ML20216B776

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-440/98-06 on 980128-0310.No Violations Noted.Advises That Failure of Operators to Promptly Identify Inoperable Containment Isolation Valve on 980308,reinforced Concern W/Frequency & Quality of Control Panel Walkdowns
ML20216B776
Person / Time
Site: Perry 
Issue date: 04/01/1998
From: Grant G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Myers L
CENTERIOR ENERGY
Shared Package
ML20216B784 List:
References
50-440-98-06, 50-440-98-6, NUDOCS 9804140106
Download: ML20216B776 (2)


See also: IR 05000440/1998006

Text

r-

-

Pub /d /FD/

,.

.

April 1, 1998

Mr. Lew W. Myers -

Vice President - Nuclear

L-

Centerior Service Company-

P. O. Box 97, A200

i.

'

!-

~ Peny, OH 44081

SUBJECT:

NRC INSPECTION REPORT NO. 50-440/98006(DRP)

Dear Mr. Myers:

On March 10,1998, the NRC completed a routine safety inspection at your Perry Nuclear Power -

Plant. The enclosed report presents the results of that inspection.

During this six-week inspection period, your conduct of activities was characterized by continued -

conservative operation of the plant. However, the failure of operators to promptly identify an

' inoperable containment isolation valve on March 8,1998, reinforced our previously expressed

concem with the frequency and quality of control panel walkdowns.' Additionally, several .

. examples of scaffolding storage, and installation problems are discussed in this report.

-

No violations of NRC requirements were identified during the course of this inspection.

l

,

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and its

p

enclosure will be placed in the NRC Public Document Room.

Sincerely,

/s/ Marc L. Dapas for

Geoffrey E. Grant, Director

Division of Reactor Projects

Docket No.:~ 50-440

License No.: NPF-58

Enclosure:

Inspection Report -

'

,

l

No. 50-440/98006(DRP)

See Attached Distribution

j

DOCUMENT NAME: G:\\PERR\\PER98006.DRP

To receive e copy of this doeurnent, indicate in the box "C" = Copy without attachment / enclosure "E" a Copy with attachment / enclosure "N" = No copy

OFFICE

Rlli

l6 Rlll

6/ Rlli

l

Rlli

l

NAME

TKozak:nh@

GGrantM[or

DATE

04/f l98

04///98

04/ /98

04/ /98

~

OFFICIAL RECORD COPY

9804140kO6

401

?

PDR

ADOCK 05000440

ff

G

PDR

l

,

,

l

.

(

L. Myers

-2-

,

l

cc w/encli

H. L. Hegrat, Manager

Regulatory Affairs

T. S. Rausch, Director, Quality

l

and Personnel Development

l

R. W. Schrauder, Director

i~

Nuclear Engineering Department

W. R. Kanda, General Manager.

Nuclear Power Plant Department

)

N. L Bonner, Director, Nudear

Maintenance Department

l

H. W. Bergendahl, Director

!

Nuclear Services Department

Ohio State Umison Officer

Robert E. Owen, Ohic

Department of Health

C. A. Glazer, State of Ohio

Public Utilities Commission

l

Distribution:

Docket File w/enci

DRP w/ encl

PUBLIC IE-01 w/enci

Rlli PRR w/enci

l

Project Manager, NRR w/ encl

IEO w/enci (E-mail)

A. B. Beach w/ encl

Rill Enf. Coordinator w/enci

Deputy RA w/enci

DRS (2) w/enci

TSS w/enci

DOCDESK (E-mail)

SRI Perry w/enci

GREENS

l

!

!

!-

i.

'

.

.

.

. . .

.

. . .

.

. _ .