October 2, 1997 Mr. Douglis R. Gipson Ssnior Vice Prrsidant Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, MI 48166
SUBJECT:
FERMI 2 - RELIEF REQUEST (RR-A15) FOR SYSTEM LEAKAGE TEST REQUIRED BY AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
{
SECTION XI(TAC NO. M99500)
L m
Dear Mr. Gipson:
By letter dated September 9,1997, as supplemented by a letter dated September 16,1997, the Detroit Edison Company (DECO or the licensee) requested relief from certain inservice inspection requirements of the ASME Boiler and Pressure Vessel Code (code),Section XI for the Fermi 2 pirnt. The licensee requested relief from performing a syttem leakage test at L
the nominal reactor coolant system pressure due to adverse plant conditions.
The staff has reviewed the request for relief from these Section XI requirements and has determined, pursuant to 10 CFR 50.5Sa(a)(3)(ii), that imposing the requirements at issue would result in hardship without a compensating ir: crease in the level of quality anJ safety at Fermi 2. Therefore, the staff finds your reauest for relief to be acceptable. A copy of the staff's safety evaluation is enclosed.
E Sincerely, ORIGINAL SIGNED BY Kevin A. Connaughton for r
John H. Hannon, Project Director Project Directorate 111-1 Division of Reactor Projects - Ill/IV l
Office of Nuclear Reactor Regulation Docket No. 50-341
Enclosure:
Safety Evaluation cc w/ encl: See n6 t page M[f)[
DISTRIBUTION:
- Docket File PUBLIC PD# 3-1 Reading E. Adensam (EGA1)
SEDB (TLH3)
OGC G. Hill (2)
ACRS G. Tracy PPatnaik M. Jordan, Rlli DOCUMENT NAME: G:\\WPDOCS\\ FERMI \\FE99500.RLF
- SEE PREVIOUS CONCURRENCE To receive a copy of thle document, Indicate in the box: "C" = Copy weout attachment / enclosure "E" = Copy we attachment / enclosure "N" a No cog'y OFFICE PM:PD31 E
LA:PD31 E
C:ECGB*
OGC*
D:PD31 ja g
g NAME AKuglerdb Ofit-CJamerson 6/
GBagchi RBachmann JHann@%{,4
DATE 10/2 /97
\\
10/2 /97
/j 09/22/97 09/26/97 10/-497 OFFIOfAL F ECORD COPY 9710070294 971002
{ { {.]
}
DR ADOCK 0500 1
Mr. Douglas R. Gipson Fermi 2 Detroit Edison Company cc:
1 John Flynn, Esquire Senior Attomey l
Detroit Edison Company 1
2000 Second Avenue Detroit, Michigan 48226 Drinking Water and Radiological Protection Division Michigan Department of Environmental Quality -
3423 N. Martin Luther King Jr Blvd P. O. Box 30630 CPH Mailroom Lansing, Michigan 48909-8130 U.S. Nuclear Regulatory Commission Resident inspector's Office 6450 W. Dixie Highway Newport, Michigan 48166 Monroe County Emergency Management Division 963 South Raisinville Monroe, Michigan 48161 Regional Administrator, Region ill U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Norman K. Peterson Director, Nuclear Licensing Detroit Edison Company Fenni 2 - 280 TAC 6400 North Dixie Highway Newport, Michigan 48166 August 1997
_. _..