Amends 209 & 191 to Licenses DPR-70 & DPR-75,respectively, Revise Emergency Core Cooling System Surveillance Test Acceptance Criteria in TSs 3/4.6.2 for Containment Spray Pumps
ML20217F393
Person / Time
Site: Salem  
Issue date: 03/24/1998
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Public Service Electric & Gas Co, Philadelphia Electric Co, Delmarva Power & Light Co, Atlantic City Electric Co
Shared Package
ML20217F398 List:
References
DPR-70-A-209, DPR-75-A-191 NUDOCS 9803310398
Download: ML20217F393 (8)


Text

p f%

\\

UNITED STATES p

NUCLEAR REGULATORY COMMISSION

~g WASHINGTON, D.C. 3e086 0001

~

o, PUBLIC 8ERVICE ELECTRIC & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY FI FCTRIC COMPANY DOCKET NCL50-272 SALEM NUCLEAR GENERATING STATION. UNIT NO.1 AMENDMENT TO FACILITY OPERATING LICENSE

' Amendment No.209 License No. DPR-70 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric & Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated November 4, igg 7, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR ChapterI; D.

The issuance of this amendment will not be inimical to the common d6fense and security or to the health and safety of the public; and l

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Speedications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-70 is hereby amended to read as follows:

9803310398 900324 PDR ADOCK 05000272 P

PDR

r 2

(2)' Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendices A and B, as revised through Amendment No.209, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specliications.

3. This license amendment is effective as of its date of issuance to be implemented within -

60 days.

FOR THE NUCLEAR REGULATORY COMMISSION e

J n F. Stolz, Director Joct Directorate 1-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance: March 24, 1998 i

i 1

)

4 ATTACHMENT TO LICENSE AMENDMENT NO. 209 FACILITY OPERATING LICENSE NO. DPR-70 DOCKET NO. 50-272 Revise Appendix A as follows:

Remove Pages insert Pages W4 &9 W4 &9

)

i

)

i

\\

t CONTAINMENT SYSTEMS 3/4.6.2 DEPRESSURIZATION AND COOLING SYSTEMS CONTAINMENT SPRAY SYSTEM

LIMITING CONDITION FOR OPERATION 3.6.2.1 Two independent containment spray systems shall be OPERABLE with each

' spray system capable of taking suction from the RWST and' transferring suction to the RHR pump discharge.

APPLICABILITY:

MODES 1, 2, 3 and 4.

ACTION:

With one containment spray system inoperable, restore the inoperable spray system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the inoperable spray system to OPERABLE status within the next 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.2.1,Each containment spray system shall be demonstrated OPERABLE:

a.

At least once per 31 days by verifying that each valve (manual, power operated or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

b.

By verifying, that on recirculation flow, each pump develops a differential pressure of greater than or equal to 204 psid when tested pursuant to' Specification 4.0.5.

c.

At least once per 18 months during shutdown, by:

l 1.

Verifying that each automatic valve in the flow path actuates to its correct position on a Containment High-High pressure test signal.

2.

Verifying that each spray pump starts automatically on a Containment High-High pressure test signal.

d.

At least once per 10 years by:

l 1.

Performing an air or smoke flow test through each spray header and verifying each spray nozzle is unobstructed.

SALEN - UNIT 1 3/4 6 --Amendment No, 763, 209 E

a_.

aroq p*

t UNITED STATES 3

)

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 30se64001 PUBLIC SERVICE FI FCTRIC & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-311 SALEM NUCLEAR GENERATING STATION. UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.191 License No. DPR-75 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric & Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated November 4,1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I; j

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authortzed by this amendment can i

be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compilance with the Commission's regulations set forth in j

10 CFR ChapterI;

]

D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating.

License No. DPR-75 is hereby amended to read as follows:

t(

2-(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendices A and B, as revised through Amendment No.191, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3. This license amendment is effective as of its date of issuance to be implemented within 60 days.

FOR THE NUCLEAR REGUI.ATORY COMMISSION s

h i F. Stolz, Director P oct Directorate 12 vision of Reactor Projects - t/ll Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: March 24, 1998 4

i

ATTACHMENT TO LICENSE AMENDMENT NO191 FACILITY OPERATING LICENSE NO. DPR-75 DOCKET NO. 50-311 Revise Appendix A as follows:

Remove Pages insert Pages 3/4 6-10 3/4 6-10 a

h

.i'*

3/4.6.2 DEPRESSURIZATION AND COOLING SYSTEMS

' CONTAINMENT SPRAY SYSTEM LIMITING CONDITION FOR OPERATION 3.6.2.1 Two independent containment spray systems shall be OPERABLE with each

spray system capable of taking suction from the RWST and transferring suction

-to the RHR pump discharge.

. APPLICABILITY: MODES 1, 2, 3 and 4.

~ ACTION:

With one containment spray system inoperable, restore the inoperable spray system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; restore the inoperable spray system to. OPERABLE status within the next 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.2.1 Each containment spray system shall be demonstrated OPERABLE:

a.

At least once per 31 days by verifying that each valve (manual, power-operated or automatic) in the flow path that is not locked, sealed, or otherwise secured in position, is in its correct position.

b.

By verifying, that on recirculation flow, each pump develops a differential pressure of greater than or equal to 204 psid when l

tested pursuant to Specification 4.0.5.

c.

At least once per 18 months during shutdown, by:

1.

Verifying that each automatic valve in the flow path actuates to its correct position on a Containment High-High pressure test signal.

2.

Verifying each spray pump starts automatically on a l

Containment High-High pressure test signal.

d.

At least once per 10 years by:

1.

Performing an air or smoke flow test through each spray header and verifying each spray nozzle is unobstructed.

(

l L

i SALEN - UNIT-2 3/4 6-10:

Amendment No.7((,191

,