ML20217A039

From kanterella
Jump to navigation Jump to search
Commission Voting Record on SECY-97-273 Re Staff requirements,SECY-96-221, Improving NRC Control Over & Licensee Accountability For,Generally & Specifically Licensed Devices
ML20217A039
Person / Time
Issue date: 04/13/1998
From: Vietticook A
NRC OFFICE OF THE SECRETARY (SECY)
To:
Shared Package
ML20217A044 List:
References
REF-10CFR9.7 SECY-96-221-C, SECY-97-273-C, NUDOCS 9804220138
Download: ML20217A039 (2)


Text

,

)

RY CO@lthf0f(EASED TO THE PDR 4,

NUCLEAR REG LAT 20555-0001 AEL WASHINGTON, D.C.

%, * * * * *,o April 13,1998 N

W date initidis I

'A'ci,fd"'

COMMISSION VOTING RMCDMO* * * * * * * * * * * * * *

  • l DECISION ITEM:

SECY-97-273 a

TITLE:

STAFF REQUIREMENTS -- SECY-96-221 -

"lMPROVING NRC'S CONTROL OVER, AND LICENSEES' ACCOUNTABILITY FOR, GENERALLY AND SPECIFICALLY LICENSED l

DEVICES" I

The Commission (with Commissioners Dicus, Diaz, and McGaffigan. agreeing) disapproved the subject paper as recorded in the Staff Requirements Memorandum l

(SRM) of April 13,1998. Chairman Jackson approved the paper, but also agreed with the other Commissioners that the proposed approach by the staff did not go far enough l

In meeting the recommendations in the Working Group study.

l This Record contains a summary of voting on this matter together with the individual i

vote sheets, views and comments of the Commissioners, and the SRM of April 13, l

1998.

i kmL

/\\&

Annette L. Vietti-Cook Acting Secretary of the Commission Attachments:

1. Voting Summary
2. Commissioner Vote Sheets
3. Final SRM l

cc:

Chairman Jackson Commissioner Dicus Commissioner Diaz i

j Commissioner McGaffigan CO i

OGC

{

EDO PDR DCS

../;t.

L*

l l

98o4220138 980413 l

PDR COMMS NRCC t

CORRESPONDENCE PDR C Uf-ti '>

(

i li-1 l

VOTING

SUMMARY

- SECY-97-273 RECORDED VOTES l

NOT APRVD DISAPRVD ABSTAIN PARTICIP COMMENTS DATE CHRM. JACKSON X

X 3/5/98 COMR. DICUS X

X 2/5/98 COMR. DIAZ X

X 2/18/98 l

COMR. McGAFFIGAN X

X 3/17/98 i

COMMENT RESOLUTION l

Chairman Jackson approved the paper but believed that the staff proposal did not adequately meet the recommendations in the Working Group study. Commissioners l

Dicus, Diaz, and McGaffigan disapproved the paper primarily for that same reason.

Chairman Jackson and Commissioner McGaffigan noted that because of significant l

changes since the 1991 proposed rule was issued for comment, the rule should be l

republished for comment before going to the final rule stage. Commissioner McGaffigan suggested that drafting a new proposed rule may be less resource intensive. Cornmissioners Dicus and Diaz would have preferred to finalize the rule directly. Additional comments were provided on the need to update the Enforcement l

Policy, the follow up procedures with licensees, coordinaticn with other Federal and l

State agencies, resource estimates and the need to reprogem resources, dealing with I

orphan sources, and vendor requirements. Subsequently, the comments of the Commission were incorporated it, the guidance to staff as ref'ected in the SRM issued on April 13,1998.

l I

,