Submits Revised Advance Notification for Import Shipment of Nuclear Matl from Countries Not Party to Convention on Physical Protection of Nuclear Matl Consisting of 3 Model 30B Cylinders Inside Overpacks
ML20217A767
Person / Time
Site: 07001426
Issue date: 07/01/1999
From: George M
TRANSNUCLEAR, INC.
To: Bennington G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20217A771 List:
References
TNY-99062-6, NUDOCS 9910120080
Download: ML20217A767 (2)


Text

06a /9 -/p g u.

q *

&I

'I' h1.

TRANSNUCLEAR, INC.

j Mrs. Gloria Bennington July 1,1999

( Q hlQh Division of Safeguards and Transportation U.S. Nuclear Regulatory Commission

)

Washington,DC 20555 Q g y l S$_

]

CRe:

Transnuclear reference: TNY 99062-6 Advance notification for an import shipment ofnuclear material from countries that are not party to the Convention on the Physical Protection ofNuclear Material.

Dear Mrs. Bennington:

l This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment oflow strategic significance material from Countries that are not party to the Convention on the Physical Protection ofNuclear Material.

Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:

73.74(a)(3)(i) Data:

Importer of Record Receiving Facility 1

COGEMA,Inc.

Westinghouse Nuclear Fuels Division 7401 Wisconsin Avenue 5801 BluffRoad i

l Bethesda,MD 20814 Columbia, SC 29209 301/986-8585 803/776 2610 Shipping Facility Carriers I

Eurodif, Pierrelatte Atlantic Container Lines Usine du Triocastin BP 175 50 Cragwood Road 26702 Pierrelatte, France So.Plainfield,NJ 07080 i

33 7550 4000 908/668-5556 i

Transport Coordinator AND Transnuclear, Inc.

Advanced Distribution Systems Four Skyline Drive 2329 So. Hayden Road Hawthome,NY 10532 Spokane,WA 99224 I

Ii 914/347-2345 1-800/756-0223 fj'.N FOUR SKYLINE DRIVE, HAWTHORNE, NEW YORK 10532 Phone: 914 347 2345

  • Fax: 914 347 2346 9910120000 990701 PDR ADOCK 07001426 C

PDR

m

  • n*c6 m oi o(,;t/99_f 4

T./uc>

cv G. Bennington,USNRC -

TNY 99062-6 Page 2 of 2 July 1,1999 73.74(aX3Xii) Data

' Physical description ofshipment:

3 model 30B cylinders inside overpacks containingi RQ, URANIUM HEXAFLUORIDE,

. FISSILE (containing more than 1% U235),7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight: 6264 kg. Approximate U weight: 4235 kg enriched to less.

Than 5%. Approximate weight U235: 187 kg 73.74(a)(3)(iii)(iv)(v) Data:

MODE-ORIGIN (0), TRANSFER (T),

ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&

(A) & DEPARTURE (D) AT DESTINATION (D) POINTS EACH POINT Rail Pierrelatte, FRANCE Standard rail (D)

July 16,1999 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Antwerp, BEL IUM (A)

July 20,1999 Ocean standard ocean 0800 -2359 hours M.c ervsa. e (D)

July 21,1999 Liverpool, ENGLAND (A/D) July 24,1999 0800 -2359 hours Halifax, CANADA (A/D) August 1,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth,NJ (A/D) August 3,1999 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Baltimore, MD (A/D) August 5,1999 0800 -2359 hours Portsmouth, VA Standard Tmck (D)

August 6,1999 0800 -2359 hours

- Arrival at the receiving facility is estimated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> on

~ August 11,1999, this shipment will meet the levels ofphysical protection specified in

. AppendixE(AnnexI).