O(p a l 99-f
~
a
- via A M',
TRANSNUCLEAR, INC.
Mrs. Gloria Bennington June 18,1999 0-)0 0j{
Division of Safeguards and Transponation U.S. Nuclear Regulatory Commission T
c Washington,DC 20555 Transnuclear reference: TNY 99062-6)
Advance notification for an unport snipment of nuclear material from countries that are not party to the Convention on the Physical Protection of Nuclear Material.
Dear Mrs. Bennington:
This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an impon shipment oflow strategic significance material from Countries that are not party to the Convention on the Physical Protection ofNuclear Material.
Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:
73.74(a)(3)(i) Data:
Imponer ofRecord Receiving Facility COGEMA, Inc.
Westinghouse Nuclear Fuels Division 7401 Wisconsin Avenue 5801 BluffRoad Bethesda,MD 20814 Columbia,SC 29209 301/986-8585 803/776-2610 Shipping Facility Carders Eurodif, Pierrelatte Atlantic Centainer Lines Usine du Triocastin BP 175 50 Cragwood Road 26702 Pierrelatte, France So.Plainfield,NJ 07080 33 7550 4000 908/668-5556 Transport Coordinator AND Transnuclear, Inc.
Advanced Distribution Systems Four Skyhe Drive 2329 So. Hayden Road Hawthome,NY 10532 Spokane,WA 99224 914/347-2345 1-800/756-0223 j
FOUR SKYLINE DRIVE, HAWTHORNE, NEW YORK 10532 po m oo.
,,m o. _,aa.
4 m e. m.
9910120083 990701 PDR ADOCK 07001426
- DN! *B0313ONSNOM1 OE:TT 666T-Ot-Nnt w *u o uu m uv w
11 i
M i-/
G.Bennington, USNRC TNY 99062-6 Page 2 of 2 June 18,1999 73.74(a)(3)(ii) Data Physicaldescriptionofshipment:
3 model 30B cylinders inside overpacks containing: RQ, URANIUM HEXAFLUORIDE, FISSILE (containing more than 1% U235),7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight: 6264 kg. Approximate U weight: 4235 kg enriched to less.
Than 5%. Approximate weight U235: 187 kg 73.74(a)(3)(iii)(iv)(v) Data:
MODE ORIGIN (0), TRANSFER (T),
ROUTE DATEfrIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&
(A) & DEPARTURE (D) AT DESTINATION (D) POINTS EACH POINT Rail Pierrelatte, FRANCE Standard rail (D)
July 9,1999 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Antwerp, BELGIUM (A)
July 13,1999 Ocean standard ocean 0800 -2359 hours M. comp.aion (D)
July 14,1999 Liverpool, ENGLAND (A/D) July 17,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) July 25,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth,NJ (A/D) July 27,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Baltimore,MD (A/D) July 29,1999 0800 -2359 hours Portsmouth,VA Standard Truck (D)
August 3,1999 0800 -2359 hours Arrival at the receiving facility is estimated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> on
' August 4,1999, this shipment will meet the levels of physical protection specified in Appendix E (Annex I).
l Yours truly, Tran uclear,Inc.
Mathew George Traffic Coordinator 0040 *d OLTS 4tE Pt6
'3NI '803~OnNSNO81 OE:tT 666T-8t-Nnt