Amend 89 to License NPF-58,revising Existing Exception to LCO 3.0.4 as It Applies to LCO 3.6.1.9 for MSIV LCS by Making Exception Permanent
ML20217E198
Person / Time
Site: Perry 
(NPF-58-A-089, NPF-58-A-89)
Issue date: 09/24/1997
From: Hopkins J
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20217E202 List:
References
NUDOCS 9710060381
Download: ML20217E198 (4)


Text

- _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _

, pa ang y*

t UNITED STATES g

]

NUCLEAR RE2ULATCRY CSMMISSIZN WASHINGTON, D.C. someHoot

.....f a

THE CLEVELAND ELECTRIC ILLUMINATING COMPANY. ET AL.

DOCKET NO. 50-440 PERRY NUCLEAR POWER PLANT. UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 89 License No. NPF-58 1.

The U.S. Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by The Cleveland Electric Illuminating Company. Centerior Service Company Duquesne Light Company, Ohio Edison Company. OES Nuclear. Inc., Pennsylvania Power Company, and Toledo Edison Company (the licensees) dated May 2.1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter 1:

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission:

C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations:

D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public: and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-58 is hereby amended to read as follows:

ilA 2888A 8?888h o P

PDR

^

(2) Technical-Soecifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B. as revised through Amendment.No. 89, are hereby incorporated into this-license.

The Cleveland Electric Illuminating Company shall operate the facility in accordance with the-Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance and shall be implemented not later than 90 days after issuance.

FOR THE NUCLEAR REGULATORY COMMISSION i.

Jon B. Hopkins. Sen r Project' Manager Project Directorate III-3 Division of Reactor Projects III/IV

- Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: september 24, 1997 i

4 4Q.**:

  • vp-s.w 1-

%<+JP-g+y,,,g-,q q,g 9m..

.m,

_m

_y,

ATTACHMENT-TO LICENSE AMENDMENT NO. 89 FACILITY OPERATING LICLNSE-NO. NPF-58 00CKET'NO. 50-440 Replace the following page of the Appendix "A". Technical Specifications with

.the attached page. The revised page is identified by Amendment-number and contains vertical lines indicating the area of change.

Remove Insert 3.6 3,6-27

_-_----------..-a-

MSIV LCS 3.6.1.9.

3.6 CONTAINMENT SYSTEMS 3.6.1.9 Main _ Steam Isolation Valve (MSIV) Leakage Control System (LCS)

LC0 3.6.1.9 Two MSIV LCS subsystems shall be OPERABLE.

j APPLICABILITY:

MODES 1. 2. and 3.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

One MSIV LCS subsystem A.1


NOTE--------

inoperable.

LCO 3.0.4 is not ap>11 cable for the inaoard MSIV LCS subsystem.

Restore MSIV LCS 30 days subsystem to OPERABLE status.

B.

Two MSIV LCS B.1 Restore one MSIV LCS 7 days

-subsystems inoperable, subsystem to OPERABLE status.

C.

Required Action and C.1 Be in MODE 3.-

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time not met.

AND C.2 Be in MODE 4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> PERRY - UNIT 1 3.6-27 Amendment No. e,M,89

- - - _ -. -..