REGISTRY OF. RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.:-NR-396-D-101-B DATE:
PAGE 1 OF 8 pg j
)ggg DEVICE TYPE:
Thickness Gauge MODEL:
RSS-06 MANUFACTURER / DISTRIBUTOR:
Integrated Industrial Systems, Inc.
475 Main Street Yalesville, CT 06492 SEAT.RD SOURCE MODEL DESIGNATION:
Amersham Corp. Model AMC.19 BEBIG Trade, Inc. Model Aml.G44 ISOTOPE:
MAXIMUM ACTIVITY:
Americium-241 1.0 Curie (37 GBq)
T.RAK TEST FREOUENCY:
6 Months PRINCIPAL USE:
(D) Gamma Gauge CUSTOM DEVICE:
YES X
NO 9804060129 980318
~
PDR RC SSD ppR l
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN.ITS ENTIRETY)
NO.: NR-396-D-101-B DATE:
MMR 1 g 1998 PAGE 2 OF 8 DEVICE TYPE:
Thickness Gauge DESCRIPTION:
.The Integrated Industrial Systems, Inc. (I2S) Model RSS-06 is used for the measurement of the' thickness of various materials, customarily in the sheet metal industry.
The device consist of a C-Frame with a measuring gap that varies according to the application.
The measuring gap has a maximum dimension of 3.94" (10 cm).
The C-Frame has the following variable dimensions:
Maximum Minimum (inches)
(cm)
(inches)
(cm)
Length 101.25 257.18 18 45.72 Height 16.5 41.91 15 38.1 The C-Frame is 9" (22.86 cm) wide.
It is a welded assembly constructed of 0.375" (9.53 mm) low carbon steel.
The radioactive source is mounted in the base of the device and j
is fixed in place by a source holder which is mounted within a steel source housing.
The sealed source contains americium-241 with a maximum activity of 1 curie.
The americium-241 source contains radioactive material incorporated in a ceramic enamel which is sealed in a welded stainless steel capsule.
The source
~is distributed by Amersham Corporation and is registered with the State of Illinois as the Model AMC.19.
An alternative source is distributed by BEBIG Trade, Inc. and is registered with the State of Illinois as the Model Aml.G44.
The source housing is approximately 6" x 6" x 4" (15.24 cm x 15.24 cm x 10.16 cm) and constructed of carbon steel.
1 1
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
PAGE 3 OF 8 NO.: NR-396-D-101-B DATE:
ggg j g gggg DEVICE TYPE:
Thickness Gauge DESCRIPTION (Cont'd)-
The top of the housing has 1.7" (4.23 cm) diameter window which is covered with 0.002" (0.051 mm) thick stainless steel and includes a bronze collimating assembly.
The source is housed in a stainless steel holder which is equipped with a bronze shutter, 0.125" (3.18 mm) thick.
The shutter is controlled by a rotary solenoid which is equipped with a spring to hold the shutter in the closed position.
When power is supplied to the solenoid, the shutter rotates to the open position.
Mounted on top of the C-Frame are two lights, one red and one green.
The green light indicates the source is covered (closed) and the red that the source is exposed (open).
This may be physically verified by looking through a glass peep hole on the front of the source-housing.
Green and red strips are painted on the shutter to correspond to the indicator lights.
The device is designed so that the shutter mechanism will automatically close when there is no material in the measuring gap of the C-Frame, when power is lost, or when the receiver head is removed from the C-Frame.
LABELING:
The' device contains three labels.
The first has a yellow background, black letters, with a magenta trefoil symbol, as defined in Section 20.1901, 10 CFR Part 20.
The label also in~cludes the isotope, activity, model number, serial number, date of assay of the source, and the name and complete address of I2g,
REGISTRY OF' RADIOACTIVE SEALED SOURCES AND DEVICES
. SAFETY EVALUATION OF-DEVICE-(AMENDED IN ITS ENTIRETY)
NO.: NR-396-D-101-B DATE:
NRR 181998 PAGE 4 OF 8 DEVICE TYPE:
Thickness Gauge LABELING (Cont'd):
The second. label also has a yellow background, black letters, with a magenta' trefoil symbol.
It includes a warning to not remain within 3 feet of the device, indicates that the green
. light means the. source is "OFF",
and warns not to place hands within the measuring gap.
The third label has a black background with white letters.
It contains wording which meets the requirements of 10 CFR 32.51(a) (3) (iii).
A copy of the label is shown in attachment 2.
When distributed to specific licensees, the first sentence of the paragraph on the label is removed.
All three labels contain a caution against removing the label.
DIAGRAM:
See attachments 1 and 2.
CONDITIONS OF NORMAL USE:
The Model RSS-06 thickness gauge is designed to measure the thickness of. thin sheets of various types'of metals.
The device will typically _be used on rolling mills in a factory environment by metal producers..The device is not likely to be subjected to extremes of environmental or operating conditions.
4
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
PAGE 5 OF 8 NO.: NR-396-D-101-B DATE:
MAR 181998 DEVICE TYPE:
Thickness Gauge PROTOTYPE TESTING:
I2S did not supply prototype test results regarding mechanical operation (e.g., no specific data on retention of the source when the device is subjected to mechanical stimuli).
In lieu of such submission, I2S relied on the ANSI-N542 classification of the source and the past use of an almost identical device which they currently distribute in the U.S.
EXTERNAL RADIATION LEVELS:
The manufacturer reports that the dose rates for Model RSS-06 transmission gauge containing a 1.0 curie, Am-241 sealed source will not exceed the following:
Maximum Radiation Level Distance Shutter Open Shutter Closed (inches)
(cm)
(mem/hr)
(Sv/hr)
(mrem /hr)
(msv/hr) 1.97 5
1.2 12 0.85 8.5 11.81 30 0.3 3
0.02 0.2 39.37 100 0.03 0.3' O.006 0.06 The dose rates were taken with no material present in the measuring gap.
I2S indicates this represents the highest radiation levels of any of the possible configurations.
\\
i ii
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
PAGE 6 OF 8 NO.: NR-396-D-101-B DATE:
pgg ) g )ggg DEVICE TYPE:
Thickness Gauge OUALITY ASSURANCE AND CONTROL:
I2S maintains a quality assurance and control program which has been deemed acceptable for licensing purposes by NRC.
A copy of the program is on file with the NRC.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
- The device may be distributed to specific or general licensees of NRC or an Agreement State.
- Handling, storage, use, transfer, and disposal:
To be determined by the licensing authority or as required by 10 CFR 31.5, or Agreement State equivalent.
- The device shall be leak tested at intervals not to exceed 6 months using techniques capable of detecting 0.005 microcurie (185 Bq) of removable contamination.
- General licensees using the devices are authorized to perform certain maintenance on the device, such as changing the shutter indicator lights and removal and maintenance of the gauge receiver head.
- This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.
I j
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-396-D-101-B DATE:
PAGE 7 OF 8 DEVICE TYPE:
Thickness Gauge
. SAFETY ANALYSIS
SUMMARY
' Ias has submitted sufficient information to provide reasonable assurance that:
- The device can be safely-operated by persons not having training in radiological protection.
- Under ordinary conditions of handling, storage, and use of the device,cthe byproduct material contained in the device will'not be. released or-inadvertently removed from the source housing, and it is unlikely that any person will receive in any period of one year a dose in excess of 10 percent of'the limits specified in Section 20.1201(a),
~
- Under accident conditions associated with handling, storage, and use of the source housing, it is unlikely that any person would receive an external radiation dose or dose commitment in excess of the dose to the appropriate organ as specified in the following chart:
PART OF BODY DOSE Whole body; head and trunk; active blood-forming organs; gonads; or lens of eye 15 rem (0.15 SV):
-Hands and forearms; feet and ankles;. localized areas of skin averaged over areas no larger than 1 square. centimeter 200 rem '(2.0 Sv)
Other organs-50 rem (0,50 Sv)
/
s T '
REGISTRY OF RADIOACTIVE SEALED SOURCES ANb DEVICES
~
SAFETYcEVALUATION OF DEVICE
- (AMENDED,.IN ITS ENTIRETY)
PAGE 8 OF 8 EQa NR-396-D-101-B DATE:
g 3 g gggg DEVICE TYPE:
Thickness Gauge
' SAFETY ANALYSIS
SUMMARY
(Cont'd)-
Based on review of the Model RSS-06, and the information and test data cited below, we continue to conclude that the device is
. acceptable for licensing purposes.
'Furthermore, we continue to conclude that the device would be expected to maintain its containment integrity for normal conditions of use and accidental conditions which might occur during uses specified in this certificate.
REFERENCES:
The following supporting documents for the Model RSS-06 are hereby incorporated by reference and are made a part of this registry document.
- Integrated Industrial Systems' application dated October 7, 1993, and letters dated November 25, 1997, October 31, 1997, October 4, 1997, August 29, 1997, February 28, 1995, February 16, 1995, February 9, 1995, and October 3,
- 1994, with enclosures thereto.
' ISSUING AGENCY:
UlS. Nuclear Regulatory Commission Date:
I I 1999 Reviewer:
John W.
Lubinski 0 l9b3'
[
MW Date:
Concurrence-Steven L. Baggett 4
dm
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY) l NO.:. NR-396-D-101-B DATE:
MAR 181998 ATTACHMENT 1
... x..
LIGIITS p.
WARNING LABE1A -
,s 4
s
\\s
,/ \\
s s
haiIlli N,
u T'.
\\.
,._ _ ~ -,
- R ECEIVER ---- !ifp-g *l D
a.'.
f.l.l
!N R
{_ _
_.. ?
.._,_..O.
~ MEASURING CAP I, ]
[,
'i j bLd]-.
l l
5 4252 l
d-.
. ~. - _ - _
.G. _A U_G.. E
-- R ADMHON SOURCE L
l O
O I
C-
/c lU SHU1TER STOP j
p p
SEUTTER HOUSING r,-.'f::' s'@ ~
h INSIDE COVER
'f/
,jj /-
- f'B o
(SUB HOUSING) f f '.g
\\ (O) q.c4
.. :10 e
, ;[."
+v, Aff p:;~g
'. %::. :l~4 :
NC 1::
'/
s t~
o
'O sHuma /
TOP COVER (BOTTOM)
I
'^'
_as-e A-4' A+9 4_
4E-'
A'iW/Maar
'4Y *MW'
l l
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-396-D-101-B DATE:
M I8 ATTACHMENT 2 o
o REMOVAL OF THl$ LABEL is PROHIBITED!
g THIS L AdEL SHALL BE MAINTAINED Ob THE DEVICE IN LGGlBLE CONDITION The recept, possessipn, use and transfer of this device is subject to a general license or ttf6 equivalent, and the regulations of the U.S. NRC or a state wdh which the NRC has entered into an agreement for the exercise of regulatory autpority. Abandonment or disposal prohibited unless trans -
ferred to persons specifically licensed by U S. NRC or agreement state.
Operation is prohibited if there is indication of failure or damage to shield- ~
ing, source containment or onioff mechanism. Only persons specifically licensed by the U.S. NRC or agreement state may. install, dismaritle, relo-cate, repair or test this device. Device shall be tested for radioactive leak-age and proper fonctioning of on/off mechanism and indicatos at installa -
tion, at source replacement and thereafter at no longer than six (6) month intervals. Loss, theft or transfer of this device to another licensee and f ailure or qfamage to, shielding, source containment or on off mechanism must tae reported to U S.
NRC or agreement states.
u INTERGRATED lNDUSTRIAL MODEL:
SYSTEMS 475 MAIN ST SERIAL:
o YALESVILLE, CT l
A
,J.----
PAGE1 NRC FORM 567 U. S. NUCLEAR REOULATORY COMMISSION REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send the request AND a copy of all related letters /ww and draw 6ngs to: The Seeled Source Safety Section, ATTN: CNef, OWFN Ms.1 Stop 6 H3. Change the Ucense Tracidng System rnilestone to 19 and ass %n to reviewer code I-5.
NOTE: Retain a copy of tNs request with the applicebon and back9round files.$O lDk lO(LG lli IV DV D HQ R LFDCB TEEPHONE NUMBER DATE V TYPE OF ACTION REQUESTED (Check as appropriate) APPUCANTS NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET BENS) MAa Control NUMBER (S) DEVICE REVIEW N b" ~/Obb LETTER /APPUCADON DA UCENSE NUMBER (S) CUSTOM REVIEW } / U 1//-f e9/64k4.Zidctsbeu/ Sy3kmS,. DStr. //7S MbW SM<ef fplan/te, c r OWF-L FOR 5888 USE Ota.Y """""^'""" "*""""""?3s - o (o 97-FA DATE TO FEES I $ol9'l DATE ASSKMED f/1/& I Lol9Y DATE RECElvED / TYPE OF ACTIOl4 (Indiente the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM) J SOURCE (9C) DEVICE (9A) SOURCE (90) DEVICE (98) ]NEW ] NEW NEW N AMENDMENT y MENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Specoy) TOTAL NUMBER OF NOTES ~ REVIEW HOURS M NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY NEW REGISTRATION - ] MODUCT INACTE - NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY vwE OF FEE FEE CATEGORY ~ 9C U 9D MM @ 9A 98 AMOUNT RECENED CHE L ~ AS REQUIRED MATANN UPDATED ' h (() 6 3 (, '= iss.a _J MATSYS UPDATED gy wN oAn== AS REQUIRED -o., om om g 47 a a u 9 c n e 9 >y awaru ~~ NRC f ORM W (843) ggg