4 REGISTRY'OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
PAGE 1 OF 6 RQJ N7-522-D-882-8 DATE:
MAR 181998 DEVICE TYPE:
Source Housing MODEL:
SHRH-A Series MANUFACTURER / DISTRIBUTOR:
Ohmart Corporation 4241 Allendorf Drive
~
Cincinnati, OH 45209 SEALED SOURCE MODEL DESIGNATION:
Ohmart Models:
A-2100 A-2102
~
A-5771 A-5772 A-33131 Amersham Corporation Model: AMN.PE1 ISOTOPE:
MAXIMUM ACTIVITY:
Cesium-137 750 millicuries (A-2102 ira single point configuration) l 600 millicuries / foot (A-5771, A-2102 in multiple point configuration,* not to exceed 6 curies per source housing)
Cobalt-60 35 millicuries (A-2100, A-5772)
Californium-252 0.23 millicuries (A-33131)
Americium-241/ Beryllium 260 millicuries (AMN.PEl)
.s LEAK TEST FREOUENCY:
36 Months PRINCIPAL USE:
(D) Gamma Gauge CUSTOM DEVICE:
YES X
NO
')
- See Section.'* Limitations and/or'Other Considerations of Use" q
l 9804060053 900318 i
PDR RC i
SSD PDR l
.t 1evLrtsyvv 4 j
e y
~
h '
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF" DEVICE (AMENDED IN ITS_ ENTIRETY)
NO.: NR-522-D-882-B DATE:
PAGE 2 OF 6 pgg 7gg DEVICE TYPE:
Source Housing DESCRIPTION:
The Model SHRH-A Series source housings are basically similar in design, construction, and operation to the Ohmart Model SHRM source housing except that the shutter of the Model SHRH-A can-be locked in the closed position by a padlock through a stud on the shutter handle and a hinged stud bolted to the unit.
The source
. housings are 6.25 inches in diameter and are manufactured in
.various lengths.
The source housings may contain either point sources, Ohmart Models A-33131, A-2102, or A-2100 or Amersham Model AMN.PE1, or strip sources, Ohmart Models A-5771 or A-5772, depending on the overall length of the source housing and the purpose for which it is to be used.
In addition, source housings used by E.
I.
DuPont Company in Chattanooga, Tennessee, contain multiple A-2102 point sources.
The " active" length of sources will be shown in the model number of the source housing. Source housings containing a single. point source will have SHRH-A as the model number designation.
The source housing shutter is manually operated and the source housing may be used in special gauge configurations by mounting
)
-on the side of a vessel or pipe.
The source housing may be
_]
modified by additional external shielding.
DIAGRAM:
An engineering drawing of the source housing is shown in attachment 1.
(
LABELING:
The source housings'are labeled in accordance with Section 20.203, 10 CFR Part 20.
The labels contain the radiation symbol, isotope, activity, model number, serial number, name of the manufacturer, and the words " CAUTION-RADIOACTIVE MATERIAL".
i In addition, source housings intended for distribution to persons generally licensed will be labeled in accordance with 10 CFR Part 32.
' REGISTRY OF RADIOACTIVE SEALED; SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-522-D-882-B DATE:
PAGE 3 OF 6 MAR 181998 DEVICE TYPE:
Source Housing LABELING (cont'd):
The labels are made of stainless steel or-aluminum and are permanently attached by rivets or screws to the source housings.
EXTERNAL RADIATION LEVELS:
LThe Ohmart Corporation reports that the radiation levels around the-source housing will not exceed 5 mR/hr at 12 inches from the any accessible surface of the source housing.
CONDITIONS OF NORMAL USE:
The source-housings are intended for use in industrial and process control environments for measurement of density and/or level of materials.
All. persons are able to operate.the source housing under proper conditions with minimu'm radiation exposure.
PROTOTYPE TESTING:
The Model SHRH-A Series source housings have been in use since the early 1960's and there has been no reported incidents of failure related to radiological safety.
OUALITY ASSURANCE AND CONTROL:
The Ohmart Corporation maintains a quality assurance and control program.which has been deemed acceptable for licensing purposes by NRC.
A copy of the program is on file with the NRC.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
The source housings may be distributed to specific or
. general licensees of NRC or an Agreement State.
-The.Ohmart Corporation offers a full-range of service to its customers including: start-up supervision, radiation surveys, leak tests, leak test. kits, off/on operational check, and disaster assistance.
l
T s
' REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY, EVALUATION OF-DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-522-D-882-B-DATE:
PAGE 4 OF 6 g
DEVICE TYPE:
Source Housing LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (cont ' d) :
These source housings shall be leak tested at intervals not to exceed 36 months using techniques capable of detecting 0.005 microcurie of removable contamination.
This registration sheet and the information contained.within the references shall not be changed without the written consent of the NRC.
When distributed to general licensees, the source housings may be mounted by the user provided the shutter is locked in the "OFF" position and they follow the Ohmart Corporation's safety instructions.
When distributed to specific licensees, the source housings may be mounted by the user provided the shutter is locked in the "OFF" position, they follow the ohmart corporation's safety instructions, and they are licensed to mount the source housing.
Source housings intended for use under a general license shall be initially tested for external radiation levels, required labels, and leakage / contamination of radioactive material by persons specifically licensed by NRC or an Agreement State.
When additional external shielding is added to the source housing, the labeling described in this registration certificate must still be visible to the user of the source housing at all times.
Handling, storage, use, transfer and disposal: To be determined by the licensing authority.
6
-REVIEWER NOTE: The radiation levels for source housings distributed to general. licensees shall not exceed 5 mR/hr at 12" from any accessible surface of the application.
REVIEWER'S NOTE: The use of multiple point sources in place of' strip sources is authorized only for the' units located at the facilities of E..I. DuPont Company in Chattanooga, Tennessee.
Z
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO.: NR-522-D-882-B DATE:
PAGE 5 OF 6 g
g gggg
- DEVICE TYPE:
Source Housing SAFETY ANALYSIS
SUMMARY
Since the effective date of this document, the Model SHRH-A Series source housings are not current products manufactured by the Ohmart Corporation.
However, the source housings are handled in repairs, source replacements, and disposals.
The Ohmart Corporation has submitted sufficient information to provide reasonable assurance that:
The source housing can be safely operated by persons not having training in radiological protection.
Under ordinary conditions of handling, storage, and use of the source housing, the byproduct material contained in the source housing will not be released or inadvertently removed from the source housing, and it is unlikely that any person will receive in any period of one calendar quarter a dose in excess of 10 percent of the limits specified in the table in Section 20.101(a), 10 CFR 20.
Under accident conditions associated with handling, storage, and use of the source housing, it is unlikely that any person would receive an external radiation dose or dose commitment in excess of the dose to the appropriate organ as specified in the following chart:
PART OF BODY REM Whole. body; head and trunk; active blood-forming organs; i
gonads; or lens of eye 15 H
Hands and forearms; feet and ankles;-localized areas of skin averaged over areas no larger than 1 square centimeter 200 Other organs 50
- Based on our review of the information and test data contained in the references' cited below, and that'the source housings have
' been'in use since the early 1960's without any reported
)
I f
- 1'
REGISTRY.0F RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY)
NO : NR-522-D-882-B DATE:
PAGE 6-OF 6 WMR 181998 i
i DEVICE TYPE:
Source Housing' l
SAFETY ANALYSIS
SUMMARY
(cont'd):
i incidents, we continue to conclude that the Model SHRH-A Series source housings are acceptable for licensing purposes.
Furthermore, we :or tinue to conclude that these source housings would be expected to maintain their containment integrity for normal conditions of use and accidental conditions which might j
occur during uses specified in this certificate.
l
REFERENCES:
J The following supporting documents for the Model SHRH-A Series source housings are hereby incorporated by reference and are made a part of this registry document:
Ohmart Corporation's letters dated June 11, 1991, June 12, 1961, September 7 10, 1963, November' 15,~1963, July 9,
- 1975, December 1,'1986, and November 1, 1989, with enclosures thereto.
]
i Ohmart Corporation's letter dated February 27, 1998, with enclosures-thereto.
I ISSUING AGENCY; U.S. NUCLEAR REGULATORY COMMISSION DATE:
NIO REVIEWER:
~
fBh ?#.
ubinski 2
i
'DATE:
I CONCURRENCE'
- '\\
t
' St'sVen L. Bnggett 2
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (AMENDED IN ITS ENTIRETY) l NO.: NR-522-D-882-B DATE*
ATTACHMENT 1 g
1 Nh ab l
~
?.
l
~ ~
w i
h' d
!b
!c;
~
)
o o
U C "
g g
i s
l
\\,
+
e 4
e
)*
/,
8
,g g
6'
's,1, 's.
s s j
J./,.
s
~
/-
l l
g, e'
'\\
, \\,'.
.g
.'/.
l
.: '.c l
v 'X -
i l
l c
s 6
'344.L B&4&vdS.
./
4 e
I s, h l
b b
.*M, e
't i g,
0]
o i
I 8
,l
~
PAGE1 NRC FORM 567 U. S. NUCLEAR REGULATORY COMMISSION M
REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send tNs request AND a copy of all related letters /appimations and drawings to: The Seeled Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the Ucense Tracking System rnilestone to 19 and assign to reviewer code I-5.
NOTE: Retain a copy of tNs request with the appl 6 cat 6on and background flies.
7 REGION / LOCATION:
REQUESTER b /////h k/.,7MM N M lI R ll lli R IV RV R HQ LFDC3 TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate)
APPtCANrs NAME SOURCE REVIEW
[ AMENDMENT OF d#h M4y/Sd /
REGISTRATION SHEET NUMBER (S)
MAAL CONTROL NUMDER(S)
DEVICE REVIEW LETTER /APPUCATON DATE LCENSE NUMBER (S)
CUSTOM REVIEW
/X-52.2 f.PJ -/$
$/2 7 VS p gj
////-egg /g/: 2 /d O n e < /i M ^, 0 6 o d'?
FOR 8888 USE ONLY
"""""^""""
""~'" J Ta d w cs
" "'""""" q ///ef A 99-BS'
.A. A N.
.An ro Fen 33,r 3,,o,,,
3,,,,,
TYPE OF ACTION (Indicate the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPUCANT (CUSTOM)
SOURCE (90)
DEVICE (9A)
SOURCE (90)
DEVICE (98)
IMENDMENT NEW NEW NEW NEW
~
AMENDMENT AMENDMENT AMENDMENT g
NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED
) OTHER (Specify)
TOTAL NUMBER OF NOTES 7
REVIEW HOURS
- f 2
=' < ~
g
~~
p j
4/,
DEF EN LETTERS F EN CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -
_] PRODUCT INACTIVE-NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY ME OF FEE fed CATEGORY 9C U 90 19A U 9B A
AMOUNT RECEIVED 9
CHECK NUMBER MATANN UPDATED j(V,,
y AS REQUIRED
\\
@ '}
4 pp M"
_J gTSYS
== o' c"ec"
,,OU RED A _ ma r y g
-m eETU.~
COMMENTS
(
I NRC FORM 8e1 (5-o3) f N~*:
N
.