
RB PURGE EXHAUST DUCT TEMP IS >I35T AS SENSED BY AH-295-TS, OR PRODUCTS o
OF COMBUSTION HAVE BEEN SENSED BY AH-295-CE, OR RELAY 3PEFP HAS ACTUATED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o PURGE EXHAUST FANS AHF-7A/78 TRIP OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF THE ALARM o SECURE THE RB PURGE REFER TO OP-417 o REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE P'JRGE EXHAUST DISCHARGE DUCT THE TEMPERATURE AND PRODUCT OF COMBUSTION DETECTORS SENSE THE DISCHARGE OF THE FANS
REFERENCES:
DRAWING 208-005 SHEETS AH-020, AND AH-15, DRAWING 308849 O
SENSING ELEMENT: AH-295-CE, AH-295-TS, AND RELAY 3PEFP i
AR-401 Rev. 17 Page 81
i i
ENCLOSURE 1 (Page 80 of 185) t PSA ANNUNCIATOR RESPONSE PSA-X-03 F-03-02 l
AUXBLDG FIRE ALERT EVENT POINT 0391 INDICATED CONDITION:
TEMPERATURE -IS >135T IN SPENT FUEL AIR HANDLING FAN AHF-8A DISCHARGE o
DUCT WORK AS SENSED BY AH-314-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-8A TRIPS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF THE ALARM o. REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE SPENT FUEL COOLING UNIT DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-026, DRAWING 308849 SENSING ELEMENT: AH-314-TS AR-401 Rev. 17 Page 82
ENCLOSURE 1 (Page 81 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 i
AUX BLDG FIRE ALERT
.se e J
EVENT POINT 0394 INDICATED CONDITION:
3 TEMPERATURE IS >135'F IN SPENT FUEL AIR HANDLING FAN AHF-88 DISCHARGE o
DUCT WORK AS SENSED BY AH-409-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-8B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTICATE THE CAUSE OF THE ALARM
.o REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE SPENT FUEL COOLING UNIT DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-027 DRAWING 308849 SENSING ELEMENT: AH-409-TS AR-401 Rev. 17 Page 83
4 LNCLOSURE 1 (Page 82 of 185)
)
PSA ANNUNCIATOR RFSPONSE PSA-X-03-02 F-03-02 4
4 AUX BLDG FIRE ALERT EVENT POINT 0403 INDICATED CONDITION:
TEMPERATURE IS >135Y IN SPENT FUEL AREA AIR HANDLING FAN AHF-10 o
DISCHARGE DUCT WORK AS SENSED BY AH-377-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-10 TRIPS OPERATOR ACTIONS FOR A VALID ALARM:
3 INVESTICATE THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN TuE SPENT FUEL FLOOR AIR HANDLING 9 NIT DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMIN!NG A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-044 DRAWING 308849 SENSING ELEMENT: AH-377-TS AR-401 Rev. 17 Page 84
- ~
i O
LNCLOSURE 1 (Page 83 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0410 INDICATED CONDITION:
TEMPERATURE 15 >135T IN AUXILIARY DUILDING SUPPLY FAN DISCHARGE DUCT o
WORK AS SENSED BY AH-318-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-11A/118 FANS TRIP OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF THE ALARM o REFER TO AP-880 1
DISCUSSION:
l THIS IS INDICATIVE OF A FIRE IN THE AUXILIARY BUILDING SUPPLY FANS DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-045 DRAWING 308849
. (Q.
j SENSING ELEMENT: AH-318-TS
. AR-401 Rev. 17 Page 85
--~,-w
-.ny,w+-r---,wr
..r.,..r
,,,i,ww,,ye 3
,---.,m...-m---
--v--
l ENCLOSURE _1 (Page 84 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0416 INDICATED CONDITION:
TEMPERATURE IS >I35T IN AUXILIARY BUILDING RECIRC FAN SUC110N DUCT WORK o
AS SEN3ED BY AH-375-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-13 TRIPS OPERATOR ACTIONS FOR A val.ID ALARM:
o INVESTIGATE THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE AUXILIARY BUILDING RECIRC FAN DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-048 DRAWING 308849 SENSING ELEMENT: AH-375-TS AR-401 Rev. 17 Page 86
\\
ENCLOSURE 1 (Page 85 ni 185)
)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0426 INDICATED CONDITION:
TEMPFRATURE IS >135aF IN AUXILIARY BUILDING EXHAUST DUCT WORK AS SENSED o
BY AH-354-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
AUXILIARY BUILDING EXHAUST FANS AHF-14A, AHF-14B, AHF-14C, & AHF-140 o
TRIP OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE THE CAUSE OF THE ALARM o REFER TO /P-880 DISCUSSION:
THIS IS INDICATIVE OF A FIRE IN THE AUXILIARY BUILDING EXHAUST DISCHARGE DUCT, CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION
REFERENCES:
DRAWING 208-005 SHEETS AH-001, AND AH-005, DRAWING 308849 SENSING ELEMENT: AH-354-TS l
AR-401 Rev. 17 Page 87
1 1
i i
i ENCLOSURE 1.
(Page 86 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 1
1 i
l f
AUX BLDG FIRE ALERT
)\\
i L
EVENT POINT 0431 i
i INDICATED' CONDITION:
4 i
PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-156-CE o
TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-156-CE o
j o
TEMPERATURE > 135T AS-SENSED BY AH-156-TS EXISTS AT THE 95' LEVEL INTERMEDIATE BUILDING l
REDUNDANT INDICATION WHICH WILL VERI / ALARM:
i HIGH TEMPERATURE WILL RESULT IN THE TRIP OF AHF-24A/B IF RUNNING o
}
HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-42 AND FD-43 o
L I
OPERATOR ACTIONS FOR A VALID ALARM:-
o REFER TO THE CR3 PRE FIRE PLAN
{-
o REFER TO AP-880 i
j.
j DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE-FIRE DETECTION-CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.
j~
REFERENCES:
DRAWING 208-005 SHEETS AH-51, AND AH-55. DRAWING'308846 SENSING ELEMENT: AH-156-CE, AH-156-TS, RELAY 3AH-156-TS/RRIA j
AR-401 Rev. 17 Page 88-w-
n o-p y,m--
w w.+mn-e-,-,~,r,,vern,,,m,ws,~+-,--mm,w-e, wm, n-g-ow--=-+-r
,m--.mv-w r-,-e em me.---,-,
t,e.-
,.~-w.,
r e n-.m---mm v=,,ga w
w-
,,-,wvn-p,r-
ERCLOSURE 1 lO (Page 87 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 L
l o_
4 4
AUX BLDG FIRE ALERT i
1 j
EVENT POINT 0433 INDICATED CONDITION:
r TEMPERATURE > 135'F AS SENSED EY AH-157-TS EL*STS AT THE 95' LEVEL o
INTERMEDIATE BUILDING REDUNDANT INDICATION WHICH WILL \\ERIFY ALARM:
j HIGH TEMPERATURE WILL RESULT l'l THE A FUATION OF FD-42, AND FD-43 o
1
-}
j OPERATOR ACTIONS FOR A VAL.ID ALARM:
l o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-8GC i
a l
1 DISCUSSION:
THE IS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE 95' INTERMEDIATE BUILDING.
REFERENCES:
ORAWING 208-005 SHEETS AH-51, AND AH-55. DRAWING 308846 SENSING ELEMENTt Ah-157-TS, AR-401 Rev. 17 Page 89
ENCLOSURE 1 (Page 88 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT 1
EVENT POINT 0435 INDICATED CONDITION:
PENETRATION COOLING SUPPLY AIR DUCT TEMPERATURE UPSTREAM OF FD-32 IS o
>I35*F AS SENSED BY AH-737-TS. OR AH-737-TS TROUBLE CIRCUIT HAS ACTUATED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o FD-32 FIRE DAMPER CLOSES o LOCAL TROUBLE ALARM ON AH-737-TS OPERATOR ACTIONS FOR A VALID ALARM:
o VERIFY FD-32 CLOSED o REFER TO AP-880 i
DISCUSSION:
THIS IS INDICATIVE OF A HIGH TEMPERATURE CONDITION IN THE TURBINE BUILDING ADJACENT TO THE FAN INTAKE, OR A PROBLEM WITH-THE DETECTOR.
1
REFERENCES:
DRAWING 208-005 SHEET AH-056, DRAWING 308849 SENSING ELEMENT: AH-737-TS, AH-737-TS TROUBLE CIRCUIT 4
AR-401 Rev. 17 Page 90
O ENCLOSURE 1 (Page 89 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0437 INDICATED CONDITION:
PENETRATION COOLING SUPPLY AIR DUCT TEMPERATURE UPSTREAM OF FD-33 IS o
>135*F AS SENSED BY AH-738-TS. OR AH-738-TS TROUBLE CIRCUIT HAS ACTUATED O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o FD-33 FIRE DAMPER CLOSES o LOCAL TROUBLE ALARM ON AH-738-TS t
OPERATOR ACTIONS FOR A VALID ALARM:
o VERIFY FD-33 CLOSED DISCUSSION:
THIS IS INDICATIVE OF A HIGH TEMPERATURE CONDITICN IN THE OUTSIDE AIR INTAKE, OR OF A PROBLEM WITH THE DETECTOR
REFERENCES:
DRAWING 208-005 SHEET AH-057, DRAWING 308849 SENSING ELEMENT: AH-738-TS AND AH-38-TS TROUBLE l
AR-401 Rev. 17 Page 91
ENCLOSURE 1 Ob (Page 90 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F 03-02 AUX BLDG FIRE ALERT l
I EVENT POINT 0439 INDICATED CONDITION:
PENETRATION COOLING FAN DISCHARGE DUCT TEMPERATURE IS >110T AS SENSED o
BY AH-305-TS I
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL TROUBLE ALARM ON AH-305-TS OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE CHILL WATER IS SUPPLIED TO THE OPERATING PENETRATION COOLER t
o 'NVESTIGATE THE CAUSE OF THE HIGH TEMPERATURE ALARM o REFER TO AP-880 DISCUSSION:
THIS IS INDICATIVE OF A HIGH TEMPERATURE CONDITION IN THE DISCHARGE OF THE PENETRATION COOLING FANS, OR OF A PROBLEM WITH THE DETEC10n.
REFERENCES:
DRAWING 208-005 SHEET AH-056, DRAWING 308849 SENSING ELEMENT: AH-305-TS AR-401 Rev. 17 Page 92
~..
EELOSUBE.1 i
(Page 91 of 185) l PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 l
h AUXBLOG FIRE ALERT EVENT POINT 0513 INDICATED CONDITION:
TEMPERATURE > 135T AS SENSED BY AH-132-TS EXISTS IN CLEAN MACHINE SHOP o
AIR HANDLING UNIT AHU-2 DISCHARGE O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN A TRIP OF AHU-2 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FT9E PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPEDATURE IN THE DISCHARGE DUCT OF AHU-2.
l l
REFERENCES:
DRAWING 208-005 SHEETS AH-094, DRAWING 308846 SENSING ELEMENT: -AH-132-TS AR-401 Rev. 17 Page 93
l ENCLOSURE 1 i
l (Page 92 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-Oe F-03-02
+
AUX BLDG FIRE ALERT
~
i i
EVENT POldT 0514 INDICATED CONDITION:
TEMPERATURE > 135T AS SENSED BY AH-165-TS EXISTS IN HOT MACHINE SHOP o
AIR HANDLING UNIT AHU-3 DISCHARGE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN A TRIP OF AHU-3 l
l OPERATOR ACTIONS FOR A VALID ALAM:
l 0 REFER TO THE CR3 PRE FIRE PLAN l
o REFER TO AP-880 l
DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE DISCHARGE DU G OF AHU-3.
REFERENCES:
DRAWING 208-005 SHEETS AH-095, DRAWING 308846 SENSING ELEMLNT:. AH-165-TS l
AR-401 Rev. 17 Page 94
. - ~ _. _
i O
EHQ,050RE 1 (Page 93 ef 185)
PSA ANN 9NCIATOR RESPONSE PSA-X-03-0*
F-03-03 r
B DIESEL ROOM FIRE ALERT EVENT POINT 0460 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-364-CE TROUBLE HAS BEEN DETECTED IN THE CIRCUlTS FOR AH-364-CE o
O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AN ALARM ON AH-364-CE WILL ACTUATE FD-36 AND FD-37 OPERATOR ACTIONS FOR A VALID ALARM:
DEENERGIZE AHF-28A LOCALLY OR VIA ACDP-50 BREAKER 13 o
o REFER TO THE PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE ECDG-1A ROOM.
REFERENCES:
DRAWING 208-005 AH-073, AH-076, AND DRAWING 308849 SENSING ELEMENT: AH-364-CE, 3AH-364-CE/ RELAY AR-401 Rev. 17 Page 95
' '; CLOSURE 1 l
.ge 94 of 185)
PSA ANNUNCIATOR RESPONSE PSA- 03-03 F-03-03 l
l DIESEL ROOM FIRE ALERT EVENT POINT 0465 INDICATED CONDITION:
PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-374-CF o
TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-374-CE o
O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
AN ALARM ON AH-374-CE WILL ACTUATE FD-34 AND FD-35 o
OPERATOR ACTIONS FOR A VALID ALARM:
DEENERGIZE AHF-28B LOCALLY OR VIA ACDP-50 BREAKER 14 o
o REFER T0 THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE EGDG-IB ROOM.
REFERENCES:
DRAWING 208-005 SHEETS AH-073, AH-079, AND DRAWING 308849 SENSING ELEMENT: AH-374-CE, 3AH-374-CE/ RELAY AR-401 Rev. 17 Page 96
.. ~. _
s t
ENCLOSURE 1 (Page 95 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 04 0
j CNTRL COMPLEX FIRE ALERT l
N 7.
EVENT POINT 0481 5
INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-33-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-33-CE lo REDUNDANT INDICAT7 7 WHICH WILL VERIFY ALARM:
AN ALARM ON AH-33.er LI;.; ALLOW THE CONTROL-COMPLEX VENTILATION SYSTEM 2
o TO BE PLACED IN A. Nff N MOVAL MODE OF OPERATION 4
OPERATOR ACTIONS FOR A VALID ALARM:
I o REFER TO THE CR3 FIRE PLAN o REFER TO AP-bd0 4
DISCUSSION:-
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE COMMON RETURN DUCT DOWNSTREAM OF AHF-19A/B p
REFERENCES:
DRAWING 208-005 SHEETS AH-090, AH-079, AND DRAWING 308847 SENSING ELEMENT:
AH-33-CE, 3AH-33-CE/ RELAY AR-401 Rev. 17 Page 97
.... ~ -
l ENCLOSURE 1 (Page 96 of 185) 4 PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 4
4 l
CNTRL COMPLEX FIRE ALERT EVENT POINT 0492 l
INDICATED CONDITION:
PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-529-CE o
o TROUBLE HAS BEEN DETEGED IN THE CIRCUITS FOR AH-529-CE TFMcERATURE > 135*F AS SENSED BY AH-529-TS EXISTS AT THE 124' LEVEL OF o
4 TPE CONTROL COMPLEX REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-13 AND FD-84 i
4 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 FIRE PLAN i
o REFER TO AD-880 DISCUSSION:
_ THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION 4
CIRCUITS, OR A FIRE IN THE 124' ELEVATION OF THE CONTROL COMPLEX 3
REFERCNCES:
DRAWING 208-005-SHEETS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT: AH-529-TS AH-529-CE, 3AH-529-TS/ RELAY 4
AR-401 Rev. 17 Page 98
ENCLOSURE 1 (Page 97 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 I
~
l CNTRL COMPLEX i
l FIRE ALERT EVENT POINT 0494 INDICATED CONDITION:
-o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-214 CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-214-CE TEMPERATURE > 135T AS SENSED BY AH-214-TS EXISTS AT THE 124' LEVEL OF o
THE CONTROL COMPLEX. ES 480V "A" SWITCHGEAR ROOM w)
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-4 AND FD-16 o
OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 124' ELEVATION OF THE CONTROL COMPLEX
REFERENCES:
DRAWING 208-005 SHEETS AH-102, AH-107, AND DRAWING 308847 SENSING ELEMENT: AH-214-TS AH-214-CE, 3AH-214-TS/ RELAY AR-401 Rev. 17 Page 99
. -.. ~..
>O EHCLOSURE 1 (Page 98 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 0495 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-212-CE -
o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-212-CE o TEMPERATURE > 135aF AS SENSED BY AH-212-TS EXISTS AT THF.124' LEVEL OF A
THE CONTROL COMPLEX. ES 480V "B" SWITCHGEAR ROOM V
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-2 AND FD-14 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUB'.E IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 124' ELEVATION Cf THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SHEETS AH-102, AH-106, AND DRAWING 308847 SENSING ELEMENT: AH-212-TS AH-212-CE, 3AH-212-TS/ RELAY AR-401 Rev. Il Page 100
ENCLOSURE 1 (Page 99 of 185) v PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 0498 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-216-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-216-CE o TEMPERATURE > 135V AS SENSED BY AH-216-TS EXISTS AT THE 108' LEVEL OF THE CONTROL COMPLEX. ES 4160V "A" SWITCHCEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-6 AND FD-18 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SHEETS AH-103, AH-107, AND DRAWING 308847 SENSING ELEMENT: AH-216-TS AH-216-CE, 3AH-216-TS/ RELAY AR-401 Rev. 17 Page 101
ENCLOSURE _1 (Page 100 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04
-F-03-04 CNTRL COMPLEX FIRE ALERT i
EVENT POINT 0499 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-215-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-215-CE o TEMPERATURE > 135"F AS SENSED BY AH-215-TS EXISTS AT THE 108' LEVEL OF THE CONTROL COMPLEX. ES 4160V "B" SWITCHGEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
i o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-5 AND FD-17 4
OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHEit TROUBLE IN THE FIRE DcTECTION l
CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF THE CONTROL COMPLEX.
h
REFERENCES:
DRAWING 208-005 SHEETS AH-103, AH-107, AND ORAWING 308847 SENSING ELEMENT: AH-215-TS AH-215-CE, 3AH-215-TS/ RELAY JO i
AR-401 Rev. 17 Page 102
_ _ - _ -. ~ _
!q ENCLOSURE 1
/
U (Page 101 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 i
CNTRL COMPLEX FIRE ALERT EVENT POINT 0500 INDICATED CONDITION:
s o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-220-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-220-CE i
o TEMPERATURE > 135"F AS SENSED BY AH-220-TS EXISTS IN "A" BATTF.RY CHARGER REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-42 AND FD-43 OPERATOR ACTIONS FJR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
f THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE, OR A HIGH TEMPERATURE IN THE ROOM.
4
REFERENCES:
DRAWING 208-005 SHEET AH-104 SENSING ELEMENT: AH-220-TS, AH-220-CE
-AR-401 Rev. 17 Page 103
k ENCLOSURE 1 (Page 102 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 0501 4
- ~ _ _
INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-217-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-217-CE l.
o TEMPERATURE > 135T AS SENSED BY AH-217-TS EXISTS IN "B" BATTER) CHARGER ROOM
%/
i 4
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-19 i
OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 i
i -
DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.
RcFERENCES: DRAWING 208-005 SHEETS AH-103, AH-109, AND DRAWING 308847 SENSING ELEMENT: AH-217-TS, AH-217-CE AR-401 Rev. 17 Page 104
ENCLOSURE 1 (Page 103 of 185)
PSA ANNUNCIATOR RESPONSE-PSA-X-03-04 F-03-04 I
CNTRL COMPLEX FIRE ALERT
].
t=
EVENT POINT 0502 INDICATED CONDITION:
o PROL'UCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-219-CE I
o TROUT'LE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-219-CE o TEMPERATURE > 135'F AS SENSED BY AH-219-TS EXISTS IN "A" BATTERY ROOM i
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
4
)
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-9 AND FD-21 i
OPERATOR ACTIONS FOR A VALID ALARM:
l o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE, OR A HIGH TEMPERATURE IN THE ROOM.
REFERENCES:
DRAWING 208-005 SHEETS AH-104, AH-108, DRAWING 308847 (V
SENSING ELEMENT: AH-219-CE, AH-219-TS AR-401 Rev. 17 Page 105
' n ERCLOSURi l (Page 104 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT i
i EVENT POINT 0503 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-218-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-218-CE o TEMPERATURE > 135'F AS SENSED BY AH-218-TS EXISTS IN THE "B" BATTERY ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-220 AND FD-222 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.
REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEETS AH-103, AH-108 AND DRAWING 308847 O(y SENSING ELEMENT: AH-218-CE, AH-218-TS AR-401 Rev. 17 Page 106
s ENCLOSURE 1 (Page 105 of 185)
PSA ANNUNCIATOR RESPONSE-PSA-X-03-04 i--03-04 s
CNTRL COMPLEX FIRE ALERT i
EVENT POINT 0504 INDICATED CONDITION:
1 l
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-222-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-222-CE o TEMPERATURE > 135*F AS SENSED BY AH-222-TS EXISTS IN THE "A" INVERTER
- /"
ROOM k
l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-12 AND FD-24 L
1 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
1
'lHIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.
' REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEETS AH-104, AH-109 AND DRAWING 308847 tO SENSING ELEMENT: AH-222-CE, AH-222-TS Q
AR-401 Rev. 17 Page 107 a
_.~
ENCLOSURE 1
- Nj (Page 106 of 185)
PSA' ANNUNCIATOR RESPONSE-PSA-X-03-04 F-03-04 5
4 CNTRL Cr"APLEX
{
FIRE ALERT EVENT POINT 0505 INDICATED CONDITION:
.1 o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-221-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-221-CE i
o TEMPERATURE > 135'F AS SENSED BY AH-221-TS EXISTS IN THE "B" INVERTER ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
.o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-11 AND FD-23 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE N CECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE'IN THE ROOM.
REFER TO THE CR3 FIRE. PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEETS AH-104, AH-109 AND DRAWING 308S47 SENSING ELEMENT: AH-221-CE, AH-221-TS AR-401 Rev. 17 Page 108
l i
(/c)
ENCLOSURE _1 (Page 107 of 185) x_
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 I
i CNTRL COMPLEX FIRE ALERT EVENT POINT 0506 IcIDICATED CONDITION:
o PRODUCTS OF COM8USTION HAVE BEEN DETECTED BY AH-235-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-235-CE o TEMPERATURE > 135'F AS SENSED BY AH-235-TS EXISTS IN THE CONTROL COMPLEX STAIR WELL REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-25 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
-THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.
REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEETS AH-105, AH-109 AND DRAWING 308847 SENSING ELEMENT: AH-235-CE, AH-235-TS AR-401 Rev. 17 Page 109
=
~
ENCLOSURE 1
(
(Page 108 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04
~
j CNTRL COMPLEX FIRE ALERT i
EVENT POINT 0507 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-236-CE 4
o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-236-CE o TEMPERATURE > 135T AS SENSED BY AH-236-TS EXISTS AT THE 108' LEVEL OF THE CONTROL COMPLEX REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-26 AND FD-27 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF THE CONTROL COMPLEX cx
REFERENCES:
DRAWING 208-005 SHEETS AH-105, AH-109, AND DRAWING 308847 SENSING ELEMENT: AH-236-TS AH-236-CE, 3AH-236-TS/ RELAY AR-401 Rev. 17 Page 110 4
~
~
EXCL01DRE._1 (Page 109 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04
'F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 1532 INDICATED CONDITION:
o TEMPERATURE > 135T AS SENSED BY AH-534-TS EXISTS IN THE CONTROL COMPLEX MAIN AIR HANDLING SUPPLY DUCT AT 145' ELEVATION Dd REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-56 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE IN THE MAIN SUPPLY DUCT OF THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SH TS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT: -AH-534-TS, 3AH-534-TS/RR-HV-AU AR-401 Rev, 17 Page 111
I d
r"~
ENCLOSURE 1 4
(Page 110 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 1
i CNTRL COMPLEX t-FIRE ALERT i
EVENT POINT 1533 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-531-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-531-CE O
}
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o PRODUCTS OF COMBUSTION DETECTION WILL RESULT IN THE-ACTUATION OF FD-51 i
OPERATOR ACTIONS FOR A VALIO ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE OUTSIDE AIR INTAKE OF THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWINC 308847 (f
SENSING ELEMENT: AH-531-CE AR-401 Rev. 17 Page 112
ENCLOSURE 1 (O
y)
(Page 111 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 I
4 1
CNTRL COMPLEX FIRE ALERT EVENT POINT 1534 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-535-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-535-CE o TEMPERATURE > 135T AS SENSED BY AH-535-TS EXISTS IN THE CONTROL COMPLEX MAIN SUPPLY DUCT 95' ELEVATION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-55 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE MAIN SUPPLY DUCT OF THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT:. AH-535-TS AH-535-CE, 3AH-535-TS/ RELAY AR-401 Rev. 17 Page 113
l ENCLOSURE 1 i
(Page 112 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04~
CNTRL COMPLEX FIRE ALERT EVENT POINT 1535 INDICATED CONDITION:
o TEMPERATURE > 135T AS SENSED BY AH-533-TS EXISTS IN THE CONTROL COMPLEX MAIN RETURN AIR DUCT AT 145' ELEVATION O
V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-57 OPERATOR ACTIONS FOR A VALID ALARM:
o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:
THIS CONDITION IS INDICATIVE OF A FIRE 'IN THE RETURN AIR DUCT OF THE CONTROL COMPLEX.
REFERENCES:
DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847
.O SENSING ELEMENT: AH-533-TS, 3AH-533-TS/RR-HV-AT AR-401 Rev. 17 Page 114
. INCLOSURE 1
(
(Page 113 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 A
CNTRL COMPLEX FIRE ALERT EVENT POINT 1536 INDICATED CONDITION:
4 o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-211-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-211-CE o TEMPERATbRE > 135'F AS SENSED BY AH-211-TS EXISTS AT THE 134' LEVEL OF i G THE CONTROL COMPLEX
\\v/
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH TEMPERATURE WILL REST'LT IN THE ACTUATION OF THF. FOLLOWING:
FD-45, FD-46, FD-47, FD-81, FD-82, AND FD-83 OPERATOR ACTIONS FOR A VALID ALARM:
i o REFER TO THE CR3 PRE FIRE PLAN l
o REFET. TO AP-880 k
DISCUSSION:
(
THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 134' ELEVATION OF THE CONTROL COMPLEX IN THE CABLE SPREADING ROOM.
REFERENCES:
DRAWING 208-005 SHEETS AH-105, AH-107, AND DPS "NG 308847 SENSING ELEMENT: AH-211-TS AH-211-CE, 3AH-211-TS/ RELAY AR-401 Rev. 17 Page 115
... -... ~..
ENCLOSURE 1 (Page 114 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-05 F-03-05 1
1 RUSTY BLDG FIRE ALERT l
EVENT POINT 0427 i
INDICATED CONDITION:
j o DUCT TEMPERATURE AT DISCHARGE OF AHF-46 IS > 125T AS SENSED BY AH-667-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-46 TRIPS DUE TO INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:
o o ENSURE AHF-46 IS SHUTDOWN
.o INVESTIGATE CAUSE OF ALARM DISCUSSION:
1 THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DUCT WORK.
CONSIDERATION SHOULD BE GIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS.
AHF-46 IS THE RUSTY BUILDING RECIRC FAN.
tEFERENCES:
DRAWING 208-005 SHEET AH-142 V
SENSING ELEMENT: AH-667-TS AR-40I Rev. 17 Page 116
I ENCLOSURE 1 I..V (Page 115 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-05 F-03-05 RUSTY BLDG FIRE ALERT EVENT POINT 0512 INDICATED CONDI TON:
o DUCT TEMPERATURE AT DISCHARGE OF AHU-7 IS > 125T AS SENSED BY AH-670-TS
/]
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHU-7 ' RIPS DUE TO INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:
o ENSURE AHU-7 IS SHUTDOWN o INVESTIGATE CAUSE OF ALARM DlSCUSSION:
THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DUCT WORK.
CONSIDERATION SHOULD BE GIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS.
AHU-7 IS THE RUSTY BUILDING AIR CONDITIONING UNIT.
REFERENCES:
DRAWING 208-005 SHEET AH-144 SENSING ELEMENT: AH-670-TS AR-401 Rev. 17 Page 117
=
ENCLOSURE 1 (Page II6 of 185) w PSA ANNUNCIATOR RESPONSE PSA-X-03-06 F-03-06 FIRE PUMP HOUSE FIRE ALERT j -.
I J
EVENT POINT 0455 INDICATED CONDITION:
o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-386-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-386-CE OV REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THE FIRE PUMP HOUSE.
DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-072 SENSING ELEMENT: AH-386-CE AR-401 Rev. 17 Page 118
..~ -
. = ~..
ENCLOSURE 1 (Page 117 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-03-07 F-03-07 4
FIRE SYSTEM TROUBLE 6
EVENT POINT 0197 2
INDICATED CONDITION:
o FIRE SERVICE PANEL IN THE CONTROL ROOM HAS AN UNACKNOWLEDGED OR UNRESET ALARM i
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o ALARM ON THE FIRE SERVICE PANEL OR ONE OF THE PYROTRONICS PANELS OPERATOR ACTIONS FOR A VALID ALARM:
o IMMEDIATE INVESTIGATION OF ALARM CAUSE SHOULD BE INITIATED l
DISCUSSIGN:
REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.
4
REFERENCES:
DRAWING 208-031 SHEET FS-21 O
'D SENSING ELEMENT:
AR-401 Rev. 17 Page 119
Is ENCLOSURE 1 (Page 118 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-01 F-04-01
~
l i
I I
REACTOR BLDG I
I PURGE FAN I
I TRIP I
I l
l I
I EVENT POINT 03S4 INDICATED CONDITION:
o AHF-7A MOTOR NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-7A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE RB PURGE o REFER TO OP-417 DISCUSSION:
THIS CONDITION MAY BE CAUSED BY ACTUATION OF A FIRE ALERT IN THE DUCT INDICATED BY EVENT POINT 0387, OR AN FSV-114 DELUGE VALVE ACTUATION
REFERENCES:
DRAWING 208-005 SHEETS AH-022, AH-015 SENSING ELEMENT:
CS/SC, CS/0, 42/49B RELAY AR-401 Rev. 17 Page 120
ENCLOSURE 1 (Page 119 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-01 F-04-01 I
I REACTOR BLDG I
l PURGE FAN TRIP l
I I
I EVENT POINT 0385 INDICATED CONDITION:
o AHF-78 MOTOR NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
- o GREEN LIGHT ON WITH A RED FLAG ON AHF-7B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
. o SECURE RB PURGE o REFER TO OP-417 l
DISCUSSION:
THIS CONDITION MAY BE CAUSFD BY ACTUATION OF A FIRF ALERT ?N THE DUCT INDICATED BY EVENT POINT 0387, OR AN FSV-114 DELUGE VALVE ACTUATION
REFERENCES:
DRAWING 208-005 SHEETS AH-023, AH-015 V
SENSING ELEMENT: CS/SC, CS/0, 42/49B RELAY AR-401 Rev. 17 Page 121
O ENCLOSURE 1 (Page 120 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-02 F-04-02 AH FLTR 1 DIFF PRESS HIGH i
EVENT POINT 0497 INDICAiED CONDITION:
l o DIFFERENTIAL PRESS ACROSS AHFL-1A/1B IS > 5.2 "H,0 AS SENSED BY AH-586A-DPS,'OR AH-586B-DPS (Oj REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH FLOW INDICATED ON AH-32-FIR o LOCAL DIFFERENTIAL PRESSURE INDICATIONS ON AH-586-DPI, LOCALLY NORTH / SOUTH END (AHFL A, FILTERS D, E & F) (AHFL B, FILTERS A, B, & C)
OPERATOR ACTIONS FOR A VALID ALARM:
)
o REDUCE RB PURGE FLOW RATE o REFER TO OP-417 o VERIFY ROUGHING FILTER DP < 0.9" H,0 LOCALLY (FILTERS A/F) o VERIFY HEPA FILTER DP < 3.0" H,0 LOCALLY (FILTERS B/E)
DISCUSSION:
THIS CONDITION IS INDICATIVE OF EXCESTIVE FLOW THROUGH THE PURGE EXHAUST l
FILTERS OR A DIRTY FI!TER CONDITION
REFERENCES:
DRAWING 308848 SENSING ELEMENT: AH-586A-DPS, AH-5868-DPS AR-401 Rev. 17 Page 122
O ENCLOSURE 1 (Page 121 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 4
t 1
REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0360 INDICATED CONDITION:
o AHF-2A-MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION b)
(
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
=
o GREEN LIGHT ON WITH A RED FLAG ON AHF-2A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP REACTOR CAVITY COOLING TO "B" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 DISCUSSION:
A SUSTAINED LOSS OF COOLING TO THS REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF Tnk NUCLEAR INSTRUMENTATION.
REFERENCES:
DRAWINGS 208-005-AH-031, 308848 SENSING ELEMENT:
CS/SC, CS/0, 42B RELAY
-AR-401 Rev. 17 Page 123
l 6
l -(n]-
ENCLOSURE 1 l
(Page 122 of 185) l l
PSA ANNUNCIATOR RESPONCE PSA-X-04-03 F-04-03 REACTOR BLDG
- MISC CLG FANS TRIP EVENT POINT 0362
-INDICATED CONDITION:
o AHF-2B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-2B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 r
DISCUSSION:
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.
REFERENCES:
DRAWINGS 208-005-AH-033, 308848
' bl SENSING ELEMENT: CS/SC, CS/0, 42B RELAY-AR-401 Rev. 17 Page 124 l
. - - - - ~... -
l iO GCL01URE_1 (Page 123 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04 93 1
F 04-03 i
l l
REACTOR SLDG MISC CLG FANS r
TRIP l
EVENT POINT 0365 l
INDICATED CONDITION:
o AHF-3A MOTOR NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START l-POSITT.-
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GRFEN LIGHT ON WITH A RED FLAG ON AHF-3A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
l 0 ENSURE AHF-3B IS OPERATING l
l DISCUSSION: IF AHF-3A TRIPS, THERE IS NO IMPACT ON RMA-6 l
REFERF,NCES:
DRAWINGS 208-005-AH-036, 308848 SENSING ELEMENT: CS/SC, CS/0, 42G RELAY AR-401 Rev. 17 Page 125
.. ~. _
~...
ERCLOSRE_1
.cr (Page 124 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0368 INDICATED CONDITION:
o AHF-38 MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-3B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
l o ENSURE APF-3A IS OPERATING o TRANSFER RMA-6 SUCTION TO RB ATMOSPHERE, REFER TO OP-417 DISCUSSION:
RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE VIA EIIHER THE DUCT OF AHF-3B 0B THE R.B. ATMOSPHERE. THE TRANSFER OF THE SAMPLE POINT PER OP-417 IS A MANUAL OPERATICN REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.
Ol
REFERENCES:
DRAWINGS 208-005-AH-037 SENSING ELEMENT: 42B RELAY AR-401 Rev. 17 Page 126
ENCLOSURE 1 O
(Page 125 of 185) a PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 4
REACTOR BLDG MISC CLG FAN 8 TRIP I
J~
EVENT POINT 0371 1
INDICATED CONDITION:
o AHF-4A MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED Fl.AG ON AHF-4A CONTP,0L STATION OPERATOR ACTIONS FOR A VALID ALARM:
o STAkT AHF-4B o REFER TO OP-417 DISCUSSION:
REFERENCES:
DRAWINGS 208-005-AH-038, 308848 SENSING ELEMENT:
CS/SC. CS/0, 428 RELAY AR-401 Rev. 17 Page 127
t O
ENCLOSURE 1 (Page 126 of 185) j PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 4
REACTOR BLDG MISC CLG FANS TRIP i
EVENT POINT 0373 l
INDICATED CONDITION:
i o AHF-48 MOTOR 15 NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-4B CONTROL STATION OPERATOR ACTIG..a FOR A VALID ALARM:
o START AHF-4A o REFER TO OP-417 DISCUSSION:
REFERENCES:
DRAWINGS 208-005-AH-040, 308848 t
V SENSING ELEMENT: CS/SC, CS/0, 428 RELAY AR-401 Rev. 17 Page 128
ERCLQ1tlRE_1 (Page 127 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0378 INDICATED CONDITION:
o AHF-6A MOTOR IS NOT ENERCIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN LIGHT ON WITH A RED FLAG ON AHF-6A CONTROL STATION o LOSS OF RB PURCE FLOW AS READ ON AH-32-FIR OPERATOR ACTIONS FOR A VALID ALARM:
o START AHF-6B o REESTABLISH RB PURGE IF REQUIRED o REFER TO OP-417 DISCUSSION:
ONLY ONE PURGE SUPPLY FAN IS REQUIRED FOR ESTABLISHING AN RB PURGE, SOME OF T!!E THINGS THAT WILL CAUSE THE PURGE SUPPLY FAN TO TRIP ARE A LOSS OF EITHER OF THE PURGE EXHAUST FANS AHF-7A/AHF-78, ACTUATION OF FIRE ALERT EVENT POINT 0380
REFERENCES:
DRAWINGS 208-005 SHEETS AH-015, AH-20, DRAWING 308848 SENSING ELEMENT: CS/SC, CS/0, 428 RELAY AR-401 Rev 17 Page 129 l
ENCLOSURE 1 (Page 128 of 185) l PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0379 INDICATED CONDITION:
o AHF-6B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START F0SITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN LIGHT ON WITH A RED FLAG ON AHF-6B CONTROL STATION o LOSS OF RB PURGE FLOW AS READ ON AH-32-FIR OPERATOR ACTIONS FOR A VALID ALARM:
o START AHF-6A o REESTABLISH RB PURGE IF REQUIRED o REFER TO OP-417 DISCUSSION:
ONLY ONE PURGE SUPPLY FAN IS REQUIRED FOR ESTABLISHING AN RB PURGE, SOME OF THE THINGS THAT WILL CAUSE THE PURGE SUPPLY FAN TO TRIP ARE A LOSS OF EITHER OF THE PURGE EXHAUST FANS AHF-7A/AHF-78, ACTUATION OF FIRE ALERT EVENT POINT 0380
REFERENCES:
DRAWINGS 208-005 SHEETS AH-015, AH-21, DRAWING 308848 SENSING ELEMENT:
CS/SC, CS/0, 428 RELAY AR-401 Rev. 17 Page 130
O ERCLOSURE 1 (Page 129 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04 04 F-04-04 REACTOR BLDG MISC AIR FLOW LOW l
EVENT POINT 0364 INDICATED CONDITION:
o AHF-2A AND/OR AHF-28 CONTROL HANDLE IN NORMAL AFTER START AND A LOW DIFF.
l PRESS. <0.20" H,0 EXISTS AS SENSED BY AH-10-DPS AND/OR AH-532-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CLOSED INDICATION OF AHD-1A o CLOSED INDICATION ON AHD-1B OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP REACTOR CAVITY COOLING PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY COULD HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.
IF FLOW CANNOT BE RESTORED THEN CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE PLANT,
REFERENCES:
DRAWINGS 208-005 SHEET AH-031, DRAWING 308848 SENSING ELEMENT: CS/SC, CS/0, 428 RELAY, AH-10-DPS, AH-532-DPS AR-401 Rev. 17 Page 131
1 I
ENCLOSURL_1 (Page 130 of 185)-
PSA ANNUNCIATOR RESPONSE PSA-X-04-04 F-04-04 REACTOR BLDG MISC AIR FLOW LOW EVENT POINT 0366 INDICATED CONDITION:
o AHF-3A CONTROL HANDLE IN NORMAL AFTER START AND A LOW DIFFERENTIAL PRESSURE <0.25" H,0 EXISTS AS SENSED BY AH-13-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A VALID ALARM:
l o ENSURE AHF-3B IS OPERATING o REFER TO OP-417 o MONITOR RB TEMPS DISCUSSION:
LL65 0F THIS AIR SUPPLY FAN WILL CAUSE RB TEMPERATURES 10 INCREASE IN PLACES DUE TO A LACK OF MIXING FLOW.
REFERENCES:
DRAWINGS 208-005 SHEET AH-036, DRAWING 308848 SENSING ELEMEN": CS/SC, CS/0, 428 RELAY, AH-13-DPS AR-401 Rev. 17 Page 132
I ENCLOSURE 1 (Page 131 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04 04 F-04-04 REACTOR BLDG MISC AIR FLOW LOW 1
EVENT POINT 0369 INDICATED CONDITION:
o AHF-3B CONTROL HANDLE IN NORMAL AFTER START AND A LOW DIFFERENTIAL l
PRESSURE <0.25" H,0 EXISTS AS SENSED BY AH-15-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A VALID ALARM:
o START AHF-3A o TRANSFER RMA-6 SUCTION TO RB ATMOSPHERE, REFER TO OP-417 DISCUSSION:
RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE VIA EIIHER THE DUCT OF AHF-3B QB THE RB ATMOSPHERE. THE TRANSFER OF THE SAMPLE POINT PER OP-417 IS A MANUAL OPERATION, REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWINGS 208-005 SHEET AH-037. DRAWING 308848 SENSING ELEMENT: CS/SC, CS/0, 428 RELAY, AH-13-DPS AR-401-Rev. 17 Page 133
ENCLOSURE 1 (Page 132 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-04 F-04-04 REACTOR BLDG
~
MISC AIR FLOW LOW EVENT POINT 0375 INDICATED CONDITION:
o AHF-4A OR AHF-4B CONTROL HANDLE IN NORMAL AFTER START AND A LOW l
DIFFERENTIAL PRESSURE < 0.19" H,0 EXISTS AS SENSED BY AH-7-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A-VALID ALARM:
o START AHF-4A OR 4B AS REQUIRED o REFER TO OP-417 o MONITOR RB TEMPS DISCUSSION:
LOSS OF THE SG COOLING FANS WILL CAUSE SOME AREAS OF THE RB TO INCREASE DUE TO LACK OF MIXING FLOW.
REFERENCES:
DRAWINGS 208-005 SHEET AH-038, DRAWING 308848 SENSING ELEMENT:
CS/SC, CS/0, 428 RELAY, AH-7-DPS AR-401 Rev. 17 Page 134 l
ENCLOSURE J (Page 133 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 REACTOR BLDG FAN VlBRATION HIGH EVENT POINT 0361 INDICATED CONDITION:
o AH-11-ME HAS ACTUATED DUE TO AHF-2A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-2A o SWAP REACTOR CAVITY COOLING TO "B" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING, THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION,
REFERENCES:
DRAWING 208-005 SHEET AH-133 SENSING ELEMENT: AH-11-ME AR-401 Rev. 17 Page 135
LNCLQlML_1 l
(Page 134 cf 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 REACTOR BLOG FAN VlBRATION HIGH EVENT POINT 0363 INDICATED CONDITION:
o AH-12-ME HAS ACTUATED DOE TO AHF-2B VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o NONE OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-2B o SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY 'iO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING, THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.
A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE 1
EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION,
REFERENCES:
DRAWING 208-005 SHEET AH-133 SENSING ELEMENT: AH-12-ME AR-401 Rev. 17 Page 136
i O
ENCLOSURE 1 (Page 135 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 i
l REACTOR BLDG FAN VfBRATION HIGH EVENT POINT 0367 INDICATED CONDITION:
o AH-14-ME HAS ACTUATED DUE TO AHF-3A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-3A o ENSURE AHF-3B IS iN OPERATION DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VIBRATION FROM OUTSIDE THE
. REACTOR BUILDING, THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.
REFERENCES:
DRAWING 208-005 SHEET AH-133 SENSING ELEMENT: AH-14-ME AR-401 Rev. 17 Page 137 g
j
-.=.
l ENCLOSURE 1 (Page 136 of 185)
)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05
- 4 i
REACTOR BLDG FAN VlBRATION HIGH l
EVENT POINT 0370 INDICATED CONDITION:
o AH-16-ME HAS ACTUATED DUE TO AHF-30 VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY FH-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-3B o START AHF-3A o TRANSFER RMA-6 SUCTION TO RB ATMOSPHERE, REFER TO OP-417 DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING, THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTICATE/ REPAIR THE PROBLEM.
REFERENCES:
DRAWING 208-005 SHEET AH-134 SENSING ELEMENT: AH-16-ME AR-401 Rev. 17 Page 138
ENCLOSURE 1 (Page I37 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 REACTOR BLDG FAN VlBRATION HIGH EVENT POINT 0372 INDICATED CONDITION:
o AH-8-ME HAS ACTUATED DUE TO AHF-4A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-4A o START AHF-48 DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY 4 MONITOR THE VIBRATION FROM OUTSIDE THE
. REACTOR BUILDING. THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.
REFERENCES:
DRAWING 208-005 SHEET AH-134 SENSING ELEMENT: AH-8-ME O
-AR-401 Rev. 17 Page 139
ENCLOSURE 1 (Page 138 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 i
REACTOR BLDG FAN VfBRATION HIGH
{
nnO 4 EVENT POINT 0374 INDICATED CONDITION:
o AH-9-ME HAS ACTUATED DUE TO AHF-4B VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-4B o START AHF-4A DISCUSSION:
THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR-BUILDING. THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.
REFERENCES:
DRAWING 208-005 SHEc.T AH-134 SENSING ELEMENT: AH-9-ME O
AR-401 Rev. 17 Page 140
EMCLOSURE 1 g
(Page 139 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-07 F-04-07 REACTOR BLDG PURGE AIR FLOW LOW EVENT POINT 0381 INDICATED CONDITION:
o DIFFERENTIAL PRESSURE ACROSS AH-1-DPS IS < 0.048" H 0 WITH AHF-6A AND/OR AHF-6B CONTROL HANDLE IN NORMAL AFTER START POSITIOk REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHV-ID CLOSES OPERATOR ACTIONS FOR A VAL 7', ALARM:
o DETERMINE THE CAUSE FOR THE LOW PURGE SUPPLY FLOW, AND ADJUST THE RECIRC FLOW DAMPER CONTROL TO REESTABLISH FLOW THROUGH THE DUCT DISCUSSION:
l i
REFERENCES:
DRAWING 208-005 SHEET 20, AND DRAWING 308848 SENSING ELEMENT: AHF-6A CS/SC, CS/0, AHF-6B CS/SC, CS/0, AH-1-DPS AR-401 Rev. 17 Page 141
i l
ENCLOSURE 1 (Page 140 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X 04-07 F-04-07 REAOTOR BLDG PURGE AIA FLOW LOW EVENT POINT 0386 INDICATED CONDITION:
o DIFFERENTIAL PRESSURE ACROSS AH-296-DPS IS < 0.29" H,0 WITH AHF-7A AND/OR AHF-78 CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOW FLOW INDICATION ON AH-32-FIR POINT NUMBER 4 OPERATOR ACTIONS FOR A VALID ALARM:
o DETERMINE THE CAUSE FOR THE LOW PURGE EXHAUST FLOW, AND CORRECT IF POSSIBLE DISCUSSION:
THIS CONDITION IS INDICATIVE OF A LOSS OF INTEGRITY IN THE DUCT WORK AND SHOULD BE INVESTIGATED AS 500N AS POSSIBLE.
THIS IS AN EXPECTED ALARM DURING RB MINI-PURGE.
_l IF BOTH FANS OPERATING, ENSURE MINIMUM FLOW (20,000 CFM EACH) IS OBTAINED
REFERENCES:
DRAW 7;vG208-005 SHEET 22,ANDDRAWING3088d3 SENSING ELEMENT: AHF-7A CS/SC, CS/0, AHF-7B CS/SC, C5/
.1 296-DPS AR-401 Rev. 17 Page 142
EMCLOSURE 1 (Page 141 of 185)
PSA ANNilNCIATOR RESPONSE PSA-X-04-08 F-04-08 l
l l
l I
I CRDM SHROUD I
I COOLING FANS I
I TRIP zz + x EVENT POINT 1224 INDICATED CONDITION:
o BREAKER IN UNIT 3D OF VENT MCC 3B IS OPEN o 42/12CR RELAY FOR THIS CIRCUIT IS DEENERGIZED o AHF-51B, AHF-51F, AND AHF-513 APE NOT RUNNING O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN INDICATOR LIGHT ON VENT MCC 3B CUBICLE 3D o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:
o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:
THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE SHROUD FANS POWERED FROM-THIS BREAKER.
ELECTRICAL MAINTENANCE WILL DETERM THE FAN (S) THAT ARE SHORTED TO ENABLE THE REMAINING FANS TO BE
- RUN,
REFERENCES:
DRAWING 208-005 SHEET AH-159 SENSING ELEMENT:
42/12CR RELAY
.AR-401 Rev. 17 Page 143
ENCLOSURE 1 l p l \\)
(Page 142 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 3
CRDM SHROUD COOLING FANS TRIP EVENT POINT 1225 INDICATED CONDITION:
o BREAKER IN UNIT 8A 0F VENT MCC 3B IS OPEN o 42/34CR RELAY FOR THIS CIRCUIT IS DEENERCIZED o AHF-51C, AHF-51G,- AND AHF-51K ARE NOT RUNNING O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN INDICATOR LIGHT ON VENT MCC 3B CUBICLE 8A o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:
o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:
THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE Oft MORE OF THE SHROUD FANS POWERED FROM THIS BREAKER.
ELECTRICAL MAINTENANCE WILL DETERM THE FAN (S) THAT ARE SHORTED TO ENABLE THE REMAINING FANS TO BE RUN.
REFERENCES:
DRAWING 208-005 SHEET AH-160 SENSING ELEMENT:
42/34CR RELAY AR-401 Rev. 17 Page 144 m
1 ENCLOSILRL1 (Page 143 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 l
I I
I CRDM SHROUD COOLING FANS l
TRIP z
__ z umF z EVENT POINT 1226 INDICATED CONDITION:
o BREAKER IN UNIT 10D OF VENT MCC 3B IS OPEN o 42/42CR RELAY FOR THIS CIRCUIT IS DEEiaRGIZED o AHF-510, AHF-51H, AND AHF-51L ARE NOT RUNNING i O REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN INDICATOR LIGHT ON VENT MCC 3B CUBICLE 10D
]
o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:
o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:
THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE SHROUD FANS POWERED FROM THIS BREAKER.
ELhCTRICAL MAINTENANCE WILL DETERM THE FAN (5) THAT ARE SHORTED TO ENABLE THE REMAINDER TO BE RUN.
REFERENCES:
DRAWING 208-005 SHEET AH-161 SENSING ELEMENT:
42/42CR RELAY AR-401 Rev. 17 Page 145
O ENCLOSURE 1 (Page 144 of 185)
PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 1
I CRDM SHROUD I
COOLING FANS l
TRIP
_N EVENT POINT 1229 INDICATED CONDITION:
o BREAKER IN UNIT 8A 0F VENT MCC 3A IS OPEN o 42/32CR RELAY FOR THIS CIRCUIT IS DEENERGIZED o AHF-51A, AHF-51E, AND AHF-51I ARE NOT RUNNING O
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN INDICATOR LIGHT ON VENT MCC 3A CUBICLE 8A o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:
o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:
THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE SHROUD FANS POWERED bh09 THIS BREAKER. ELECTRICAL MAINTENANCE WILL DETERM THE FAN (S) THAT ARd SHORTED TO ENABLE THE REMAINDER TO BE RUN.
(
REFERENCES:
DRAWING 208-005 SHEET AH-158 SENSING ELEMENT: 42/32 CR RELAY AR-401 Rev. 17 Page'146
l ENCLOSURE 1 (Page 145 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 l
l AUXBLDG I
EXHAUST FAN l
TL,'
I I
EVENT POINT 0417 INDICATED CONDITION:
o AHF-14A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN LIGHT ON WITH A RED FLAG ON AHF-14A CONTROL STATION o AHF-10, AHF-11A, AHF-11B TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-14C, START AHF-14B AND AHF-14D PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
AUX BLDG EXHAUST FILTER DELUCE VALVE ACTUATION, FSV-112 WILL TRIP THIS FAN. THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.
WASTE GAS DECAY TANK OUTLET VALVES. WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS.
O REFERENCES!
DRAWING 208-005 SHEET AH-01 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 17 Page 147
ENCLOSURE 1 O
(Page 146 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 per-1 I
AUX BLDG I
I EXHAUST FAN l
l TRIP l
I I
I EVENT POINT 0419 INDICATED CONDITION:
o AHF-148 BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTEK START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-14B CONTROL STATION o AHF-10, AHF-11A, AHF-11B TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-140, START AHF-14A AND AHF-14C PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
i AUX BLDG EXHAUST FILTER DELUGE VALVE ACTUATION, FSV-110 WILL TRIP THIS FAN. WASTE CAS DECAY TANK OUTLET VALVES. WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS.
THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.
REFERENCES:
' DRAWING 208-005 SHEET AH-02 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 17 Page 148
ENCLOSURE 1 (Page 147 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 l
l l
l 1
1 AUX BLDG I
I EXHAUST FAN l
I I
1 TRIP I
I I
i l.
I I
l EVENT POINT 0421 INDICATED CONDITION:
o AHF-14C BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT WITH A RED FLAG ON AHF-14C CONTR'. STATION d
o AHF-11A, AHF-118, AHF-10 TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:
-o SECURE AHF-14A, START AHF-14B AND AHF-140 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
AUX BLDG EXHAUST FILTER DELUGE VALVE ACTUATION, FSV-116 WILL TRIP THIS FAN THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.
WASTE CAS DECAY TANK OUTLET VALVES, WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS.
O
REFERENCES:
DRAWING 208-005 SHEET A'l-03 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 17 Page 149
ENCLOSURE 1 (Page 148 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 l
l l
l l
AUX BLDG l
I EXHAUST FAN l
l TRIP I
I I
I EVENT POINT 0423 (NDICATEDCONDITION:
o AHF-14D BREAKER OPEN WITH C0tuR'S HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o CREEN LIGHT ON WIT 4 A RED FLAG ON AHF-140 CONTROL STATION o AHF-10 AHF-11A, AHF-11B TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-148, START AHF-14A AND AHF-14C o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
AUX BLDG EXHAUST FILTER DELUGE VALVE ACTUATION, FSV-118 WILL TRIP THIS FAN THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE TAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE H\\AC PANEL.
WASTE GAS DECAY TANK OUTLET VALVES WDV-436, 437, 438 WILL CLOSE F THIS FAN TRIPS.
REFERENCES:
DRAWING 208-005 SHEET AH-04 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 17 Page 150
I ENCLOSURE 1 (Page 149 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 i
AUX BLDG EXHAUST FAN OVERLOAD EVENT POINT 0418 l
INDICATED CONDITION:
f o AHF-14A MOTOR AMPS >115% RATED LOAD I
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-14A TRIPS o AHF-14A HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FO. A VALID ALARM:
o SECURE AHF-14A AND AHF-14C, START AHF-14B AND AHF-140 AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.
REFERENCES:
DRAWINC 208-005 SHEET AH-01 SENSING-ELEMENT:
74-AHF-14A AR-401 Rev. 17 Page 151'
I I
ENCLOSURE 1 (Page 150 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 AUX BLDG EXHAUST FAN OVERLOAD EVENT POINT 0420 INDICATED CONDITION:
o AHF-148 MOTOR AMPS >115% RATED LOAD REOUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-14B TRIPS o AHF-14B HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-148 AND AHF-14D START AHF-14A AND AHF-14C AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.
REFERENCES:
DRAWING 208-005 SHEET AH-02 SENSING ELEMENT:
74-AHF-14B AR-401 Rev. 17 Page 152 27
ENCLOSURE 1
-)N (Page 151 of 185)
Q J
L PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 i
l l
[
i AUX BLDG EXHAUST FAN OVERLOAD EVENT POINT 0422 l
INDICATED CONDITION:
o AHF-14C MOTOR AMPS >115% RATED LOAD REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-14C TRIPS o AHF-14C HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-14A AND AHF-14C, START AHF-14B AND AHF-14D AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVC ACTUATED.
INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TkiP THE B".EAKER.
REFERENCES:
DRAWING 208-005 SHEET AH-03 SENSING ELEMENT:
74-AHF-14C AR-401 Rev. 17 Page 153 w
ENCLOSURE-1 1,O (Page 152 of 185)
V PSA-X-05-02 h 02 PSA-F ANNUNCIATOR RESPONSE d
1 AUX BLDG EXHAUST FAN OVERLOAD EVENT PolNT 0424 INDICATED CONDITION:
o AHF-14D MOTOR AMPS >115% RATED LOAD REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-14D TRIPS o AHF-14D HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:
o SECURE AHF-14B AND AHF-14D, START AHF-14A AND AHF-14C AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o IM/ESTIGATE CAUSE OF FAN TRIP DISCUSSION:
THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT
. PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.
REFERENCES:
DRAWING 208-005 SHEET AH-04 SENSING ELEMENT:
74-AHF-14D AR-401 Rev. 17 Page 154
Y i (g ENCLOSURE 1 l-(j (Page 153 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 f
AB FLTR 2A/8/C/D AP HIGH EVENT POINT 1552 INDICATED CONDITION:
o AUX BUILDING EXHAUST FILTER, AHFL-2A, FLOW IS >5.2" H,0 AS SENSED BY AH-601-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHFL-2A LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A VALID ALARM:
o NOTIFY HVAC TO INSPECT FILTER DISCUSSION:
OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.
REFERENCES:
DRAWING 208-005 SHEET AH-131 SENSING ELEMENT: AH-601-DPS AR-401.
Rev. 17 Page 155
\\
',es ENCLOSURE 1 (Page 1P; of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 AB FLTH 2A/B/C/D AP HIGH EVENT POINT 1553 INDICATED CONDITION:
o AUX BUILDING EXHAUST FILTER, AHFL-2B, FLOW IS >5.2" H,0 AS SENSED BY AH-602-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHFL-2B LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A VALID ALARM:
o NOTIFY HVAC TO INSPECT FILTER DISCUSSION:
OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.
REFERENCES:
DRAWING 208-005 SHEET AH-131
(
SENSING ELEMENT: AH-602-DPS AR-401 Rev. 17 Page 156
ENCLOSURE 1-(Page 155 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 AB FLTR 2A/B/C/D AP HIGH l
EVENT POINT 1688 INDICATED CONDITION:
o AUX BUILDING EXHAUST FILTER, AHFL-2C, FLOW IS >5.2" H,0 AS SENSED BY AH-603-DPS REDUNDANT '.NDICATION WHICH WILL VERIFY ALARM:
o AHFL-2C LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A VALID ALARM:
o NOTIFY HVAC TO INSPECT FILTER.
DISCUSSION:
OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.
REFERENCES:
DRAWING 208-005 SHEET AH-131 SENSING ELEMENT: AH-603-DPS AR-401 Rev. 17 Page 157
ENCLOSURE 1
(-
(Page 156 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 AB FLTR 2A/B/C/D AP HIGH l
l -.
l l
EVENT POINT 1689 INDICATED CONDITION:
o AUX BUILDING EXHAUST FILTER, AHFL-20, FLOW IS >5.2" H,0 AS SENSED BY AH-604-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
t o AHFL-2D LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A VALID ALARM:
o NOTIFY HVAC TO INSPECT FILTER DISCUSSION:
OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.
REFERENCES:
DRAWING 208-005 SHEET AH-131
)
SENSING ELEMENT: AH-604-DPS AR-401 Rev. 17 Page 158
ENCLOSURE 1 e'
~f (Page 157 of 185)
PSA-F ANNUNCIATOR RESPONSE-PSA-X-05-04 F-05-04 PENETRATION AIR FLOW TROUBLE EVENT POINT 0438 INDICATED CONDITION:
o PENETRATION COOLING AIR FLOW I! -0.018" H 0 AS SENSED BY AH-30-DPS WITH EITHERAHF-9AORAHF-98CONTROLSTATIONIbNORMALAFTERSTART REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL DIFFERENTIAL FLOW INDICATION OPERATOR ACTIONS FOR A VALID ALARM:
o START BACKUP PENETRATION COOLING FAN o REFER TO OP-417.
DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-56 O
SENSING ELEMENT: AH-30-DPS AR-401 Rev. 17 Page 159
ENCLOSURE 1 (Page 158 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 FIRE PP HOUSE FAN TROUBLE EVENT POINT 0454 INDICATED CONDITION:
o FIRE PUMP HOUSE VENTILATION AIR FLOW IS <0.25" H 0 AS SENSED BY EITHER AH-168-DPSANDAHF-33A15RUNNINGORBYAH-173-Db5ANDAHF-338 RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL-DIFFERENTIAL FLOW INDICATION OPERATOR ACTIONS FOR A VALID ALARM:
o START BACKUP FIRE PUMP HOUSE FAN o CHECK FIRE PUMP HOUSE INLET FILTERS AND OUTLET REGISTERS FOR PROPER OPERATION DISCUSSION:
FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS.
REFERENCES:
DRAWING 208-005 SHEET AH-71 SENSING ELEMENT: AH-173-DPS, AH-168-DPS AND CONTROL STATION CONTACTS AR-401 Rev. 17 Page 160
ENCLOSURE 1
(
(Page 159 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 FIRE PP HOUSE FAN TROUBLE EVENT POINT 1537 INDICATED CONDITION:
o AHF-33A BREAKER CLOSED A!
CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o RED LIGHT ON WITH A GREEN FLAG ON AHF-33A CONTROL STATION o TEMPERATURE IN FIRE PUMP HOUSE >85* F.
o ANY FIRE PUMP RUNNING OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF AUTO START DISCUSSION:
FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS. AT LEAST ONE FAN MUST BE IN OPERATION ANY TIME A FIRE PUMP IS IN OPERATION.
REFERENCES:
DRAWING 208-005 SHEET AH-71 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS
.(
4 AR-401 Rev. 17 Page 161
4 ENCLOSURE 1 l,O G
(Page I60 of 185) 1 PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 J
FIRE PP HOUSE FAN TROUBLE a
2 EVENT POINT 1538 INDICATED CONDITION:
o AHF-338 BREAKER CLOSED AND CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
J o RED LIGHT ON WITH A GREEN FLAG ON AHF-33B CONTROL STATION o TEMPERATURE IN FIRE PUMP HOUSE >85* F.
o ANY FIRE PUMP RUNNING
[
OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF AUTO START DISCUSSION:
l FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS. AT LEAST ONE FAN MUST BE IN OPERATION ANY TIME A FIRE PUMP IS IN OPERATION,
REFERENCES:
DRAWING 208-005 SHEET AH-72 4
SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 17 Page 162
3 ENCLOSURE 1
[
(Page 161 of 185)
I PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 I
DIESEL GEN RM FAN TROUBLE
-EVENT POINT 0456 INDICATED CONDITION:
o AHF-22A BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START j
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
i o GREEN LIGHT ON WITH A RED FLAG ON AHF-22A CONTROL STATION
)
OPERATOR ACTIONS FOR A VALID ALARM:
o IF EGDG-1A IS RUNNING ENSURE AHF-228 IS RUNNING o INVESTIGATE CAUSE OF FAN TRIP j
i a
DISCUSSION:
l DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-19-SS.
SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM,
REFERENCES:
DRAWING 208-005 SHEET AH-75 SENSING ELEMENT:
CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 163
ENCLOSURE 1 I
(Fage I62 of 185) l PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 0457 INDICATE 9 CONDITION:
o AHF-22B BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START
{
I REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-22B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o IF EGDG-IA IS RUNNING ENSURE AHF-22A IS RUNNING o INVESTIGATE CAUSE-0F FAN TRIP DISCUSSION:
l DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-19-SS.
SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-74 SENSING ELEMENT: CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 164 m
h ENCLOSURr__t (Page 163 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06 F-06-03 i
l DIESEL GEN RM FAN TROUBLE EVENT POINT 0458 INDICATED CONDITION:
o DIESEL GENERATOR "A" ROOM DUCT AIR FLOW <0.25" H'0 AS SENSED BY-AH-359B-DPS WITH AHF-22B OR AH-359A-DPS WITH AHF-22A ON REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL FLOW INDICATION ON JOHNSON CONTROL PANEL OPERATOR ACTIONS FOR A VALID ALARM:
o IF EGDC-1A IS RUNNING SWAP OPERATING AHF-22 FANS o NOTIFY AUX BLDG OPERATOR TO ENSURE INLET FILTERS ARE CLEAR OF DEBRIS AND 1
OBSTRUCTIONS TO AIR-FLOW DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-74 SENSING ELEMENT: AH-359B-DPS, AH-359A-DPS AR-401 Rev. 17 Page 165
ENCLOSURE 1 (Page 164 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 0459 INDICATED CONDITION:
o DIESEL GENERATOR "A" CONTROL ROOM TEMPERATURE IS >118' F AS SENSED BY AH-540-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH AMBIENT TEMPERATURE CONDITIONS ~IN THE "A" DIESEL GENERATOR CONTROL ROOM OPERATOR ACTIONS FOR A VALID ALARM:
i o INSPECT "A" DIESEL GENERATOR CONTROL ROOM FOR ANY SIGNS OF A FIRE
- o LOWER TEMPERATURE BY STARTING AHF-22A OR-228 o ENSURE AHF-28A IS RUNNING i
DISCUSSION:
HIGH AMBIENT TEMPERATURES IN THE CONTROL ROGM CAN ADVERSELY IMPACT THE OPERABILITY OF THE EMERGENCY DIESEL GENERATORS
REFERENCES:
DRAWING 208-005 SHEET AH-76 SENSING ELEMENT: AH-540-TS AR-401 Rev. 17 Page 166
ENCLOSURE 1-l (Page 165 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 l
I l
DIESEL GEN RM FAN TROUBLE EVENT POINT 0461 INDICATED CONDITION:
o AHF-22C BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START h
Ad REDUNDANT INDICATIC'? WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-22C CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o IF EGDG-1B IS RUNNING FNSURE AHF-22D IS RUNNING o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
l DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-20-SS.
SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM, l
REFERENCES:
DRAWING 208-005 SHEET AH-77 SENSING ELEMENT: CONTROL SWITCH CONTACTS AR-401 Rev 17 Page 167 V
_ ~ - - - - - _ - - - - - - -
m-ENCLOSURE 1
{
I (Page 166 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 d
DIESEL GEN RM FAN TROUBLE 1
EVENT POINT 0462 INDICATED CONDITION:
o AHF-220 BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-22D CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
-o IF EGDG-1B IS RUNNING ENSURE AHF-22C IS RUNNING o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:
l DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <81J RPM AS SENSED BY EG-20-SS.
SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-78 l SENSING ELEMENT:
CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 168
~ _. -. _ _ _ _.. _ _. _ _. _ _ _ _ _ -. _. _ _. _ _.
ENCLOSURE 1 i
,O _
kJ (Page 167 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 2
DIESEL GEN RM FAN TROUBLE EVENT POINT 0463 i
d INDICATED CONDITION:
o DIESEL GENERATOR "B" ROOK DUCT AIR FLOW <0.25" H'0 AS SENSED BY
+
]
AH-3698-DPS WITH AHF-22D OR AH-369A-DPS WITH AHF-22C ON REDUNDANT INDICATION WHICH MLL VERIFY ALARM:
o LOCAL FLOW INDICATION ON JOHNSON CONTROL PANEL
?
OPERATOR ACTIONS FOR A VALID ALARM:
o IF EGDG-1B IS RUNNING SWAP OPERATING AHF-22 FANS o NOTIFY AUX BLDG OPERATOR TO ENSURE INLET FILTERS ARE CLEAR OF DEBRIS AND OBSTRUCTIONS TO AIR FLOW DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-77 SENSING ELEMENT: AH-3698-DPS. AH-369A-DPS AR-401 Rev. 17 Page 169
l i
FNCLOSURE 1
'(
(Page 168 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE
~
EVENT POINT 0464 INDICATED CONDITION:
o DIESEL GENERATOR "B" CONTROL ROOM TEMPERATURE IS >118" F AS SENSED BY AH-541-TS' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o HIGH AMBIENT TEMPERATURE CONDITIONS IN THE DIESEL GENERATOR CONTROL ROOM OPERATOR ACTIONS FOR A VALID ALARM:
o INSPECT "B" DIESEL GENERATOR CONTROL ROOM FOR ANY SIGNS OF A FIRE o LOWER TEMPERATURE BY STARTING AHF-22C OR 22D o ENSURE AHF-28B IS RUNNING DISCUSSION:
o HIGH AMBIENT TEMPERATURES IN THE CONTROL ROOM CAN ADVERSELY IMPACT THE OPERABILITY OF THE EMERGENCY DIESEL CENERATORS
REFERENCES:
DRAWING 208-005 SHEET AH-79 O)
(
SENSING ELEMENT: AH-541-TS AR-401 Rev. 17 Page 170
n ENCLOSURE 1-(
(Page 169 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 1539 INDICATED CONDITION:
o AHF-22A BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o RED LIGHT ON WITH A GREEN FLAG ON AHF-22A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF FAN AUTO START DISCUSSION:
l DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-19-SS.
= STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-74
('%
.()
SENSING ELEMENT:
CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 171
ENCLOSURE 1 (Page 170 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 1
DIESEL GEN RM FAN TROUBLE EVENT POINT 1540 INDICATED CONDITION:
l o EGDG-1A SPEED IS >810 RPM AS SENSED BY EG-19-SS AND AHF-22A AND AHF-22B
.ARE NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o EGDG-1A READY OR RUN LIGHT ON AND AHF-22A AND AHF-22B GREEN INDICATORS ON OPERATOR ACTIONS FOR A VALID ALARM:
o START AHF-22A AND/OR AHF-22B DISCUSSION:
DIESEL-GENERATOR FANS PROVIDE COOLING FOR THE DIESEL GENERATOR ROOM.
OPERATION OF THE EMERGENCY DIESEL GENERATOR WITH NO COOLING FANS RUNNING MUST BE CLOSELY MONITORED SO AS TO NOT EXCEED 105' ROOM TEMPERATURE.
REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEET AH-74 SENSING ELEMENT:
3 ERA AND BREAKER CONTACTS AR-401 Rev. 17 Page 172
ENCLOSURE 1 (Page 171 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE l-.
l EVENT POINT 1541 INDICATED CONDITION:
o AHF-22B BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o RED LIGHT ON WITH A GREEN FLAG ON AHF-22B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF FAN AUTO START DISCUSSION:
l DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-19-SS.
STARTING THE FAN LOCALLY-WILL ACTUATE THIS ALARM.
REFERENCES:
DRAWING 208-005 SHEET AH-75 OV SENSING ELEMENT:
CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 173
I ENCLOSURE 1-(Page 172 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F 06-03 l
l l
DIESEL GEN RM FAN TROUBLE
{
EVENT POINT 1542 INDICATED CONDITION:
o AHF-22C BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o RED LIGHT ON WITH A GREEN FLAG ON AHF-22C CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF FAN AUTO START DISCUSSION:
l DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-20-SS.
STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM, t
REFERENCES:
DRAWING 208-005 SHEET AH SENSING ELEMENT:
CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 174
ENCLOSURE 1 (Page 173 of 185)
-PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 l
DIESEL GEN RM l
FAN TROUBLE EVENT POINT 1543 l
I
-INDICATED CONDITION:
l-o EGDG-1B SPEED IS >810 RPM AS SENSED BY EG-20-SS AND AHF-22C AND AHF-22D ARE NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o EGDG-1B READY OR RUN LIGHT ON AND AHF-22C ANC AHF-22D GREEN INDICATORS ON OPERATOR ACTIONS FOR A VALID ALARM:
o START AHF-22C AND/OR AHF-22D DISCUSSION:
DIESEL GENERATOR FANS PROVIDE COOLING FOR THE DIESEL GENERATOR ROOM.
OPERATION OF THE EMERGENCY DIESEL GENERATOR WITH NO COOLING FANS RUNNING MUST BE CLOSELY MON ~.YORED SO AS NOT TO EXCEED 105' ROOM TEMPERATURE.
REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-005 SHEET AH-77 SENSING ELEMENT: 3 ERB AND BREAKER CONTACTS AR-401 Rev. 17 Page 175
i ENCLOSURE 1 (Page 174 of _185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE L -..
l EVENT POINT 1544 INDICATED CONDITION:
o AHF-22D BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP rS
(
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
I o RED LIG.?T ON WITH A GREEN FLAG ON AHF-22D CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE-CAUSE OF FAN AUTO START DISCUSSION:
l DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-20-SS, STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM,
REFERENCES:
DRAWING 208-005 SHEET AH-78 SENSING ELEMENT: CONTROL SWITCH CONTACTS AR-401 Rev. 17 Page 176
ENCLOSURE 1
(
(Page 175_of 185) l PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 T-SAMPLING ROOM FAN TROUBLE EVENT POINT 0508 INDICATED CONDITION:
o AHF-44A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-44A CONTROL STATION o T0XIC GAS ACTUATION o RADIATION HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF FAN TRIP o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION o REFER TO AP-250 OR AP-513 DISCUSSION:
DUCTWORK TEMPERATURE >135' AS SENSED BY AH-402-TS WILL TRIP THIS FAN.
AHF-20A MUST BE RUNNING IN EITHER FAST OR SLOW FOR THIS FAN TO RUN.
REFERENCES:
DRAWING 208-005 SHEET AH-98 SENSING ELEMENT: CONTROL STATION CCITACTS AR-401 Rev. 17 Page 177
ENCLOSURE 1 (Page 176 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 l
SAMPLING ROOM FAN TROUBLE EVF.NT POINT 0509 INDICATED CONDITION:
o AHF-44B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL t.FTER START POSITION
)
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-448 CONTROL STATION o T0XIC GAS ACTUATION o RADIATION HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE- 0F FAN TRIP o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION o REFER TO AP-250 OR AP-513 DISCUSSION:
DUCTWORK TEMPERATURE >135" AS SENSED BY AH-545-TS WILL TRIP THIS FAN.
AHF-20B MUST BE RUNNING IN EITHER FAST OR SLOW FOR THIS FAN TO RUN.
REFERENCES:
DRAWING 208-005 SHEET AH-99 (O
<j SENSING ELEMENT:
CONTROL STATION CONTACTS AR-401 Rev. 17 Page 178
f ENCLOSURE 1
(
(Fage 177 of 185)
PSA-F ANNUNCIATOR RESPONSE-PSA-X-06-04 F-06-04 SAMPLING ROOM
. FAN TROUBLE l
EVENT POINT WO INDICATED CONDITION:
o AHF-44A DUCTWORK TEMPERATURE >135'F AS SENSED BY AH-402-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-44A TRIPS o WHITE " TEMP NORM" LIGHT IS OUT FOP AHF-44A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF HIGH TEMP o IF FIRE CONDITIONS EXIST REFER TO AP-880 o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-98 SENSING ELEMENT: AH-402-TS AR-401 Rev. 17 Page 179
(
ENCLOSURE 1 (Page 178 of 185)
PSA-F ANNONCIATOR RESPONSE PSA-X-06-04 F-06-04 1
SAMPLING ROOM FAN TROUBLE EVENT POINT 0511 INDICATED CONDITION:
l o AHF-44A EXHAUST FLOW <0.10" H,0 AS SENSED BY AH-403-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOW FLOW ON LOCAL INDICATION FOR AHF-44A OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF LOW FLOW o CONSIDERATION SHOULD BE GIVEN TO SWAPPING TO "B" SIDE CONTROL COMPLEX VENTILATION o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:
AHF-20A MUST BE RUNNING PRIOR TO STARTING AHF-44A
REFERENCES:
DRAWING 208-005 SHEET AH-98 SENSING ELEMENT: -AH-403-DPS AR-401 Rev. 17 Page 180
GCLOSURE 1 (Page 179 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMPLING ROOM FAN TROUELE EVENT POINT 1530 INDICATED CONDITION:
o AHF-44B EXHAUST FLOW <0.10" H,0 AS SENSED BY AH-544-DPS r
REDUNDANT INI,.3 TION WHICH WILL VERIFY ALARM:
o LOW FLOW ON LOCAL INDICATION FOR AHF-44B OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF LOW FLOW o CONSIDERATION SHOULD BE GIVEN TO SWAPPING TO "A" SIDE CONTROL COMPLEX VENTILATION o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION D:SCUSSION:
AHF-20B MUST BE RUNNING PRIOR TO STARTING AHF-448
REFERENCES:
DRAWING 208-005 SHEET AH-99 SENSING ELEMENT: AH-544-DPS AR-401 Rev. 17 Page 181-
l ERCLOSURE 1 (Page 180 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMi' LING RO iM FAN TROUBLE i-a EVENT PolNT 1531 l
INDICATED CONDITION:
l o AHF-44B OUCTWORK TEMPERATURE >I35T AS SENSE'1 BY AH-545-TS l
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o AHF-44B TRIPS o WHITE " TEMP NORM" LIGHT IS OUT FOR AHF-44B CONTROL STATION t
OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE CAUSE OF HIGH TEMP o IF FIRE CONDITIONS EXIST REFER TO AP-880 o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:
i
REFERENCES:
DRAWING 208-005 SHEET AH-99 SENSING ELEMENT: AH-545-TS 1
AR-401 Rev. 17 Page 182
l ENCLOSUBL1 O
(Page 181 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-05 F-06-0$
INTERMEDIATE BLDG FAN TROUBLE l
EVENT FOINT 0376 INDICATED CONDITION:
o AHF-24A BREAKER CLOSED AND DISCHARGE DAMPER AHD-67 CLOSED l
REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL DAMPER INDICATION OPERATOR-ACTIONS FOR A VALID ALARM:
o SHUTDOWN AHF-24A o SWAP TO "B" SIDE INTERMEDIATE BUILDING FANS PER OP-409 DISCUSSION:
OPERATION OF AHF-24A WITH THE DISCHARGE DAMPER CLOSED MAY CAUSE FAN DAMAGE.
REFERENCES:
DRAWING 208-005 SHEET AH-51 SENSING ELEMENT:
2-AHF-24A, AHF-24A-KS AR-401 Rev. 17 Page 183
IKLoiuBC.1 (Page 182 of 485)
PSA-F ANNUNCIATOR RESPON$E PSA-X-06 05 F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 0377 INDICATED CONDITION:
o AHF-24B BREAKER CLOSED AND ITS DISCHARGE DAMPER AHD-68 CLOSED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o LOCAL DAMPER INDICATION OPERATOR ACTIONS FOR A VALID ALARM:
o SHUTDOWN AHF-24B o SWAP TO "A" SIDE INTERMEDIATE BUILDING FANS PER OP-409 DISCUSSION:
OPERATION OF AHF-24B WITH THE DISCHARGE DAMPER CLOSED MAY CAUSE FAN DAMAG
REFERENCES:
DRAWING 208-005 SHEET AH-52 SENSING ELEMENT:
2-AHF-24B,'AHF-24B-KS AR-401 Rev. 17 Page 184
ENCLOSURE 1 (Page 183 of 185)
PSA-F ANNUNCIAT03 RESPONSE PSA-X-06-05 F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 1548
==
INDICATED CONDITION:
o AHF-29A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON-AHF-29A CONTR01 STATION OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP TO "B" SIDE INTERMEDIATE BUILDING FANS PER OP-409 o INVESTICATE CAUSE OF FAN TRIP DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-53 SENSING ELEMENT: CONTROL STATION CONTACTS AR-401 Rev. 17 Page 185
ERCLOSURE 1 (Page 184 of 185)
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-05 F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 1549 INDICATED CONDITION:
o AHF-29B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION-REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o GREEN LIGHT ON WITH A RED FLAG ON AHF-29B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:
o SWAP TO "A" SIDE INTERMEDIATE BUILDING FANS PER OP-409 o INVESTIGATE CAUSE 0F FAN TRIP DISCUSSION:
REFERENCES:
DRAWING 208-005 SHEET AH-54 SENSING ELEMENT:
CONTROL STATION CONTACTS
'AR-401 Rev. 17 Page 186
i ENCLOSURE 1 (Page 185 of 185)
(
PSA-F ANNUNCIATOR RESPONSE PSA-X-06-08 F-06-08 i
l I
l REACTOR BLDG I
PERSONNEL DOOR l
OPEN n
EVENT POINT 1212 INDICATED CONDITION:
o REACTOR BUILDING PERSONNEL OR EQUIPMENT HATCH INNER OR OUTER DOOR NOT CLOSED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:
o RB DOOR INDICATION PANEL MCB PSA SECTION OPERATOR ACTIONS FOR A VALID ALARM:
o INVESTIGATE OPEN HATCH o REFER TO OP-417 DISCUSSION:
REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.
REFERENCES:
DRAWING 208-064 SHEET ME-04 SENSING ELEMENT:
ME-1,3,5&7-KS AR-401 Rev. 17 Page 187 (LAST PAGE)