ML20217G669

From kanterella
Jump to navigation Jump to search
Summary of 970918 Meeting W/Util in Rockville,Md Re Status of Licensing Activities.Licensee Presented Overview of Structure & Usage of EOP & Planned Changes
ML20217G669
Person / Time
Site: Crystal River 
Issue date: 10/06/1997
From: Raghavan L
NRC (Affiliation Not Assigned)
To:
NRC (Affiliation Not Assigned)
References
NUDOCS 9710140127
Download: ML20217G669 (6)


Text

_ _ - - - - _ - _ _ - _

October 6,1997 s.

I LICENSEE:

Florida Power Corporation FACILITY:

Crystal River linit 3 (CR-3)

SUBJECT:

SUMMARY

OF MEETING ON SEPTEMBER 18, 1997 STATUS OF LICENSING ACTIVITIES On September 18, 1997, representatives of the Florida Power Corporation.

licensee for Crystal River Nuclear Plant. Unit 3. met with members of the staff at the U.S. Nuclear Regulatory Commission (NRC) Headquarters in Rockville. Maryland. is a list of attendees. is a copy of the agenda for the meetingc The licensee presented an overview of the structure and usage of its emergency operating procedures (EOP) and the planned changes to them.

The licensee presented the E0P steps for a scenario involving small break loss of coolant-accident (SBLOCA) coincident with loss of offsite power and a single failure of loss of B battery. This is one of-the three scenarios discussed in the licensee's proposed license amendment dated June 14. 1997 for mitigating SBLOCA events which is under staff review.

The discussions were working-level in nature and did not result in specific action items.

/S/

L. Raghavan. Project Manager Project Directorate 11-3 Division of Reactor Projects - 1/11 Office of Nutlear Reactor Regulation Docket No. 50 302.

Enclosures:

1.

Attendees List i

2.

Meeting Agenda 35

/

w I

cc w/ enclosures:

See next page

/

Document Name: G:\\ CRYSTAL \\970918. SUM Office PM:PDIl-3 LA:PDII-3 PD:PDil-3 Name LRaghavan W BClayton M FHebdon{-/

Date 10/L/97 10/ J /97 10/6 /97 Copy (fe'sYNo Yesd

'esplio) e

~ 0FFICIAL RECund Co n

ra o u s r a d,t,o f I.ll,I!,Il.li.l!I.ll II EU M C M S COPY

o

SUBJECT:

SUMMARY

OF MEETING ON SEPTEMBER 18, 1997 STATUS OF LICENSING ACTIVITIES 0.11tribution 1ARD COM'

)ocket

'le PUBLIC l

Crystal River Reading OGC ACRS L. Raghavan J. Johnson, Ril E Mai' S. Co' lins /F. Miraglia (SJC1.FJM)

R. Zimmernin (RPZ)

B. Boger (BAB2.RCN)

J. Zwolinski (JAZ)

K. Landis(KDL)

F, Hebdon B. Clayton J. Joudan, Ril T. Martin (e mail to SLM3)

M. Gameroni EDO

p1880s,q UNITED STATES g

y 4

g NUCLEAR REGULATORY COMMISSION e

WA8HINGTON. D.C. 20066 4 001 October 6, 1997 LICENSEE:

Florida Power Corporation FACILITY:

Crystal River Unit 3

SUBJECT:

SUMMARY

OF MEETING ON SEPTEMBER 18, 1997 STATUS OF LICENSING ACTIVITIES On September 18. 1997. representatives of the Florida Power Corporation.

licensee for Crystal River Nuclear Plant. Unit 3. met with members of the staff at the U.S. Nuclear Regulatory Commission (NRC) Headquarters in Rockville. Maryland. is a list of attendees. is a copy of the agenda for the meeting.

The licensee presented an overview of the structure and usa operating procedures (EOP) and the planned changes to-them.ge of its emergency The licensee presented the E0P steps for a scenario involving small break loss of-coolant-accident (SBLOCA) coincident with loss of offsite power and a single failure of loss of B battery.

This is one of the three scenarios discussed in the licensee's proposed license amendment dated June 14, 1997 for mitigating SDLOCA events which is under staff review.

The discussions were working level in nature and did not result in specific action items.

Af L. Raghavan. Project Manager Project Directorate 11 3 Division of Reactor Projects - I/11 Office of Nuclear Reactor Regulation Docket No. 50 302

Enclosures:

1.

Attendees List 2.

Meeting Agenda cc w/ enclosures:

See next page

o I

florida Power Corporation CRYSTAL RIVER UNIT NO. 3 GENERATING PLANT cc:

Mr. R. Alexander Clenn Mr. Robert E. Grazio, Director

~

Corporate Counsel Nuclear Regulatory Affairs (SA2A)

Florida Power Corporation Florida Power Corporation MAC-A5A Crystal River Energy Complex P.O. Box 14042 15760 W. Power Line Street St. Petersburg, Flerida 33733-4042 Crystal River, Florida 34428-6708 l

Mr. Charles Pardee, Director Senior Resident inspector Nuclear Plant Operations (NA20)

Crystal River Unit 3 Florida Power Corporation U.S. Nuclear Regulatory Commission Crystal River Energy Complex 6745 N. Tallahassee Road 15760 W. Power Line Street Crystal River, Florida 34428 Crystal River, Florida 34428-6708 Mr. James S. Baumstark Mr. Bruce J. Hickle, Director Director, Quality Programs (SA20) l Director, Restart (NA2C)

Florida Power Corporation Florida Power Corporation Crystal River Energy Complex Crystal River Energy Complex 15760 W. Power Line Street 15760 W. Power Line Street Crystal River, Florida 34428-6708 Crystal River, Florida 34428-6708 Regional Administrator, Region II Mr. Robert B. Borsum U.S. Nuclear Regulatory Commission B&W Nuclear Technologies 61 Forsyth Street, SW., Suite 23T85 1700 Rockville Pike, Suite 525 Atlanta, GA 30303-3415 Rockville, Maryland 20852 Mr. John P. Cowan Mr. Bill Passetti Vice President - Nuclear Production Office of Radiation Control (NA2E)

De)artment of Health and Florida Power Corporation lehabilitative Services Crystal River Energy Complex 1317 Winewood Blvd.

15760 W. Power Line Street Tallahassee, Florida 32399-0700 Crystal River, Florida 34428-6708 Attorney General Mr. Roy A. Anderson Department of Legal Affairs Senior Vice President The Capitol Nuclear Operations Tallahassee, Florida 32304 Florida Power Corporation ATTN: Manager, Nuclear Licensing Mr. Joe Myers, Director Crystal River Energy Complex (SA2A)

Division of Emergency Preparedness 15760 W. Power Line Street Department of Community Affairs Crystal River, Florida 34428-6708 2740 Centerview Drive Tallahassee, Florida 32399-2100 Mr. Kerry Landis U.S. Nuclear Regulatory Commission Chairman 61 Forsyth Street, SW., Suite 23T85 Board of County Commissioners Atlanta, GA 30303-3415 Citrus County 110 North Apopka Avenue Iverness, Florida 34450-4245

I CRYSTAL RIVER 3 MEETING SEPTEMBER 18. 1997 1

MfLS Oraanization L. Raghavan NRC NRR Fred Hebdon NRC NRR Walt Rogers NRC Ril D. Kunsemiller Florida Power Corp.

J. Bongarra NRC NRR Bill LeFave NRC NRR Jrank Orr NRC-NRR Scott Flanders NRC NRR Gary Becker Florida Power Corp.

Rolf Widell Florida Power Corp.

Paul Fleming Florida Power Corp.

Tim Catchpole Florida Power Corp.

Tom Harrison McGraw Hill Nucleonics

)

i i

AGENDA FOR RAI MEETING REGARDING SBLOCA EOP'S 9/18/97

. Introductions - Kunsemiller

. Overview of EOP Structure and Usage - Becker

. Outline Scenario of LOBB - Fleming

. Step through EOPs - Becker

. Responses to RAI-Catchpole

. Schedules - Widell

. Discussions -M1