O O^9r412o.'998

+

l LICENSEE:

Tennessee Valley Authority FACILITY:

Browns Ferry, Unita 1,2 and 3 f

i

SUBJECT:

SUMMARY

OF MEETING WITH TENNESSEE VALLEY AUTHORITY ON CONVERSION TO IMPROVED TECHNICAL SPECIFICATIONS - MEETING OF APRIL 14,1998 (TAC NOS. M96431, M96432 AND M96433)

On April 14,1998, the U.S. Nuclear Regulatory Commission staff, L. Raghavan and Carl Schulten, met with representatives of the Tennessee Valley Authority (TVA), Bert Morris, l

Doug Dyar and Dave Burrell, the licensee for Browns Ferry Nuclear Plant, Units 1,2 and 3.

The discussions were technical and working level in nature relating to the licensee's l

j amendment request for conversion of custom technical specifications (TS) to the improved l

standard TS. Specifically, the discussions focused on TS Section 3.3. The meeting did not l

result in any regulatory action.

l l

/s/

l L. Raghavan, Senior Project Manager l

Project Directorate 11-3 Division of Reactor Projects - 1/il Office of Nuclear Reactor Regulation Docket Nos. 50-259 50-260 50-296 cc: See next page DISTRIBUTION E-Mail Docket File SCollins/FMiraglia TMartin (SLM3)

CSchulten PUBLIC BBoger MTschiltz (MDT)

AChu BFN r/f JZwolinski LPlisco, Ril TLe OGC FHebdon JLuehman BTjader ACRS BClayton MWeston LRaghavan To receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy 0FFICE PM:PDil-3 lE LA:PDII-3

,l E D:PDII-3 l

l l

NAME LRaghavan:cw IL BClayton #AA./

FHebdon (J.6 M i

DATE 04/2p/98 04/ M /98 04/2498 Official Record Copy DOCUMENT NAME: G:\\BFNt980414. SUM

\\i ()

I e 0\\

5)5

47 hhh ffh 900424 336 900420 g

PDR ADOCK 05000259 P

PDR J

r pn ctruq

[

l 0

1 UNITED STATES l

j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666-0001 o

% * * * * *,o April 20, 1998 LICENSEE:

Tennessee Valley Authority FACILITY:

Browns Ferry, Units 1,2 and 3 l-

SUBJECT:

SUMMARY

OF MEETING WITH TENNESSEE VALLEY AUTHORITY ON CONVERSION TO IMPROVED TECHNICAL SPECIFICATIONS - MEETING OF APRIL 14,1998 (TAC NOS. M96431, M95432 AND M96433) l l

On April 14,1998, the U.S. Nuclear Regulatory Commission staff, L. Raghavan and Carl Schulten, met with representatives of the Tennessee Valley Authority (TVA), Bert Morris, Doug Dyar and Dave Burrell, the licensee for Browns Ferry Nuclear Plant, Units 1,2 and 3.

The discussions were technical and working level in nature relating to the licensee's j

amendment request for conversion of custom technical specifications (TS) to the improved L

standard TS. Specifically, the discussions focused on TS Section 3.3. The meeting did not j

result in any regulatory action.

j L. Raghavan, Senior Project Manager Project Directorate 11-3 Division of Reactor Projects -1/11

)

Office of Nuclear Reactor Regulation Docket Nos. 50-259 50-260 50-296 i

3 cc: See next page 1

r

0 L-Mr. O. J. Zeringue BROWNS FERRY NUCLEAR PLANT Tennessee Valley Authority cc:

Mr. J. A. Scalice, Senior Vice President Mr. Mark J. Burzynski, Managar i

Nuclear Operations Nuclear Licensing Tennessee Valley Authority Tennessee Valley Authority 6A Lookout Place 4J Blue Ridge 1101 Market Street 1101 Market Street Chattanooga, TN 37402-2801 Chattanooga, TN 37402-2801 Mr. Jack A. Bailey, Vice President Mr. Timothy E. Abney, Manager Engineering & Technical Services Licensing and Industry Affairs Tennessee Valley Authority Browns Feny Nuclear Plant 6A Lookout Place Tennessee Valley Authority 1101 f larket Street P.O. Box 2000 Chattanooga, TN 37402-2801 Decatur, AL 37402-2801 Mr. C. M. Crane, Site Vice President Regional Administrator, Region ll Browns Feny Nuclear Plant U.S. Nuclear Regulatory Commission i

Tennessee Valley Authority 61 Forsyth Street, SW., Suite 23T85 P.O. Box 2000 Atlanta, GA 30303-3415 Decatur, AL 35609 Mr. Leonard D. Wert General Counsel Senior Resident inspector Tennessee Valley Authority U.S. Nuclear Regulatory Commission ET 10H Browns Ferry Nuclear Plant 400 West Summit Hill Drive 10833 Shaw Road Knoxville, TN 37902 Athens, AL 35611 Mr. Raul R. Baron, General Manager State Health Officer Nuclear Assurance Alabama Dept. of Public Health Tennessee Valley Authority 434 Monroe Street I

4J Blue Ridge Montgomery, AL 35130-1701 1101 Market Street Chattanooga, TN 37402-2801 Chairman Limestone County Commission Mr. Karl W. Singer, Plant Manager 310 West Washington Street Browns Ferry Nuclear Plant Athens, AL 35611 Tennessee Valley Authority P.O. Box 2000 Decatur, AL 35609 l